SmartMix Manual V5350A

Similar documents
Control Unit CU 2.1 User Manual V6850A HPLC

Operation Manual VMS 3.0 Video System

eblot L1 Protein Transfer System Fast Wet Transfer System for Mini Gels

VPM2. Operation Manual

Better dispensing, better results.

MITS Series T5 QUICK GUIDE. Simulated laparoscope. LCD monitor On/off switch Work area light switches Ports for trocars and or.

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

Gear Pump Units For single-line centralized lubrication systems

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

SIM 5 series Lamp Kit

HPLC Tips and Tricks. Tiziana Ladisa Sales Support Specialist for Chromatography Italy Thermo Fisher Scientific, Rodano (MI)

ENGLISH Antenna Distributor

Tube Rotator. User Guide. Version 1.2

Litile34 OPERATION MANUAL

Operation Manual for the Refractive Index detector VE-3580

Litile34 INSTALLATION MANUAL

MEISHU Phono INTEGRATED AMPLIFIER OWNER S INFORMATION

Tube Roller Shakers. User Guide. Version 1.2

Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer

CONQUEROR STEREO POWER AMPLIFIER OWNER S INFORMATION

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Colour Explosion Proof Video Camera USER MANUAL VID-C

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

POL-200 Semiautomatic Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Installation instruction FISTUNE antenna module Audi A6 Sedan 4G, Avant 4G

TRF STEP-DOWN TRANSFORMER USER MANUAL

HulaMixer Sample Mixer

2178-L/S Series Fiber Optic Splice Case with Gasket

e 835 Instruction manual Stage Microphones

WID-DL74 WID-DL74 BLP WID. Designed for. Installation guide for workitdesk interactive table for. BrightLink Pro

MANUAL ENGLISH Core Club Ordercode: D2314

OPERATION AND MAINTENANCE MANUAL

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

LCD Thermometer / Clock S No. 1253

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

Model KBF 720 Constant climate chambers with large temperature / humidity range

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

Metal and Glass TV Stand for TVs up to 65 or 110 lbs. NS-HMG1856

Contents. Disclaimer of Product and Services Warnings and Precautions Standard Warranty Two Year Warranty Introduction...

VK-P10SE WARRANTY REGISTRATION FORM

Manual. racing Micro Magic HoTT. ARTR RC sail-boat with HoTT receiver HoTT

VPM2. Operator's Manual

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

TVAC20000 User manual

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Operation Manual. Diaphragm pumps 4-headed. MP 301 Vp, MPC 301 Vp MP 601 Tp, MPC 601 Tp MP 901 Zp, MPC 901 Zp MP 1201 Ep, MPC 1201 Ep

BISON 500 USER'S MANUAL. IGS Audio Igor Sobczyk 3 Maja 76d, Mysłowice, Poland ph:

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

Model KBF 115 Constant climate chambers with large temperature / humidity range

Gear Pump Units. For single-line lubrication systems

KHT 1000C HV-Probe Calibrator. Instruction Manual

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

Laser Aiming Device. Installation Guide. for use with:

PEGAS 160 T PULSE HF PEGAS 200 T PULSE HF

e 935 Instruction manual Stage Microphones

Operating Instructions

Viztrac AM200 User s Guide. Page 1 of 12

VGAD-12 ORDERCODE

Operating instructions

Advanced Digital Melting Point Apparatus

.Power Distribution Center. PD-1. Instruction Manual

Buffer Tube Midspan Access Tool Accessing fibers in buffer tube procedure

Widescreen Headrest Monitor

LED Pixel Track V3 ORDERCODE 42200

APSPB PUSH BUTTON ZERO Installation Manual

OTO Phono SE Signature

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

TO THE INSTALLER: BE SURE TO LEAVE THIS MANUAL WITH THE OWNER.

Gardner Liquid Color Standards Instruction Manual

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

Model KBF 1020 Constant climate chambers with large temperature / humidity range

LED Par 56 Short Eco V2 ORDERCODE 42417

User Manual. Tensioned Screens. Website: Tel:

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

OWNER'S MANUAL MYCRO SUB

MKH 8060 Directional studio microphone

PRO Mixer Distro User Guide

Atlas SCR. User Guide. Thyristor and Triac Analyser Model SCR100

18W Low Energy Dusk-Dawn Bulkhead E-290B

USERS MANUAL GR ONE 300 GR ONE 700 GR ONE 1400

Install Guide Incredible Technologies, Inc. All Rights Reserved

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

LED Thunder S-150 Code 1097

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

MARINE HORNS V-1030M - 5 WATT PAGING HORN AMPLIFIER ASSEMBLY V-1036M - 15 WATT PAGING HORN AMPLIFIER ASSEMBLY V-1048M - 45 OHM TALKBACK HORN

