GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

Similar documents
GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application

GV2P05. Main. Device short name. Device application

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

A V 50Hz / V 60Hz

TeSys circuit-breakers

Series CT7N Bimetallic Overload Relays

AS09..S 3-pole Contactors - Spring Terminals

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB-E-201ST

Ordering details. Approval. Classification

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Magnecraft Power Relays

Type: DILM25 10(24V50HZ) Article No.:

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Safety dialogue solutions

Type: DILM12 10(24VDC) Article No.:

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

02/11/2015

Bulletin 190 IEC Modular Starter System

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Circuit-Breakers for Motor Protection Series 8523/8

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Modular pulse operated latching relay 16 A

Manual Motor Starter Specifcations

Power Circuit of a UL508A Panel. Typical UL489 Application

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

Minicontactorrelay,2NO/2NC,DCoperated

High performance circuit breakers

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

16 A and 25 A power contactors with or without handle

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

llen-bradley 194R-HM4-NFPA3

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

DMX and 4000 air circuit breakers from 800 to 4000 A

Magnetic and Hydraulic-Magnetic Circuit Breaker

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Data Sheet Definite Purpose Contactors Ex9CK Series

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

POWER FACTOR CORRECTION

ALLEN BRADLEY TIMING RELAY

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Interface Relays and Optocouplers Product group picture

Capacitors and banks 50 Hz 0 400/415 V network voltage

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

LED Driver Compact dimming

Circuit breakers BZM. Circuit breakers BZM

EXPlora. Introduction

Variable speed drives Altivar Process Three-phase supply voltage: V 50/60 Hz Wall-mounting drives

Kuhnke Technical Data. Contact Details

EMC Solutions Noise filtering

LED control gear Compact fixed output

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

LED Driver Linear / area fixed output

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

LED Driver Compact fixed output

OT 100/ /700 P5

50 Hz 60 Hz VOLTAGE Connections

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

Nessie Coils for VDH and VDHT valves

Pluggable interface relays CR-M Miniature relays

Transcription:

Product data sheet Characteristics GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - lugs-ring terminals Main Range Product name Device short name Device application Trip unit technology Complementary Poles description Network type TeSys TeSys GV2 GV2ME Motor Thermal-magnetic Utilisation category AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode Operating position Motor power kw 3P AC Clipped on 35 mm symmetrical DIN rail Screwed on panel (with adaptor plate) Any position 3 kw at 690 V AC 50/60 Hz 1.1 kw at 400/415 V AC 50/60 Hz 1.5 kw at 400/415 V AC 50/60 Hz 1.5 kw at 500 V AC 50/60 Hz 2.2 kw at 500 V AC 50/60 Hz 2.2 kw at 690 V AC 50/60 Hz Breaking capacity 3 ka Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 ka Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 ka Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 ka Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 ka Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service short-circuit breaking capacity Control type Apr 18, 2019 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Push-button 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

[In] rated current Thermal protection adjustment range Magnetic tripping current 4 A 2.5...4 A 51 A [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ith] conventional free air thermal current 4 A conforming to IEC 60947-4-1 [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 60947-2 Power dissipation per pole Mechanical durability Electrical durability Operating rate 2.5 W 100000 cycles 100000 cycles for AC-3 at 440 V 25 cyc/h Rated duty Continuous conforming to IEC 60947-4-1 Connection pitch Connections - terminals Tightening torque 13.5 mm without spreader Lugs-ring terminals external diameter : 9.5 mm Bars 6 x 9.5 mm 1.7 N.m on lugs-ring terminals M4 screw type 1.7 N.m on bars M4 screw type Suitability for isolation Yes conforming to IEC 60947-1 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Height Width Depth Product weight 89 mm 45 mm 78.2 mm 0.26 kg Environment Standards EN 60204 IEC 60947-1 IEC 60947-2 IEC 60947-4-1 NF C 63-120 NF C 63-650 NF C 79-130 UL 508 VDE 0113 VDE 0660 CSA C22.2 Product certifications Protective treatment ATEX BV CCC CEBEC CSA DNV EZU GL LROS (Lloyds register of shipping) RINA SETI TSE UL EAC IP degree of protection IP20 conforming to IEC 60529 IK degree of protection TH IK04 Ambient air temperature for operation -20...60 C Ambient air temperature for storage -40...80 C Fire resistance 960 C conforming to IEC 60695-2-1 Operating altitude 2000 m 2

Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 0635 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference contains SVHC above the threshold - Go to CaP for more details Go to CaP for more details Available Product Environmental Profile Need no specific recycling operations Contractual warranty Warranty period 18 months 3

Product data sheet Performance Curves GV2ME086 Thermal-Magnetic Tripping Curves for GV2ME and GV2P Average Operating Times at 20 C Related to Multiples of the Setting Current 1 3 poles from cold state 2 2 poles from cold state 3 3 poles from hot state Current Limitation on Short-Circuit for GV2ME and GV2P (3-Phase 400/415 V)) Dynamic Stress I peak = f (prospective Isc) at 1.05 Ue = 435 V 4

1 Maximum peak current 2 24-32 A 3 20-25 A 4 17-23 A 5 13-18 A 6 9-14 A 7 6-10 A 8 4-6.3 A 9 2.5-4 A 10 1.6-2.5 A 11 1-1.6 A 12 Limit of rated ultimate breaking capacity on short-circuit of GV2ME (14, 18, 23, and 25 A ratings). Thermal Limit on Short-Circuit for GV2ME Thermal Limit in ka 2 s in the Magnetic Operating Zone Sum of I 2 dt = f (prospective Isc) at 1.05 Ue = 435 V 5

1 24-32 A 2 20-25 A 3 17-23 A 4 13-18 A 5 9-14 A 6 6-10 A 7 4-6.3 A 8 2.5-4 A 9 1.6-2.5 A 10 1-1.6 A 6

Product data sheet Dimensions Drawings GV2ME086 Dimension GV2ME (1) Maximum X1 Electrical clearance = 40 mm for Ue 690 V GV2ME 89 GV2ME 3 101 b Mounting GV2ME On 35 mm rail c = 78.5 on AM1 DP200 (35 x 7.5) c = 86 on AM1 DE200, ED200 (35 x 15) On panel with adapter plate GV2AF02 On pre-slotted plate AM1 PA On rails DZ5 MB201 7

GV2AF01 Combination GV2ME + TeSys k contactor GV2AF3 Combination GV2ME + TeSys d contactor GV2ME + LC1D09 D18 LC1D25 and D32 b 176.4 186.8 c1 94.1 100.4 c 99.6 105.9 GV2AF4 + LAD311 Combination GV2ME + TeSys d contactor GV2ME + LC1D09 D18 LC1D25 and D32 b 176.4 186.8 c1 103.1 136.4 c 135.6 141.9 d1 107 107 d 112.5 112.5 GV2ME + GV1L3 (Current Limiter) 8

X1 = 10 mm for Ue = 230 V or 30 mm for 230 V < Ue 690 V 9

Product data sheet Connections and Schema GV2ME086 GV2ME and GV2RT Connection of Undervoltage Trip for Dangerous Machines (Conforming to INRS) on GV2ME Only 10