DP DI. GEO M12 Series GEOM1210-I GEOM1220-I. User manual

Similar documents
DP DI. GEO M12 Series GEOM1210 GEOM1220. User manual

E15X-SUB Manual (1.2 EN)

LIVERPOOL TLX43. Custom-Engineered Drivers

PRAGUE TPZ122/64. # Designed and engineered in the U.K.

MAW218D7. User s manual. Pol.Ind.Norte-Perpinyà, TERRASSA (Barcelona-SPAIN)

DRM212 DRM215 DRM315 SPECIFICATIONS

XCELLENCE SERIES X-15LTP

S-Series Configurations

MAD A-Series...Flat Panel Surface Planar Arrays

NuQ102 ## ## for FOH, sidefill and delay line loudspeakers, and is an exceptional choice for wedge monitoring applications.

NuQ152-WH # # connector plate carries Neutrik speakon* NL4 connectors for input and link connections to additional enclosures.

OWNER'S MANUAL MYCRO SUB

RoomMatch RM and RM TECHNICAL DATA SHEET. asymmetrical array modules. Key Features. Product Overview. Technical Specifications

Portable Speakers. 2 Way 15" Full Range Loudspeaker for Portable PA and Installation Applications

A-Line LOUDSPEAKER SYSTEM. Mobile Audio Concert Sound Fixed Installation Pro Entertainment. English

front: 6.25"(159mm) W x 9.25"(235mm) H rear: 5.625"(143mm) W x 9.25"(235mm) H depth: 7"(178mm)

TOUR SERIES LOUDSPEAKER SYSTEMS

TKT122. # Designed and engineered in the U.K. Precision and Detailed Clarity

Portable Speakers. 2 Way 12" Full Range Loudspeaker for Portable PA and Installation Applications

The 2 way full range TKT102 is a 1,200 Watt 10" loudspeaker system. applications. Engineered for either permanent installation or portable

The 2 way full range TKT122 is a 2,000 Watt 12" loudspeaker system. applications. Engineered for either permanent installation or portable

DUBLIN TCX102 ## ## Custom-Engineered Drivers

Manchester - England. BRT-12 Datasheet

Custom-Engineered Drivers

Portable Speakers. Dual 2 Way 15" Full Range Loudspeaker for Portable PA and Installation Applications

ART 7 SERIES PROFESSIONAL ACTIVE SUBWOOFERS. a new generation of speakers is born and it s ready to rock audiences all over the world

e 935 Instruction manual Stage Microphones

The 3-way full range TKT105 is a 600 Watt 10" loudspeaker system

e 835 Instruction manual Stage Microphones

CBT 70J Constant Beamwidth Technology

ER-100 Eurorack 8 Channel Stereo, Transformer Balanced Out Summing Mixer User Manual

RoomMatch Utility RMU208 TECHNICAL DATA SHEET. small-format foreground/fill loudspeaker. Key Features. Technical Specifications

I SERIES Point Source 800 IP8-1122/66 HIGH POWER 12-INCH TWO-WAY 60 x 60 INSTALLATION LOUDSPEAKER

UB22z Specifications. 2-WAY COMPACT FULL-RANGE See NOTES TABULAR DATA for details CONFIGURATION Subsystem DESCRIPTION

DEEPFRAME BASIC KIT- USER MANUAL VERSION ORIGINAL USER MANUAL

Portable Speakers. 2,500 Watt 2 Way 8" Powered Loudspeaker with KLARK TEKNIK DSP Technology, Speaker Modelling and ULTRANET Networking

Concert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

e 604 Instruction manual Stage Microphones

Portable Speakers. 2,500 Watt 2 Way 15" Full Range Powered Loudspeaker with KLARK TEKNIK DSP Technology and ULTRANET Networking

18 (300mm) ultra-high excursion cone transducer, 4" (100mm) voice coil, ferrite magnet

I SERIES Compact 600 IC6-2082/96 HIGH OUTPUT DUAL 8-INCH TWO-WAY 90 x 60 INSTALLATION LOUDSPEAKER

UNPACKING. Check the contents of the carton to identify the following items: 4 x satellite speakers 1 x centre channel speaker

Panaray 802 Series III TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

Small Room Solutions. High-Quality, Cost-Effective Cinema Audio Products for Small Room Applications

APS W 12 inch. APS W 15 inch. 2 Way Active PA System with 3 Channel Mixer. 2 Way Active PA System with 3 Channel Mixer.

