General Specifications

Similar documents
General Specifications

General Specifications

InSight Pro. Valuable real-time process insight

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

LCOS-SLM (Liquid Crystal on Silicon - Spatial Light Modulator)

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

R&S ZN-Z154 Calibration Unit Specifications

General Specifications

ABB MEASUREMENT & ANALYTICS. MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC

PicoScope 4000 Automotive PC Oscilloscopes

R&S RT-Zxx High-Voltage and Current Probes Specifications

General Specifications

R&S ZN-Z85 Switch Matrix Specifications

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Cylindrical Photoelectric Sensor CY-100 SERIES

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

R&S ZVA110 Vector Network Analyzer Specifications

CBF500 High resolution Streak camera

Scanning System S-2100

R&S RT-Zxx High-Bandwidth Probes Specifications

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

OpticalProducts. Illuminating Your Network. Testing the World s Networks

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

PicoScope 3000 Series Automotive User guide

Multi Application Test System

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

PicoScope 4000 Series PC Oscilloscopes

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

MTS/T-BERD Platforms WDMPMD Module

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

HAL Series. Versatile range of production line testers.

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

LD OEM/LD PDS/LD PeCo

PicoScope 2000 Series PC Oscilloscopes

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Dissolved Oxygen Transmitter

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

Agilent E5100A Network Analyzer

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

Product Brochure. June M5 Series. Metal Detector

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

R&S RT-Zxx Standard Probes Specifications

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

Safety Light Curtains

R&S DST200 RF Diagnostic Chamber Specifications

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

DS2460Q QAM Analysis Meter

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Product Guide. WaveAnalyzer High-Resolution Optical Spectral Analysis

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Ethernet to VGA over IP Converter

02/11/2015

Fluke 279 FC True-rms Thermal Multimeter

IMPAC Infrared Thermometers

Driver circuit for MPPC

R-1580A Microwave Downconverter. Product Brochure

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

I/A Series Hardware Fiber Optic LAN Converter

Type SCH94FO. Type SCH94FO. Description

DT3130 Series for Machine Vision

SPATIAL LIGHT MODULATORS

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

PicoScope 6407 Digitizer

Dissolved Oxygen Transmitter

General Specifications

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

PicoScope 6407 Digitizer

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

General Specifications

LONWORKS Fibre Optic Converter

If you have questions or problems in providing anything described as Customer

Agilent 81600B Tunable Laser Source Family

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

V9A01 Solution Specification V0.1

NEXT/RADIUS Shelf Mount CCU

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Centrifuge 5418/5418 R

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

3500/42E Vibration Monitor

Transcription:

General Specifications GS 12Y03C00-01E InfraSpec TM NR801EL Fourier Transform Near-Infrared Analyzer, Desktop type Overview The NR801EL is the at-line model of NR800 series FT- NIR analyzer. It employs exactly the same hardware in the heart of the system (interferometer and detector) as NR800 process model and thus realizing high S/N (signal-to-noise) ratio, high wave number resolution and wide wavenumber scanning range those done in the NR800 process model. Direct model transfer to/ from the NR800 series including process model is another key feature. This model transfer capability will drastically cut down model implementation time and cost at project stage while it provides more flexible and efficient model upgrade during routine operation. Software specially developed for at-line model, SPECTLAND TM 2 at-line, will make operation simple and user-friendly and will improve the work efficiency for at-line and Lab. measurement application. NR801EL Note: NR801EL is designed for industrial use and cannot be used non-industrial purpose. Features Newly developed high-performance interferometer and detector High resolution: Up to 4 cm 1, user-selectable setting High S/N ratio: 2250:1 (RMS, 4 cm 1 resolution, 4100 to 4200 cm 1, 1 sec.) Wide wavelength scanning range: 900 to 2500 nm (11,000 to 4000 cm 1 ) Wavelength reproducibility: 0.007 cm 1 System Configuration Example (for Vial Cell Measurement) Wavelength accuracy: 0.04 cm 1 Calibration model transfer and share between NR800 series *1 Various types of measurement cells (cuvette, vial, probe, and flow-through, etc.,) High-speed Ethernet communication between PC and the analyzer At-line analysis software (SPECTLAND2 at-line) for simple operation. *1: This feature is available for analyzers employing identical optical system. SPECTLAND2, SPECTLAND2 at-line PC NR801EL FT-NIR Analyzer Ethernet 10Base-T communication Fiber-optic cable Printer Barcode reader Measurement cell (using a vial) Vial Barcode sheet F01.ai Related Equipment InfraSpec NR800 Fourier Transform Near-Infrared Analyzer (GS 12Y03A03-01E) InfraSpec and SPECTLAND are trademarks or registered trademarks of Yokogawa Electric Corporation. All other company and product names mentioned in this document are trademarks or registered trademarks of their respective companies. We do not use TM or mark to indicate those trademarks or registered trademarks in this document. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5617 Fax.: 81-422-52-6792 GS 12Y03C00-01E Copyright May 2003 4th Edition Dec. 28, 2015