User Manual. Adjustable Speed Vortex. Fixed Speed Vortex

RLM W-series multifunctional frame

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

Staying Connected in GC

K-112 ORDERCODE D3551

Electric Motorized Projection Screen Spectrum Series

QLOCKTWO CLASSIC. Instructions for use

Operation Manual for. SCU1 Signal Conditioning Unit

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

Headrest Monitor Directed Electronics N

sequenza 1000/1250 al manuale di istruzioni instruction manual 1^ edizione, ottobre st edition october 1996

Transcription:

SmartMix Manual V5350A

3 Table of contents Overview................................................... 4 Features.................................................... 4 Scope of delivery................................................ 4 SmartMix mixer.............................................. 4 Accessories and spare parts...................................... 5 Checking the scope of delivery................................... 5 Intended use................................................ 5 Safety..................................................... 6 Protective measures.............................................. 6 Target group................................................... 6 What expertise should users have to safely operate an HPLC system?...... 6 Symbols and labels.............................................. 6 Installation.................................................. 6 Packaging and transport.......................................... 6 Overview SmartMix mixer......................................... 7 Mounting on the pump.......................................... 8 Installation in the LPG system...................................... 8 Installation in the HPG system...................................... 9 Maintenance and care........................................ 10 Opening the SmartMix mixer..................................... 10 Exchanging the filter system...................................... 10 Replacing the cartridge.......................................... 11 Product range.............................................. 12 Device, accessories, and spare parts................................ 12 Troubleshooting............................................ 13 Technical data.............................................. 13 Legal information........................................... 14 Warranty conditions............................................ 14 Declaration of conformity........................................ 15 V5350A

4 SmartMix mixer Overview The KNAUER SmartMix mixers are solvent mixers that are suitable for high-performance liquid chromatography (HPLC). The liquids are mixed statically in the SmartMix mixer. Features The direction of flow has no influence in SmartMix technology. For this reason, the SmartMix mixer can be used for low-pressure gradient systems (LPG) as well as for high-pressure gradient systems (HPG). The SmartMix mixer is specially designed for the application of the following mixtures of solvents: Water-acetonitrile mixture Water-methanol mixture Buffer-salt solution mixture The SmartMix mixer is available in two versions: Analytical version Micro version Both versions can be used for pressures up to 1000 bar. Wetted materials are stainless steel, PEEK and Teflon. To adapt the mixture volume, two versions of cartridges can be inserted in the SmartMix mixer. Analytical cartridge (350 μl mixture volume) Micro cartridge (100 μl mixture volume) The dimensions of the cartridges are identical, so that a switch from the analytical cartridge to the micro cartridge is possible. Scope of delivery SmartMix mixer SmartMix mixer Red or black PEEK blind plug Manual

5 SmartMix mixer Accessories and spare parts Analytical cartridge Micro cartridge Mounting kit: two filler caps made of stainless steel four Phillips-head screws four washers four hexagon screws Use original parts and accessories Spare filter kit: three filter inserts PEEK sealing ring Only use original parts and accessories made by KNAUER or a company authorized by KNAUER. Checking the scope of delivery 1. Check whether the supplied devices and accessories are complete. 2. If a part should be missing, inform the technical support of KNAUER. Intended use HPLC Checking intended use High-performance liquid chromatography (HPLC) is a method for separating substance mixtures and for determining substances and measuring their concentration. The device or device system is suited for high-performance liquid chromatography. It is used for analyzing substance mixtures that can be dissolved in a solvent or a solvent mixture. Laboratory use: Biochemistry analyses Chiral analyses Food analyses Pharmaceutical analyses Environmental analyses Only use the device for applications that fall within the range of the intended use.

6 SmartMix mixer Safety Protective measures Only perform maintenance tasks described in this manual. All other maintenance tasks are to be performed exclusively by KNAUER or a company authorized by KNAUER. Target group What expertise should users have to safely operate an HPLC system? Completed qualification as chemical laboratory technician or comparable vocational training Fundamental knowledge of liquid chromatography Knowledge regarding substances that are suitable only to a limited extent for use in liquid chromatography Symbols and labels Explanations of symbols and labels on the system Symbol Explanation For your own safety, read the operating instructions and always observe the warnings and safety information on the device and in the operating instructions! Installation Checking for signs of damage during transport Packaging and transport At the factory, the HPLC devices are carefully and safely packed for the transport into special shipping boxes. Check the device for signs of damage during transport. If the shipment is incomplete or damaged, inform the manufacturing factory within three workdays. Also inform the freight carrier about any transport damage.