DSP 18 Sub active subwoofer. user manual

Genelec 2029B Digital Monitoring System. Operating Manual

iq15 Portable 2500 Watt 2 Way 15" Powered Loudspeaker with KLARK TEKNIK DSP Technology, Speaker Modelling and ULTRANET Networking

I SERIES Point Source 600 IP6-1122/26 MEDIUM POWER 12-INCH TWO-WAY 120 x 60 INSTALLATION LOUDSPEAKER

LA1500R USER S GUIDE.

USER MANUAL. GOLDMUND LOGOS 1N-2N SPEAKER SYSTEM Active Speaker

Warnings and Precautions

QSA 200i. ACTIVE LOUDSPEAKER user manual

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

CBT 100LA Constant Beamwidth Technology

QB Series USER MANUAL V Installation range. Versatile Sound reinforcement. High Performance. Precise band pass directivity control

Distributed Design Series

Con o t n e t n e t n s t

NewScope-7A Operating Manual

BERLIN TBV123-AN. Custom-Engineered Drivers

DEEPFRAME BASIC KIT- USER MANUAL VERSION ORIGINAL USER MANUAL

NuQ102-AN-WH. Portable Speakers. 600 Watt 2 Way 10" Full Range Powered Loudspeaker with KLARK TEKNIK DSP Technology and ULTRANET Networking (White)

SRM W 15" Portable Powered Subwoofer

PL2410W LCD Monitor USER'S GUIDE.

install applications.

SMART CINEMAHORIZONTAL. User Guide VPSP Projector side. model. Notice SmartCrystal Cinema MUV V1R0

AMS 8DC. Weather-Resistant Enclosure

ATHENS TCS122/96-AN. Install Speakers

Designed to excel in a wide variety of sound reinforcement applications, the full range DVS 6-WH is an ultracompact 240-Watt surface mount

DVS 4 # # Superb Point-Source Performance

CPH-10 SUBWOOFER OWNERS MANUAL

Reveal 402 / 502 / 802. English Manual

G.R.A.S. Sound & Vibration

CONTENTS: Thank You CAUTION:

SMS4124 SMS4940 SMS4990 Compact Two-Way Loudspeakers

Manchester - England. TRS-118A Datasheet

NuQ152-AN ## ## Portable Watt 2 Way 15" Full Range Powered Loudspeaker with KLARK TEKNIK DSP Technology and ULTRANET Networking

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

VK-P10SE WARRANTY REGISTRATION FORM

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

TABLE OF CONTENTS Important Safety Instructions Package Content Setting Up the Display Trouble shooting Specifications Product Dimensions

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

.Prompter Kit for Apple ipad. TP-200

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Venue Performance Series VP Array Guide

SB60 airsound BASE USER S GUIDE. version 1.0

Portable Speakers. 3,000 Watt 18" Powered Subwoofer with KLARK TEKNIK DSP Technology, Speaker Modelling and ULTRANET Networking

AMS 6ICT. Weather-Resistant Enclosure

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

10.4" LCD Monitor with Aluminum Front Bezel YPM1040PHB

Winmate Communication INC.

Q-TV2. User Manual. for Screens

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

BM5 mkiii Owner s manual

PLL2210MW LED Monitor

Prodipe DSP UHF systems and microphones

P-2 Installing the monitor (continued) Carry out as necessary

NS-B750. Speaker Enceinte OWNER S MANUAL MODE D EMPLOI BEDIENUNGSANLEITUNG MANUAL DE INSTRUCCIONES

VITEK VTM-TLM191 VTM-TLM240

Transcription:

DP2818-01-DI GEO M12 Series GEOM1210-I GEOM1220-I User manual

CONTENU CONTENU CONTENU 2 WARNINGS 3 DESCRIPTION 4 PRESET GEOM12 5 GEOM12 RIGGING 9 GEOM12 ACCESSORIES 10 ARRAY EQ 12 MAINTENANCE 13 TECHNICAL SPECIFICATIONS 15 USER NOTES 16 EU Conformity declaration We, Declare under our sole responsibility that the product Type Serial number Is in conformity with the provisions of the following directive including all applicable amendments: Applied rules and standards: Plailly, January, 2019 NEXO SA ZA DU PRE DE LA DAME JEANNE 60128 PLAILLY France Loudspeaker GEOM12 On the product 2014/35/UE (Low Voltage Directive) EN 13155, EN 62368 Joseph CARCOPINO, R&D Director Page 2 / 20 GEOM1210-I - GEOM1220-I

