4040C COMMUNICATION MODULE

Similar documents
4X70 PROFINET SYSTEM

4X50 ETHERNET SYSTEM

2070 PROFINET MODULE

4x50 User s guide Modbus TCP

2x50 ETHERNET MODULE

Instruction manual Alfa Laval PROFINET weighing module

Instruction manual for system with digital load cells MCE2035 PROFIBUS DP MODULE

Instruction manual for system with digital load cells

CC-Series 7-Segment Configuration

5024 WEIGHING TERMINAL

Extra long-range RFID (proximity) card reader

Configuration Vestas VMP3500

TABLE OF CONTENTS. Instructions:

Operating Instructions Rev. No. 4.1 July 07, LTC and VITC Reader with Serial Interface TC 60 RLV

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Kramer Electronics, Ltd. USER MANUAL. Model: FC Analog Video to SDI Converter

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

Instruction manual for 5024 Weighing Terminal

CEDES. Functional description CEDES 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN)

Applied Measurements Ltd

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Model VS-2A 2-Port VGA Switch with Audio & Serial Control

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

Modbus for SKF IMx and Analyst

Wind Indicator LED. Contents. Instruction for Use xx.x00, x08, xx.10

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

For warranty service, please contact Microframe at: A technician will gladly assist you.

medlab One Channel ECG OEM Module EG 01000

IV 251. Signal Converter SSI Analogue and SSI Serial. Operating Instructions. control motion interface

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

SignalTap Plus System Analyzer

SC-IO-24 Smart Communication IO Module User Manual

RS-232C External Serial Control Specifications

APPLICATION NOTE VACUUM FLUORESCENT DISPLAY MODULE

ZU 252. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

Operators Manual. TeleWeigh Wired. Model: by Fairbanks Scales, Inc All rights reserved Revision 1 09/07

Wind Indicator LED. Contents. Instruction for Use xx.x01

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

C8188 C8000 1/10. digital audio modular processing system. 4 Channel AES/EBU I/O. features. block diagram. 4 balanced AES inputs

EEG A1452 SCTE-104 Inserter Frame Card

ET-REMOTE DISTANCE. Manual of ET-REMOTE DISTANCE

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

PT9232. Heavy Industrial RS232 Communication

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

Technical Manual. Model 7266 Master and Model 7266 Slave

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

PT9232. Heavy Industrial RS232 Communication

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

4-DIGIT & 6-DIGIT "U" SERIES TIME CODE READERS OPERATION AND MAINTENANCE MANUAL

Teletext Inserter Firmware. User s Manual. Contents

TZM883. Manufacturing & Warehouse

DMC550 Technical Reference

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

DRV050-VGA-R02 Drive Board User manual Ver 1.1

LCD STIMULUS DISPLAY for ENV-007/008 CHAMBERS

3-in 1- out DVI Switcher

Kramer Electronics, Ltd. USER MANUAL. Models: VS-162AV, 16x16 Audio-Video Matrix Switcher VS-162AVRCA, 16x16 Audio-Video Matrix Switcher

Sundance Multiprocessor Technology Limited. Capture Demo For Intech Unit / Module Number: C Hong. EVP6472 Intech Demo. Abstract

Agilent 11713A Attenuator/Switch Driver

IV 251. Signal Converter SSI => Analogue and SSI => Serial. Operating Instructions. control motion interface

DRAFT RELEASE FOR BETA EVALUATION ONLY

ILDA Image Data Transfer Format

Users guide for PB units Interface unit, 4- or 6-digit

Kramer Electronics, Ltd. USER MANUAL. Model: VS-201YC. 2x1 s-video Switcher

AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio

Vorne Industries. 2000B Series Buffered Display Users Manual Industrial Drive Itasca, IL (630) Telefax (630)

DX-10 tm Digital Interface User s Guide

Kramer Electronics, Ltd. USER MANUAL. Models: VS-626, 6x6 Video / Audio Matrix Switcher VS-828, 8x8 Video / Audio Matrix Switcher

P42XP10-BK Installation Guide 42 Plasma Monitor Rev 1.2

I N S T R U C T I O N D A T A

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Options: Date Received: Software Revision: (manual not accurate for prior to "C1")