7 SmartMix mixer Overview SmartMix mixer Legend A PEEK blind plug (red or black) B Mixer lid Front view A B C C Inlet to the pump D Mixer housing E Mounting boreholes D E F Micro cartridge inside the SmartMix F G Outlet to the column G Fig. 1 SmartMix mixer with micro cartridge The SmartMix mixer consists of three subassemblies: Mixer lid (C), mixer housing (D), cartridge (F). To differentiate the installed cartridges, the SmartMix mixer is supplied with different PEEK blind plugs: The analytical version with the analytical cartridge has a black blind plug. The micro version with the micro cartridge has a red blind plug. ATTENTION! Avoid leaks! Before the first use, always replace the red or black PEEK blind plug in the LPG system by a metal screw fitting (mounting kit Z5350A). Otherwise, there may be a leak.

8 SmartMix mixer Mounting on the pump The SmartMix mixer is secured with two screws on the housing of the pump. Legend A Metal screw fitting as blind plug B Assembly screws for SmartMix mixer C Capillary to pump D Inlet for piston backflushing E Front panel F Pump head G Pressure sensor and venting valve H Mixing chamber I Capillary to tube Exterior view A B C D E I H G F Fig. 2 Mounting SmartMix mixer on the pump 1. Mount the SmartMix mixer to the front panel (E) of the pump by two Phillips-head screws (B). 2. Tighten the screws with a Phillips screwdriver (PH1 80). Installation in the LPG system For use in a low-pressure gradient system, the SmartMix mixer is mounted according to fig. 3. Legend A Metal screw fitting B Inlet to the pump C Mixer lid D Mixer housing E Outlet to the column Schematic diagram A B C E D Fig. 3 Installation SmartMix mixer in the LPG system

9 SmartMix mixer 1. Close the left connection in the LPG system with the metal screw fitting (A). Tighten the screw with a size 10 wrench. ATTENTION! Avoid possible leaks! Before the first use, always replace the red or black PEEK blind plug in the LPG system by a metal screw fitting (mounting kit Z5350A). Otherwise, there may be a leak. 2. Connect the capillary leading to the pump by the right inlet to the pump (B) on the mixer lid (C). 3. Connect the capillary leading to the column with the outlet to the column (E). Installation in the HPG system For use in a high-pressure gradient system, the SmartMix mixer is mounted according to fig. 4. Legend A Inlet to the pump A B Inlet to the pump B C Mixer lid D Mixer housing E Outlet to the column Schematic diagram A B C D E Fig. 4 Installation SmartMix mixer in the HPG system 1. Two pumps are used in the HPG system. Connect the Smart- Mix mixer to the bottom pump. 2. Connect the capillaries from pump A and pump B with the two inlets to the pumps (A and B) on the mixer lid (C). 3. Connect the capillary leading to the column with the outlet to the column (E).

10 SmartMix mixer Maintenance and care Opening the SmartMix mixer Opening the mixer lid of the SmartMix mixer Steps Figure 1. Screw out the four hexagon screws (A) of the mixer lid (B) with an Allen wrench (SW 3.0 150). 2. Lift off the mixer lid. Exterior view A B Fig. 5 Mixer lid Exchanging the filter system Functional principle Several filter inserts are inserted into the SmartMix mixer in a specific order. They can be renewed as needed. Prerequisite The SmartMix mixer has been removed. The mixer lid of the SmartMix mixer is opened. Replacing the filter system Steps Figure 1. Remove the filter system (A) in the mixer lid (B) with a pair of pointed tweezers. Internal view A B Fig. 6 Remove the filter system from the mixer lid

11 SmartMix mixer Replacing the filter system Steps Figure Note: Observe the sequence when inserting the new filter inserts! Otherwise, the filters will plug up. 2. Insert the new filter system at position (A) in the following order: - 2 units filter sieves 7 μm (C); order number: M1893-2 units glassfiber filter (D); order number: 1894-2 units filter sieves 3 μm (E); order number: 1892 Sequence filter inserts from top to bottom Fig. 7 Insert new filter system in the mixer lid E C D F Note: Put on the mixer lid with the screw fittings of the capillaries (F) as shown in the picture. 3. Put the mixer lid with the replaced filter system onto the mixer housing with the cartridge and the PEEK sealing ring. 4. Screw tight the four hexagon screws on the mixer lid with an Allen wrench (SW 3.0 150). Replacing the cartridge The design of the cartridges is different, depending on the version of the SmartMix mixer (see fig. 8). The micro cartridge (A) has a circumferential groove. The analytical cartridge has no groove (B). Legend A Micro cartridge with circumferential groove B Analytical cartridge View of the filter cartridges A B Fig. 8 Cartridges for different mixture volumes Prerequisite The capillaries were loosened. The SmartMix mixer has been removed.

