LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

Similar documents
Emergency lighting units EM powerled

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LED Driver Linear / area fixed output

LED Driver Compact dimming

Emergency lighting units EM powerled

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

LED control gear Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

LED Driver Compact dimming

LED Driver Compact dimming

LED Driver Linear / area dimming

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LED Driver Constant voltage

LED Driver Compact dimming

LED Driver Compact dimming

DALI TOUCHPANEL BASIC TW. Operating and control unit

OPTOTRONIC Intelligent

OT 100/ /700 P5

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

HID control gear Electronic

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Technical Information

Indoor Linear 80W Driver SI-C215280N2KR

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

Emergency lighting units EM INVERTER

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

15 Series - Dimmer

LED MODULES READYLINE DL

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

OPTOTRONIC FIT. Product family datasheet. Linear / Area Constant Current Non dimmable. Areas of application. Product benefits.

Catalogue Ignitors and power switches for HID

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

IK10 IP68. Specifications. White (4 300 K typical) Warm white (3 000 K typical) Blue (470 nm) Other colors by request

Gamma instabus. Technical product information

Benefits. Applications

Figure 1: Device components

Fluxe 90 LV/RGB Adjustable

AF-300 E11 Adjustable Frequency Drive

Dimming actuators GDA-4K KNX GDA-8K KNX

Luminaire installation box Surface-mounted box Ceiling installation box

HELVAR. CONTROLLABLE ELECTRONIC BALLASTS DALI & 1-10 V controllable ballasts STANDARD ELECTRONIC BALLASTS

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Electrical connection

Datasheet - SRB-E-201ST

Professional-Practice

Linear Probe Encoder Page 1 of 7. Description. Features

Magnetic Sensor - Incremental EHP

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

K-BUS Dimmer Module User manual-ver. 1

MICROMASTER Encoder Module

QUICKTRONIC FIT 8. Product family datasheet. ECG for FL 26 mm

Operating Instructions Dimmer for V Incandescent Lamps

Kuhnke Technical Data. Contact Details

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: IP Rating: Cable: Connector:

QTi DALI 2X14/24/ DIM

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Photoelectrics Through-beam Type PA18C.T..., DC

INSTALLATION & USER GUIDE

t LED Signage Solutions

Switching Power Module

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

R xx-C0900-J074

Linear flow controls VFC Linear flow controls with actuator IFC

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Tri-level Control HF Sensor

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

ADJUSTABLE SPEED DRIVES. nc1 Drive

02/11/2015

SH2RE16A4. Output relay module. Benefits. Description

DOB Series PHI33. EdiPower III. Dim to Warm 230V Datasheet. Introduction :

Datasheet - SRB301LC 24VAC/DC

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

ODW-621. RS-232 Point-to-point applications

Product Manual. ABB i-bus EIB / KNX Switch/Dim Actuators SD/S. Intelligent Installation Systems ABB

Ordering details. Approval. Classification

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Supply voltage 230 V AC Service button 1. Power connector Light track contacts Service LED 1, red

EM1. Transmissive Optical Encoder Module Page 1 of 9. Description. Features

Input Control. Input Voltage Range. Model. 2 Vin - 0.2~0.5V % SLD-DimTW V 2 2 Vin - 0.2~0.5V 5. 7 SLD-DimTW

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

Transcription:

Product description 1-channel for indoor use Inbuilt for luminaires of protection class I Output current and output voltage adjustable FA output 12 V TC input channel ominal life of 50,000 h (at ta max. with a failure rate of 5 %) Dimmable via 1... 10 V, potentiometer or PUSH function (incl. Memory function) 1 Overload protection 5 Thermal protection 5 Plastic casing, black Technical data Rated supply voltage 220 240 V Input voltage range, AC 99 264 V Mains frequency 50 / 60 Hz Rated current (at 230 V / 50 Hz / full load) 0.29 A Typ. efficiency (at 230 V / 50 Hz / full load) 90 % λ (at 230 V / 50 Hz) 0.98 eakage current (PE) 0.34 ma Control input 1... 10 V, potentiometer 100 kω and PUSH function 2 Stand-by power (at 230 V / 50 Hz) < 1 W Max. output voltage 3 55 V Dimming range 0 100 % PWM frequency 220 240 Hz Set up time at 230 V 600 ms Switch-off time (at full load) 100 ms FA output, voltage 12 V FA output, current 4 50 ma Max. casing temperature tc 85 C Max. casing temperature tc (at lifetime 50,000 h) 80 C Dimensions xwxh 110 x 76 x 30 mm CI 55 W 1400 ma O010 TOP series B Ø4,4 17 Ordering data tc 70 99 64 H Type Article number Packaging carton Packaging pallet Weight per pcs. CI 055/1400 O010 24166470 40 pc(s). 1,600 pc(s). 0.225 kg Data sheet 04/13-C020-1 www.tridonic.com 1

