FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

Similar documents
Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

Modular Lube Lubrication Systems System Controls

Vortex Mixers. Mini Vortex Mixers Heavy-Duty Vortex Mixers Microplate Vortex Mixers Multi-Tube Vortex Mixers. Asia Pacific

Bartels Micropumps. ( ) Rev. 2.8

Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer

Label Applicator HERMA 400

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Operation Manual for the Refractive Index detector VE-3580

Absolute Encoders Multiturn

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

Programmable High Resolution LCD Switches

TABLE OF CONTENTS. Instructions:

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Single Point Flow Monitor SW118 SW119

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Routing Swichers 248

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

APPLICATIONS. Automatic warehouse. Trasportation lines

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Simple all-in-one design style with front stereo speakers and natural ventilation system

ROTARY EVAPORATOR BOECO ROTARY EVAPORATOR RVO 400 SD

TUC: Universal thermostat

HSR-1 Digital Surveillance Recorder Preliminary

Performance. Reliability. Productivity. Automated Flash Chromatography Systems

Solid-State Digital Timer

Digital Real Time Recording VCR

SmartSwitch TM. Wide View Compact LCD 64 x 32 Pushbutton DISTINCTIVE CHARACTERISTICS PART NUMBER & DESCRIPTION

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

DTL-4800P. Digital Real Time Recording VCR

IMPAC Infrared Thermometers

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Functions and Features: Prime key for fast filling and emptying.

Capacitance Limit Detection nivotester FTC 420/421/422

4.1 PRESSURE ADJUSTMENT Adjustment of Pressure Detector Circuit Adjustment of Pressure Indication...2

istep STEPPER MOTOR PUMP

MB5 Multibeam Activity Monitor

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

2.9 Sigma/ 2 Plunger Metering Pumps

Selection matrix for electronic pressure switches

Compact Size Perfect for rack mount router and other applications with space limitations.

SM-10 SAT Level Meter User s Manual

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

THE SKALAR CONTINUOUS FLOW ANALYZERS COMPONENTS AND ACCESSORIES BOOKLET

SmartMix Manual V5350A

SmartSwitch TM. Wide View LCD 36 x 24 Pushbutton DISTINCTIVE CHARACTERISTICS PART NUMBER & DESCRIPTION

LEVIFLOW Ultrasonic Technology Single-Use High Precision Flowmeters

DOME OPTIC SPLICE CLOSURE

The measurements are stored in non-volatile memory, which retains data even when the power down.

Liquid Level Sensor Type AKS 4100U

SIMATRIX NEO V2 Modular Video Matrix

EN - English Washington Street Melrose, MA Phone Toll Free Revision 4 20/06/17

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Portable Filter Cart Type SPFC

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

eblot L1 Protein Transfer System Fast Wet Transfer System for Mini Gels

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DIGITAL STROBOSCOPE OPERATION MANUAL. Model : DT-2239A

Control Unit CU 2.1 User Manual V6850A HPLC

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Liquid Chromatography- Mass Spectrometer Manual

General Specifications

extra Liquid Handling Precision Laboratory ConsumablesV 5 : Proline Plus Mechanical Pipettes Ask about our Pettecheck pipette service & calibration!

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

GFT Channel Slave Generator

FAST MOBILITY PARTICLE SIZER SPECTROMETER MODEL 3091

Mechanical flow switch for On/Off control

Sigma 4-16S Sigma 4-16KS Sigma 4-16KHS

istep STEPPER MOTOR PUMP

System Interface Unit SIU-100/100T

Absolute encoders multiturn

16-CH Color Full Duplex Multiplexer Instruction Manual

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

SmartSwitch. Wide View LCD 64 x 32 Pushbuttons & Display DISTINCTIVE CHARACTERISTICS

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

General Specifications

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

LEVIFLOW Ultrasonic Technology Single-Use High Precision Flowmeters

Advantech Proudly Presents Professional Monitor Series

Optical Cryostat - Omniplex TM

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Pulse Counters, electromechanical

Advanced Test Equipment Rentals ATEC (2832)

VMA ACTIVE MATRIX TFT COLOR LCD MONITOR OWNER S MANUAL INSTALLATION GUIDE

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Users Manual FWI HiDef Sync Stripper

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Part 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories

ET-YFB100G S P E C F I L E. Digital Interface Box. As of December Specifications and appearance are subject to change without notice.