2 1. Specifications The following specifications are based on the standard test procedure of Yokogawa Electric Corporation. Also refer to section 5, Model and Suffix s. (1) NR801EL Analyzer a. Hardware Specifications Principle: Fourier-transform Spectroscope Enclosure: Desktop type Measurement method: Transmission Sample to be measured: Liquid Classification of laser product: Class 1 Laser Product (IEC 60825-1:2007/2014) Light source: Halogen lamp (recommended replacement interval for continuous operation: 5000 hours) Detector: InGaAs photodiode Connecting to measurement cell: Fiber-optic cable Fiber-optic cable connector at analyzer: FC type Output: Ethernet (10Base-T): 1 Length of Ethernet communication cable: 3 to 40 m Installation location requirements: Refer to section 3, Installation Location Requirements Utilities: Refer to section 2, Power Supply Weight: Approx. 30 kg Wavelength scanning range: 900 to 2500 nm (11000 to 4000 cm -1 ) Wavelength resolution: 4, 8, 16, 32, and 64 cm -1 (user-selectable) Wavelength reproducibility: 0.007 cm -1 Wavelength accuracy: 0.04 cm -1 S/N ratio: 2250:1 (RMS, 4 cm -1 resolution, 4100 to 4200 cm -1, 1 sec.) b. Other Functions Baseline compensation: Up to 10 points Measurement spectrum saving c. Compliant Standard This instrument is a Class A product, and is designed for use in an industrial environment. Please use this instrument in an industrial environment only. (1) Safety CSA: C22.2 No.61010-1 Installation category (Overvoltage category) II * Pollution Degree 2 ** *: Describes a number which defines a transient overvoltage condition. It implies the regulation for impulse withstand voltage. II applies to electrical equipment which is supplied from fixed installations like distribution boards. **: Describes the degree to a solid, liquid, or gas which deteriorates dielectric strength or surface resistivity is adhering. 2 applies to normal indoor atmosphere. Normally, only non-conductive pollution occurs. (2) EMC directive Korea Electromagnetic Conformity Standard RCM Mark EN 61326-1 Class A (For use in industrial locations) (2) Fiber-optic Cable for Desktop Measurement Not only the followings but also other types of NR800 series Fiber-optic cable are available. Refer to GS 12Y03A03-01E. a. Silica Fiber-optic Cable (NR825) Applicable wavelength range: 900 to 2100 nm Connectors: FC connector on both ends, or FC connector on one end and SMA connector on the other (however, the reference cable must have FC connector on both ends). Structure: Single core, flexible type Configuration: 2 cables for measurement and 1 cable for reference Length: To be specified for measurement cable; fixed at 60 cm for reference cable Minimum bending radius: 100 mm, Lay the optic-fiber cable with large bending radius to prevent the attenuation of transmitted light. b. Fluoride Fiber-optic Cable (NR826) Applicable wavelength range: 900 to 2500 nm Connectors: FC connector on both ends, or FC connector on one end and SMA connector on the other (however, the reference cable must have FC connector on both ends). Either must be specified. Structure: Single core, flexible type Configuration: 2 cables for measurement and 1 cable for reference Length: To be specified for measurement cable; fixed at 75 cm for reference cable Minimum bending radius: 120 mm, Lay the optic-fiber cable with large bending radius to prevent the attenuation of transmitted light. (3) Measurement Cell Various types of the cell are available. Please contact with sales dept. (4) Software a. SPECTLAND TM 2 (NR831) Measurement and Maintenance Software (1) Outline SPECTLAND2 is operation and maintenance software for NR800 series FT-NIR Analyzer. Basic engineering and maintenance of NR800 is to be done through this software. SPECTLAND2 is to be installed in the Engineering PC to be connected to the analyzer. (2) Main Windows a. Manual Spectrum Window Enables the analyzer to measure spectra for Chemometrics (calibration model generation software). Spectra data is saved in the file and displayed. b. Auto Spectrum Window Allows users to upload spectra data to the PC during continuous measurement (Run/ Auto mode) at periodic intervals, upon outlier detection, or measurement value variation failure. This data is saved and displayed. c. Power Spectrum Window This window is available for C level users (maintenance personnel) and displays power spectra data. GS 12Y03C00-01E Oct. 01, 2018-01

