Lighted Pushbutton Switch (Square) Ultra Bright LED Type

Similar documents
M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

Selector Switches 30-mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Operation Unit Colors

Model Number Structure

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Indicator (Square) Ultra Bright LED Type

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

Accessories (Order Separately)

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

K3MA-L. Model Number Structure. Ordering Information. Temperature Meter. Model Number Legend. List of Models

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Type Contact form Model

Solid-State Digital Timer

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnecraft Power Relays

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Photoelectric Sensors E3F2

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Model Number Structure

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

EZ-LIGHT K30L Series With Independent Push Button Contact

EZ-STATUS WLS28-2 Multicolor LED Strip Light

Multifunction Digital Timer

Instructions. P MHz 1X/10X Passive Probe

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

WLS27 Multicolor LED Strip Light with EZ-STATUS

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

LW Series offer flexibility in space-saving package

LH1D Series Surface Mount Indicators

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Absolute Rotary Encoder E6CP

Easy and Quick "Checking Power" at the Worksite

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Model: HDCMP31. Installation Guide

OPERATION AND MAINTENANCE MANUAL

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

Self--powered Time Counter

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON


USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Surface Mount Multilayer Ceramic Chip Capacitors for High Temperatures 200 C

LED Series Sealed Backlights

American Power Design, Inc.

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

Electronic M.O.P Card. Instruction Manual Model D

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

02/11/2015

Cylindrical Photoelectric Sensor CY-100 SERIES

WLC60 Heavy Duty LED Light - PWM Dimmable

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

MILITARY SPECIFICATION SHEET

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Installation Manual SaVi Note Underwater LED Light

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

AGS Low profile capacitive air gap measuring sensor for rotating machines

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Model Number ALS-ELUM-RGB-CNTRL-1. elum RGB Controller

KHT 1000C HV-Probe Calibrator. Instruction Manual

Linear Array with Intensity Adjustment

Datasheet - SRB301LC 24VAC/DC

Users Manual. Stroboscope. September 2014

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

EZ-LIGHT K90FDL Daylight Visible

APPLICATIONS. Automatic warehouse. Trasportation lines

Keysight 16048G/H Test Leads

VideoSplitter HDMI 4K PT

Surface Mount Multilayer Ceramic Chip Capacitors for High Frequency

Quick-disconnect cables. Adjustable mounting brackets

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

Warner Photoscanner MCS-500 Series LED Photoelectric Control

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

INTRODUCTION INSTALLATION LIGHTNING RETARDING LOOPS. Figure 1. Relay Box Antenna Connections. Relay Box Cable Connections

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Features. Typical Applications

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Instant 802.3af Gigabit Outdoor PoE Converter. Model: INS-3AF-O-G. Quick Start Guide

MaxiBridge mm Connectors. Ed Full-scale MaxiBridge 8 Pins Catalog E

Transcription:

New Products Lighted Pushbutton Switch (Square) Ultra Bright LED Type Large Square-bodied Lighted Pushbutton Switches New models added with Ultra LEDs. New models with ultra bright LEDs added to single-screen models. Previous models not changed. Line up of models in seven colors (the previous red, orange, green, and white models, and the new yellow, blue, and pure white models). Popular maintenance lock added. Refer to Safety Precautions for All Pushbutton Switches/ Indicators and Safety Precautions in the datasheet. List of Models Model Appearance J (Rectangular) 6.7 25 52 max. 2 A (Square) 6.7 25 52 max. 25 T (Round) 6.4 2 dia. 52 max. 1