800 Displaying Series Flowmeter

Junior Max (JR Max ) Controller

Tube Rotator. User Guide. Version 1.2

Transcription:

FRACTION COLLECTOR Microcomputer Controlled CHF122SC

From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model CHF122SC has a wide range of uses. The CHF122SC is a fraction collector with increased reliability, employs an X-Y movement mechanism based on long years of technological accumulation, a new vertical movement apparatus and a large display screen for easier use than ever. The CHF122SC holds up to vessels, and can handle a variety of vessel diameters and lengths. With its numerous fraction functions, the CHF122SC boasts a wide range of applications. Features Easier operation with a large display screen With 9 operation keys and a large 40 characters x 8 row display screen, it is easier than ever to input programming and parameter settings. The graph display of chromatography signals makes it easy to determine the status of fraction collection. Main body and standard rack Reliable construction The water-sensitive operation panel as well as the mechanical and electronic parts are placed behind the test tube rack to protect against water droplets for a practical, long-lasting design. Supports different sized collection vessels The vertical dial allows 70 mm of movement to adjust the dropper nozzle position to the test tube length (105 ~ 180mm). The standard test tube rack will hold tubes with a diameter of 12 ~15mm (maximum of 18.1 mm with the standard rack holder removed). Large volume vessels can be set when the rack lid is removed. For collecting big bottles Quick nozzle movement with higher resolution A sturdy frame and higher resolution stepping motor are used. The nozzle moves accurately to the set position, from tube to tube in 0.1 seconds. Unneeded constituents drained Waste constituents are drained out so test tubes are not unnecessarily contaminated. Safe, chemically resistant material The exterior of the unit is made of flame retardant ABS plastic, and the test tube rack and drain are made of chemically resistant polypropylene. Simple up-and-down movement Drain Up/Down knob

Loaded with Unique Collection Functions Simple mode: Collect by time, drops, volume or signal. Peak Mode: Specify up to a maximum of 10 peaks for identification. Peak determination may be made using a combination of absolute value and slope angle. Example of slope angle setting As shown in the graph Example of peak absolute value setting Set the at right, because of base line drift, only three peaks are percent value using an input signal full scale of 100%. identified at 1, 2/3 and 4/5/6/7/8 by absolute value setting. Peaks above the set absolute value are identified. However, by using a slope setting, all 8 peaks are identified. Window mode A maximum of 16 windows (time ranges) may be set so that peaks are identified and fraction collection occurs only within each window. By setting the monitor time, non-peaks may also be collected in the test tubes. Window mode setting, example 1 Window 1 is set between 2min00sec and 2min32sec at request time of 12sec. Window 2 is set between 3min32sec and 5min00sec at 8 sec request time. Main settings Wait time: [40 sec] Non-window monitor time: [0 sec] Window settings 01: Start [2min00sec] ~ End [2min32sec] Request time [12 sec] 02: Start [3min32sec] ~ End [5min00sec] Request time [8 sec] Peak parameters Absolute value: [0%], Slope angle: [0mv/min] Response: [*HIGH], Delay time: [0 sec] Window mode setting, example 2 (peak identification) Peaks within the windows are identified. Fraction collection is set at 12 seconds during peaks for window 1. For non-peaks, the monitor time interval is 8 seconds. Main settings Wait time: [40 sec] Window settings Non-window monitor time: [0 sec] 01: Start [2min00sec] ~ End [2min32sec] Request time [12 sec] Monitor [08 sec] 02: Start [3min32sec] ~ End [5min00sec] Request time [8 sec] Monitor [24 sec] Peak parameters Absolute value: [40%] Slope angle: [20 mv/min] Response: [*HIGH] Delay time: [0 sec] Wait Monitor Request Vessel # Wait Monitor Request Vessel # Manual mode Collect fractions while watching the chromatography signals displayed on the screen. A fraction may be reviewed under playback mode. Setting Example = Sampling Mode Sampling mode Collect fractions for a set interval during a set period. Multiple collections may be set per test tube. In the setting example shown on the right, wait time is 5 minutes, each test tube has 2 repeats of 5 minutes intervals every 15 minutes.