3 d. Interferogram Window This window is available for C level users and displays collected interferogram data. e. Real-time Trend Windows Display measurement values of Nos. 1 to 6 and Nos. 7 to 12 components in two separate trend graph windows for each stream. Up to 10 windows can be open at the same time. f. Historical Trend Windows Display historical trend data. Trend data of 24 hours for each stream is saved to a file. Up to 4 windows can be open at the same time. g. Parameter Window Displays the current parameter settings for the analyzer. User B or C level users can change the settings. h. Tab-controlled Alarm Status/History Windows The Alarm Status window displays the active alarms for the analyzer, while the Alarm History window displays all the past alarms. The alarm history can be deleted with commands. i. Tab-controlled Maintenance Window Displays the A/D reference value and servorelated data of the analyzer. This window is available for C level users. j. Tab-controlled Communication Status Window Display the communication status between the PC and the analyzer. This window is available for C level users. b. SPECTLAND TM 2 at-line (NR832) At-line Measurement Software (1) Outline The SPECTLAND2 at-line is to be installed in PC to be connected to NR801EL and provides manmachine interface of NR801EL model. This software is specially developed for at-line model to suite the needs in operation and maintenance for at-line/lab. use. It also enables simplified and easy operation/ maintenance of NR801EL. (2) Major Functions a. Communication Function Communication link to NR801EL via Ethernet (10Base-T) b. Measurement Provides the following measurement options: sample measurement, blank measurement, and measurement verification (performance test with standard liquid). It allows users to decide measurement result against the criteria and if the results are acceptable, then save the data and print it (in specified print forms). The print items are selected in the Print dialog box. c. Alarming Outlier, Hi/Low limit detection for measurement value, and various system diagnostic alarms are provided. d. Barcode reader interface Barcode reader interface is provided and all the measurement conditions together with sample name are automatically set by barcode input. e. Measurement condition/parameter Set Allows users to set various conditions and parameters for communication, measurement, operator, and printing. c. Chemometrics Software (NR530) (1) Outline The NR530 is chemometrics software to generate calibration models as well as model evaluation and validation. The software to be installed on the PC. (2) Specifications Technique for Generating Calibration Models Partial least square (PLS) 2. Power Supply Item Specifications 100, 115, 200, or 230 V AC, Power supply voltage single phase, 50/60 Hz * Voltage fluctuation Rating 10 %, 50/60 ±2 Hz Power consumption Approx. 200 VA *: To be specified for ordering. For details, refer to Model and Suffix s. 3. Installation Location Requirements Location Item Ambient temperature 0 to 35 ºC Ambient humidity Vibration Atmosphere Altitude Requirements Non-hazardous location (nonexplosive atmosphere), indoors, where the analyzer shall not be exposed to weather, sunlight, or radiant heat. 0% to 80% RH (no condensation) Minimum vibration (vibration acceleration of 2 m/s 2 or less). Minimum dust and no corrosive or toxic substances. Up to 2000 m above sea level. Note; Avoid physical impact as it may result in a malfunction. 4. Recommended Specifications for PC PC Computer IBM PC/AT compatible desktop Microsoft Windows 7 Professinal 32bit SP1 Operating or system (OS) Microsoft Windows Vista Business Edition CPU 1 GHz or higher RAM 1 GB or more Hard disk space 10 GB (for program) and 25 GB (for data strage) or more Ethernet adapter 10 Base-T Display SVGA mode (1024 x 768 pixels or more) Other CD-R drive is recommended USB port (for bar code reader) Color printer Prepare if necessary. Connection Cables and other Devices Prepare if necessary. Electrical Cable for Ethernet Specifications: 10Base-T, 8 core shielded Length: 3 to 40 m GS 12Y03C00-01E Dec. 28, 2015-00

4 Barcode Reader (for SPECTLAND2 at-line) Interface: USB Reading width: At least 65 mm Resolution: 0.125 mm Reading code: CODE39 5. Model and Suffix s 5.1 NR801EL Desktop Analyzer Model Suffix Option Description NR801EL FT-NIR Analyzer, desktop type Language -E English Power supply 1 3 4 6 Power cable -00-01 -02-03 -04-05 100 V AC ±10%, 50/60 Hz 115 V AC ±10%, 50/60 Hz 200 V AC ±10%, 50/60 Hz 230 V AC ±10%, 50/60 Hz Number of measuring channels -S1 Single channel Wavelength scanning range W1 W2 No power cable attached For U.S.A. and Japan (UL/CSA) For Germany (VDE) For Australia (SAA) For UK (BS) For China (CCC) 900 to 2100 nm 900 to 2500 nm - -21 Always -21 - -00 Always -00-0 Always 0 - -0000 Always -0000 5.2 Fiber-optic Cable for Desktop Measurement (1) Silica Fiber-optic Cable Model Suffix Option Description NR825 Silica fiber-optic cable for At-line model Connector Cable length (cm) -FF -FS -L060 -L150 -L250 FC connector at both ends FC at analyzer, SMA at cell/probe 60 150 250 - -000 Always -000 (2) Fluoride Fiber-optic Cable Model Suffix Option Description NR826 Fluoride fiber-optic cable for At-line model Connector Cable length (cm) -FF -FS -L075 -L150 -L250 FC connector at both ends FC at analyzer, SMA at cell/probe 75 150 250 - -000 Always -000 GS 12Y03C00-01E Dec. 28, 2015-00

