Agilent 53310A Modulation Domain Analyzer Data Sheet

Similar documents
Digital Delay/Pulse Generator

Digital Delay/Pulse Generator

Digital Delay/Pulse Generator

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Agilent 5345A Universal Counter, 500 MHz

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

Full-featured CW Microwave Counters for Field, Factory or Lab

Agilent 87075C Multiport Test Set Product Overview

Microwave Counter, Power Meter and DVM in One Portable Package


Agilent 8560 E-Series Spectrum Analyzers

Broadcast Television Measurements

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent 81600B Tunable Laser Source Family

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Frequency. Range. HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz. Standard 10 MHz timebase: f10 ppm

PM 6680B / PM 6681 / PM 6681R

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

Synthesized Clock Generator

Agilent MSO and CEBus PL Communications Testing Application Note 1352

Agilent Technologies 54522A

R&S RT-Zxx High-Bandwidth Probes Specifications

Digital Storage Oscilloscopes 2550 Series

Agilent E5100A Network Analyzer

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Agilent I 2 C Debugging

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

PicoScope 6407 Digitizer

Sources of Error in Time Interval Measurements

GFT Channel Digital Delay Generator

Advanced Test Equipment Rentals ATEC (2832)

2 MHz Lock-In Amplifier

Agilent 11713A Attenuator/Switch Driver

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

Data Pattern Generator

Agilent E4430B 1 GHz, E4431B 2 GHz, E4432B 3 GHz, E4433B 4 GHz Measuring Bit Error Rate Using the ESG-D Series RF Signal Generators, Option UN7

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

PicoScope 6407 Digitizer

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Advanced Test Equipment Rentals ATEC (2832)

Debugging Digital Cameras: Detecting Redundant Pixels

Agilent PN Time-Capture Capabilities of the Agilent Series Vector Signal Analyzers Product Note

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

We bring quality to light. SNT 10 DC Power Supply

SDS1000C Specifications

Microwave/Counter/Analyzer & Integrated Power Meter

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

Portable Performance for Debug and Validation

SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

ScopeMeter 190 Series Specifications

4 MHz Lock-In Amplifier

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

GFT Channel Slave Generator

R&S ZVA110 Vector Network Analyzer Specifications

R&S SMF100A Microwave Signal Generator Specifications

The Measurement Tools and What They Do

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

TDS 520B, TDS 540B, TDS 620B, TDS 644B, TDS 680B, TDS 684B, TDS 724A, TDS 744A, & TDS 784A

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors

R&S RT-Zxx High-Voltage and Current Probes Specifications

Microwave/Counter/Analyzer with Integrated Power Meter MCA3000 Series Datasheet

R&S FPC1000 Spectrum Analyzer Specifications

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

2 MHz Lock-In Amplifier

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

R&S ZNBT Vector Network Analyzer Specifications

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Fluke PM6690. Frequency Counter/Timer/Analyzer

Expect to Make Waves.

Data Pattern Generator

CBF500 High resolution Streak camera

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope

Agilent PSA Series Spectrum Analyzers Data Sheet

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

R&S FSMR Measuring Receiver Specifications

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

Data Pattern Generator DG2020A Data Sheet

FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD

TSG 90 PATHFINDER NTSC Signal Generator

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

GFT channel Time Interval Meter

Specifications. Reference Documentation. Performance Conditions

16 bit. A digital oscilloscope for the analog world HIGH-RESOLUTION USB OSCILLOSCOPE

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

R-1580A Microwave Downconverter. Product Brochure

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

Transcription:

View at www.testquipmentepot.com gilent 53310 Modulation omain nalyzer ata Sheet Test quipment epot 800.517.8431 99 Washington Street Melrose, M 02176 X 781.665.0780 Testquipmentepot.com