Model Number Structure Model Number Legend... The model numbers used to order sets of Units are illustrated below. One set comprises the Pushbutton, Lamp, and Switch. For information on combinations, refer to Ordering Information on pages page and 4. (1) (2) () (4) (5) (6) A P J - 90 B 1 1-24A R (1) Shape of Pushbutton Symbol Shape Rectangular J A Square T Round Momentary operation: Self-resetting Alternate operation: Self-holding (2) Switch Specifications Standard Load Symbol A B C D Microload Operation Momentary Alternate SPDT Momentary Alternate DPDT Symbol Operation E Momentary SPDT G Momentary DPDT () Screen Pattern Illumination-only models Symbol Screen pattern 1 Single screen (4) Case Color Symbol Color 1 Black Light 2 gray Note: T models are available in light gray only. (5) Lighting Method Bullet Shape LED Models (J and A Models Only) Symbol 05A 12A 24A Rated voltage 5 VDC 12 VAC/ VDC 24 VAC/ VDC (6) Color of Pushbutton For LED Symbol Color R Red O Orange G Green W White Y Yellow A Blue Pure White Standard Load 250 VAC, A 0 VDC, A Microload 125 VAC, 0.1 A 0 VDC, 0.1 A Minimum applicable load 5 VDC, 1 ma LED Lamplighted Models (T Only) Rated Symbol voltage 05S 5 VDC 12S 12 VAC/ VDC 24S 24 VAC/ VDC Color of screen Symbol R Y G W O A Color Red Yellow Green White Orange Blue Pure White Color of Plate Red Yellow Green White Orange Blue White LED Red Pure Yellow Green Amber Orange Blue Pure White 2

Ordering Information Ordering as a Set... The model numbers used to order sets of Units are given in the following tables. One set comprises the Pushbutton, Lamp, and Switch. (Not all combinations are possible. Ask your OMRON representative for details.) Rectangular Models (Single Screen) (Single Screen) (1) J Contact type No. of outputs Bullet Shape LEDs 5 VDC J-90A11-05A(1) J-90A12-05A(1) J-90B11-05A(1) J-90B12-05A(1) SPDT R, O, G, W, Y, A or 12 VAC/DC J-90A11-12A(1) J-90A12-12A(1) J-90B11-12A(1) J-90B12-12A(1) Standard 24 VAC/DC J-90A11-24A(1) J-90A12-24A(1) J-90B11-24A(1) J-90B12-24A(1) Loads Bullet Shape LEDs 5 VDC J-90C11-05A(1) J-90C12-05A(1) J-90D11-05A(1) J-90D12-05A(1) DPDT R, O, G, W, Y, A or 12 VAC/DC J-90C11-12A(1) J-90C12-12A(1) J-90D11-12A(1) J-90D12-12A(1) 24 VAC/DC J-90C11-24A(1) J-90C12-24A(1) J-90D11-24A(1) J-90D12-24A(1) Bullet Shape LEDs 5 VDC J-90E11-05A(1) J-90E12-05A(1) SPDT R, O, G, W, Y, A or 12 VAC/DC J-90E11-12A(1) J-90E12-12A(1) Microloads 24 VAC/DC J-90E11-24A(1) J-90E12-24A(1) Bullet Shape LEDs 5 VDC J-90G11-05A(1) J-90G12-05A(1) DPDT R, O, G, W, Y, A or 12 VAC/DC J-90G11-12A(1) J-90G12-12A(1) 24 VAC/DC J-90G11-24A(1) J-90G12-24A(1) Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White, (Y) = Yellow, (A) = Blue, () = Pure White. Example: Red J-90A11-24A R Lighting method Operation Momentary operation (Self-resetting) Alternate operation (Self-holding) Pushbutton color symbol Case color Black Light gray Black Light gray