Viewing Serial Data on the Keysight Oscilloscopes

Laboratory Exercise 4

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes

ILDA Image Data Transfer Format

SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA

LE-650s Instruction Manual

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Model 974A Quad Counter/Timer Operating Manual

with Simulated Outputs Description Applications Features

Technical Description

Universal DiSEqC controller USER MANUAL

Universal DiSEqC controller USER MANUAL SAT CONTROL

Kramer Electronics, Ltd. USER MANUAL. Model: CV / YC to SDI Converter

Serial Peripheral Interface

User Manual KUNBUS-PRS

Model P/03P Upconverters

Options: Date Received: Software Revision:

Training Note TR-06RD. Schedules. Schedule types

Rfid Based Attendance System

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

VLT AutomationDrive FC 301/FC 302

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

Transcription:

Kokkedal Industripark 4 DK-2980 Kokkedal Denmark info@eilersen.com Tel +45 49 180 100 Fax +45 49 180 200 4040C COMMUNICATION MODULE BIN communication in a 4x40C system Applies for: Program no.: BIN_1LC.130307.0 Document no.: 0307mu4040CE-0.DOC Date: 2013-03-11 Rev.: 0

1) CONTENTS 1) CONTENTS...2 2) INTRODUCTION...3 2.1 Introduction...3 3) DATA EXCHANGE...4 3.1 BIN Mode (Binary Mode)...4 3.2 Polled/Continuous operation...4 3.3 Protocol description...5 3.3.1 Read Weight telegram...6 3.3.2 Set Mode telegram...7 3.3.3 Set Resolution telegram...8 3.3.4 Set Average Period telegram...9 3.3.5 Set Filter Number telegram...10 3.3.6 Telegram examples...11 3.4 Loadcell status codes...12 3.5 Filtering...13 4) HARDWARE DESCRIPTION...14 4.1 4x40C front panel...14 4.1.1 Connection of power...14 4.1.2 Connection of loadcells...14 4.1.3 Connection of external units with J2 connector...14 4.1.4 SW1 settings...15 4.1.5 Light Emitting Diodes (LEDs)...15 4.2 4040C communication module...16 4.2.1 SW2 settings...16 4.2.2 Jumper settings...17 4.2.3 Light Emitting Diodes (LEDs)...17 4.2.4 JTAG connector...17 Version: 2013-03-11, rev.: 0 Page: 2

2) INTRODUCTION 2.1 Introduction This document describes the use of a 4040C communication module from Eilersen Electric, when it is equipped with the program listed on the front page. With the program specified on the front page, the 4040C communication module is capable of transferring weight data from a connected loadcell on an RS485 channel using a binary protocol. By use of DIP switches it is possible to select the resolution (0,1 gram or 1 gram) by which the weight is represented. By use of DIP switches it is possible to configure the averaging period to 2, 10, 50 or 100 ms. By use of DIP switches it is possible to include one of 15 different FIR filters, that will be used to filter the loadcell signal. By use of communication on the RS485 channel it will be possible to change the default power-up settings (determined by DIP switches) for communication mode, resolution, averaging period and filter number used. The external device will typically be a PC, that is connected through a RS485 to USB converter. Version: 2013-03-11, rev.: 0 Page: 3

3) DATA EXCHANGE 3.1 BIN Mode (Binary Mode) The 4040C module will communicate with the following specifications: Specification: RS485 (2-wire) Baudrate: 115200 bps Data bits: 8 Parity: None Stop bits: 1 Protocol: Master-Slave BIN protocol as described below 3.2 Polled/Continuous operation The 4x40C system unit can be set to either Polled or Continuous operation. This is done using Sw2.8 as described later. This can be changed during operation by using a Set Mode request telegram (see protocol description). In Polled operation the 4040C module operates as described in the next chapter; i.e. it only transmits its Read Weight response telegram when it receives a Read Weight request telegram from its RS485 master. In Continuous operation the 4040C module automatically transmits its Read Weight response telegram upon completion of every averaging period; i.e. the 4040C module does NOT need to receive a Read Weight request telegram from its RS485 master. NOTE: If the 4040C module is placed in Continuous operation the RS485 master should aim at performing transmissions in between transmissions made by the 4040C module. This is in order to avoid conflicts on the RS485 bus. If this is not possible retransmissions by the RS485 master are necessary until the telegram slips through to the 4040C module. NOTE: If the 4040C module is placed in Continuous operation, the only request telegram allowed to be transmitted by the RS485 master, and which the 4040C module will respond to, is a Set Mode request telegram requesting the 4040C module to enter Polled operation. All other request telegrams send by the RS485 master will be ignored by the 4040C module. Version: 2013-03-11, rev.: 0 Page: 4

