PRODUCT SPECIFICATIONS

Similar documents
PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS

LED Thunder S-150 Code 1097

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

PRO PAR HEX 12. User Manual

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

PART 1 PRODUCT (GENERAL)...1.

LED Spot 300W. Please read this user manual before your operation

ICOLOR210Z. Imported from China by LOTRONIC S.A. Av. Z. Gramme 9 - B-1480 Saintes

LED ZOOM PAR Please R ead O ver T his M anual B efore O perating T he L ight F ixture.

HEX16 Strip User Manual

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

Stratos Duo RGB. User Manual. Order code: EQLED371

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

LED Par 36 COB RGBW 12W, LED Par 46 COB RGBW 20W, LED Par 64 COB RGBW 60W, LED Par 56 COB RGBW 30W LED PAR. user manual

User Manual. Xstatic Pro, Inc Essex Street - Brooklyn, NY Version 1.2

Mini Stage Par 4 8W QCL RGBA/RGBW 25 /40 LED PAR. user manual

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

SquareLED - Aura Bar & Matrix Beam Light 100

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

DMX LED light effect with 4 lenses

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

WaferPar QUAD-W 7 CKU (US) / CKE (EU) USER MANUAL

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

LED Pixel Track Pro ORDERCODE 42205

Fusion 120 Zoom. User Manual. Order code: EQLED068

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

LED Pot 12 1W RGBW LED PAR. user manual

Stage Wash 7x 10W LED Moving Head (RGBW)

Hex-color RGBAW+UV LED strip light

Stage Right Party Mini-Spider 3W LED Light (RGBW)

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

Truss Light COB LED 30W

Ref. No.: LCB-48IP LED COLORUNIT 16X3W TRI DMX

LED PAR 64 floor 12x8W RGBWAUV incl. remote

ALO 060 DMX LED scanner

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

LCB-320 LED COLORS 320X10MM DMX 16SEG

TABLE OF CONTENTS. Page 2 of 16 COLORband PiX IP User Manual (Rev. 1)

Led Dynamic DMX Tri Curtain Manual

Spectra Batten (Order code: LEDJ95)

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

aorun manual V2.0 MARCH 2018

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

Mini LED Pin Spot Light Model: PLS00571

LED SPOT HEAD USERS GUIDE

Quick Reference Guide

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

LED IP65 Slimline Par RGBWA +UV 7x12W

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

USER MANUAL Table of Contents

Venus W36 LED Moving Wash

1.1 PRODUCT SPECIFICATIONS

Outdoor Stage PAR 12 3W Tri LED PAR. user manual

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

ORDER CODE: EQLED65 USER MANUAL

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc..

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

MH-X50+ LED spot moving head. user manual

USER MANUAL. B-EYE Light. Please Read Over This Manual Before Operating The Light Fixture

BROTHER, BROTHER & SONS

LED-BANK4 USER MANUAL. COLORbank 4

Elektralite LED Cool White Dazer

MHL-1410WISPOT 14X 10W QUAD DMX 2.4GHZ

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800

1. Before You Begin... 3

LED Spere Direct Control 30 ORDERCODE 41125

BROTHER, BROTHER & SONS

LED SPOT HEAD USERS GUIDE

Elektralite Dazer Downlight Warm White

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

Stage Flood QCL 24x10W, Stage Flood Inst QCL 24x10W LED floodlight. user manual

JunoScan MK-II LED scanner. user manual

1. Before You Begin... 3

9X9W LEDS BLINDER WITH LCD DISPLAY USER GUIDE December 2013 Version 1.12

TABLE OF CONTENTS. Page 2 of 25 COLORband PiX-M User Manual (Rev. 1)

LED-PAR200B USER MANUAL. COLORsplash 200B

User Manual MAINTENANCE AND CLEANING. CAUTION Disconnect from mains before starting maintenance operation. KEEP THIS MANUAL FOR FUTURE NEEDS

LED Bar 240/8 RGB LED floodlight. user manual

Owner Handbook. Jupiter Blackhole. LED UV Flood

ElektraLite lightstream

RevueLED 120 COB True White LED spotlight. user manual

Magic Cube 3D. User manual. effect panel

Outdoor Stage PAR 12 3W Tri LED PAR. user manual

USER MANUAL Table of Contents

WASH MOVING HEAD M7W15RGBW USER MANUAL. For safety, please read this user manual carefully before initial use.