Product escription This section offers a brief description of the gilent Technologies 53310 Modulation omain nalyzer. It follows the menu structure of the product and describes its operation. or specifications, see the Product Specifications and haracteristics section. unction requency hannel:,, or (Optional) Time Interval Measurement: +TI or ±TI hannel: and (Separate) or only (ommon) Start: or Stop: or Input hannels and Voltage Threshold Range: Manual: +10 V to 10 V, settable in 2.5 mv steps uto: ind 50% Threshold oupling: ac or dc Impedance: 1 MΩ or 50 Ω Hysteresis: Min to Max, settable in ten steps Vertical/Histogram isplay Range isplay measurement range is settable as enter and Span, or Minimum and Maximum. or frequency measurements, the maximum display value can be selected no larger than eight times the minimum display value. Timebase Main Timebase Range: Panorama Off: /div to 1 s/div Panorama On: 1 to 20 times the window timebase setting (standard); 1 to 80 times the window timebase (Option 001) Window Timebase Range: /div to 1 s/div Position: djustable throughout the panorama Trigger isplay Position: Left, enter, or Right elay: djustable hannel (Optional) Voltage Threshold: 0 volts oupling: ac Impedance: 50 Ω Hysteresis: Minimum xternal rm Voltage Threshold: 0V, TTL (1.5 Volts), or L ( 1.3 Volts) ual timebases allow you to capture all the information you want, as shown in the panorama, while analyzing measurement details in the window. 2

Trigger Mode: uto or Triggered Triggered: dge Trigger Slope: or of xternal Value Trigger Source: requency or Time Interval measurements, depending on measurement function Range requency: 80% of minimum display value to 120% of maximum display value Time Interval: full measurement range Slope: or H Reject: On or Off isplay Type: vs Time or Histogram rame type: rame, xes, Grid, or Off vs Time cquisition Mode: Real Time or Repetitive Real Time Persistence: Single or Infinite Repetitive veraging: On or Off Histogram Probability Scale (percent): Log or Linear Probability Scaling: uto or Manual ccumulate: On or Off Markers Horizontal and vertical markers are available in vs Time and Histogram displays. Markers can be used in conjuction with automated analysis. They may also be used to delimit a portion of the measurement data for detailed analysis. Sampling Modes: uto, dge, or Time uto: onstant event sampling based on Timebase settings dge: hannel or : very 1 to 256 events xternal: very event Time: 400 ns 1 second Utility GPI/Print setup Mode: ddressed or Talk Only licker: On or Off Screen Saver: On or Off alibration and iagnostic routines utoscale Setup parameters are automatically determined to display the dynamics of the input signal. Measurement function and input conditioning should be selected prior to pressing utoscale. utomated nalysis uilt-in analysis functions include: Minimum, Maximum, Peak to Peak, Mean, 1/Mean, Standard eviation, (Modulation) Rate, 1/Rate, and Probability. Save/Recall Ten measurement setups can be stored and recalled. Histogram Histogram Type: Histogram from vs Time or ast Histogram ccumulate: On or Off ast Histogram: cquire Start: uto, or xternal Start on or edge Number of Measurements: 1 to 16 million per acquisition, >10 14 can be accumulated. 3

Product Specifications and haracteristics oth warranted specifications and operating characteristics of the gilent 53310 are discussed in this section. To distinguish warranted specifications from operating characteristics, specifications are highlighted throughout in italics. requency Measurements Range hannel : 10 Hz to 200 MHz hannel : 10 Hz to 100 MHz hannel : 50 MHz to 2.5 GHz Maximum Measurement Rate ast Histogram: 1.5 MHz Other Modes: 1 MHz Resolution Maximum available measurement resolution or display resolution, whichever is greater requency Resolution (rms) 100 khz 10 khz 1 khz 10 Hz 1 Hz 100 mhz 10 mhz 1 mhz 100 µhz 10 µhz Graph 1. Maximum available frequency resolution for hannels and. Larger timebase settings and averaging will reduce the effects of random noise and improve resolution. Legend for Graphs 1 and 2 1 khz 10 khz 100 khz 1 MHz 10 MHz 100 MHz 1 GHz Measured requency (1 V rms sinewave, 100 µv rms noise) G Maximum vailable Measurement Resolution (uto Sampling): See Graph 1 for hannels and See Graph 2 for Option 030 hannel Note: Option 031 High Resolution 2.5 GHz hannel offers superior measurement resolution. Refer to ynamic requency and Jitter nalysis at the Touch of a utton, gilent 53310 brochure. G Timebase Setting (Interval at enter: uto) 20 µs/iv 200 µs/iv 2 ms/iv 20 ms/iv 200 ms/iv Interval at enter Setting (Interval at enter: Manual) 10 µs 100 µs 1 ms 10 ms 100 ms 0.5 s isplay Resolution: vs Time, or Histogram of vs Time Window Off: isplay Span/256 Window On: isplay Span/224 ast Histogram: isplay Span/450 ccuracy: ±[Resolution + (requency x Reference rror) ] Refer to Graph 3. 4 requency Resolution (rms) 1 MHz 100 khz 10 khz 1 khz 10 Hz 1 Hz 100 mhz 10 mhz 1 mhz 100 µhz 10 MHz 100 MHz 2.5 GHz 50 MHz 1 GHz 10 GHz Measured requency (0 dm sinewave, 100 µv rms noise) Graph 2. Maximum available frequency resolution for Option 030 2.5 GHz hannel. Larger timebase settings and averaging will reduce the effects of random noise and improve resolution. G

