CF-4700 FFT Comparator Comparator Setting Operation

Similar documents
Getting Started with the LabVIEW Sound and Vibration Toolkit

Activity P32: Variation of Light Intensity (Light Sensor)

Activity P27: Speed of Sound in Air (Sound Sensor)

An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR

Analyzing and Saving a Signal

The Measurement Tools and What They Do

What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven

HST Neural Coding and Perception of Sound. Spring Cochlear Nucleus Unit Classification from Spike Trains. M.

DDA-UG-E Rev E ISSUED: December 1999 ²

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display

E X P E R I M E N T 1

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

Experiment 13 Sampling and reconstruction

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

Troubleshooting Your Design with the TDS3000C Series Oscilloscopes

User Manual VM700T Video Measurement Set Option 30 Component Measurements

Pre-processing of revolution speed data in ArtemiS SUITE 1

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

Experiment P32: Sound Waves (Sound Sensor)

How to Optimize Ad-Detective

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

Operating Instructions

Torsional vibration analysis in ArtemiS SUITE 1

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Getting started with Spike Recorder on PC/Mac/Linux

Using an oscilloscope - The Hameg 203-6

DETECTING ENVIRONMENTAL NOISE WITH BASIC TOOLS

(Skip to step 11 if you are already familiar with connecting to the Tribot)

Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR

Standard Operating Procedure of nanoir2-s

Patchmaster. Elektronik. The Pulse generator. February 2013

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Major Differences Between the DT9847 Series Modules

Vision Sensor Short Manual

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

Field Test 2. Installation and operation manual OPDAQ Installation and operation manual

University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope

Topic: Instructional David G. Thomas December 23, 2015

PicoScope for Windows user guide Chapter 1: Overview Chapter 2: Views Chapter 3: How To.. Chapter 4: Menus Chapter 5: Dialogs

Performing a Measurement/ Reading the Data

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

DT9837 Series. High Performance, USB Powered Modules for Sound & Vibration Analysis. Key Features:

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

Lab experience 1: Introduction to LabView

RG NDT INTERNATIONAL INC

BER MEASUREMENT IN THE NOISY CHANNEL

Basic Operations App Guide

SigPlay User s Guide

Linrad On-Screen Controls K1JT

The EEGer 4.3 Tutorial

Calibrating Measuring Microphones and Sound Sources for Acoustic Measurements with Audio Analyzer R&S UPV

Remote Director. Apple 23 LCD Display. Collaborative Soft Proofing using the I. MANUFACTURER INTRODUCTION. SWOP Application Data Sheet

DAT335 Music Perception and Cognition Cogswell Polytechnical College Spring Week 6 Class Notes

Oscilloscopes, logic analyzers ScopeLogicDAQ

EAN-Performance and Latency

Detect Color and Shape for various inspection

System Requirements SA0314 Spectrum analyzer:

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Automated Limit Testing

HARDWARE INSTRUCTION MANUAL MULTI-CHANNEL SIGNAL ANALYZER SA-02M 4-CHANNEL SIGNAL ANALYZER SA-02A4

#PS168 - Analysis of Intraventricular Pressure Wave Data (LVP Analysis)

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

Oscilloscope Reference Manual CS300

BioGraph Infiniti Physiology Suite

Practicum 3, Fall 2010

9070 Smart Vibration Meter Instruction Manual

PulseCounter Neutron & Gamma Spectrometry Software Manual

Draft Baseline Proposal for CDAUI-8 Chipto-Module (C2M) Electrical Interface (NRZ)

Oscilloscope Reference Manual CS300

Agilent Technologies 54522A

Logic Analysis Basics

Remote Director. EIZO ColorEdge CG21. Collaborative Soft Proofing using the I. MANUFACTURER INTRODUCTION. SWOP Application Data Sheet

Logic Analysis Basics

Short Manual. ZX2 Short Manual.doc Page 1 of 12

LeCroy Digital Oscilloscopes

BASIC TUTORIAL. Jocelyn Mariah Kremer, Mike Mullins Documentation BIOPAC Systems, Inc. William McMullen Vice President BIOPAC Systems, Inc.

