PROKNX. Bleu Comm Azur Industriestr Ainring

Similar documents
Tebis application software

Tebis application software

Series Touch Panel. EX1S (Dimming) EX1 (Dimming) EX2 (CT) Wireless driver. Wireless remote. Wireless driver

(RGBW)

TUPEX MOWI Wireless light control

application software

application software

KNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136

Appendix 13 Phillips Hue

TF5 / TF3 / TF1 DIGITAL MIXING CONSOLE. TF StageMix User's Guide

Dimming actuators GDA-4K KNX GDA-8K KNX

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Rako App Guide. A Rako lighting system can be controlled by the App if the system meets the following requirements:

PART 1: HARDWARE. Author: Vandermeerschen M. Version

Instruction manual. DALI Gateway art Installation manual

Product Manual ise smart connect KNX Hue Order No Valid for application software v4.2 and firmware version v4.0

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

KNX 1-10V dimmer 4 channels

LS9 StageMix V6 User Guide

TABLE OF CONTENTS. 2 SGM Light Technology 23/08/1999 Ver. 2.00

OLED THE PERFECT HIGH-RESOLUTION DISPLAY

KNX Dimmer RGBW - User Manual

General FAQs Status as of: 22/10/2018

LED Lighting Control and Interface

Control4 Philips Hue Lighting Driver Version 8

CL StageMix V6 User Guide

CONTENTS Page 1.0 System Requirements Wi-Fi Settings Getting Started Mixer Window... 14

QL StageMix V8 User Guide

Webinar Competence Center Europe Building Automation. Ilija Zivadinovic, Martin Wichary, Juergen Schilder, Thorsten Reibel, Stefan Grosse

Package Contents. LED Protocols Supported. Safety Information. Physical Dimensions

Casambi App User Guide

Product documentation

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

NEW. Simply smart. Simply LUXOR. The LUXORliving smart home system.

Gamma instabus. Technical product information

BoxIO User Manual Updated Applies to BoxIO Firmware Version 1.51 IP Remote Utility Version 1.0

Tebis TX100 Configurator

The GTP-32 Control Processor helps you solve equipment interface, control and monitoring problems, quickly and easily

SDI-INSERTER SDI-3G-7xx

BLE TECHNOLOGY. (Bluetooth Low Energy) arcluce.it

EasyAir Philips Field Apps User Manual. May 2018

KNX Technical Reference Manual Busch-EnergyControl

Class Notes for Cite While You Write Basics. EndNote Training

RELEASE NOTES. Introduction. Supported Devices. Mackie Master Fader App V4.5.1 October 2016

V pro8 QUICK START GUIDE

RS-232C, LAN and Infrared Remote Control Guide FOR MODELS: Version 1.4. Contents

Professional-Practice

Philips LightMaster. KNX Timeclock Installation and Operation Manual

Douglas Lighting Controls Bluetooth Commissioning and Room Control App BT-APP

Owner's Manual. TOUCH SCREEN CONTROLLER for Air Conditioning Control System. Model BMS-CT5120UL. English

PRODUCT MANUAL. DMX BOSS Wi-Fi Controller. Product Description

INSTALLATION & USER GUIDE

Don t let Potential Customers pass you by!

2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. KNX LED dimmer Constant voltage 4gang with power adaptor 6155/40-500

AV Foundry VideoForge HDMI Digital Video Generator Quick Start Guide

PRODUCT MANUAL. Chroma Flow PRO RGB LED Controller. and Receiver. Product Description. Main Functions: This manual reviews: Receiver.

Product Manual. ABB i-bus EIB / KNX Switch/Dim Actuators SD/S. Intelligent Installation Systems ABB

Remote Application Update for the RCM33xx

Video Extender DS128 DSRXL. Instruction Manual. 8-Port Cat5 VGA Digital Signage Broadcaster with RS232 and Audio

In this paper, the issues and opportunities involved in using a PDA for a universal remote

8K120 Projection Application

Getting started with

SQTR-2M ADS-B Squitter Generator

MT300 Pico Broadcaster

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Signalist SC1. DCC signal controller user manual Covers configuration for UK signals

MAGIC THipPro. Signalling and Control with. Configuration Guide. using the example of a LAWO crystal mixing console. Version: March 26 th, 2018

Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices

2G Video Wall Guide Just Add Power HD over IP Page1 2G VIDEO WALL GUIDE. Revised

Intevi Digital Television. IDT Product Brochure The convergence of IPTV and Digital Signage...