Time Interval Measurements + Time Interval Range: +20 ns to +1 second Maximum Measurement Rate: ast Histogram: 2.5 MHz Other Modes: 1.25 MHz ± Time Interval Range: 0.5 s to +0.5 second Maximum Measurement Rate: ast Histogram: 2.0 MHz Other Modes: 1.25 MHz Resolution Maximum available measurement resolution or display resolution, whichever is greater Maximum vailable Measurement Resolution: ( ) + 2 2 200 ps rms * Threshold Trigger rrors Notes 1) Threshold trigger errors are usually negligible for input slew rates >5V/µs. 2) Through averaging, maximum available measurement resolution can be significantly improved. isplay Resolution: vs Time, or Histogram of vs Time Panorama Off: isplay Span/256 Panorama On: isplay Span/224 ast Histogram: isplay Span/450 ccuracy: ± Resolution ±(Time Interval x Reference rror) ±Start Threshold Level Timing rror ±Stop Threshold Level Timing rror ±1 ns Systematic rror * 125 ps rms typical Refer to Graph 4. Refer to Graph 5. Refer to Graph 6. requency rror 100 khz 10 khz 1 khz 10 Hz 1 Hz 100 mhz 10 mhz 1 mhz 100 µhz 10 µhz 1 µhz 1 khz 10 khz 100 khz 1 MHz 10 MHz 100 MHz 10 GHz 1 GHz Measured requency Graph 3. requency Reference rror. rystal aging will affect your frequency accuracy. Legend for Graphs 3 and 4 Time Since Last alibration Time Interval rror 1 Month 1 Year 10 Years 100 µs 10 µs 100 ns 10 ns 1 ns 100 ps 10 ps 1 ps Standard Reference Option 010 Reference 10 µs 100 µs 1 ms 10 ms 100 ms 1 s Measured Time Interval Graph 4. Time Interval Reference rror. rystal aging will affect your time interval accuracy. 5

Time xis in vs Time Resolution Main Timebase Setting/45, with panorama off Window Timebase Setting/45, with panorama on ccuracy: Resolution Note: Time aliasing can occur when time between measurements exceeds 360 divisions. Inputs hannel and Sensitivity (minimum hysteresis): 20 mv rms sine wave to 100 MHz (25 mv rms sine wave for req from 100 MHz to 200 MHz) Minimum Pulse Width: 5 ns at 60 mv p-p (2.5 ns at 75 mv p-p for requency measurements above 50 MHz) Input mplifier Noise: 600 µv rms Threshold rift: ±3 mv after warm-up at 25 Voltage Threshold ccuracy: ±(25 mv + 1% of Threshold Value) Maximum Hysteresis: Increases the minimum input signal amplitude required by a factor of three, providing additional noise immunity. Impedance: 50 Ω or 1 MΩ (500 kω in common) ac oupling: cutoff frequency apacitance (1 MΩ): <20 p (<30 p in common) ynamic Range (ac): 60 mv p-p to 5 V p-p Signal Operating Range (dc): 1 MΩ: ±10 volts 50 Ω: ±5 volts amage Level: 1 MΩ: 40 V rms for <5 khz, 5 V rms for >5 khz 50 Ω: 5 V rms RMS Threshold Trigger rror (per edge) 100 ns 10 ns 1 ns 100 ps 10 ps 1 ps 10 µv 0.1 V/µs Input 1 V/µs Input 10 V/µs Input 0.1 V/ns Input 1 V/ns Input 100 µv 1 mv 10 mv 100 mv 1 V Input Signal Noise (rms) Graph 5. Noise on the input signal will add error to time-interval measurements. rror is associated with both start and stop edges. Timing rror (per edge) 100 ns 10 ns 1 ns 100 ps 10 ps 1 ps 100 mv/µs 1 V/µs 10 mv/ns 100 mv/ns 1 V/ns 10 V/ns Input Signal Slew Rate Graph 6. Voltage Threshold Level Timing rror varies with input slew rate. rror is associated with both start and stop edges. 6