Specific technical data Type Output Tolerance Typ. power Output voltage range Max. output current Operating temperature ta CI 055/1400 O010 1 PUSH function is not compatible to switchdim. 2 1... 10 VDC source with double or reinforced insulation with respect to AC mains. Max. source current: 0.35 ma. 3 o-load operation. 4 Max. permitted inrush current: 100 ma. 5 On overload and over temperature the output power will be reduced. 6 Ripple 5 Vpp. 7 Operation with TAEXXmodule SPOT TS 310 / TS320 / TS 325 possible. See page 4. 1,050 ma ±6 % 45 W 2 44 V -25... 50 C 1,200 ma ±5 % 52 W 2 44 V -25... 50 C 1,400 ma (default) ±5 % 55 W 2 39 V -25... 50 C 1,600 ma ±5 % 55 W 2 35 V -25... 50 C 1,750 ma ±5 % 55 W 2 30 V -25... 50 C 2,100 ma ±5 % 55 W 2 26 V -25... 45 C 48 V 7 ±10 % 6 55 W 1,150 ma -25... 50 C Data sheet 04/13-C020-1 www.tridonic.com 2

Standards E 50172 E 55015 E 61000-3-2 E 61347-1 E 61347-2-13 E 61547 E 62384 Dimming Dimming range 1 % to 100 % Control with: PUSH function Potentiometer 1... 10 V 1... 10 V function The light intensity of the EDs vary proportionally to the signal sent to the terminal. Intensity is null with a signal less than 1 V. Potentiometer function By rotating the potentiometer there is variation of the ED light intensity in a proportionate or logarithmic way depending on the model of potentiometer used. The use of a logarithmic potentiometer is recommended. PUSH function Integrated Push function allows a direct dimming via push button. Push button must be connected between the terminal block (PUSH) and Phase (). Maximum 10 driver in series controlled by one or more push buttons. The maximum length of push cables is 15 m. Brief push (<1 s) switches the device O and OFF. The device switch-o at light level set at switch-off When the push button is held (>1 s), the devices are dimmed. After repush the device is dimmed in the opposite direction. The use of the push button inhibits the use of the signal. To return to use of the signal keep the signal less than 0,5 V for at least 2 seconds. PUSH function (memory mode) If the mains isn t switched off and the switching on/off is done by a momentaryaction switch (push button) then the ED driver will start again at the same level it was. Maximum forward voltage ote: It s not allowed to connect ED modules with a higher forward voltage then declared, otherwise the will be over loaded and the expected nominal life time will be reduced. This issue isn t covered by the warranty. Synchronisation A maximum of 10 devices in series can be controlled with a momentary-action switch, potentiometer or interface. Only one master device is permitted. (1 master 9 slaves) The maximum cable length for synchronisation between the devices should not exceed 4 m. PUSH-Synchronisation If more than one device is operated with a single key during PUSH operation, asynchronous behaviour can occur, which will require manual resynchronisation using the method described. It is recommended not to control more than four devices using a single key. Should this be unacceptable, a synchronisation cable will have to be used instead. Any 1-key dimmer that does not feature a central control module (as each driver will have its own controls) can develop asynchronous behaviour (e.g. children might play with the key). The system will then be out of sync, i.e. some lamps will be on, others off or the dimming direction will differ from lamp to lamp. If the drivers are switched on, press the PUSH key for more than one second (long PUSH) followed with a short push (<1 s). ow the devices are switched off, do a long PUSH, the system will now be resynchronised. The PUSH function is not compatible to switchdim. The wiring of the PUSH function and switchdim is not exchangeable. I-Set The I-Set function allows the limitation of the upper dimming level. For the exact resistor value and dimming level please refer to the following diagram. The I-Set function cannot be used with DAI. For limitation of the upper dimming level please use DAI command 42 (store the DTR as Maxevel). dimming level [%] 100 80 60 40 20 0 0 5*104 1*105 1.5*105 2*105 2.5*105 3*105 resistor value (R) [Ω] Data sheet 04/13-C020-1 www.tridonic.com 3