USER GUIDE IRLEDS SERIES - LED PAR PROJECTORS WITH INFRARED REMOTE CONTROL

VRL PAR-1745 Par Lamp

BSL HELIOS USERS GUIDE

Crown FX PAR 77 LED spotlight. user manual

TABLE OF CONTENTS. Returns Contact Us Page 2 of 21 Intimidator Spot LED 450 User Manual Rev. 2

LEDONARDO 2 USER MANUAL. BROTHER, BROTHER & SONS ApS

180w led gobo moving USER MANUAL

USER MANUAL (SSDL-3201RGB)

Transcription:

FOS RGB Fan 1

PRODUCT SPECIFICATIONS TECHNICAL SPECIFICATION Voltage: 110/240 Volt AC, 50/60 Hz. Power Consumption: 180 Watt. Light Source: 792x 0,2 Watt RGB SMD 5050 LEDs. Effects: LEDs are separated on to two groups ( 3 & 3 fan blades ) for independent control. RGB color mixing, color macros / chases, rotation of the fan in both directions, with index function. Control: DMX, Auto, Sound. DMX Channels: 4, 8 & 11. Protection Class: IP20 (for indoor use only) Width: 700 mm Depth: 850 mm Height: 700 mm Weight: 11 Kg SAFETY WARNING This product must be installed by a qualified professional. All maintenance must be carried out by a qualified electrician. A minimum distance of 0.5 m must be maintained between the equipment and a combustible surface. The product must always be operated in a well-ventilated area. DO NOT stare directly into the light source. Always disconnect the power before carrying out any maintenance. The earth must always be connected to the ground. Ensure that all parts of the equipment are kept clean and free of dust. 2

PROTECTION AGAINST SOLIDS AND WATER Only for IP-rated fixtures The protection level of a housing is set by applied standards. For classification there is used the IP-Code. It contains the declaration IP and two following numbers. The first number characterizes the protection against harmful effects of solids, the second is rating the water protection. It is important to distinguish whether encapsulation and harmful effect! There can be housing that is not capsuled completely but still avoids harmful effect of solids or water. PROTECTION EXAMPLES: IP20: Protection against intruding objects >12,5mm Finger protected ; No waterproofing. TYPICAL PROTECTION FOR INDOOR USE FIXTURES IP33: Protection against intruding objects >2,5mm; Falling water within an angle of 60 has no harmful effect TYPICAL PROTECTION OF LED-LIGHTS USING RECESSED POWERCON AND DMX SOCKET. This protection is linked to the mounting position of the fixture and always refers to typical mounting situation like a Floor spot used standing on the ground. IP54: complete protection against solids and low-pressure water from any side THIS TYPE OF FIXTURES CAN BE USED UNDER NORMAL OUTDOOR CONDITIONS. IP65: shielded against dust and pressurized water from any side. TYPICAL PROTECTION FOR OUTDOOR RATED EVENTFIXTURES USING WATERPROOFED POWER AND SIGNAL LINK. IP67: shielded against dust and protected for accidental briefly submerge. PROTECTION AGAINST ACCIDENTIAL SUBMERGING ON TEMPORARY FLOODED AREA. TEMPORARY USE Event equipment is designed for temporary use. This are typical purpose as concerts, festivals, theatre, clubs and disco use and referable venues. Long-term use, specially under outdoor conditions and fixed outdoor installation can bring damage in aging materials and affect the coated surface. Sealings as well as cables are made from rubber material and will age by long-term UV-emission as sunlight and should be checked frequently. 3