5 5.3 Software (1) SPECTLAND2 Model Suffix Option Description NR831 Measurement and maintenance software Language -E English Option /UP Version up Package contents: One CD-ROM One instruction manual (2) SPECTLAND2 at-line Model Suffix Option Description NR832 At-line measurement software Language -E English Option /UP Version up Package contents: One CD-ROM One instruction manual (3) Chemometrics Software Model Suffix Option Description NR530 Chemometrics software Language -E English Package contents: Two CD-ROM (Install disc/user's manual) One set of user registration document GS 12Y03C00-01E Dec. 28, 2015-00

6 6. Outline Drawing 6.1 Analyzer (NR801EL) Z view Unit; mm Z view Power connector Fiber-optic cable connection (output) Fiber-optic cable connection (input) Ethernet connector (10Base-T) 400 POWER(G) ALARM(R) Infra Spec NR800 FOURIER TRANSFORM NEAR INFRARED ANALYZER LIGHT OUT REF SMPL LIGHT IN SMPL REF 220 550 10 390 16 Coating Color Cover: Frosty white (Munsell No.: 2.5Y 8.4/1.2) Main body: Lamp blank (Munsell No.: 08Y 2.5/0.4) GS 12Y03C00-01E Oct. 01, 2018-01

7 6.2 Fiber-optic Cable (1) Silica Fiber-optic Cable for At-line Model (NR825) FC connector (on both ends) Fiber sheath: Vinyl chloride Unit: mm (ø2.8) ø10 42 L±20 42 L: 600, 1500, 2500 F03.ai Note 1: When ordering optical fiber as per MS code. 2 measurement cable and 1 reference cable come together. Dimension and shape of cable are identical for both measurement and reference cable. The above drawing is an example of fiber with FC connectors. The length (L) of each measurement cable must be specified in reference to Model and Suffix s for ordering. The length of the reference cable is fixed at 60 cm. Note 2: The figure above shows an example of a cable with an FC connector on both ends. Shape and dimensions for a cable with FC and SMA connectors differs from the shown above. (2) Fluoride Fiber-optic Cable for At-line Model (NR826) FC connector (on both ends) Stainless steel tube Unit: mm (ø0.8 or ø1.1 (claded tube)) ø10 19.5 L 19.5 L: 750±20, 1500±50, 2500±50 F04.ai Note 1: When ordering optical fiber as per MS code. 2 measurement cable and 1 reference cable come together. Dimensions and shape of cable are identical for both measurement and reference cable. The above drawing is an example of fiber with FC connectors. The length (L) of each measurement cable must be specified in reference to Model and Suffix s for ordering. The length of the reference cable is fixed at 75 cm. Note 2: When a cable length is 75 cm, a stainless steel tube is coverd with a polyimide tube. Note 3: The figure above shows an example of a cable with an FC connector on both ends. Shape and dimensions for a cable with FC and SMA connectors differs from the shown above. 7. Installation Space 50 550 50 Unit: mm 50 400 NR801EL 800 350 Maintenance space 650 F05.ai GS 12Y03C00-01E Dec. 28, 2015-00

8 8. Support for Calibration Model Generation (1) On-site Guidance of Calibration Model Generation A Yokogawa engineer will train an user's site personnel in the procedure to generate a calibration model for one measured item using a user-provided sample with its laboratory analysis results. (2) Calibration Model Generation Yokogawa generates a calibration model using the necessary quantity of user-provided samples with laboratory analysis results. A predefined SEP (standard error of prediction) value of 1σ will be used as the measurement target value. The target value, sample quantity, and other details are determined separately for each application. (3) Others Other support options for calibration model generation and maintenance include: Sampling test for potential users Maintenance contracts Sampling/model generation/maintenance consulting service. Contact a Yokogawa sales representative for further information, and advice on the best solution for your needs. All other company and product names mentioned are trademarks or registered trademarks of their respective companies. Subject to change without notice. GS 12Y03C00-01E Dec. 28, 2015-00