Ordering Information Ordering as a Set...The model numbers used to order sets of Units are given in the following tables. One set comprises the Pushbutton, Lamp, and Switch. Square Models (Single Screen) A (Single Screen) (1) Contact type Standard Loads Microloads No. of outputs SPDT DPDT SPDT DPDT Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White, (Y) = Yellow, (A) = Blue, () = Pure White. Example: Red A-90A11-24A R Lighting method Operation Momentary operation (Self-resetting) Alternate operation (Self-holding) Pushbutton color symbol Bullet Shape LEDs R, O, G, W, Y, A or Bullet Shape LEDs R, O, G, W, Y, A or Bullet Shape LEDs R, O, G, W, Y, A or Bullet Shape LEDs R, O, G, W, Y, A or Case color Black Light gray Black Light gray 5 VDC A-90A11-05A(1) A-90A12-05A(1) A-90B11-05A(1) A-90B12-05A(1) 12 VAC/DC A-90A11-12A(1) A-90A12-12A(1) A-90B11-12A(1) A-90B12-12A(1) 24 VAC/DC A-90A11-24A(1) A-90A12-24A(1) A-90B11-24A(1) A-90B12-24A(1) 5 VDC A-90C11-05A(1) A-90C12-05A(1) A-90D11-05A(1) A-90D12-05A(1) 12 VAC/DC A-90C11-12A(1) A-90C12-12A(1) A-90D11-12A(1) A-90D12-12A(1) 24 VAC/DC A-90C11-24A(1) A-90C12-24A(1) A-90D11-24A(1) A-90D12-24A(1) 5 VDC A-90E11-05A(1) A-90E12-05A(1) 12 VAC/DC A-90E11-12A(1) A-90E12-12A(1) 24 VAC/DC A-90E11-24A(1) A-90E12-24A(1) 5 VDC A-90G11-05A(1) A-90G12-05A(1) 12 VAC/DC A-90G11-12A(1) A-90G12-12A(1) 24 VAC/DC A-90G11-24A(1) A-90G12-24A(1) Round (Single Screen) T (Single Screen) (1) Contact type Standard Loads Microloads No. of outputs SPDT DPDT SPDT DPDT Lighting method LED lamp Note: Enter the desired color symbols for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White, (Y) = Yellow, (A) = Blue, () = Pure White. Example: Red T-90A12-24S R Operation Momentary operation (Self-resetting) Alternate operation (Self-holding) Case color Light gray Light gray 5 VDC T-90A12-05S(1) T-90B12-05S(1) 12 VAC/DC T-90A12-12S(1) T-90B12-12S(1) 24 VAC/DC T-90A12-24S(1) T-90B12-24S(1) 5 VDC T-90C12-05S(1) T-90D12-05S(1) 12 VAC/DC T-90C12-12S(1) T-90D12-12S(1) 24 VAC/DC T-90C12-24S(1) T-90D12-24S(1) 5 VDC T-90E12-05S(1) 12 VAC/DC T-90E12-12S(1) 24 VAC/DC T-90E12-24S(1) 5 VDC T-90G12-05S(1) 12 VAC/DC T-90G12-12S(1) 24 VAC/DC T-90G12-24S(1) Pushbutton color symbol R O G W Y A Accessories and Tools Accessories, Tools, and the replacement parts (caps only) are the same as those for the. Refer to the datasheet. Individual colored plates and legend plates are not available. 4