3.3 Protocol description The 4x40C system unit communicates with the external equipment using a master-slave binary protocol where the 4x40C system unit acts as a slave. All valid request telegrams from the RS485 master will be acknowledge with a corresponding response telegram. All telegrams, request as well as response telegrams, are encapsulated by a start character (<STX> = ASCII 02h) and an end character (<ETX> = ASCII 03h). In addition all telegrams contain a checksum (<BCC>). Hence all telegrams have the following format: <STX> <specific telegram contents> <BCC> <ETX> The checksum is calculated by logical XOR of all preceding characters in the telegram including the <STX> character; i.e. the <BCC> itself and the <ETX> character are not included. The following request telegrams are available: Request Telegram Read Weight Set Mode Set Resolution Set Average Period Set Filter Number Telegram Format <STX> W <BCC> <ETX> <STX> M <number> <BCC> <ETX> <STX> R <number> <BCC> <ETX> <STX> A <number> <BCC> <ETX> <STX> F <number> <BCC> <ETX> The specific request and their corresponding response telegrams are described in detail in the following. Version: 2013-03-11, rev.: 0 Page: 5

3.3.1 Read Weight telegram The 4x40C system unit is capable of receiving a Read Weight request telegram. The telegram is used to read the status and weight of the loadcell. The telegram is ONLY allowed when Polled operation is selected. The Read Weight request telegram has the following format: <STX> W <BCC> <ETX> Apart from the start, checksum and end characters the request telegram contains: W is a W character (ASCII 57h). When the 4x40C system unit receives a Read Weight request telegram (or whenever the average period expires in Continuous operation), a Read Weight response telegram is transmitted from the 4x40C system unit as an acknowledge. The Read Weight response telegram has the following format: <STX> <SS 1 > <WWWW 1 > <BCC> <ETX> Apart from the start, checksum and end characters the response telegram contains: SS x WWWW x Status value for loadcell(x). The value is a 2 byte (one word 16 bit unsigned integer) binary number with MSB first indicating the status code of loadcell(x). Weight value for loadcell(x). The value is a 4 byte (one double word 32 bit signed integer) binary number with MSB first indicating the current weight signal in the selected resolution for loadcell(x). The value is the result of the latest completed averaging. Version: 2013-03-11, rev.: 0 Page: 6

3.3.2 Set Mode telegram The 4x40C system unit is capable of receiving a Set Mode request telegram. The telegram is used to switch between Polled and Continuous operation overwriting the default poweron value set using Sw2.8. The telegram is used when Polled as well as when Continuous operation is selected. The Set Mode request telegram has the following format: <STX> M <number> <BCC> <ETX> Apart from the start, checksum and end characters the request telegram contains: M <number> is a M character (ASCII 4Dh). is a 1 byte binary number (0-255) indicating the desired mode. A value of 0 corresponds to Polled operation, and a value of 1 corresponds to Continuous operation. All other values are invalid. When the 4x40C system unit receives a Set Mode request telegram, a Set Mode response telegram is transmitted from the 4x40C system unit as an acknowledge. The Set Mode response telegram has the following format: <STX> m <number> <BCC> <ETX> Apart from the start, checksum and end characters the response telegram contains: m <number> is a m character (ASCII 6Dh). is a 1 byte binary number (0-255) indicating the actual mode. A value of 0 corresponds to Polled operation, and a value of 1 corresponds to Continuous operation. All other values are invalid. Version: 2013-03-11, rev.: 0 Page: 7

