Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors

Similar documents
SU17 Series Fiber Optic Sensors

Photoelectric Sensors E3F2

Specifications. Response Time. Status Indicators. Scanning Range/Resolution. Vibration. Shock. Physical Characteristics.

D12 Expert Series TEACH-Mode Fiber Optic Sensors

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Electrical connection

Cylindrical Photoelectric Sensor CY-100 SERIES

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Safety Light Curtains GuardShield

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Linear Array with Intensity Adjustment

Photoelectrics Through-beam Type PA18C.T..., DC

LED Series Sealed Backlights

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

EZ-SCREEN. Type 4 Point-of-Operation V-Series No configuration necessary; preconfigured for Trip Output, Scan Code 1, MACHINE SAFETY

Technical data. General specifications. Indicators/operating means

EZ-STATUS WLS28-2 Multicolor LED Strip Light

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Electrical connection

WLS27 Multicolor LED Strip Light with EZ-STATUS

Amplifier for fiber optics. Dimensioned drawing

POC Type 4 GuardShield Standard, Remote Teach & Cascadable Safety Light Curtains

WLC60 Heavy Duty LED Light - PWM Dimmable

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Fibre Optic Modem ODW-622

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

W100L: Laser Sensor in Mini- Format

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Electrical connection

Fibre Optic Modem ODW-611

SPACESCAN SERIES SS 02

EZ-LIGHT K90FDL Daylight Visible

Absolute Encoders Multiturn

Dissolved Oxygen Transmitter

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

2-12. General Principles 2-Opto-electronics Safety Switches Operator. Interface. Logic Power

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Dissolved Oxygen Transmitter

True Color Sensor with Analog and Digital Outputs

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Quick-disconnect cables. Adjustable mounting brackets

V 180 Series Photoelectric Switches

EZ-LIGHT K30L Series With Independent Push Button Contact

MINI-BEAM Expert Series Installation Guide Microprocessor-based TEACH mode photoelectric sensors¹

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Light Curtain Type LA

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Safety Light Curtains

02/11/2015

DF-G3 Long Range Expert Dual Display Fiber Amplifier

DF-G3 Long Range Expert Dual Display Fiber Amplifier Instruction Manual

DATA SHEET Panorama Rudder Indicator, TRI-2

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

ODW-621. RS-232 Point-to-point applications

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Lt DELTA USA, Inc

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

Operating Instructions

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Wall-/Pipe-Mount Level Indicator

Quick-disconnect cables. Adjustable mounting brackets

LD OEM/LD PDS/LD PeCo

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

Safety Light Curtain Orion1 Extended

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

Photoelectric sensor Photoelectric Sensor for Plastic Fibers DF-G1-KS-Q7

LONWORKS Fibre Optic Router

Standard RS232 RS ma

Fibre optic router for TP/FT-10 LRW-112PP

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

1900/25 Vibration Monitor

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

ImproX (TRT) Twin Remote Terminal

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Absolute encoders multiturn

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

DF-G2 High Speed Expert Dual Display Small Object Counter. Instruction Manual

I/A Series Hardware Fiber Optic LAN Converter

DF-G2 High Speed Expert Dual Display Fiber Amplifier with IO Link

Quick-disconnect cables. Adjustable mounting brackets

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Smart-Encoder : Optical Incremental

Electrical connection

LONWORKS Fibre Optic Converter

LUT Luminescence scanners: Seeing what no-one else can

EZ-SCREEN LS. Safety Light Screen

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Transcription:

Mechanical Electrical Optical Cat No. Strobing Models COS Models Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors Polarized Retroreflective Retroreflective Standard Diffuse Fiber Optic Transmitted Beam Infrared Glass Visible Red Plastic ClearSight Receiver Source 5-pin micro QD GNU- 900- QD GNU- 9000- QD GNP- 9000- QD GNF- 9000- QD GNF- 900- QD GNC- 900- QD GNR- 900- QD GNL- 90- QD 5-pin mini QD GNU- 900- QD GNU- 9000- QD GNP- 9000- QD GNF- 9000- QD GNF- 900- QD GNC- 900- QD GNR- 900- QD GNL- 90- QD m cable GNU-900 GNU-9000 GNP-9000 GNF- 9000 GNF-900 GNC-900 GNR- 9000 GNL- 90 5-pin micro QD GNU- 90- QD GNU- 900- QD GNP- 900- QD GNF- 900- QD GNF- 90- QD GNC- 90- QD GNR- 900- QD GNL- 90- QD 5-pin mini QD GNU- 90- QD GNU- 900- QD GNP- 900- QD GNF-900- QD GNF- 90- QD GNC- 90- QD GNR- 900- QD GNL-90-QD m cable GNU-90 GNU-900 GNP-900 GNF- 900 GNF-90 GNC-90 GNR- 900 GNL- 90 Max. Sensing Distance.8m (6ft) 9m (30ft).5m (5ft).m (ft) 5m (500ft) 5m (500ft) Field ofview.5_.5_ 3.5_ Varies w/fo cable Varies w/fo cable 3.5_.5_ Not applicable 3 Transmitting LED Visible Red 660nm Infrared 880nm Visible Red 660nm Not applicable Infrared 880nm Sensitivity Adjustment Yes Yes No 5 Supply Voltage --5VDC 6 Current Consumption 70mA maximim 7 Power Consumption W maximum 8 Response Time 3.5ms 6.5ms Not applicable 9 Protection Output: Short circuit protected, Power: Reverse polarity, False pulse (300ms power ON delay) 0 Housing Material Valox Lens Material Acrylic Not applicable Acrylic Power: Reverse polarity Indicators SeeTable Green: Power 3 Operating Temperature --5_ to +70_C(--3_ to +58_F) Environmental DeviceNet Operating Environment NEMA X, 6P, IP67; 870kPa (00psi) washdown 5 Vibration 0--55Hz, mm amplitude, meets or exceeds IEC 97--5-- 6 Shock 30G, meets or exceeds IEC 97--5-- 7 Relative Humidity 95% 8 Approvals UL, CSA, CE for all applicable directives, ODVA compliant 9 Network Interface DeviceNet 0 Protocol Change-of-State (COS) or Strobing by model Operating Mode Selectable Light/Dark Operate Communication Rate Selectable 5kb, 50kb, 500kb 3 Supported Node Address Selectable 0 to 63 Margin Diagnostic Type Strobing models (static), COS models (dynamic)

Typical Response Curves Retroreflective 00 80 0 0 8 m (.5I) 76mm (3I) Polarized Retroreflective 00 80 0 0 8 76mm (3 ) m (.5 ) ClearSight Clear Object Detector 0 5 3 Standard Diffuse 00 80 0 0 8 White Paper, 6mm x 79.mm (8.5 x ) 6mm (0.65I) 6mm (0.65 ) 5mm (I) (i) (i).5m (5i) (0i) 5m (50i) 5mm ( ) 50mm (6 ) ( ).5m (5 ) (0 ) 6m (0 ) 5m (50 ) 5mm (I) 50mm (0I).5m (00I) 5mm ( ) 50mm (6 ) ( ) ( ).5m (5 ) (0 ) 6m (0 ) Transmitted Beam, 6m (00ft), 5m (500ft) Light Source Visible Red Fiber Optic Standard Diffuse Visible Red Fiber Optic Transmitted Beam Visible Red Fiber Optic Retroreflective 0000 00 000 0 00 0 ( ).8m (5 ) (0 ) Infrared Fiber Optic Standard Diffuse 5m (50 ) 30m (00 ) 50m (500 ) 0000 00 000 0 00 0.5mm (0.I).m (0.09I).0mm (0.0I) Plastic Fiber.0mm (0.0I) Plastic Fiber-Coiled 5.mm (.0I) 0.5mm (0.0I) Plastic Fiber 0.5mm (0.0IPlastic Fiber Bundle 76.mm (3.0I) Infrared Fiber Optic Transmitted Beam (I) (i) White Paper 6mm X 79.mm (8.5 x ) 0000 00 000 0 00 0.5mm (0.I).5mm (0.6I) 5mm (.0I).0mm (0.0I) Plastic Fiber.0mm (0.0I) Plastic Fiber-Coiled 76mm (3.0I) Infrared Fiber Optic Retroreflective 0.5mm (0.0I) Plastic Fiber 0.5mm (0.06I) Plastic Fiber-Coiled (I) (i) 0000 00 000 0 00 0.5mm (0.I) 0.0 (0.5mm) Plastic Fiber Coiled 5.mm (.0I) 0.5mm (0.0I) Plastic Fiber 76.mm (3.0I) (I).m (0.09I) (i) With 76mm (3 ).0mm (0.0I) Plastic Fiber Coiled.0mm (0.0I) Plastic Fiber.5m (5i) 0000 00 000 White Paper 6mm x 79.mm (8.5 x ) 0000 00 000 3.8mm (5 ) 0000 00 000 With 78mm (3 ) 0 00 0 3.8mm (0.5 ).5mm (0.06 ) 0.69m (0.07 ) 0 00 0.5mm (0.060 )GlassFiber 0.69mm (0.07 ) 0 00 0 0.07 (0.69mm) 0.5 (3.8mm) 0.060 (.5mm).5mm (0.I) 5mm (.0I) 50mm (6.0I) (I) (i).5mm (0.I) 5mm (.0I) 50mm (6.0I) (I) (i).5mm (0.I) 5mm (.0I) 50mm (6.0I) (I) (i).5m (5i)