WARNINGS WARNINGS PRECAUTIONS Do not open the speaker, do not try to disassemble it neither to modify it in any way. The system doesn t include any userrepairable part. If the system seems to be malfunctioning or damaged, stop using it at once and have it repaired by a NEXO qualified technician. Do not expose the system directly to the sun or to the rain, do not immerse it into fluids, do not place objects filled with liquid on the system. If a liquid gets into the system, please have it inspected by a NEXO qualified technician. The connection should be performed by qualified technician, by ensuring that power is off. Operating temperature with temperate climate: 0 C to +40 C (+32 F to +104); -20 C à +60 C (-4 F to +140 F) for storage. Read this manual before using the speaker. Keep this manual available for further reference. Observe all warnings and cautions. SAFETY INFORMATIONS Please check the NEXO Web site nexo-sa.com to get the most up-to-date version of this manual. Ensure you are aware of the safety rules applying to rigging, stacking or installing on tripod or speaker stand. Failure to observe these rules may expose persons to potential wounds or even death. Only use the system with accessories specified by NEXO. Please always consult a NEXO-accredited technician if the installation needs architectural works and observe following precautions: Mounting Precautions: - Please select screws and mounting location supporting 4 times the system weight. - Do not expose the system to excessive dust, vibrations, to extreme cold or hot temperatures, to reduce the risk of damaging components. - Do not place the system in an unstable position: it could fall accidentally. - If the system is used on a tripod, please ensure the tripod s specifications are adapted and that it s height does not exceed 1.40m/55. Do not move the tripod with the system in position. Connection and Powering Precautions: - Unplug connected cables before moving the system. - Power off the system before connecting the system. - When switching on the installation, the amplifier must be powered last; when switching the installation off, shut off the amplifier first. - If you work by cold temperatures, progressively raise the level to nominal value during the first minutes of use, to allow the system components to stabilize. Please check regularly the system condition. HIGH SOUND PRESSURE LEVELS Exposure to very high sound pressure levels may cause permanent hearing losses. Degrees of hearing losses may be different from one person to another, but almost everybody will be affected if exposed to high sound pressure levels during a long period of time. The OSHA (Occupational Safety and Health Administration) American Agency specified the following maximal exposures: Number of Hours Sound Pressure Level (dba), Slow Response 8 90 6 92 4 95 3 97 2 100 1 ½ 102 1 105 ½ 110 ¼ or less 115 WASTE OF ELECTRIC OR ELECTRONIC EQUIPMENT This symbol on the product or its packaging indicates that this product must not be treated as household waste. Instead, it is your responsibility to hand it over to a designated collection point for the recycling of waste electrical and electronic equipment. By ensuring your waste equipment is recycled, you will help prevent potential negative consequences for the environment and human health, which could appear if this product was not recycled. Recycling helps spare natural resources. For more information about the recycling of this product, please contact your local city office, your household waste disposal service or your reseller. GEOM1210-I - GEOM1220-I Page 3 / 20

DESCRIPTION DESCRIPTION GEOM1210-I and GEOM1220-I are a mid-size line array, 2 ways active/passive, with a 12 LF and a 1.4 HF. You can change the HF horizontal directivity from 80 to 120 by adding a pair of magnetic flanges. The GEOM12 can be stacked of flown with the HF waveguide exit on the left or the right side of the front panel, allowing to broaden or narrow the stereo image depending on your need and the characteristics of the venue. We recommend to build system with the HF waveguide on the outside of each assembly (larger stereo image). GEOM1210-I: 10 vertical dispersion GEOM1220-I: 20 vertical dispersion Versions: GEOM1210-I: fix installations; Black GEOM1210-IPW: fix installations; White GEOM1220-I: fix installations; Black GEOM1220--PW: fix installations; White Connectors: GEOM1210-I/1220-I: two cable-glands (clamping range, Ø 10 to 17mm), four fast connectors behind the plate. - Remove the connecting plate. - Pass the cables through the cable-gland. - Connect to the fast connectors: ACTIVE o LF (+) Red / (-) Black. o HF (+) Orange / (-) Grey PASSIVE: (+) Orange / (-) Grey - Tight the cable-gland and remount the connecting plate. Amplification: The GEOM12 cabinets MUST be used with a NEXO processor to handle EQ, phase alignment, crossover and excursion/thermal protection for the system loudspeakers. The following table shows the number of GEOM12 usable with each solution. NXAMP4x1(bridged) NXAMP4x2 NXAMP4x4 GEOM12 Up to 2 per channel 1 per channels Up to 3 per channel Recommended Page 4 / 20 GEOM1210-I - GEOM1220-I

