collezione medea Pietre di giorno, lampade di notte. Stones at day, lamps at night. Faretti LED da incasso per interni ed esterni Recessed LED lamps for indoor and outdoor Prodotto artigianale italiano Italian handcraft product
specifiche tecniche technical specifications
34 specifiche tecniche technical specifications colorazioni colours c002 c010 c016 c017 c018 c019 c023 c024 c025 c026 REALISMO ARTIGIANALE I colori indicati nel presente catalogo sono approssimativi. Ogni lampada Medea è artigianale e riproduce la naturale diversità dei materiali cui si riferisce. Per questo motivo, quando applicato su due o più lampade, uno stesso colore risulterà simile ma mai identico. handcrafted REALISM The colours showned in this catalogue are approximative. Each Medea lamp is artisanal and reproduces the natural diversity of the referred materials. For this reason, when applied on two or more lamps of the same model, the same colour will be similar bur never identical. tonalità ed intensità di luce A seconda della colorazione scelta, la luce emessa potrà avere una tonalità più calda o più fredda ed una intensità maggiore o inferiore. light hues and brightness Depending on the selected colour, the emitted light should have a warmer or colder hue and an higher or a lower intensity. colori personalizzati Se i colori standard non sono sufficienti per la migliore continuità cromatica, è possibile richiedere le luci Medea con colore personalizzato. Contattaci per saperne di più! customized colours If standard colours are not enough for the best chromatic continuity, it is possible to require Medea lamps with a customized colour. Contact us to learn more!
technical specifications specifiche tecniche 35 indicazioni per la posa laying information Posa a terra Laying on ground Incasso per pavimentazioni Recessed lighting for pavements Incasso per pareti Recessed lighting for walls L installazione ad incasso permette di raggiungere il massimo effetto integrativo. Le lampade Medea possono essere aggiunte come i normali faretti da incasso in pavimentazioni, pareti e soffitti ma il punto luce risulterà indistinguibile rispetto agli elementi non luminosi. The recessed installation allows to reach the higher integrative effect. Medea lights can be added like common recessed lamps to pavements, floorings, walls and ceilings but the spotlight will be indistinguishable compared to the non-lighting elements. 1 6 4 3 2 5 7 Didascalia schema 1 Lampada Medea 2 Comuni elementi per pavimenti o rivestimenti 3 Collante, sabbia o malta 4 Cavo elettrico 5 Supporto ( terra, pavimentazione, parete) 6 Canaletta per il cavo elettrico 7 Terreno scheme caption 1 Medea lamp 2 Elements for claddings, floorings and pavements 3 Adhesive, sand or mortar 4 Electric cable 5 Support ( ground, floor, wall) 6 Pipe for electric cable 7 Terrain
technical specifications specifiche tecniche 37 technical data sheet tech data weight (kg) dimensions (cm) enclosing material WORKING TEMPERATURE light emission at 100 cm distance Epoxy resin TENSION (V) 12 current (A) nominal power (W) POWER SOURCE light source anode cathode CO2 emissions CONTINUOUS USE DURATION (24/24) OPTICS Light INFRARED, ULTRAVIOLET Lumen 60 (maximum reachable) Absent ELECTRIC FIELD AT 15 CM V/m 2,69/3,51 photobiological risk IEC/EN 62471 FLAMMABILITY UL94 Photocatalysis (SELF CLEANING, DEPOLLUTING) -40 C / +85 C LED P-N junction Subdivided 50.000 hours Filtered MAGNETIC FIELD AT 15 CM µt 0,06 PROTECTION AGAINST ELECTROCUTION Class (III) None UNI EN60529 - PROTECTION IP 68 +++ MAXIMUM STATIC LOAD marking Shades are always approximative: a same color used on two lamps will have a similar hue, but never identical. HB Tio2 + polymers ELECTRIC CABLE FROR 2 0,5 450/750V colours DC Subdivided No Diffusive 5.000,00 Kg CE other features Non-toxic and recyclable Excellent resistance to strong acids and bases Solvent resistant Waterproof Electrical insulator Long service life Thermal retarder Don t drill the lamp Driveway and walkable paving Very low energy consumption installation The fixed installation is suitable for interiors, exteriors, driveways and submerged in water. Lamps can be sticked to the wall or floor like any building materials with a common adhesive, mortar or sand. The cable must be placed according to technical specifications provided by the manufacturer. cable Brown cable: negative White cable: positive For fixed and mobile installations indoor and outdoor. They can be installed on bridges, pipes, conduits, and similar systems. If installed in a different way, the cable should be properly protected. In any case, the properties of the cable are independent from those of the lamp.
technical specifications specifiche tecniche 39 diagrams for installers Important: data of electric current (Ampere), used in the following diagrams, are for illustrative purposes only. The system has to be design by professionals and according to the technical data sheets of each single model. Medea Lamp Power source DC Switch EXAMPLE 1 / Diagram of 8 Medea lamps connected in parallel Amount of lamps 8 Connection Parallel Lamp current V 12 / A0,25 Power source calculus A0,25 8 = A2 Power source DC V12 / A2 EXAMPLE 2 / Diagram of 8 Medea lamps connected in series Amount of lamps 8 Connection Series Lamp current V 12 / A0,25 Power source calculus V12 8 = V96 Power source DC V96 / A0,25 EXAMPLE 3 / Diagram of 4 + 4 Medea lamps with two connection systems in parallel, connected in series to each other Amount of lamps 8 Connection Series / parallel Lamp current V 12 / A0,25 Power source calculus A0,25 4 = A1 V12 2 = V24 Power source DC V24 / A1
www.dyaqua.it/medea info@dyaqua.it Le lampade Medea sono un prodotto dyaqua medea lamps are a dyaqua product