User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

Similar documents
User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

OPTICAL DISTRIBUTION STATION -

XCOM1002JE (8602JE) Optical Receiver Manual

DVO700 P FIBRE OPTIC TRANSMITTER

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Compact Mini Amplifiers Series and Series

OTX Optical Transmitter. Operation Instructions

OTLT / OTLR 3000 Manual. L-Band Fiber Optic Link MHz INSTRUCTION MANUAL

L-BAND over Fiber Link TX/RX. User Manual. L-1Ch-L-Band-TX/RX

Description. Features MODEL ODN2P OPTICAL DISTRIBUTION NODE WITH TWO AMPLIFIED RF PORTS LIGHT LINK SERIES 2.

Fiber Optic. Foreword. Special Tips:

L-Band Fiber Optic Link

Prisma Optical Networks Ancillary Modules

SatellitePlus Model OLAT/OLAR. Advanced L-Band Series. 10-4,000 MHz OPERATING MANUAL

Multicom Optical Return Path Receiver MUL HRPR 4B

Compact EGC Fiber Deep Nodes A90100 and A90300

Product Operation Manual

Headend Optics Platform (CH3000)

QFMN. QFMN Fiber Mini Node Distribution Amplifier INSTALLATION & OPERATION MANUAL.

CPON-HFC. Customer Premises Optical Node for FTTH networks. About the Product

Optical Communications Mainframe - Laser Transmitter Module

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

User Manual ACE Rev (54) ACE Series. User Manual. Teleste Corporation. ACE3 Intelligent broadband amplifier

Litile34 OPERATION MANUAL

3M Fiber Optic Wall Mount Enclosure 8430 Series

Headend Optics Platform (CH3000)

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

HDO701 FIBRE OPTIC TRANSMITTER

Model GS Port Node 1 GHz with 65/86 MHz split

TV Radio Multimedia. Optical Nodes, 1218 MHz and 1006 MHz amplifiers, distribution and connection technology

OmniStar GX2 Headend Optics Platform

HFC. Enhance. QHFCN CATV Optical 2-way Mini Node Installation & Operation Guide

Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 Split

Typical applications:

QFN. QFN Fiber Node INSTALLATION & OPERATION MANUAL.

SHF Communication Technologies AG,

QCA9-33 Active Combiner

1.2 GHz GS7000 Node RF Split Upgrade Application Note

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

D3.1/CCAP Compliant HFC. Enhance. QHFCN CATV Optical 2-way Mini Node INSTALLATION & OPERATION MANUAL.

The Art of Engineering

AMERICAN NATIONAL STANDARD

clipping; yellow LED lights when limiting action occurs. Input Section Features

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

I N S T R U C T I O N D A T A

AMERICAN NATIONAL STANDARD

TRFM Series RF Amplifier Module

2015 OPTICAL TRANSMITTERS

Operating instructions

ENGINEERING COMMITTEE

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

One channel video link With duplex data and contact closure

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

Cisco GS7000 High-Output (GaN) 4-Way Segmentable Node with 85/102 MHz Split

Litile34 INSTALLATION MANUAL

Dish Diversity Switch

Four-way Return Optical Receiver Manual. Transmitter OP-OR124RJ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 1)

Hardware installation

Drop Passives: Splitters, Couplers and Power Inserters

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

Cisco 1.25 GHz Surge-Gap Passives

ViaLiteHD Fibre Optic Green OEM Link Modules

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages)

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

I/A Series Hardware Fiber Optic LAN Converter

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL.

COHERENCE ONE PREAMPLIFIER

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

CABLE TV on fiber. CABLE TV FIBERLINK Pass 100+ TV channels on 1 SingleMode fiber with no need for amps

INSTALLATION MANUAL. ST-CVTSD520-WSD-W Smoke Detector Covert Camera. v1.2 8/11/11 1

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

nm DFB Laser Module

INSTALLATION MANUAL. CTMS-516RKPS Rack Mount Satellite Multiswitch

PRODUCT OVERVIEW OPTICAL NODES

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

User Manual E Rev (20) E Series. User Manual. Teleste Corporation. E3 Compact amplifier

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

Amplifiers STARLINE 2000 Broadband Telecommunications Distribution Amplifier [BT*/*]

ACION 8000 Series. A8KFR1 1RU Forward Receiver

384A Adapter Installation Instructions

FiberLink 7142 Series

Fibre Optic Modem ODW-622

Table of Contents. Headend Optical Transport OmniStar Enhanced DFB Laser [AM-OMNI-ALM-*] file:////ncs-server-xp/temp/motorola CD 2001/frames.