Dimensions mm (inches) All Versions Except Fiber Optic Fiber Optic 7.93 (.95) Ref 55.6 (.9) 03.63 (.08) Max. Travel 3.75 (.5) 7.75 (.88) Cable Version 5. (0.60) 7.93 (.95) Ref 55.6 (.9) 3.33 (0.5) 03.63 (.08) Max. Travel 7.75 (.88) Cable Version 5. (0.60) 5. (0.0) X 8.3 (0.3) Slot, Plcs Cable Length m (6.5 ) 6.5 (0.55/0.5) Dia. M30 X.5 External Thread / NPSM Internal Thread 5.87 (0.65) 5.6 (0.5) 5. (0.0) x 8.3 (0.3) Slot, Places M30 X.5 External Thread / NPSM Internal Thread Cable Length m (6.5ft) 6.7/6. (0.5/0.) Dia. 5.87 (0.6) 5.6 (0.).0 (.57).9 (.65).0 (.57).9 (.65) Connector Version Micro Style Mini Style Thread Size Micro Style AC /--0 UNF Keyways DC M x Keyway 3.97 (0.550) 7.78 (0.700) Mini Style 7/8--6 UN Keyway Accessories Description Catalog Number Description Catalog Number Description Catalog Number m (6.5ft) mini QD Cordset 85R- PN5- C RS--3 PC Interface Module 770- KFD, 3I Diameter 9-39 m (6.5ft)mini QD Patchcord 85R- PN5- M5 RS Networx Software 9357DNETL3,.5I Diameter 9-7 m (6.5ft) micro QD Cordset 85R- PR5- C PCMCIA DeviceNet Interface Card 78- PCD Other DeviceNet Products See Publication DN.5 m (6.5ft) micro QD Patchcord, 90_ 85R- PR5- F5 DeviceNet Hand-Held Configurator 707- DNC 3

User Interface Using an instrument screwdriver, open the top cover of the sensor to gain access to the user interface panel. This panel contains a pushbutton and LED indicators for configuring and viewing the sensor s operation and status. A more complete description of each item is described below. Timing Sensors Top View Detail Mounting the Sensor Securely mount the sensor on a firm, stable, surface or support using one of the many mounting brackets available from Rockwell Automation/Allen-Bradley. The sensor is supplied with hardware kit #9--30 which contains a plastic mounting nut, lock washer, M5 x 0.8 x 53 screws and nuts. Excessive vibration or shifting may cause intermittent operation of the sensor. Sensitivity Adjustment Programming Pushbutton M5x0.8x53 Combination Screws and Nuts (Supplied) Yellow -- Output Green -- Margin Red/Green Status Pushbutton A single momentary pushbutton is used to configure the sensor (strobing models only). Refer to the configuration section in this document for complete instructions on using this feature. LED Indicators Three LED indicators are provided to indicate a variety of conditions making it easy for installation and troubleshooting. The function of each is described in the table below. The LEDs also work together as indicated on page 5 when used in the configuration mode. Table. LED Function Label Color State Status Output Yellow ON Target detected Margin Green OFF Margin <.5 ON Margin >.5 Status Red/Green OFF Sensor not powered Green ON Steady Green Flashing Red Flashing Red ON Steady Sensor active and allocated by master Sensor active but not allocated by master Minor correctable fault (baud rate) Major fault (possible duplicate address) NOTE: LED indicators are used during the configuration operation of the sensor. Refer to the configuration section for complete instructions on using this feature. Hardware Kit (Supplied) Wiring the Sensor Models of the Series 9000 DeviceNet are available in one of three different connection types as identified in the following table. Rockwell Automation/Allen-Bradley recommends the use of the 85R Series of cordsets and patchcords on the quick-disconnect models. All external wiring should conform to the National Electric Code and all applicable local codes. Designation Lead Color Pin Assignment m Cable 5-Pin Micro QD 5-Pin Mini QD 5 5 3 3 V+ Red V-- Black 3 3 CAN + White CAN -- Blue 5 5 Drain Bare