12 SmartMix mixer Procedure Loosen and lift off the mixer lid. Remove the PEEK sealing ring. Replace the cartridges. Put PEEK sealing ring back on Note: Do not use any metal tools to take the cartridge out of the housing. Otherwise, damage might be done to the seals of the cartridge. A 1. Take the PEEK sealing ring, lying on the cartridge, off the cartridge. Check the PEEK sealing ring for any possible damage; replace sealing ring if necessary (filter insert kit A0164-1). 2. Take cartridge out of the housing. 3. Insert the new cartridge. The insertion direction does not matter. Do not remove the filters in the lid. 4. Place the PEEK sealing ring on the cartridge. Note: Put on the mixer lid with the screw fittings of the capillaries (A) as shown in the picture. 5. Put the mixer lid onto the mixer housing with the cartridge and the PEEK sealing ring. 6. Screw tight the four hexagon screws on the mixer lid with an Allen wrench (SW 3.0 150). Product range Device, accessories, and spare parts Name SmartMix mixer 350 SmartMix mixer 100 Analytical cartridge (350 μl) Micro cartridge (100 μl) Mounting kit: 2 filler caps made of stainless steel 4 Phillips-head screws 4 washers 4 hexagon screws SmartMix filter insert kit: 3 filter units 1 PEEK sealing ring for the cartridge Order number A5350 A5351 A5356 A5355 Z5350A A0164-1

Troubleshooting 13 SmartMix mixer Problem Possible cause Remedy Technical data Filter clogged Unsteady baseline The pump was switched off automatically, because Pmax was exceeded. Pressure increase Filter system inserted wrong Cartridge faulty Filter clogged Exchange the filter system Replace cartridge Exchange the filter system Replace cartridge Exchange the filter system SmartMix mixer Flow rate Gradient system LPG HPG Analytical version 0.5 2.0 ml/min < 5 ml/min Micro version 0.1 0.5 ml/min < 1.5 ml/min Cartridge Analytical cartridge Micro cartridge 350 μl mixture volume 100 μl mixture volume

14 SmartMix mixer Legal information Manufacturer Warranty conditions The factory warranty for the device is valid for 12 months after the date of dispatch. All warranty claims shall expire in the event that any unauthorized changes are made to the device. During the warranty period, any components with material or design-related defects will be replaced or repaired by the manufacturer free of charge. This warranty excludes the following: 1. Accidental or willful damage 2. Damage or errors caused by third parties that are not contractually related to the manufacturer at the time the damage occurs 3. Wear parts, fuses, glass parts, columns, light sources, cuvettes and other optical components 4. Damage caused by negligence or improper operation of the device and damage caused by clogged capillaries 5. Packaging and transport damage In the event of device malfunctions, contact: Wissenschaftliche Gerätebau Dr. Ing. Herbert KNAUER GmbH Hegauer Weg 38 14163 Berlin, Germany Telephone: +49-(0)30-809727-0 Fax: +49-(0)30-8015010 E-mail: info@knauer.net Internet: www.knauer.net The packaging of our devices provides the best possible protection against transport damage. However, immediately inspect each delivery for visible signs of transport damage. If the shipment is incomplete or damaged, inform the manufacturer within three workdays. Also inform the freight carrier about transport damage.

15 SmartMix mixer Declaration of conformity Manufacturer name and address SmartMix mixer Wissenschaftliche Gerätebau Dr. Ing. Herbert KNAUER GmbH Hegauer Weg 38 14163 Berlin, Germany Order number A5350, A5351 DIN EN 60799 (June 1999) Electrical accessories - Cord sets and interconnection cord sets DIN EN 61010-1 (August 2002) Safety requirements for electrical equipment for measurement, control and laboratory use Low voltage directive (2006/95/EC) DIN EN 61000-3-2 (March 2010) Electromagnetic compatibility (EMC) Part 3-2 EN 61000-3-2:2006 + A1:2009 + A2:2009 EMC standarts (2004/108/EC) DIN EN 61326-1 (October 2006) Electrical equipment for measurement, control and laboratory use EMC requirements DIN EN 61326-1 Corrigendum 2 (April 2011) Directives for an environmentally sound use of electrical and electronic equipment RoHS directive 2002/95/EC (February 2003) on the restriction of the use of certain hazardous substances in electrical and electronic equipment WEEE directive 2002/96/EC (February 2003) on waste electrical and electronic equipment Berlin, 2011-06-27 Dr. Alexander Bünz (Managing Director) The mark of conformity has been applied to the rear panel of the device.

Wissenschaftliche Gerätebau Dr. Ing. Herbert Knauer GmbH All rights reserved. The information in this document is subject to change without prior notice. Translation of the original German edition of this device manual. 2011-06-27 Printed in Germany. www.knauer.net HPLC SMB Osmometry Wissenschaftliche Gerätebau Dr. Ing. Herbert Knauer GmbH Hegauer Weg 38 14163 Berlin, Germany Phone: +49-(0)30-809727-0 Fax: +49-(0)30-8015010 e-mail: info@knauer.net Internet: www.knauer.net