hannel (Option 030) Sensitivity: 25 dm to 1.5 GHz, 20 dm from >1.5 GHz to 2.0 GHz, 15 dm from >2.0 GHz to 2.5 GHz Maximum Input Level: +7 dm amage Level: +15 dm Note: or specifications on the Option 031 High Resolution 2.5 GHz hannel, refer to ynamic requency and Jitter nalysis at the Touch of a utton, 53310 brochure. xternal rm Impedance: 1 MΩ elay: <10 ns Note: Sensitivity, Minimum Pulse Width, Signal Operating Range, and amage Level of the xternal input are the same as that of hannel. requency Reference Standard rystal Temperature Stability: <8 x 10 6, referenced to 25 Short Term Stability: <4 x 10 9 for 1 second average ging Rate: <3 x 10 7 /month Option 010 High Stability Oven Reference Temperature Stability: <7 x 10 9, referenced to 25 Short Term Stability: <4 x 10 11 for 1 second average ging Rate: <5 x 10 10 /day, <1 x 10 7 /year Warmup: Within 5 x 10 9 of final value*, 10 minutes after turn-on** When: 1) 53310 is operated in a 25 environment 2) Oscillator off-time** was less than 24 hours 3) Oscillator aging rate was <5 x 10 10 per day prior to turn-off** Rear Panel onnectors GPI ontrols: The gilent 53310 provides full programmability. ll instrument settings and operating modes, except specific self-test routines, may be remotely programmed via GPI (I Std 488.1-1987). The programming codes and formats comply with I Standard odes, ormats, Protocols, and ommon ommands (I Std 488.2-1987), and Standard ommands for Programmable Instruments (SPI) Standard, Version 1990.0. * inal value is defined as oscillator frequency 24 hours after turn-on. ** Turn-off, turn-on, and off-time apply to periods when power is disconnected from the 53310 rear panel. ata cquisition and Transfer Rate: 450 point data record can be acquired and transferred to a computer at a rate ~17 times per second, as tested with an HP 9000, Series 300 controller. or this test, a 1-MHz carrier was applied to the analyzer with a timebase setting of 40 µs/division. ata Transfer Rates: ~175 kyte/s Interface apabilities: SH1, H1, T5, T0, L4, L0, SR1, RL1, PP0, 1, T1, 0, 2 Test Limit Output The Test Limit Output will go high when measurements fall outside the display range of the ast Histogram. In vs Time mode, it will indicate each time the Value Trigger condition is met following the pre-trigger delay. Operating Range: Low <0.6 V and High >1.5 V into 50 Ω requency Standard Input requency: 5 MHz or 10 MHz Operating Range: 1 V p-p to 5 V p-p, into 1 kω amage Level: 10 V rms requency Standard Output requency: 10 MHz, or the xternal Reference if the requency Standard Input is used. Operating Range (ac coupled): 50 Ω: >1 V p-p square wave 1 MΩ: >2 V p-p square wave Power Requirements Voltage: 115/230 Vac ( 25% to +15%) requency: 48 to 66 Hz Maximum Power: 300 V General Operating Temperature: 0 to 55 Weight: 10 kg net, 18 kg shipping imensions: 425 mm W x 194 mm H x 363 mm (440 mm with handle extended) Warranty The gilent 53310 Modulation omain nalyzer comes with a one-year return-for-service warranty. 7