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

OPTICAL POWER METER WITH SMART DETECTOR HEAD

THE ART OF ENGINEERING

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

Model GS7000 GainMaker Node Forward Local Injection Module Installation Instructions

Cisco GS MHz 4-Way Segmentable Node

HDO750 OPTICAL AMPLIFIER FAMILY

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2

SATCOM FIBER OPTIC PRODUCTS

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

User Manual HDO Rev (24) HDO Series. User Manual. Teleste Corporation. HDO773 C-band DWDM fibre transmitter

QDA4-44 RF Amp/Combiner

Transcription:

Broadband Cable Networks August 30, 2007 1(8) CXX Series User Manual Teleste Corporation CXE800 Fibre Optic Receiver

Broadband Cable Networks August 30, 2007 2(8) Introduction The CXE800 is a unidirectional, compact size fibre optic receiver. It is designed for areas where cost-efficiency and easy installations are prime concerns. The use of an integrated optical receiver eliminates time-consuming mounting of connectors and fibre splicing inside the housing. The optical receiver supports light wavelengths from 1290 nm to 1600 nm. Alignment of this product is easy. The Optical Level Control (OLC) as well as gain and slope adjustments use electrical controls that improve the reliability of this fibre optic receiver. Plug-in accessories are not needed in normal oneoutput operation. The distribution path, through the use of plug-in output modules, can be split easily in the field within matter of minutes, and a full range of taps/splitters are available. WEEE Notice This product complies with the relevant clauses of the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). The unit must be recycled or discarded according to applicable local and national regulations. European Conformity This equipment conforms to all applicable regulations and directives of European Union which concern it and has gone through relevant conformity assessment procedures.

Broadband Cable Networks August 30, 2007 3(8) Housing 8904047 1 2 3 4 Fig. 1. CXE800 Fibre Optic Receiver, 1) Optical fibre input port, 2) Ground, 3) RF output port2, 4) RF output port1 Installation The fibre optic receiver can be installed either into a street cabinet or to a sheltered outdoor environment. Note: Fibre adapter is not waterproof. The class of enclosure is IP43. The amplifier should be installed in a vertical position so that the external cable connectors are underneath. At least 100 mm of free space should be left above the amplifier to ensure sufficient cooling air circulation. The cover of the housing is closed by a single bolt. There are no hinges. Open cover is to be removed completely. When closing the cover use a PZD 2 screwdriver to tighten the bolt to a torque of 2.5...3.5 Nm. To ground the amplifier housing connect at least 4 mm 2 grounding wire (Cu) from a proper earth to the grounding point. Cable connections Underneath the CXE800 fibre receiver there is one optical fibre input and one RF output with F-female connector. Optionally a second RF output is available. All coaxial outputs have a standard PG11 thread and they accept any KDC type adapter or connector. Figure 2 illustrates the centre conductor. 8905010 Fig. 2. Centre conductor length

Broadband Cable Networks August 30, 2007 4(8) Powering The locally powered CXE800 fibre optic receiver is connected to the main voltage of 165 255 V AC via its own power cord. The power supply is double shielded and does not require separate grounding. However, the amplifier housing has to be grounded from the grounding point. The supply voltage fuse (T3.15 A / 250 V / TR5) is located on the upper right corner of the amplifier, beneath the shroud of the power supply unit. Fibre installation The CXE800 fibre optic receiver comes as standard with a bulkhead mounted SC/APC adapter. Fibre installation is a critical procedure and it should be done with carefulness. Incorrect handling of the fibre can result in damage and degraded performance. Warning: The SC/APC adapter is connected to the integrated fibre receiver through a short length of fibre on the rear side of the bulkhead. To avoid damage to the fibre, take care not to rotate the adapter when installing or removing the fibre connector. Cleaning fibre connectors For correct optical operation ensure that all optical connectors are cleaned immediately before mating using a suitable optical connector cleaning kit. If a cleaning kit is not available, wipe the end of the connector using pure isopropyl alcohol (99%) and a lint-free wipe. Dry it with filtered compressed air. Wait until dry to insert connector into the adapter. When fibre optic connectors are unmated, the optical fibre end faces must be protected from contamination using suitable dust caps. Contamination of fibre end faces will reduce the performance of the optical fibre and could ultimately cause failure of the system. Contamination could also damage the fibre end faces when the connectors are mated.