3.3.3 Set Resolution telegram The 4x40C system unit is capable of receiving a Set Resolution request telegram. The telegram is used to set the desired resolution overwriting the default power-on value set using Sw2.6. The telegram is ONLY allowed when Polled operation is selected. The Set Resolution request telegram has the following format: <STX> R <number> <BCC> <ETX> Apart from the start, checksum and end characters the request telegram contains: R <number> is a R character (ASCII 52h). is a 1 byte binary number (0-255) indicating the desired resolution. A value of 0 corresponds to 1 gram resolution, and a value of 1 corresponds to 0,1 gram resolution. All other values are invalid. When the 4x40C system unit receives a Set Resolution request telegram, a Set Resolution response telegram is transmitted from the 4x40C system unit as an acknowledge. The Set Resolution response telegram has the following format: <STX> r <number> <BCC> <ETX> Apart from the start, checksum and end characters the response telegram contains: r <number> is a r character (ASCII 72h). is a 1 byte binary number (0-255) indicating the actual resolution. A value of 0 corresponds to 1 gram resolution, and a value of 1 corresponds to 0,1 gram resolution. All other values are invalid. Version: 2013-03-11, rev.: 0 Page: 8

3.3.4 Set Average Period telegram The 4x40C system unit is capable of receiving a Set Average Period request telegram. The telegram is used to set the desired average period overwriting the default power-on value set using Sw2.4-Sw2.5. The telegram is ONLY allowed when Polled operation is selected. The Set Average Period request telegram has the following format: <STX> A <number> <BCC> <ETX> Apart from the start, checksum and end characters the request telegram contains: A <number> is a A character (ASCII 41h). is a 1 byte binary number (0-255) indicating the desired average period. A value of 0 corresponds to 2 ms, a value of 1 corresponds to 10 ms, a value of 2 corresponds to 50 ms and a value of 3 corresponds to 100ms. All other values are invalid. When the 4x40C system unit receives a Set Average Period request telegram, a Set Average Period response telegram is transmitted from the 4x40C system unit as an acknowledge. The Set Average Period response telegram has the following format: <STX> a <number> <BCC> <ETX> Apart from the start, checksum and end characters the response telegram contains: a <number> is a a character (ASCII 61h). is a 1 byte binary number (0-255) indicating the actual average period. A value of 0 corresponds to 2 ms, a value of 1 corresponds to 10 ms, a value of 2 corresponds to 50 ms and a value of 3 corresponds to 100ms. All other values are invalid. Version: 2013-03-11, rev.: 0 Page: 9

3.3.5 Set Filter Number telegram The 4x40C system unit is capable of receiving a Set Filter Number request telegram. The telegram is used to set the desired filter number overwriting the default power-on value set using Sw1.1-Sw1.4. The telegram is ONLY allowed when Polled operation is selected. The Set Filter Number request telegram has the following format: <STX> F <number> <BCC> <ETX> Apart from the start, checksum and end characters the request telegram contains: F <number> is a F character (ASCII 46h). is a 1 byte binary number (0-255) indicating the desired filter number. The number can have a value of 0-15 corresponding to the 15 different filters (and 0 for no filtering). All other values are invalid. When the 4x40C system unit receives a Set Filter Number request telegram, a Set Filter Number response telegram is transmitted from the 4x40C system unit as an acknowledge. The Set Filter Number response telegram has the following format: <STX> f <number> <BCC> <ETX> Apart from the start, checksum and end characters the response telegram contains: f <number> is a f character (ASCII 66h). is a 1 byte binary number (0-255) indicating the actual filter number. The number can have a value of 0-15 corresponding to the 15 different filters (and 0 for no filtering). All other values are invalid. Version: 2013-03-11, rev.: 0 Page: 10

3.3.6 Telegram examples The following is a list of telegram examples (i.e. requests with corresponding responses): Telegram type Request Response Read Weight <02h> <57h> <55h> <03h> <02h> <00h> <00h> <00h> <00h> <00h> <81h> <83h> <03h> Set Mode <02h> <4Dh> <00h> <4Fh> <03h> <02h> <6Dh> <00h> <6Fh> <03h> Set Resolution <02h> <52h> <00h> <50h> <03h> <02h> <72h> <00h> <70h> <03h> Set Average Period <02h> <41h> <00h> <43h> <03h> <02h> <61h> <00h> <63h> <03h> Set Filter Number <02h> <46h> <00h> <44h> <03h> <02h> <66h> <00h> <64h> <03h> Version: 2013-03-11, rev.: 0 Page: 11