PRESET GEOM12 PRESET GEOM12 Please consult nexo-sa.com for NEXO TD Controllers firmware information. For the GEOM1210 or GEOM1220, with or without directivity flanges, the following setups are available: Passive Mode o Setup for one stand-alone box, with high-pass at 50, 60, 75, 85, 95 or 120 Hz. o Setup for arrays from 2 to 3 boxes, with high-pass at 50, 60, 75, 85, 95 or 120 Hz. o Setup for arrays from 4 to 6 boxes, with high-pass at 50, 60, 75, 85, 95 or 120 Hz. o Setup for arrays from 7 to 12 boxes, with high-pass at 50, 60, 75, 85, 95 or 120Hz. o Setup for Stack Monitor, with high-pass at 50, 60 or 75 Hz. Active Mode o Setup HF for arrays from 2 to 3 boxes, 1 khz 20 khz o Setup HF for arrays from 4 to 6 boxes, 1 khz 20 khz o Setup HF for arrays from 7 to 12 boxes, 1 khz 20 khz o o o Setup LF for arrays from 2 to 3 boxes, 50, 60, 75, 85, 95 or 120 Hz to 1kHz. Setup LF for arrays from 4 to 6 boxes, 50, 60, 75, 85, 95 or 120 Hz to 1kHz. Setup LF for arrays from 7 to 12 boxes, 50, 60, 75, 85, 95 or 120 Hz to 1kHz. 1 Box ox Default Cross over on one box 50 Hz Front Fill, multi-diff, sound reinforcement all short throw application; High SPL Small system using 2x GEOM12 and 2x MSUB18 in 85 Hz; GEOM1210-I - GEOM1220-I Page 5 / 20

PRESET GEOM12 2 Boxes For small flying or stacking configuration, mid throw application used at 60 Hz without MSUB18 and default 85 Hz with MSUB18 at 85 Hz too. Possibilities to use 2-3Box setup in stack configuration using MSUB18 in OMNI or CARDIO mode with 1 Back and 2 Front and 3 GEOM12 on top of them, application venue up to 25 meters, default cross over 85 Hz but small overlap could have impact if needed, for example (MSUB18 120Hz and GEOM12 75 Hz). Page 6 / 20 GEOM1210-I - GEOM1220-I

PRESET GEOM12 4-6 Boxes For long throw flying application used in GEOM12 at 60 Hz without sub and GEOM12 at 85 Hz with flying MSUB18 in omni mode at 95 Hz. For long throw stacking application on floor or on MSUB18, up to 6 boxes used at 60 Hz without Sub and 85 Hz with MSUB18 at 85 Hz. GEOM1210-I - GEOM1220-I Page 7 / 20

PRESET GEOM12 7-12 Boxes For very long throw stacking application used with Sub either ground stack or flying, recommended MSUB18 cardioid mode, cross over MSUB18 95 Hz and 12 GEOM12 cross over 75 Hz for maximum impact. Don t forget to put HF Waveguide either to the exterior or the interior of the venue. Ground Stack Sub design Page 8 / 20 GEOM1210-I - GEOM1220-I

GEOM12 RIGGING GEOM12 RIGGING Assembly Front Positioning 2x GEOM12-I. Connect both cabinets by inserting the axis through front holes and secure axis with brake nuts. Back Adjust the appropriate inter-angle value with the Linkbar and secure with the provided screws. Screws: 1 shoulder screw (D10x20), 2 washers (M10), 1 brake nut (M8). GEOM1210-I - GEOM1220-I Page 9 / 20

GEOM12 ACCESSORIES GEOM12 ACCESSORIES WARNINGS All GEOM12 accessories are specifically rated in agreement with structural computations. Never use other accessories including push-pins when assembling GEOM12 cabinets than the ones provided by NEXO: NEXO will decline responsibility over the entire GEOM12 accessory range if any component is purchased from different supplier. All GEOM12 accessories have been designed so that cabinet are arrayed vertically. GEOM12 horizontal assemblies as shown in figure below are UNSAFE and STRICTLY PROHIBITED VNI-BUMPM12 / VNT-BUMPM12 Rated for a maximum of 12 GEOM12 or 8 MSUB18, or a combination with a maximum of 4 MSUB18 and 6 GEOM12. Flown on 2 rigging points with retractable rings. Usable with VNT-EXBARM12 for extra tilt angle and flown on one or two rigging points. Ground stack assembly alone, or with VNT-GSTKM10M12S / VNT-GSTKM10M12L for adding stability. 2 locations for laser/clinometer (VNT-BUMPM12 only). VNT-EXBARM12 Page 10 / 20 GEOM1210-I - GEOM1220-I