Broadband Cable Networks August 30, 2007 5(8) Connectors and plug-in slots 8906026 1 4-12 2 O E -15-8 5-4 mid attenuator optical power 3 TP 10 V/mW output TP -20 db 6 58800016_002 OLC OFF OLC ON 8 db slope flat OUTPUT 2 output module OUTPUT 1 10 9 8 7 Fig. 3. CXE800 plug-in placement 1) Integrated receiver 2) Indicator for optical input power 3) Optical power DC voltage test point 4) Midstage attenuator 5) Output test point, -20 db directional coupler 6) Output module 7) RF output port 1 8) RF output port 2 9) Slope selection 10) OLC mode jumper OLC mode jumper (Fig. 3 pos. 10) Slope selection (Fig. 3 pos. 9) Off Sloped 8 db On Flat Fig. 4. Jumper configurations.

Broadband Cable Networks August 30, 2007 6(8) Forward path / Optical receiver The optical receiver is integrated within the CXE800 and will accept both 1310 and 1550 nm wavelength optical inputs. The optical receiver provides both LED indicator and DC voltage test point for received optical power to quickly determine status of the unit. The output stage uses a GaAs MESFET output amplifier to improve RF performance over the entire 47 to 862 MHz passband. The distribution path, through the use of plug-in output modules, can be set up for a variety of output configurations. Refer to the Table 1. Output modules. Output module Attenuation at 862 MHz RF output port 1 RF output port 2 AC6112 1.6 db 12.5 db AC6116 1.1 db 15.0 db AC6119 1.1 db 20.6 db AC6124 4.0 db 4.0 db AC6128 2.5 db 8.3 db Table 1. Output modules. Optical input power Optical input power can be measured from the optical power DC voltage test point (Fig. 3 pos. 3). The test point DC voltage is directly proportional to optical input power in mw e.g. 10 V corresponds to 1.0 mw average optical power. Table below shows the correct measurements at the test point using a 1310 nm or 1550 nm transmitter. Operating wavelength 1310 nm Operating wavelength 1550 nm TP / V DC Input / dbm TP / V DC Input / dbm 10.00 0 11.2 0 7.94-1 8.87-1 6.31-2 7.05-2 5.01-3 5.60-3 3.98-4 4.45-4 3.16-5 3.53-5 2.51-6 2.80-6 2.00-7 2.23-7 Table 2. CXE800 optical receiver, expected levels. Do not connect any voltage to the test point or short circuit it to ground. Use a voltage meter with an input resistance higher than 100 kohms.

Broadband Cable Networks August 30, 2007 7(8) The mainboard provides also a LED indicator (Fig. 3 pos. 2) which gives a visual indication of the optical input power. LED on CXE800 Yellow Green Red Condition Optical input power is below -7.0 dbm Optical input power is within the nominal range (-7.0 0 dbm) Optical input power exceeds 0 dbm Table 3. LED indicator on CXE800. Forward path adjustment The following are instructions to be used for a normal adjustment procedure. 1. Do not connect fibres or apply power before all the adjustments described below have been made. 2. Test the optical input power present on the fibre service cable using an optical power meter. The CXE800 integrated optical input power range is from -7 dbm to 0 dbm. 3. Optical Level Control (OLC) circuitry provides gain control that compensates for changes in input level caused by external variations. The available gain reserve is factory-set for optimum operation. If needed the output level can be adjusted with the midstage attenuator. You can however, set an internal jumper (Fig. 3 pos. 10) to disable the OLC. This enables you to operate the CXE800 optical receiver at full gain for applications that do not require gain stabilization. 4. Use the midstage attenuator to get wanted output level. The network plan should specify exact signal levels. Refer to the Table 4 or 5. Midstage attenuator selection. Output level (dbμv) without OLC Midstage attenuator (db) 116 0 db 115 1 db 114 2 db 113 3 db 112 4 db Table 4. Midstage attenuator selection when input power is -3 dbm at 4% OMI.

Broadband Cable Networks August 30, 2007 8(8) Output level (dbμv) with OLC Midstage attenuator (db) 110 0 db 109 1 db 108 2 db 107 3 db 106 4 db Table 5. Midstage attenuator selection when input power is between 0-7 dbm at 4% OMI. 5. Use the response mode jumper (Fig. 3 pos. 9) to select the midstage slope. Available options are flat or 8 db sloped. 6. Apply the power. 7. Connect the fibre connector to the bulkhead adapter.