3.4 Loadcell status codes The following loadcell status codes are possible. If more than one error condition is present the status codes are OR ed together. CODE CAUSE (Hex) 0001 Reserved for future use 0002 Reserved for future use 0004 Reserved for future use 0008 Reserved for future use 0010 Reserved for future use 0020 Reserved for future use 0040 No answer from loadcell Bad connection between loadcell and 4040C? 0080 Reserved for future use 0100 Reserved for future use 0200 Reserved for future use 0400 Reserved for future use 0800 No loadcell answer Bad connection between loadcell and 4040C? 1000 Reserved for future use 2000 Reserved for future use 4000 Reserved for future use 8000 Reserved for future use Version: 2013-03-11, rev.: 0 Page: 12

3.5 Filtering By use of DIP-switches it is possible to include one of 15 different FIR filters, that will be used to filter the loadcell signals. Thus it is possible, to send the unfiltered loadcell signals achieved over each averaging/sample period (Tavg) through one of the following FIR filters, before the results are transmitted on the RS485 channel: SW1.1 SW1.2 SW1.3 SW1.4 No. Taps Tavg 2ms Frequency Tavg 10ms Tavg 50ms Tavg 100ms Damping OFF OFF OFF OFF 0 - - - - - - ON OFF OFF OFF 1 7 120 Hz 24 Hz 4.8 Hz 2.4 Hz -60dB OFF ON OFF OFF 2 9 100 Hz 20 Hz 4.0 Hz 2.0 Hz -60dB ON ON OFF OFF 3 9 120 Hz 24 Hz 4.8 Hz 2.4 Hz -80dB OFF OFF ON OFF 4 12 80 Hz 16 Hz 3.2 Hz 1.6 Hz -60dB ON OFF ON OFF 5 12 100 Hz 20 Hz 4.0 Hz 2.0 Hz -80dB OFF ON ON OFF 6 15 80 Hz 16 Hz 3.2 Hz 1.6 Hz -80dB ON ON ON OFF 7 17 60 Hz 12 Hz 2.4 Hz 1.2 Hz -60dB OFF OFF OFF ON 8 21 60 Hz 12 Hz 2.4 Hz 1.2 Hz -80dB ON OFF OFF ON 9 25 40 Hz 8 Hz 1.6 Hz 0.8 Hz -60dB OFF ON OFF ON 10 32 40 Hz 8 Hz 1.6 Hz 0.8 Hz -80dB ON ON OFF ON 11 50 20 Hz 4 Hz 0.8 Hz 0.4 Hz -60dB OFF OFF ON ON 12 64 20 Hz 4 Hz 0.8 Hz 0.4 Hz -80dB ON OFF ON ON 13 67 15 Hz 3 Hz 0.6 Hz 0.3 Hz -60dB OFF ON ON ON 14 85 15 Hz 3 Hz 0.6 Hz 0.3 Hz -80dB ON ON ON ON 15 100 10 Hz 2 Hz 0.4 Hz 0.2 Hz -60dB NOTE: With all four switches OFF, no filtering is performed. NOTE: The default power-on filter number (0-15) selected using DIP switches can be changed during operation by using a Set Filter Number request telegram (see protocol description). Version: 2013-03-11, rev.: 0 Page: 13

4) HARDWARE DESCRIPTION 4.1 4x40C front panel This chapter describes the connections, DIP-switch settings and lamp indications that are available on the 4x40C front panel. 4.1.1 Connection of power The 4x40C system unit is powered by applying +24VDC on a two pole connector as specified on the front panel of the 4x40C system unit. This powers the 4040C communication module as well as the loadcells. 4.1.2 Connection of loadcells The loadcells must be connected to the available BNC connectors in the front panel of the 4x40C system unit. The loadcells are connected starting with the connector marked 1 and continuing onwards in rising order. Thus if three loadcells are to be connected, they should be connected to the BNC connectors marked 1, 2 and 3. 4.1.3 Connection of external units with J2 connector The 4040C module is connected to an external unit with the J2 connector with these connections: J2 pin. Function Connected to 1 B (-) RS485-B (-) please see below 2 A (+) RS485-A (+) please see below 3 I/O Not connected 4 GND Gnd Please notice that in some external systems (especially German) the use of A and B is switched. The use of + and markings are always the same Version: 2013-03-11, rev.: 0 Page: 14