Maximum loading of automatic circuit breakers Automatic circuit breaker type C10 C16 B10 B16 Inrush current Installation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 1.5 mm 2 I max Pulse CI 055/1400 O010 31 51 18 30 10 A 200 µs Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in % Type THD 3 5 7 9 11 CI 055/1400 O010 12 11 3 1 1 1 Wiring guidelines The cables should be run separately from the mains connections and mains cables to ensure good EMC conditions. The ED wiring should be kept as short as possible to ensure good EMC (max. 5 m recommended). The does not have polarity reversal protection on the secondary side. ED modules that do not have polarity reversal protection may be damaged if polarity is reversed. Thermic sensor TC value Start operation temperature (3 V Req = 26 kω) Total switch-off temperature (2,2 V Roff = 15 kω) 100 K 55 C 72 C 150 K 65 C 80 C 220 K 75 C 90 C Component tolerances are not considered. Storage conditions Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) Storage temperature: 0 C up to max. 50 C The devices have to be within the specified temperature range (ta) before they can be operated. Glow wire test according to E 60598-1 650 C passed. Information about the correct handling of EDs can be found in the u brochure Installation instructions and guidelines Ê www.tridonic.com Wiring type and cross section Input terminal () / PUSH / q Please use only one wire per spring terminal. wire preparation: 0.5 1.5 mm² 8 9 mm Output terminal (SEC) Please use only one wire per screw terminal. Max. torque: 0.4 m wire preparation: 0.5 2.5 mm² 6 7 mm Please use only one wire per screw terminal. Max. torque: 0.4 m wire preparation: 0.2 1.5 mm² 4.5 6.5 mm Connection SPOX from Molex Plug for cable (art. no. Molex: 0022433020) SEC- / SEC / FA / I-SET / TC / GD Plug for cable (art. no. Molex: 0022433060) Data sheet 04/13-C020-1 www.tridonic.com 4

Wiring diagram or potentiometer Wiring diagram PUSH function CI 55 W 1400 ma O010 CI 55 W 1400 ma O010 SEV PUSH Max. 10 devices in series (1 Master 9 Slaves) SEC FA I-SET TC GD 1 SEV 1 common ground (GD) for FA, I-SET and TC - PUSH Wiring diagram TAEXXmodule SPOT TS310 / TS320 / TS325 / Potentiometer For operation with TAEXXmodule SPOT TS310 / TS320 / TS325 a capacitor (47 µf / 100 V) has to be switched to the output in parallel. Dip SWITCH position has to be connected to 48 V. SEC TC FA 12 V PUSH 0 V 48 V 6 5 4 3 2 GD 1 VDC CI 55 W 1400 ma O010 CI 55 W 1400 ma O010 SEV PUSH PUSH Max. 10 devices in series (1 Master 9 Slaves) SEC FA I-SET TC GD 1 SEV 1 common ground (GD) for FA, I-SET and TC MU CI 55 W 1400 ma O010 TAEXXmodule SPOT TS 3xx O SEC SEC- FA I-SET - TC GD 1 O SEC- O SEC SEC- FA I-SET - TC GD 1 O SEC- - PUSH Data sheet 04/13-C020-1 www.tridonic.com 5

Dip SWITCH position Output Position 1,050 ma 1,200 ma O 1,400 ma (default) O O 1,600 ma O O O 1,750 ma O O O O 2,100 ma O O O O O 48 V O O O O O Before use, always check Dip SWITCH setting. Data sheet 04/13-C020-1 www.tridonic.com 6