Fraction result display Multiple sample functions After a fraction collection has completed, the next fraction sampling begins at the next test tube or after skipping one tube. Synchronize the chromatogram and collection using the time delay function Because of the distance from the UV absorption detector, refractometer or other instruments to the fraction collector dispense nozzle, there is a delay from the point of graphing until the sample is collected in the tube. By inputting the lag time, the collected sample can be set to accurately conform to the record (chromatogram). Peak signal graph display Verify the fraction collection results by looking at the graph The results of up to 500 events can be displayed. Chromatography signals are displayed in peak, window and manual modes. Operate using a computer Using a computer, the parameter settings for each mode as well as starting, ending, pausing and advancing can be controlled. By loading up to 500 fraction results into the computer, the operation history of the equipment and test results can be easily verified. Sample liquid chromatography system set-up After inserting the sample into the top of the column, the elute separates out. While characteristics are measured with detectors, the separated substances are eluted into the fraction collectors. Example of sampling system set-up A small amount is sampled at a fixed interval, and inserted into the fraction collectors.

CHF122SC Accessories CH000760 CH000754 CH000770 CH000780 CH000790 Optional racks and rack accessories Non -standard test tube racks available. 96 well microplate Rack Holding qty Vessels 4 CH000754 96 well microplate 27.5 mm vial Rack CH000760 27.5 mm (OD) X 57 mm scintillation vials 56 16.5 mm vial Rack CH000770 CH000780 16.5 mm (OD) x 54 mm scintillation vials 15 18.1 mm (OD) x 105 18 mm (L) test tubes CH000790 12 mm (OD) x 105 180 mm (L) test tubes Test tube Rack (without holder) for 155 mm OD and up test tube Test tube Rack (with 12 mm OD holder) for 12 mm OD test tube * Microplates, scintillation vials and test tubes are not included with racks. 12 mm holder CH000730 Rack middle plate CH000740 Specifications CH000730 Test Tube rack (12 mm OD holder), holds 30 12-mm test tubes Place in the test tube rack (standard, 15 mm OD or larger, or 12 mm OD) to allow use of 35~105 (L) mm tubes. CH000740 Eppendorf tube adapter Use to adapt the standard test tube rack to Eppendorf tubes CH000800 Max. no. of fractions Useable test tubes 1.5 ml (40 mm high, 11 mm body circumference) Stainless steel Material Dimensions CH000800 275 (w) x 248 (d) x 115 (h) mm * Test tube rack and Eppendorf tubes are not included with the Eppendorf tube adapter. Preparative Options Prep. Funnel (CH000160) and Prep. Funnel Rack (CH000845) allow the end user to collect fractions in large volume containers. Specifications CH000160 Prep. Funnel CH000160 30 fraction funnels in each CH000160 Prep. Funnel Rack CH000845 Holds up to 3 CH000160s (3x30 pos.) Prep. Tygon Tubing Prep. Mobile Cart CH000180US TYGON TUBE (6.35X9.52mm) X 5M) CH000115 Cut out hole on the Top table 3-Way diverter valve Prevent the sample from spillage out from the tubes while the nozzle is in transit. Also, use the included seal adapter to use the valve as a stop valve. May be set to drain to prevent residual sample in the valve from the previous peak from being mixed in with the next fraction. The 3-way valve CH000710 has a low residual volume to decrease contamination. CH000700 CH000710 3-Way diverter valve Inlet pressure Connector Material CH000700 300 kpa (40.5psi) IN Residual volume (µl) Power consumption NC NO 26 66 66 Low residual 3-Way valve CH000710 200 kpa (29psi) Teflon, Diflon (PCTFE) 14 7 7 2.2 VA max. * The CH000710 has a flow volume approximately 40% less than the CH000700.