PANEL VIEW. Control Panel. Enlarged Panel Illustration DELEGATION SECTION PRIMARY CROSSPOINT BUS SECTION EFFECT TRANSITION SECTION

User Guide. MonitorMix User Guide 1

IoT Controller. Connecting the world of digital objects and services with KNX. IoT

Q Light Controller+ Positions and EFX explained

Globalmediapro SMR-650

automate your world from

SMART Blue Smart Switch

AxumVideo 0 intro. Now that you have connected the different AXUM system parts, you are ready to configure the system according to your own needs.

feno before light and beyond

TERMINOLOGY INDEX. DME Down Stream Keyer (DSK) Drop Shadow. A/B Roll Edit Animation Effects Anti-Alias Auto Transition

Hotel Ballroom. Figure 1 above, graphically details this scenario. 8:1 1 of 5. We ve got it under control

Clipsal and C-Bus are registered trademarks of Clipsal Australia Pty Ltd.

BTW03 DESIGN CONSIDERATIONS IN USING AS A BACKPLANE TEST BUS International Test Conference. Pete Collins

PRODUCT MANUAL LUMENTO X3 LED. LED Controller ZN1DI-RGBX3. Program Version: 1.0 Manual Edition: a

Product Manual. ABB i-bus KNX DALI Gateway DG/S

3G TILING TRANSMITTER MANUAL

DLP600M 6+1 Relay Module for Heating and Cooling Plants

S I N E V I B E S FRACTION AUDIO SLICING WORKSTATION

Broadcast Graphics ACSR BG400 Webinar Table Of Content

Getting started with

DLA-HD350 / DLA-HD750 DLA-HD550 / DLA-HD950 DLA-HD990 DLA-RS10 / DLA-RS20 DLA-RS15 / DLA-RS25 DLA-RS35. RS-232C and Infrared Remote Control Guide

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

Turnout Decoder TD Maxi. User Manual - version 0.1.6

VSP 198CVS Quick Start

All the energy of your home, in an App!

2-output DALI controller

University of Utah Marriott Library Audio Visual Systems User s Guide

Users Manual Firmware 1.06 October 12, 2016

SAT IF distribution system

Bringing an all-in-one solution to IoT prototype developers

Transcription:

PROKNX Philips Pronto Professional TSU9600, TSU9800 KNX interface software Version 3.x Bleu Comm Azur Industriestr. 9 83404 Ainring www.bleucommazur.com 14.03.2009

CONTENT CONTENT... 2 VERSION CONTROL... 3 INTRODUCTION... 3 SYSTEM REQUIREMENTS... 3 FUNCTIONALITIES... 4 SIMPLE CIRCUIT CONTROL... 4 CONFIGURATION OF SIMPLE CIRCUIT CONTROL... 4 FLOOR AND SCENE CONTROL... 6 USING FLOOR AND SCENE CONTROL... 7 CONFIGURATION OF ON/OFF CIRCUITS... 8 CONFIGURATION OF SCENES... 10 CONFIGURATION OF SCENE ADJUST PAGES ROOM_SC... 12 ABOUT... 14 2

Version Control This document explains the software of PROKNX V 3.x Differences to Version 1.x: - In simple circuit control all circuits are polled during the Pronto page is activated. Differences to Version 1.x and Version 2.x: - Version 3.x can be used with the actual Pronto Edit Professional 2 Programming Software. Introduction The software PROKNX is a Pronto Script software tool for 2 way communication with the KNX Bus system. It allows to control lighting management functions like: - On / Off switching - Dimming control - Scene switching - Scene programming In all of the cases, the user has the loop back information of the actual state of the lighting circuit or scene selection. There are add on s for this software that control: - Motorized shading systems - Heating, cooling and ventilation - Specialized interface software for other KNX products System requirements The system is based on TCP/IP connection. All you need is - Pronto Edit Professional V 2.1.18 or higher - Pronto Professional TSU9600 Firmware 4.0.17 or higher - Wireless router - IP gateway PROKNX, specially designed for this application. In case of questions how to get the newest firmware, programming software or PROKNX gateway, please have a look to our website www.proknx.com 3

