Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Similar documents
I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Minicontactorrelay,2NO/2NC,DCoperated

Type: DILM25 10(24V50HZ) Article No.:

Type: DILM12 10(24VDC) Article No.:

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Series CT7N Bimetallic Overload Relays

AS09..S 3-pole Contactors - Spring Terminals

Datasheet - SRB-E-201ST

Datasheet - SRB301LC 24VAC/DC

Bulletin 190 IEC Modular Starter System

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

02/11/2015

High performance circuit breakers

Ordering details. Approval. Classification

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

TeSys circuit-breakers

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Modular pulse operated latching relay 16 A

A V 50Hz / V 60Hz

Circuit breakers BZM. Circuit breakers BZM

GV2P05. Main. Device short name. Device application

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

GV2ME. Main. Device short name. Device application

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

DMX and 4000 air circuit breakers from 800 to 4000 A

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

LED control gear Compact fixed output

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Magnetic and Hydraulic-Magnetic Circuit Breaker

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

llen-bradley 194R-HM4-NFPA3

GV2ME. Main. Device short name. Device application

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

LED Driver Compact dimming

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LED Driver Compact fixed output

LED Driver Compact fixed output

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Power Circuit of a UL508A Panel. Typical UL489 Application

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Circuit-Breakers for Motor Protection Series 8523/8

LED Driver Linear / area fixed output

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

GR circuit breaker - hydraulic magnetic, Datasheet

15 Series - Dimmer

Features XT SC 012 B B A

Kuhnke Technical Data. Contact Details

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Features XT SC 012 B B A

Manual Motor Starter Specifcations

GR circuit breaker - hydraulic magnetic, Datasheet

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

3AH3 Vacuum Circuit-Breakers

KRF EMC Filters Installation, Operation and Maintenance Manual

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

16 A and 25 A power contactors with or without handle

Magnecraft Power Relays

LED MODULES READYLINE DL

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Process transmitter RMA422

Assembly. Front view. LEDs. Parametrization interface. Power Bus

SURGE PROTECTIVE DEVICES

Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31

Generator protection relay

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

DIN Power Module - Phase Adaptive

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Transcription:

Circuit-breaker,4p,63A Partno. NZMH1-4-A63 Articleno. 284426 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type Fixed Release system Thermomagnetic release Construction size NZM1 Description Set value in neutral conductor is synchronous with set value Ir of main pole. Number of poles 4 pole Standard equipment Box terminal Switchingcapacity 400/415 V 50 Hz I cu ka 100 Ratedcurrent=rateduninterruptedcurrent Rated current = rated uninterrupted current I n = I u A 63 Neutral conductor Settingrange Overload trip % of phase conductor CSA 100 I r A 50-63 Main pole I r A 50-63 Short-circuit releases Non-delayed I i = I n x 6-10 Short-circuit releases I rm A 380-630 Technicaldata General Standards IEC/EN 60947 Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Ambient temperature, storage C - 40 - + 70 Operation C -25 - +70 Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 Safe isolation to EN 61140 g 20 (half-sinusoidal shock 20 ms) Between auxiliary contacts and main contacts V AC 500 between the auxiliary contacts V AC 300 12/16/2016 284426 - HPL-ED2016 V27.0 EN 1 / 10

Mounting position Vertical and 90 in all directions With residual-current release XFI: - NZM1, N1, NZM2, N2: vertical and 90 in all directions with plug-in adapter elements - NZM1, N1, NZM2, N2: vertical, 90 right/left with withdrawable unit: - NZM3, N3: vertical, 90 left - NZM4, N4: vertical with remote operator: - NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90 in all directions Direction of incoming supply as required Degree of protection Device In the operating controls area: IP20 (basic degree of protection) Enclosures With insulating surround: IP40 With door coupling rotary handle: IP66 Terminations Tunnel terminal: IP10 Phase isolator and strip terminal: IP00 Other technical data (sheet catalogue) Weight Temperature dependency, Derating Effective power loss Circuit-breakers Rated current = rated uninterrupted current I n = I u A 63 Rated surge voltage invariability U imp Main contacts V 6000 Auxiliary contacts V 6000 Rated operational voltage U e V AC 690 Details apply for 3 pole system protection circuit-breaker with thermomagnetic release NZMN(H)1(2)(3)-A to 500 A. For rated operating voltage switching via 3 contacts: DC correction factor for instantaneous release response value: NZM1: 1.25, NZM2: 1.35, NZM3: 1.45 Set value for I i at DC = set value I i AC/correction factor DC Circuittype:2pole,+ and-,twosides Circuittype:1pole,+ or-,twosides Overvoltage category/pollution degree III/3 Rated insulation voltage U i V 690 Use in unearthed supply systems V Switchingcapacity 690 Rated short-circuit making capacity I cm 240 V I cm ka 220 400/415 V I cm ka 220 440 V 50/60 Hz I cm ka 74 525 V 50/60 Hz I cm ka 40 690 V 50/60 H Ic ka 17 Rated short-circuit breaking capacity I cn I cn Icu to IEC/EN 60947 test cycle O-t-CO Icu ka 240 V 50/60 Hz I cu ka 100 400/415 V 50/60 Hz I cu ka 100 440 V 50/60 Hz I cu ka 70 12/16/2016 284426 - HPL-ED2016 V27.0 EN 2 / 10