Specifications CHF122SC Test tube quantity tubes (12 ~ 18 mm OD x 105 ~ 180 mm L) (remove tube holders for larger than 15 mm OD) Operation modes Collection methods Nozzle shift time Simple, Peak, Window, Manual, Sampling By Time, Drop count, Drop volume, Signal 0.1 sec (tube center to center) Modes of Operation Simple mode Time: 99 min 59 sec / tube max. Drop: 9999 count / tube max. Volume: 999.9 ml / tube max. Signal: 9999 count / tube max. Vessel parameter specifications Rack selection Standard test tube Rack (CH000670) Eppendorf tube Rack (CH000800) Scintillation vial (16.5mm) Rack (CH000770) Scintillation vial (27.5mm) Rack (CH000760) Microtiter plate (96well x4) Rack (CH000754) Prep. Funnel (CH000160) Rack (CH000845) Bottle position arrangement Bottle arrangement Matrix arrangement: 2 patterns Arbitrary arrangement: 1 pattern Regular arrangement Arbitrary arrangement Max. 12 rows x 15 columns ( pos. max.) Max. 100 positions Peak mode: End time: 999 min max. Request time: 99 min 59 sec / tube max. Monitor time: 99 min 59 sec / tube max. Fraction peak: Up to 10 out of 99 peaks Peak discrimination: Absolute value 100% max. Slope 99.99mV/min or 9.999mV/min max. Signal response: Chromoto. signal sampling High: 0.5 sec Low: 3 sec External signals Event marker Chromato, signal input External start input External end input 2 contact point output circuits: 1. Pulse signals 2. Level signals 10 mv or 1 V full scale ON START ON END Window mode Non-window monitor: 99 min 59 sec max. No. of windows: 16 max. Start/end time: 999 min 59 sec max. Request/Monitor time: 99 min 59 sec / tube max. Peak specifications: Same as in peak mode Manual mode Learning response: Chromato. signal display High: 0.5 sec Low: 3 sec. Playback: Replay results of learning Sampling mode Interval: 99 min 59 sec max. Collection time: 99 min 59 sec max. Collection volume: 999.9 ml max. No. of repeats: 99 max. Common Wait time: 999 min 0 sec max. parameters for Simple, Peak, Window and Sampling modes Delay time: 9 min 59 sec max. for Peak, Window and Manual modes External count input Serial interface ON COUNT RS-232C (9-pin connector) Accessories Test tube rack CH000670 (1) Drain (1) Dust cover (1) I/O terminal connector (1) Sample tubing: Teflon 2 mm OD x 1 mm ID x 1 M (1) Drain tubing: Silicon 8 mm OD x 5 mm ID x 0.5 M (1) Tube Suspender (2) Power cord (1) Installation & Operation Manual (1) General electrical specifications Clock Quartz oscillation Operation Display 40 characters x 8 rows (LCD w/backlight) Multi-sample: Possible in Simple, Peak and Window modes. Equipment parameter specifications Volume collection Collection time (min) = Flow volume (ml) / flow rate (ml/min) Parameter memory Temperature range Power Battery back-up 2 ~ 40 C ( 35 ~104 F) AC 100 V, 115 V, 240 V, 0.23 A max. Multi-sample Skip one vessel or continuous (Non-skip) External dimensions 286 (w) x 387 (d) x 335 (h) mm Marker (2) Power failure ON after operation (assembled with I/O extension unit, pumps stops after operation) or OFF Display On or Off RS-2323C Baud rates 0, 2400, 4800 Characters: 8-bit, Parity: None, Stop: 2-bit Weight Approx. 7 kg (15.4 lbs) Replacement items Material/specs Test Tube rack CH000670 Polypropylene Drain CH000680 Polypropylene Dust Cover CH000691 PVC Tube Support (12~15mm) CH000720 for CH000670, (30 holders/pk)