Specifications Approved Standard Ratings UL (File No. E41515), CSA (File No. LR45258) Standard Load: Microload: 5 A at 125 VAC A at 250 VAC 0.1 A at 125 VAC 0.1 A at 0 VDC Note: Certification has been obtained for the Switch Unit. For detailed information on individual products that have received certification, consult your supplier. CCC (GB14048.5) Standard Load: Microload: A at 250 VAC 4 A at 0 VDC 0.1 A at 125 VAC 0.1 A at 0 VDC Bullet Shape LED and LED Lamp Ratings Bullet Shape LEDs Model J/M2PJ A/M2PA Rated current Rated current Applied Rated voltage voltage Single screen Single screen 5 VDC±5% 5 VDC 40 ma 20 ma 12 VDC±5% 12 VDC 20 ma 24 VDC±5% 24 VDC 10 ma 10 ma LED Lamps Applied voltage Rated voltage Rated current 5 VDC±5% 5 VDC 12 VAC/VDC±5% 12 VDC 8 ma 24 VAC/VDC±5% 24 VDC Ratings Contact Ratings Silver Alloy Contacts (for Standard Loads) Rated voltage (V) 125 VAC 250 VAC 8 VDC 14 VDC 0 VDC 125 VDC 250 VDC Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 5 5 5 4 0.4 0.2 Note: 1. The above values are for steady-state currents. 2. Inductive load: Power factor = 0.4; time constant = 7 ms.. The lamp load has an inrush current of 10 times the steady-state current. 4. The motor load has an inrush current of 6 times the steady-state current. Standard testing condition (1) Ambient temperature: 20 ± 2 C (2) Ambient humidity: 65 ± 5%RH () Operating frequency: 20 times/min. Gold Alloy Contacts (for Microloads) Rated voltage (V) Minimum applicable load Characteristics Operating frequency 0.7 0.5 2 2 2 0.05 0.0 2 4 4 0.4 0.2 0.1 A at 0 VDC (resistive load); 0.1 A at 125 VAC (resistive load) 1 ma at 5 VDC 1. 0.8 0.05 0.0 Mechanical 120 operations/minute max. *1 Electrical 0 operations/minute max. 100 MΩ min. (at 500 VDC) Standard load 40 mω max. (initial value) Microload 100 mω max. (initial value) Between terminals of same polarity 1,000 VAC, 50/60 Hz for 1 minute *2 Between terminals of different polarity 2,000 VAC, 50/60 Hz for 1 minute Between current-carrying metal 2,000 VAC, 50/60 Hz for 1 minute part and ground Between each terminal and 2,000 VAC, 50/60 Hz for 1 minute non-current-carrying metal part Between lamp terminals 1,000 VAC, 50/60 Hz for 1 minute * 10 to 55 Hz, 1.5 mm double amplitude (1 ms max.) Malfunction Destruction 500 m/s 2 max. Malfunction 200 m/s 2 max. (1 ms max.) Momentary operation models: 1,000,000 operations min. Alternate operation models: Mechanical 200,000 operations min. (One operation consists of set and reset operations.) Electrical 100,000 operations min. Approx. 0 g NC Silver contact: 10 A max. NO Silver contact: 10 A max. Bullet Shape LEDs: 10 C to 40 C (with no icing or condensation) LED Lamps: 10 C to 50 C (with no icing or condensation) 5% to 85%RH Insulation resistance Contact resistance Dielectric strength Vibration resistance Shock resistance Life expectancy Weight Inrush current Ambient operating temperature Ambient operating humidity Ambient storage temperature 25 C to 65 C Degree of protection IP40 Electric shock protection class Class II PTI (proof tracking index) 175 Pollution degree (IEC947-5-1) *1. With alternate operation models, 60 operations/minute max. One operation cycle consists of set and reset operations. *2. 600 VAC for microloads. *. With no incandescent lamp or LED lamp mounted. 5

Specifications Operating Characteristics Operating Characteristics Model J series A series T series Momentary operation models Alternate operation models Momentary operation models Alternate operation models Momentary operation models Alternate operation models Operating force OF max. 5.88 N 6.86 N 5.88 N 6.86 N.92 N 4.90 N Releasing force RF min. 0.9 N 0.29 N 0.9 N 0.29 N 0.9 N 0.29 N Total travel TT Approx..5 mm Approx..5 mm Approx..5 mm Approx..5 mm Approx..5 mm Approx..5 mm Pretravel PT max. mm mm mm mm mm mm Lock travel alternate LTA min. --- 0.5 mm --- 0.5 mm --- 0.5 mm Nomenclature Model Structure Lighting method Bullet Shape LED Models (LED is built-in.) LED Lamp-lighted Models (LED lamp is not built-in.) Models J A T Screen patterns Single screen Single screen Single screen Example: J with Bullet Shape LED Lighting Cap (transparent) Legend plate (colored plate) Diffusion plate (translucent) LED Unit (with built-in bullet shape LEDs) Switch Block 6

Dimensions The Dimension shows 2-switch outputs. (Unit: mm) J (Rectangular) Models A (Square) Models 2.8 26.1 29.9±0.2 0.5 22 OMRON logo #110 quick connect terminal/ solder terminal OMRON logo #110 quick connect terminal/ solder terminal 25±0.1 18.9 22.9±0.2 25±0.1 19.1 19.1 22.9±0.2 2±0.1 6.7 4.6 52 max. Separator 25±0.1 6.7 4.6 52 max. Separator 52.6 52.6 T (Round) Models #110 quick connect terminal/solder terminal 22.4 28.5 dia. OMRON logo 2 dia. 24.9 dia. 6.4 4.6 52 max. 52.6 Note: The thickness of tab terminals #110 and solder terminals is 0.5 mm. Terminal Connections Bullet Shape LED Models (The terminal arrangement diagram shows a 1-switch output. Connections to terminals from the lighting block are the same for 2 outputs.) Model Rated voltage Screen pattern 5 VDC 12 VDC 24 VDC Bottom view Top view Bottom view Top view Bottom view Top view J Single screen Terminal arrangement Lighting block Terminal arrangement Lighting block Terminal arrangement Lighting block Bottom view Top view Bottom view Top view A Single screen Terminal arrangement Lighting block Terminal arrangement Lighting block 7