525 V 50/60 Hz I cu ka 20 690 V 50/60 Hz I cu ka 10 Ics to IEC/EN 60947 test cycle O-t-CO-t-CO Ics ka 240 V 50/60 Hz I cs ka 100 400/415 V 50/60 Hz I cs ka 50 440 V 50/60 Hz I cs ka 35 525 V 50/60 Hz I cs ka 10 690 V 50/60 Hz I cs ka 7.5 500 V DC I cs ka 30 Utilization category to IEC/EN 60947-2 A Rated making and breaking capacity Rated operational current I e A AC-1 AC--3 380 V 400 V I e A 63 415 V I e A 63 690 V I e A 63 380 V 400 V I e A 63 415 V I e A 63 660 V 690 V I e A 63 Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release) Operations 20000 Lifespan, electrical AC-1 AC--3 400 V 50/60 Hz Operations 10000 415 V 50/60 Hz Operations 10000 690 V 50/60 Hz Operations 7500 400 V 50/60 Hz Operations 7500 415 V 50/60 Hz Operations 7500 690 V 50/60 Hz Operations 5000 Max. operating frequency Ops/h 120 Total downtime in a short-circuit ms < 10 Terminalcapacity Standard equipment Box terminal Optional accessories Screw connection Tunnel terminal connection on rear Round copper conductor Box terminal Solid 2 mm 1 x (10-16) 2 x (6-16) Stranded mm 2 1 x (10-70) 3) Tunnel terminal Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker. 2 x (6-25) Solid mm 2 1 x 16 Stranded mm 2 Stranded 2 mm 1 x (25-95) Bolt terminal and rear-side connection Direct on the switch Solid 2 mm 1 x (10-16) 2 x (10-16) Stranded mm 2 1 x (25-70) 3) 3) Up to 95 mm² can be connected depending on the cable manufacturer. 2 x 25 12/16/2016 284426 - HPL-ED2016 V27.0 EN 3 / 10

3) Up to 95 mm² can be connected depending on the cable manufacturer. Al conductors, Cu cable Solid mm 2 1 x 16 Stranded mm 2 Stranded 2 mm 1 x (25-95) Cu strip (number of segments x width x segment thickness) Box terminal Copper busbar (width x thickness) mm Bolt terminal and rear-side connection min. mm 2 x 9 x 0.8 max. mm 9 x 9 x 0.8 Screw connection M6 Direct on the switch Control cables min. mm 12 x 5 max. mm 16 x 5 2 mm 1 x (0.75-2.5) 2 x (0.75-1.5) DesignverificationasperIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 63 Equipment heat dissipation, current-dependent P vid W 14.17 Operating ambient temperature min. C -25 Operating ambient temperature max. C 70 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM6.0 12/16/2016 284426 - HPL-ED2016 V27.0 EN 4 / 10

Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228) Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kv) / Circuit breaker for power transformer, generator and system protection (ecl@ss8.1-27-37-04-09 [AJZ716010]) Rated permanent current Iu A 63 Rated voltage V 690-690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz ka 100 Overload release current setting A 50-63 Adjustment range short-term delayed short-circuit release A 0-0 Adjustment range undelayed short-circuit release A 380-630 Integrated earth fault protection No Type of electrical connection of main circuit Frame clamp Device construction Built-in device fixed built-in technique Suitable for DIN rail (top hat rail) mounting No DIN rail (top hat rail) mounting optional Yes Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as change-over contact 0 Switched-off indicator available No With under voltage release No Number of poles 4 Position of connection for main current circuit Front side Type of control element Rocker lever Complete device with protection unit Yes Motor drive integrated No Motor drive optional No Degree of protection (IP) IP20 12/16/2016 284426 - HPL-ED2016 V27.0 EN 5 / 10

Characteristics 12/16/2016 284426 - HPL-ED2016 V27.0 EN 6 / 10

12/16/2016 284426 - HPL-ED2016 V27.0 EN 7 / 10

12/16/2016 284426 - HPL-ED2016 V27.0 EN 8 / 10

Dimensions Blow out area, minimum clearance to adjacent parts 12/16/2016 284426 - HPL-ED2016 V27.0 EN 9 / 10

Additionalproductinformation(links) IL01203004Z(AWA1230-1913)Circuit-breaker,Switch-Disconnector IL01203004Z (AWA1230-1913) Circuit-breaker, Switch-Disconnector Weight Temperature dependency, Derating Effective power loss CurveSelect characteristics program ftp://ftp.moeller.net/documentation/awa_instructions/il01203004z2015_11.pdf http://ecat.moeller.net/flip-cat/?edition=hplen&startpage=17.171 http://ecat.moeller.net/flip-cat/?edition=hplen&startpage=17.172 http://ecat.moeller.net/flip-cat/?edition=hplen&startpage=17.174 http://www.eaton.eu/de/europe/electrical/customersupport/configurationtools/characteristicsprogram/index.htm 12/16/2016 Eaton Industries GmbH http://www.eaton.eu 11/2016 by Eaton Industries GmbH 284426 - HPL-ED2016 V27.0 EN 10 / 10