CAEN Tools for Discovery

DPX Acquisition Technology for Spectrum Analyzers Fundamentals. Primer

MTL Software. Overview

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

A low noise multi electrode array system for in vitro electrophysiology. Mobius Tutorial AMPLIFIER TYPE SU-MED640

MONITORING AND ANALYSIS OF VIBRATION SIGNAL BASED ON VIRTUAL INSTRUMENTATION

MachineryMate 800 operating guide Handheld vibration meter

RF Record & Playback MATTHIAS CHARRIOT APPLICATION ENGINEER

University of Utah Electrical Engineering Department EE1050/1060 Oscilloscope. Name:, Lab TA:

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

Activity P42: Sound Waves (Power Output, Sound Sensor)

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Overview. Signal Averaged ECG

SREV1 Sampling Guide. An Introduction to Impulse-response Sampling with the SREV1 Sampling Reverberator

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

USER MANUAL. A4400 VA4 Pro A4404 SAB with Virtual Unit

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

Full Disclosure Monitoring

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

PicoScope. User guide. Copyright 2005 Pico Technology Limited. All rights reserved. PSW044 v1.5

Transcription:

CF-4700 FFT Comparator Comparator Setting Operation

-Contents- 1. Block comparator 2. Shape comparator (Time-axis waveform) 3. Tracking waveform shape comparator 2

Overview of the Comparator Function CF-4700 is a pass/fail judgment equipment used on production lines that is highly effective in quality check by analyzing sound or vibration from products or parts. Block comparator function: This function is for the pass/fail judgment from the level of frequency signal. Shape comparator function: This function is for pass/fail judgment by waveform shape. Tracking function&shape comparator: This function is for pass/fail judgment by level according to the rotation speed fluctuation. 3

1. Block comparator Block comparator is the function that makes judgments by checking whether the peak value or level of a target signal satisfies specific conditions in the block (area) within a specified frequency and level range. 4

1-1 Block comparator setting method 1. Connect the sensor and main unit (CF-4700). 2. When you use the CCLD type sensor, the power is supplied directly from the main unit. In this case, please turn the CCLD ON. Home Input Input Cond Turn ON the CCLD. Touch here to display setting screen. 5

1-2 Y-axis engineering unit setting 1. When you use the accelerometer (1 mv/m/s2), input the calibration value. Home Input EU Activate the button. Input 0.001 by using the palette. Select or input the unit name. 6

2. When you calibrate the microphone by the sound calibrator, switch the screen to EU/SP, and perform calibration after measuring the standard signal. Home Input EU Touch EU/SP to switch the screen. Set the unit name to perform measurement (average). Select the cursor to the overall value. Perform calibration after averaging. 7

1-3 Y-axis scale adjustment Select Lin/Log Home Display Y Scale Lin/Log Arbitrary select of Y-axis scale Home Display Y Scale Scale Mode Select Manual, and select lower limit value Lower or select upper limit value Upper Y-axis scale, etc.: The Y-axis scale can be selected arbitrary by double clicking the screen, and those values are fixed. 8

1-4 Block comparator judging method Block setting Upper limit level 1 LEVEL Lower limit frequency value Lower limit level Upper limit frequency value The result is judged to be OK (pass) if the waveform does not exceed the specified block, and NG (fail) if it exceeds the specified block. OK 2 PK.MAX (Peak max) NG The result is judged to be OK if the waveform peak does not exceed the specified block and it is largest in the block, if not, it is judged to be NG. OK NG NG NG 9

3 AREA (Occupation area) It judges by the occupation area of the waveform in the specified block. 4 P.O (Partial overall) It judges by the partial overall value within the specified block. Upper limit Lower limit 5 PK.LEVEL (Peak level) The result is judged to be OK if the max. value of waveform does not exceed the frequency range of upper or lower level of specified block, if not, it is judged to be NG. OK OK NG OK NG 10

1-5 Judgment method setting (Select LEVEL) 1. Select Block Comparator from Graph Type: Home Comp Type Block Comp 2. Select P.O. from the Judgment Method: Block Setting Select Graph View to switch the display to the Judge method setting screen. Select Block Setting. Select P.O. 11

3. Set the judgment block: Create block by dragging the stylus pen. After creating the block, touch [REGISTER] for registration. Register Button When you want to create multiple blocks, maximum 20 blocks can be registered. The register number is updated when you touch REGISTER button after creating block. 12

The judgment area (block) can be set not only on the graph but also on the list. Create the block by directly inputting the numerical value of the specified section. Touch to display the list. NG NUM COMP LIMIT COMP METHOD X LOWER X UPPER Y LOWER Y UPPER Input the count number (1 or larger) of NG Set if the levels of upper/lower, upper and lower areas are validated or not. Select judgment method from 6 types Set the lower limit frequency value of the area. Set the upper limit frequency value of the area. Set the lower limit level of the area Set the upper limit level of the area. 13

1-6 Executing the judgment 1. To judge while displaying the measurement screen, turn [Graph Mode] ON. 2. In this manual, set as follows: NG Num: 1/ Limit: U&L/ Method: P.O. Judgment is operated by the partial overall value within the selected block, if it judges NG at least once, NG is kept displayed. 2Comparator function is validated when the COMP is turned ON. 1Select Comp 14

<Judgment result example> In this manual, the result is judged to be OK if the peak does not exceeds the block range, and NG if it exceeds the block range. When it judges NG at least once, NG is kept displayed. Number of blocks: No1 519 times NG judgment Number of judgment 15