Sensor Configuration Once installed and aligned the sensor must be configured (programmed) to operate properly. Using the pushbutton under the sensor s cover or a Configuration Tool such as RS Networx the user must set the sensor s address, baud rate and select Light or Dark operating mode. Note that COS models can only be configured over the network. The following instructions refer to local programming. For programming with a Configuration Tool, refer to the instructions provided with the tool. Programmingisatwostepprocess.. First a Category is selected using the pushbutton. The RED STATUS Indicator: a. Confirms Category selection by flashing the same number of times the pushbutton was pressed to select a category. (/ second flashes) or b. Flashes once for one full second to indicate an invalid input.. Then a setting is input using the pushbutton. The GREEN STATUS Indicator: a. Confirms the setting by flashing the same number of times the pushbutton was pressed to input the setting. or b. The RED STATUS Indicator flashes once for one full second to indicate an invalid input. Enter Programming Mode Press the pushbutton for 3 seconds and release it. The RED and GREEN Network STATUS Indicators each flash twice, alternately, to confirm entry to PROGRAMMING MODE. Return to Run Mode The sensor may be returned to RUN MODE in either of two ways. The user can return the sensor to RUN MODE from PROGRAMMING MODE at any time by pressing the pushbutton for 3 seconds and releasing it. The RED and GREEN Network STATUS Indicators each flash twice, alternately, to confirm return to RUN MODE mode. Or the sensor will automatically return to RUN MODE from PROGRAMMING MODE whenever the pushbutton remains unpressed for 5 seconds! Setting Sensor Address: Valid addresses: 00 thru 63 (factory default: 63) Category. MSD Press the pushbutton one time, quickly. Press the pushbutton once quickly to set the MSD to, twice to set it to, etc. Press the pushbutton ten times to set the MSD to 0. The GREEN STATUS Indicator flashes to confirm the setting; once for a setting of, twice for a setting of, etc. Category. LSD Press the pushbutton two times, quickly. Press the pushbutton once quickly to set the LSD to, twice to set it to, etc. Press the pushbutton ten times to set the LSD to 0. The GREEN STATUS Indicator flashes to confirm the setting; once for a setting of, twice for a setting of, etc. Category 3. Operating Mode (default: Light Operate) Press the pushbutton 3 times, quickly. Light Operate: Press the pushbutton once, quickly. Dark Operate: Press the pushbutton twice, quickly. The GREEN STATUS Indicator flashes to confirm the setting. Category. Baud Rate (default: 5 kb) Press the pushbutton times, quickly. 5kb: Press the pushbutton once, quickly. 50kb: Press the pushbutton twice, quickly. 500kb: Press the pushbutton 3 times, quickly. Category 5. Reset to Factory Default Press the pushbutton 5 times, quickly. Press the pushbutton once. The GREEN STATUS Indicator flashes to confirm that all settings have been reset to factory values. 5

Table. Configuration Parameters Parameter Type Options Default Operate Mode R,W Light or dark operate Lightoperate SensorOutput R Bit 0: 0=output OFF, =output ON Diagnostic R Bit : 0=OK, =alarm Communication Rate R,W 5, 50, 300kB 5kb Node Address R,W 0to63 63 Diagnostic Operation The Series 9000 DeviceNet sensors provide a diagnostic output bit to indicate an unstable sensing condition. This condition can be caused by a dirty or contaminated lens or by sensor misalignment. Strobing models of the sensor will output immediately upon detection of a margin value between and.5. This method, called static diagnostic, is ideal for web sensing applications where an immediate indication is required. The diagnostic bit of COS models will not output until a complete low margin transition occurs. Called dynamic diagnostics, this method is best suited for applications where targets are constantly moving into and out of the sensor field of view, i.e., conveyor application. Data Byte Bit 0 Bit Output Diagnostic 0 OFF OK ON ALARM Transmitted Beam Mode Visually align the emitter and receiver units (emitter and receiver fibers) until the Output LED on the top of the control lights up (with Light Operate mode) or goes out (with Dark Operate mode). To be certain that the beam is centered, it is required to sweep the emitter or receiver in the horizontal and vertical plane and determine at what position the output indicator goes on and then goes off. Set the sensor (or fiber optics) halfway between both positions. The Margin LED should also be on when the beam is unbroken. Retroreflective/Polarized Retroreflective Mode Visually align the sensor (or fiber optic cable) on the reflector until the Output LED on the top of the control lights up (with Light Operate mode) or goes out (with Dark Operate mode). Also verify that the Margin LED is on. To be certain that the beam is centered, it is required to sweep the sensor in the horizontal and vertical plane and determine at what position the output indicator goes on and then goes off. Set the sensor (or fiber optics) halfway between both positions. Break the beam with the object to be detected and check if the output indicator turns on. When this does not happen turn down the sensitivity adjustment until it does. Restore the light beam by removing the object and check if the output indicator turns off again and that the Margin LED comes on. If this does not happen, increase the size of the reflector or decrease the distance between the reflector and the sensor. Diffuse Mode Visually align the sensor (or fiber optic cable) on the object until the Output LED on the top of the control lights up (with Light Operate mode) or goes out (Dark Operate mode). To be certain that the beam is centered, it is required to sweep the sensor in the horizontal and vertical plane and determine at what position the output indicator goes on and then goes off. Set the sensor (or fiber optics) halfway between both positions. Remove the object in front of the sensor and eliminate any background signals by turning down the sensitivity adjustment, if such background signals exist. Replace the object and verify that the output LED goes on and that the Margin LED is on. PHOTOSWITCH R is a registered trademark of Rockwell Automation/Allen-Bradley. 6 Publication 7505-38 -0(A) May 00 Printed in USA