Dimensions LED Lamp-lighted Models (All are shown with the OMRON logo facing down. The terminal arrangements are the same as for the LED-lighted models.) Output Model Round T models (Unit: mm) Bottom view Top view SPDT Terminal arrangement Lighting block Panel Cutout (If you use a Switch Guard or Seal Cover, refer to Switch and Guard Mounting Dimensions or Seal Cover Mounting Dimensions in the datasheet.) J (Rectangular) Models Classification Mounting design Panel cutout Remarks Individual (Horizontal) 25±0.1 0.5 ±0. 2±0.1 2.5 ±0. Flange mount models Multiple (Horizontal) Individual (Vertical) Multiple (Vertical) 25±0.1 1 2 n 2n ±0.5 Mount to long plate (J-002) before use. Mount to long plate (J-002) before use. 2.5±0. 2 ±0.1 2.5±0. 25 ±0.1 2 ±0.1 1 2 n 0.5 ±0. 25n ±0.5 0.5±0. 2n 1.5±0. 25n 1.5±0. Panel cutout spacing between rows of Units: 6 min. min. Barrier mount models Individual (Horizontal) Multiple (Horizontal) Individual (Horizontal) 27 9 27 1 2 n+6±1 4 2 ±0.1 n Mount to long plate (J-002) before use. 6.4±0. 2.5±0. 2.9n+.5 ±0. 2.5 ±0. 29.4±0. 0.5 ±0. For barrier mount models, refer to Accessories in the datasheet. Panel cutout spacing between rows of Units: (Dotted line indicates the position of each barrier.) 1. 6 min. 6 min. Multiple (Vertical) 4 1 2 n Mount to long plate (J-002) before use. 26n+6 ±1 0.5 ±0. 25.9n+.5±0. Note: 1. n: Number of Units 2. Recommended panel thickness: 1 to 5 mm. Mount the panel before the Switch Guard. 4. If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. 8

Dimensions A (Square) Models Classification Mounting design Panel cutout Remarks (Unit: mm) Flange mount models Barrier mount models Individual Multiple Individual Multiple Note: 1. n: Number of Units 2. Recommended panel thickness: 1 to 5 mm. Mount the panel before the Switch Guard. 4. If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. T (Round) Models 6.4 dia. 25±0.1 2.5 ±0. 25±0.1 22.5±0. 25±0.1 1 2 n 2.5±0. 25n±0.1 27 2.5±0. 27 2 1 2 n 26n+6.5±1 25n 2.5±0. 27.8±0. 2.5 ±0. 26n+2.5±0. Panel cutout spacing between rows of Units: 6 min. min. Panel cutout spacing between rows of Units: (Dotted line indicates the position of each barrier.) 1. 6 min. 6 min. +0.2 11.8R 0 29±0. dia. 4 min. Note: 1. Recommended panel thickness: 1 to 5 mm 2. If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating. 9

Safety Precautions Refer to Safety Precautions for all Pushbutton Switches/Indicators for common precautions. Read the Safety Precautions in the datasheet. For technical information and FAQs, refer to Technical Support on the OMRON Industrial Automation website (http://www.ia.omron.com). 10

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.

OMRON Corporation Industrial Automation Company Tokyo, JAPAN Contact: www.ia.omron.com Authorized Distributor: Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-212 JD Hoofddorp The Netherlands Tel: (1)256-81-00/Fax: (1)256-81-88 OMRON ASIA PACIFIC PTE. LTD. No. 48A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 685-011/Fax: (65) 685-2711 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 6017-502 U.S.A. Tel: (1) 847-84-7900/Fax: (1) 847-84-7787 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-507-2222/Fax: (86) 21-507-2200 OMRON Corporation 201 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM 2_0119 Printed in Japan Cat. No. A229-E1-01 091 (091)