Specifications Option 031 oth warranted specifications and operating characteristics of the gilent 53310 are discussed in this section. To distinguish warranted specifications from operating characteristics, specifications are highlighted throughout in italics. Input onditions Range: 50 MHz to 2.5 GHz Sensitivity: 13 dm 50 MHz to 200 MHz 17 dm 200 MHz to 2 GHz 12 dm 2 GHz to 2.5 GHz Maximum Input Level: +20 dm amage Level:+23 dm Impedance: 50 Ω oupling: ac R urst Width: 50 µs to W Maximum Measurement Rate ast Histogram: 1.5 MHz Other Modes: 1 MHz ast Sampling: 8 MHz (repetitive) xternal Local Oscillator Input Level: +6dm (±1d) Impedance: 50 Ω requency Range: 150 MHz to 2.5 GHz Resolution Maximum available measurement resolution or display resolution, whichever is greater Maximum vailable Measurement Resolution (uto Sampling): see Graph isplay Resolution: vs Time or Histogram of vs Time Window Off: isplay Span/256 Window On: isplay Span/224 ast Histogram: isplay Span/450 ccuracy: ±[Resolution + (requency x Reference rror*)] Maximum vailable requency Resolution requency Resolution (rms) Internal LO 100 khz 10 khz 1 khz 10 Hz 1 Hz 100 mhz 10 mhz 1 G 1 mhz 200 MHz 100 MHz 2.5 GHz 1 GHz 10 GHz Timebase Setting Interval @ center: uto Measured requency (0 dm sine wave, 100 µv rms noise) Graph. Maximum available frequency resolution for Option 031 hannel. Larger timebase setting and averaging will reduce the effects of random noise and improve resolution. Please refer to Graph 2 on page 4 for resolution over the 50 MHz 200 MHz band. Interval @ enter Setting (Interval @ enter: Manual) 1 125 ns 20 µs/iv G 200 µs/iv 2 ms/iv 20 ms/iv 200 ms/iv 10 µs 100 µs 1 ms 10 ms 100 ms 0.5 s requency Resolution (xt. LO) 7 khz 1 khz 20 Hz 5 Hz 2 Hz 50 mhz 5 mhz 2 mhz Typical resolution over the 200 MHz to 2.5 GHz range using an gilent 8663 Synthesizer as an external LO ast Sampling mode R nvelope Trigger Level: djustable in 100 steps (e.g., 25 dm to 0 dm @ 1 GHz) Output: 0 to 0.4 volt into 50 Ω or TTL level into high impedance 8

Specifications Option 305 Minimum System Requirements gilent 53310: Works with any option, but ast (repetitive) Sample Rate is not supported. IM-compatible P: 386-based with coprocessor 4 Mbyte RM 2 Mbyte hard disk space MS-OS 5.0 Windows 3.1 I 488.2 Interface: HP 82335 or HP 82341 National Instruments T-GPI or T-GPI/TNT with NI-488.2 version 2.1.1 drivers for Windows Performance haracteristics Typical Performance (1 GHz arrier) Off. req I Noise loor <10 Hz 20 Hz 180 d 200 Hz 170 d 1 khz 2 khz 160 d 10 khz 20 khz 150 d 100 khz 200 khz 140 d 500 khz 1 MHz 130 d MS-OS and Windows are U.S. registered trademarks of Microsoft orporation. 9

gilent Technologies Test and Measurement Support, Services, and ssistance gilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right gilent products for your applications and apply them successfully. very instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie gilent s overall support policy: Our Promise and Your dvantage. Our Promise Our Promise means your gilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use gilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your dvantage Your dvantage means that gilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, outof-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional services. xperienced gilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your gilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. y internet, phone, or fax, get assistance with all your test and measurement needs. Online ssistance www.agilent.com/find/assist Phone or ax United States: (tel) 1 800 452 4844 anada: (tel) 1 877 894 4414 (fax) (905) 206 4120 urope: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Latin merica: (tel) (305) 269 7500 (fax) (305) 269 7599 ustralia: (tel) 1 800 629 485 (fax) (61 3) 9272 0749 New Zealand: (tel) 0 800 738 378 (fax) (64 4) 495 8950 sia Pacific: (tel) (852) 3197 7777 (fax) (852) 2506 9284 Product specifications and descriptions in this document subject to change without notice. opyright 1998, 2000 gilent Technologies Printed in U.S.. 8/00 5966-4092 Test quipment epot 800.517.8431 99 Washington Street Melrose, M 02176 X 781.665.0780 Testquipmentepot.com