Functionalities The Pronto configuration file will have the following structure: There are two possible basic functions implemented, that can be used ether separated or together: - Simple circuit control - Floor and scene control For the first functionality the device room without scene will be used, the second one uses both devices first floor and room nr 0 with scene. Simple circuit control The device room without scene is an example for simple circuit control. One device room without scene may control up to 7 on/off circuits and 7 dimmed circuits. You may copy this device for more than one room. If you intend to control your lights in simply using on/off switches and/or dimming sliders than this device will be sufficient to merge with your application. Configuration of simple circuit control Your jump to control a room has to be assigned as page jump to room_no_sc. You can copy up to seven sliders and seven switches into the page room_no_sc. Please use the to_copy page for the original sliders and buttons. IMPORTANT: You have to respect the order of the original elements, as this is part of the assignment. 4

The graphical elements are combined in a group, so an easy copy is possible. You don t have to ungroup these elements, as the labels will be assigned according to the widgets of the PARAMETER page. The to_copy page looks like this. Don t change this page. First dimming slider First on/off switch 7th dimming slider 7th on/off switch Once you have defined the look of your room_no_sc page, please open the PARAMETER page: Please adjust: IP address IP address of the PROKNX Gateway. This address has to be the same as you may adjust in the Parameters of the gateway in the ETS software. port_nr The standard value for the gate is 12004 name dimm. lamp Register n dimmval The slider will be labelled with this name Address of the first Register dimming value that has to be assigned to the address group of the dimming actor (1 Byte value). The registers for the dimmed circuits have to be consecutive! Quantity Quantity of dimmed circuits (0 7) 5

name swit. lamp register n ON/OFF Quantity The On/Off button will be labelled with this name Address of the first register that has to be assigned to the address group of the switching actor (1 Bit). The registers for the switched circuits have to be consecutive! Quantity of the switched circuits (0 7) If you have adjusted these values, it should be possible to command the defined circuits. Notes: - The slider may be adjusted also in tapping directly on the desired position. - If you want to switch and dimm a circuit, you may use one register n dimmval and one register n ON/OFF for the same circuit but with two address groupes. - In version 2.x this page will be automatically updated when the state of the light will be changed by a KNX switch. Floor and scene control A little more complex application will allow an overview in terms of a graphical layout of a certain area of your home. This functionality will allow you to: - switch up to 19 rooms on/off - switch up to 3 scenes (+ off scene) for up to 9 additional rooms - adjust scenes with up to 7 on/off circuits and up to 7 dimmed circuits for each of the 9 rooms 6

Using floor and scene control The designed graphical user interface is very simple to use: - This screen is updated automatically every second - In tapping on the light bubbles the selected room will be switched on/off - There is a shadow widget, that becomes visible, when the light is turned off - Firmkey 1 will turn off all lights - If you have more than one circuit in a room, you may use scenes - The preselection of the scene is done by the Firmkeys 2, 3 and 4 - If you tap on the scene bubble, the preselected scene will be switched - If you stay longer than 2 seconds on the scene bubble, the page room_sc will open Scene adjust page: 7

With this page you may change and / or store the scenes of the room. To change the scene without storing the changements, just enter Return (Firmkey5). To store a changed scene, you have to preselect the scenename first (Firmkey2, 3 or 4), and then enter Store (Firmkey1). The very big advantage of this configuration is, that the scene adjustments are stored directly in the KNX actors. That means, you can recall a scene also by pushing a KNXswitch! Configuration of On/Off circuits The biggest work in configuring this application will be to design the area and the necessary overlay widgets, that will darken the rooms. We can recommend some professional designing tools like Corel Paint Shop Pro Photo X2. Once you have designed the floor layout, you have to tag the shadow - widgets (panels) : Next step will be to copy the lighting bubbles (buttons) and define different numbers from 0 to 18 for the rooms without scenes (with only one circuit): 8