GEOM12 ACCESSORIES VNT-GSTKM10M12S VNT-GSTKM10M12L VNT-MNSTKM12 Rated for a maximum of 3 GEOM12 on the top of MSUB18. GMT-LBUMPM12 Rated for a maximum of 12 GEOM12. Usable with GMT-EXBARM12L for a one rigging point. GMT-EXBARM12L GMT-FLGM12 Pair of flanges for 120 horizontal directivity. No tools, magnetic clamp. GEOM1210-I - GEOM1220-I Page 11 / 20

ARRAY EQ ARRAY EQ The ArrayEQ allows to adjust the system frequency response in its lower range (see curves below, with different ArrayEq values): Page 12 / 20 GEOM1210-I - GEOM1220-I

MAINTENANCE MAINTENANCE Front panel disassembly 1 Remove the 4 screws (Tx25) to remove the grille. 2 Remove the front panel (10 screws Tx25) 3 To remove the HF Driver, unscrew the 4 nuts, and remove it from the wave guide. 4 To remove the 12 driver, remove the 8 screws (Tx25). Pay attention to the 4 spacers below the PMP. Tightening torque for the 12 : 3.5 Nm GEOM1210-I - GEOM1220-I Page 13 / 20

MAINTENANCE Spare parts MARK QUANTITY REFERENCE DESIGNATION 1 2 05LEXM1210 Lexan GEOM1210 black 2 05LEXM1210-PW Lexan GEOM1210 white 2 05LEXM1220 Lexan GEOM1220 black 2 05LEXM1220-PW Lexan GEOM1220 white 2 1 05LEXWAR1 Lexan Warning 1 05LEXWAR1-PW Lexan Warning White 3 1 05LEXRIG-ANGL1 Lexan Rigging Angles 1 05LEXRIG-ANGL1-PW Lexan Rigging Angles White 4 1 05LEXCNX-M1210-I Lexan CNX GEOM1210-I 1 05LEXCNX-M1210-IPW Lexan CNX GEOM1210-I White 1 05LEXCNX-M1220-I Lexan CNX GEOM1220-I 1 05LEXCNX-M1220-IPW Lexan CNX GEOM1220-I White 5 1 05GEOM12UA-I Complete grille Installation Black 1 05GEOM12UA-IPW Complete grille Installation White 6 1 05NH78TN-16 HF Driver complete (with screws) 1 05NH78TN-16-RK HF Diaphragm 7 1 05HPB12PN-8 12 Driver 1 05HPB12PN-8-RK Recone kit HPB12PN-8 Page 14 / 20 GEOM1210-I - GEOM1220-I

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GEOM12 WITH NEXO ELECTRONICS Model Frequency range (±6dB) 50Hz 20kHz Sensibility (1W / 1m) 105dB SPL Nominal Peak SPL Level (1m) 140dB Operating voltage 50 Vrms (180 Vpeak) GEOM12 Vertical Dispersion Horizontal Dispersion Crossover Frequency Nominal Impedance Recommended Amplification 10 for GEOM1210 20 for GEOM1220 80 or 120 (with magnetic flanges GMT-FLGM12) LF-HF : 1.1kHz Passive Active mode: (8Ω LF - 16Ω HF) Passive mode: 8 Ω Active mode: (1250W LF + 650W HF) Passive mode: 1250 W per cabinet CARACTÉRISTIQUES Model Components Material Finish Front finish GEOM12 LF: 1x 12-8Ω - Long excursion Neodymium driver with PDD TM HF: 1x3 voice coil 1.4 throat driver on a BEA/FEA optimized HRW TM Lightweight polyurethane composite Black or white structural paint Black or white acoustic fabric fitted front steel grille Fittings 2 Side handles horizontal Back grip Connectors Weight 2 x cable gland with 4 cores cables 34 kg 75 lb Dimensions GEOM1210-I - GEOM1220-I Page 15 / 20

USER NOTES USER NOTES Page 16 / 20 GEOM1210-I - GEOM1220-I

USER NOTES GEOM1210-I - GEOM1220-I Page 17 / 20

USER NOTES Page 18 / 20 GEOM1210-I - GEOM1220-I

USER NOTES GEOM1210-I - GEOM1220-I Page 19 / 20

USER NOTES NEXO S.A. Parc d activité de la Dame Jeanne F-60128 PLAILLY Tel: +33 3 44 99 00 70 Fax: +33 3 44 99 00 30 E-mail: info@nexo.fr nexo-sa.com Page 20 / 20 GEOM1210-I - GEOM1220-I