4.1.4 SW1 settings The front panel of the 4x40C system unit is equipped with a 4 pole DIP switch block named SW1. Please note that unless stated otherwise, these switches are ONLY read during power-on. These switches are mounted on the 4040C communication module. SWITCH Sw1.1-Sw1.4 FUNCTION Filtering Used to select the desired filter as described in an earlier chapter. Note that these switches are read during power-on ONLY. NOTE: The default power-on filter number (0-15) selected using DIP switches can be changed during operation by using a Set Filter Number request telegram (see protocol description). 4.1.5 Light Emitting Diodes (LEDs) The front panel of the 4x40C system unit is equipped with a number of status lamps (light emitting diodes). The lamps that are mounted on the 4040C communication module have the following functionality: LED TxLC (Yellow) TxBB (Right - Green) LC1 (Red) LC2 (Red) LC3 (Red) LC4 (Red) FUNCTION 4040 communication with loadcells Lit when communicating with the connected loadcells. 4040 communication Lit when communicating externally. Status for loadcell #1 Lit if the connection to loadcell #1 is broken. Status for loadcell #2 Lit if the connection to loadcell #2 is broken. Status for loadcell #3 Lit if the connection to loadcell #3 is broken. Status for loadcell #4 Lit if the connection to loadcell #4 is broken. Version: 2013-03-11, rev.: 0 Page: 15

4.2 4040C communication module This chapter describes the connections, DIP-switch settings and status lamps (LEDs) that are available internally on the 4040C communication module. 4.2.1 SW2 settings The 4040C communication module is internally equipped with a 8 pole DIP switch block named SW2. Please note that these switches are ONLY read during power-on. This DIP switch block has the following function: Sw2.1 Sw2.2 Sw2.3 Number of loadcells OFF OFF OFF 1 ON OFF OFF 1 OFF ON OFF 1 ON ON OFF 1 OFF OFF ON 1 ON OFF ON 1 OFF ON ON 1 ON ON ON 1 Sw2.4 Sw2.5 Averaging period (Tavg) OFF OFF 2 ms ON OFF 10 ms OFF ON 50 ms ON ON 100 ms NOTE: The default power-on value for averaging period selected using DIP switches can be changed during operation by using a Set Average Period request telegram (see protocol description). Sw2.6 OFF ON Resolution 1 gram (i.e. 1 equals 1 gram) 0,1 gram (i.e. 1 equals 0,1 gram) NOTE: The default power-on value for resolution selected using DIP switches can be changed during operation by using a Set Resolution request telegram (see protocol description). SWITCH Sw2.7 FUNCTION Reserved for future use SWITCH Sw2.8 FUNCTION Polled/Continuous operation OFF: Polled operation (see protocol description) ON: Continuous operation (see protocol description) NOTE: The default power-on value for mode selected using DIP switches can be changed during operation by using a Set Mode request telegram (see protocol description). Version: 2013-03-11, rev.: 0 Page: 16

4.2.2 Jumper settings The 4040C communication module is internally equipped with 4 jumpers named P2, P3, P4 and P5. In this system these jumpers must be set as follows: JUMPER P2 P3 P4 P5 POSITION OFF (Loadcell connected to 4040C NOT accessible using SEL1) OFF (Loadcell connected to 4040C NOT accessible using SEL6) OFF (Loadcell connected to 4040C NOT accessible using SEL1) OFF (Loadcell connected to 4040C NOT accessible using SEL6) 4.2.3 Light Emitting Diodes (LEDs) The 4040C communication module is internally equipped with a number of status lamps (light emitting diodes). The lamps have the following functionality: LED D11 (Red) D12 (Red) D13 (Yellow) D14 (Yellow) FUNCTION Reserved for future use Reserved for future use Reserved for future use Reserved for future use 4.2.4 JTAG connector The 4040C communication module is internally equipped with a JTAG connector. The connector (J4) is used exclusively by Eilersen Electric A/S for download of software to the Cygnal processor. Version: 2013-03-11, rev.: 0 Page: 17