To define, which lighting bubble corresponds to which shadow widget you have to use the PARAMETERS page: Please adjust: IP address IP address of the PROKNX Gateway. This address has to be the same as you may adjust in the Parameters of the gateway in the ETS software. port_nr The standard value for the gate is 12004 Reg of room[0] Widget name shadow Quantity Address of the first register of all on/off lightings. This address will be assigned for Room Nr. 0! All other registers have to follow for the next rooms consecutively! tag of the panel for the shadow widget (ProntoScript Name) that is corresponding to the room number in the Lighting bubble. Quantity of the switched circuits (1 19) 9

Configuration of scenes Similar to the configuration of the On/Off circuits you have to tag the shadow - widgets (panels). Next step will be also to copy the scene lighting bubbles (buttons) and define different numbers from 0 to 8 for the rooms with scenes (with more than one circuit): In addition to the scene lighting bubbles, there is another panel to be copied just below of it, that shows the name of the actual scene in work. (It is labelled nc.) You have to tag this panel in order to reference it. Please use the same name as you will define it in the SCENE_PARAMETERS page with the prefix SC_ : 10

To define, which lighting bubble corresponds to which shadow widget you have to use the SCENE_PARAMETERS page: Please adjust: Reg room[0] Widget name shadow KNX scene nr OFF KNX scene nr 1..3 Address of the first register of all scene definition registers. This address will be assigned for Room Nr. 0! All other registers have to follow for the next rooms consecutively! (1 Byte values) tag of the panel for the shadow widget (ProntoScript Name) that is corresponding to the room number in the Lighting bubble. Scene number that is used for the OFF scene. Please define in the ETS Software, that this scene number will turn off all lightings. Scene numbers, that are used for three scenes. The KNX scene numbers will be written into the register reg room that has to be assigned to the address group with the Szenennebenstelle. Quantity of rooms with scene definition (1 9) Quantity sc_name Scene name that will be labelled to the Firmkeys 2, 3 and 4 Room Nr IMPORTANT: Please define for this button an action with a jump to the room_sc pages that allows scene adjustments. If you use more than one room_sc page, please copy the whole room with scene device and not only the page! 11

Configuration of scene adjust pages room_sc This section is very similar to the configuration of simple circuit control. You can copy up to seven sliders and seven switches into this page. Please use the to_copy page for the original sliders and buttons. IMPORTANT: You have to respect the order of the original elements, as this is part of the assignment. The graphical elements are combined in a group, so an easy copy is possible. You don t have to ungroup these element, as the label will be assigned with the PARAMETER page. The to_copy page looks like this. Don t change this page. First dimming slider First on/off switch 7th dimming slider 7th on/off switch Once you have defined the look of your room_no_sc page, please open the PARAMETER page: 12

Please adjust: IP address IP address of the PROKNX Gateway. This address has to be the same as you may adjust in the Parameters of the gateway in the ETS software. port_nr The standard value for the gate is 12004 name dimm. lamp register n dimmval The slider will be labelled with this name Address of the first Register dimming value that has to be assigned to the address group of the dimming actor (1 Byte value). The registers for the dimmed circuits have to be consecutive! Quantity Quantity of dimmed circuits (0 7) name swit. lamp The On/Off button will be labelled with this name register n ON/OFF Address of the first register that has to be assigned to the address group of the switching actor (1 Bit). The registers for the switched circuits have to be consecutive! Quantity Quantity of the switched circuits (0 7) sc_reg Address of the register of scene definition for this room (1 Byte value) sc_val Insert scene numbers, as you have defined them in the SCENE_PARAMETERS page for this room sc_name Scene name that will be labelled to the Firmkeys 2, 3 and 4 If you have adjusted these values, it should be possible to command the defined circuits. Note: - The slider may be adjusted also in tapping directly on the desired position. 13

About PROKNX for the Philips TSU9600 or TSU9800 Christian Kiefel Copyright 2008-2009 All right reserved This work may be used in whole or part for commercial or non-commercial use if it is distributed with the PROKNX IP Gateway. The Gateway may be ordered directly through our website www.proknx.com. Redistribution of the software or the documentation without the Gateway is prohibited and requests for same should be sent to the author. 14