LIMITATIONS OF IP PROTECTION IP-Rating doesn t mean unlimited outdoor use and protection against any kind of environmental influence! Especially sunlight and included UV will bring accelerated aging. Some fixtures need special parts or processes to fit the rated IP-Protection, like mounting covers or caps or similar. Sealings and other plastic or rubber materials are aging parts. They must be checked frequently to ensure the protection and safety of the fixtures. Also specified torque of screws can affect protection! Installation Hanging: The fixture can be mounted in a hanging position using the supporting bracket. The bracket should be secured to the mounting truss or structure using a standard mounting clamp. Please note that when hanging the unit, a safety cable should also be used. UPRIGHT: The fixture can be mounted in an upright or sitting position using the supporting brackets. NOTE! If the signal cable is over 60 m between the DMX512 controller and fixture or between two fixtures, then a DMX signal amplifier is needed as well. Menu Screen You can easily navigate through menu s options with the four buttons under the screen. Navigating in the menu is simple! With the Up / Down buttons, you are moving through menu s choices, pressing Enter, you are entering the sub menu of the option you have chosen, with the Up / Down buttons you re moving through the sub menu s options, with Enter, you are confirming your choice. The FOS RGB Fan offers the following options: ADDR: set the DMX address from A001 to A512 CHAN: select the control channel mode, 4, 8 or 11. 4

Auto: Soud: Activates the sound mode. FAdE: Select the color fade speed from 0 to 50. ChCL: Select the color step change speed from 0 to 50. Stro: Select the strobe speed from 0 to 50. FACh: Select the macro speed from 0 to 50. Colo: red: Adjust the RED dimmer from 0 to 255. GrEE: Adjust the GREEN dimmer from 0 to 255. blue: Adjust the BLUE dimmer from 0 to 255. Noto: Adjust the position or the rotation direction and speed of the motor. Stro: Adjust the strobe speed from 0 to 255. NorS: Select the Master (nast) or Slave (SALu) option. SEnS: Adjust the microphone sensitivity. Led: Set the LED display to stay ON or OFF after use. DISP: Reverse the LED menu display. test: Activate the test mode. BALA: Adjust the White Balance of the LEDs. Temp: Shows the fixtures temperature. Stem: Set the fan startup temperature. Ver: Shows the firmware version. Channel Modes 4 Channels 1. Red: 0 255 Red linear dimming. 2. Green: 0 255 Green linear dimming. 5

3. Blue: 0 255 Blue linear dimming. 4. Rotation: 0 127 Rotation indexing. 128 191 CW rotation from fast to slow. 192 255 CCW rotation from slow to fast. 8 Channels 1. Dimmer: Master dimmer from 0 to 100%. 2. Shutter: 0 15 Shutter Open. 16 255 Gradual strobe from slow to fast. 3. Macros: 0 15: Macros off. 16 71: Color macro 1. 72 127: Color macro 2. 128 183: Color macro 3. 184 239: Color macro 4. 240 255: Sound active. 4. Macros Speed 5. Red 6. Green 7. Blue 8. Rotation: 0 127: Rotation Index. 128 191: CW rotation from fast to slow. 192 255: CCW rotation from slow to fast. 11 Channels 1. Master Dimmer: linear dimming from 0 to 100% 2. Strobe: 0 15: Shutter Open 16 255: Strobe from slow to fast. 3. Macros: 0 15: Macros off. 16 71: Color macro 1. 72 127: Color macro 2. 6

128 183: Color macro 3. 184 239: Color macro 4. 240 255: Sound active. 4. Macro Speed 5. Red 6. Green 7. Blue 8. Red 9. Green 10. Blue 11. Rotation: 0 127: Rotation Index. 128 191: CW rotation from fast to slow. 192 255: CCW rotation from slow to fast. ** Led section A ** Led section B General Information Replacing a fuse: Always disconnect the fixture from main power before replacing a fuse. Use only the appropriate fuse, with the same type and rating. A fuse with different rating, can damage the fixture in case of failure. Risk of electric shock and / or fire: The fixture must be earthed, supplied always with its nominal voltage and cleaned periodically from dust. For cleaning use only, a moist cloth. Never use liquids or force water. After cleaning, let the fixture dry before use. The product is for indoor use only. Always turn off, unplug power and allow fixture to cool before servicing. Ensure that fixture is properly grounded. Please keep this User Guide for future consultation. Always make sure that you are connecting to the proper voltage and it s not higher than that stated on rear panel of the fixture. Be sure that no ventilation slots on the product s housing are blocked. Always disconnect from power before servicing or replacing fuse. Make sure power cord is never crimped or damaged. 7