1-7 Setting of judgment condition (select single mode) Single mode: Judges every time the [COMP] button is touched. 1. Select [Single Compare] from the judgment method: Home Comp Comp Cond Single Compare Validates the Single Compare. One judgment is performed every time [COMP] button is touched. When it turns OFF, continuous judgment mode is selected. Once the judgment is performed, [COMP] button is turned OFF. Judgment is performed when touch [COMP] button again. 16

2. Set the Compare Condition: Home Comp Comp Cond Compare Timer:Set the start time and compare time of judgment. Start Delay:Set the waiting time until the judgment is performed after touching the [Comp] button. Compare Time: Set the time of operating the judgment. Activate the NG Result Clear. It automatically cleared the judgment results when next measurement is started. 17

2. Shape comparator (Time-axis waveform) 2-1 Time waveform display Set the voltage range, frequency range to display the time waveform. Voltage range Frequency range 2-2 Shape comparator setting method Set the mode to shape mode. Select Home Comp Type in this order to select Shape Comp. 18

2-3 Condition setting 1. Select Shape Setting. Select Shape Setting. In this manual, top and bottom judgment criteria is set to the time waveform graph. 19

2. Select Home Comp Shape Cond in this order to select Graph View. The point you touch first will be the starting point of a judgment line, at which the shape comparator editing cursor (rectangle) appears. Next, when you touch any point on the screen, a line appears on the graph from the starting point to the point you touch. When you finish drawing a judgment line, touch [REGISTER] button for registration. It is easy to draw a straight line by using the [Start] and [End] buttons. When the [Start] button is touched, the point is moved to left end and drew a straight line. When the [End] is touched, the point is moved to right end and drew a straight line. Limit OVER:When amplitude is in + side of judgment line, it judges NG. UNDER: When amplitude is in side of judgment line, it judges NG. Upper figure: example of setting the judgment reference in upper and lower limit. 20

3. Select Shape Setting in this order to select Inversion. When the soft key [Inversion] is touched, the time waveform judgment line of plus side is inversion displayed to minus side. The judgment line can be set top and bottom of the time waveform. Prepare the two types of judgment references: 1 2 Blue line: Judgment of plus side. When the waveform is exceeded the upper line, it judges as NG. Set the Limit to OVER. Red line: Judgment of minus side. When the waveform is lower the lower line, it judges as NG. Set the Limit to OVER. 21

2-4 Comparison of the time summation averaged time waveform 1. Trigger function is necessary to perform time summation averaging. Home Input Trigger Trigger Set 2. Select Repeat form the Mode. The data is acquired every time the rigger is applied. 3. Select Internal from [Source]. The trigger is applied to the measurement signal in Internal. Select Home Input Trigger in this order to select Int Trigger. 4. Select the level and position of the trigger. Set the level and position of the trigger. 22

5. Set the time summation averaging processing: Home Measurement Average 6. Select Time Sum from the [Mode]. 7. Select Count from the [Type]. 8. Select number of averaging from [Count]. 9. Touch [COMP], [TRIG] and [AVG] to set the condition to trigger waiting state. 23

3. Tracking waveform shape comparator 3-1 Tracking analysis setting 1. Touch Home Measurement in this order to select Schedule. Perform tracking setting in this screen. Set the measurement rotation range (Lower, Upper) and measurement rotation interval. Also, lower the screen and set the sampling condition and max. analysis order. 24

2. Set the rotation pulse for the tracking analysis: Touch Home Measurement in this order to select Schedule. The rotation pulse is able to be set in the setting screen by touching the RotationCond. After setting, check if the rotation speed is displayed in the upper right of Rev. The rotation pulse can be set in the RotationCond when the tracking is performed. Set the number of pulses (Pulse Count) in one rotation, threshold value (Detection Level) and coupling. 25

3. Switch the screen to tracking analysis screen. Change the Graph Type. When the Schedule is selected, the screen is changed. 4. Touch Home Display Schedule in this order to select Trace Line. 26

5. Set the tracking diagram (trace line) to be displayed: Touch Home Display Schedule in this order to select Trace Line. Select the trace line (order component) to be displayed. In this manual, first order component and overall value (O.A) are displayed. 27

3-2 Execute the tracking analysis Touch the [SHED] button, then touch[ START] button. The measurement is started when the rotation speed is reached to the selected value. 28

3-3 Tracking analysis judgment line setting Touch Shape Setting in this order to set Graph View. Please refer to the shape comparator setting method for this setting. Touch the screen to select the judgment line. Then touch [REGISTER] to register the judgment line. 29

3-4 Execute the tracking analysis judgment Touch [SCHED] and [COMP] button, then touch [START] button. When perform judgment after displaying the tracking results, activate the [Single Compare] by touching [Home] [Comp] [Comp Cond] in this order. The judgment is executed when the [COMP] button is touched after the measurement. 30