Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

Similar documents
Water blocking tape. Locator ridge HPA-0486

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

INSTALLATION INSTRUCTIONS

FusionLink Central Tube Ribbon Preparation & handling procedure

SUMITOMO RECOMMENDED PROCEDURE SRP SP-F Ribbon Indoor/Outdoor Riser Cable Preparation

Triax TechInfo. Installing and pulling Fibre Optic cables

FREEDM Loose Tube Interlocking Armored Cables

Crimp & Cleave Termination Instructions for SEL ST Connectors

TECHNICAL GUIDELINE. Universal/Toneable FTTP Cable Applications Guideline. Materials Required

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Buffer Tube Midspan Access Tool Accessing fibers in buffer tube procedure

Furcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD

E2O6CMRXP-1T9 drop fiber leg preparation

2178-L/S Series Fiber Optic Splice Case with Gasket

Optical Distribution Box 300 Installation Guide. Version : R0.0

OmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet

Instructions. Cable with Armor F CAUTION. October Rev A

3M Better Buried Compound Compression Closure System

VITALink Taped Splice Straight Through Crimp

27mm ECAM Double Cable Entry Port

3M Fiber Optic Wall Mount Enclosure 8430 Series

18mm ECAM Cable Entry Port

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Medium Box for Cable Termination

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

Replacing the PanelMate epro PS, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-12 Series Backlight Assembly

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

SECTION FIBER OPTIC STATION CABLES

Panduit Recommended Best Case Practice Split Fibre

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

Gel-sealed in-line fiber optic closure

Underground Installation of Optical Fiber Cable by Pulling

DIY. How to install a PL-259 connector. Parts list: Tools list: Worthwhile projects you can build on your own

3M Better Buried Closures

SLiC Fiber Aerial Closure System

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

3 SLiC Aerial Closure with Rubber End Seal

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

HCS - HES Cabling Systems

3M Cold Shrink Foldback Splice Jacket Kit

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

Splice Closure Fiber (SCF) Family

FIBER OPTIC CABLE PULLING

Table 4-1: Rating Levels

Part Number (used with PRO-CRIMPER Tool Frame ) for 50 Ohm BNC Dual Crimp MIL Type Connectors

IP-LINX Fiber :: X-XXXX

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

IP-LINX. Installation Guide

Aerial Cable Installation Best Practices

FOSC 450 C6 and D6 Closures

INSTALLATION INSTRUCTIONS

LCC (Little Coaxial Connector) Installation Instructions)

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

Installation Overview

SOLO ADSS Short-Span Cables, Fibers

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

Cable installation guidelines

Installation of Optical Fiber

Vibratory Deck Sieves 15 in. (380 mm)

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

Instruction manual. Midi Fiber Dome. Instruction manual

Section Communications Optical Fiber Backbone Cabling

Multi-Media Installation Guide

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

SPECIFICATION. Spec No : VSS-1402-CS603B

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

3M Distribution Box (DDB)

SBN Pendant Pushbutton Station. Instruction Manual. Part Number: R1 January 2016 Copyright 2016 Magnetek Material Handling

Limited Tension Formed Wire Dead End for ADSS Cable

Installation of Solo ADSS All-Dielectric Self-Supporting Fiber Optic Cables

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE Test Method for Cable Weld Integrity

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

DXE-UT-808X Coaxial Cable Stripping Tool

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

READ ME FIRST. Touchstone TV Lift

Safe, Accurate, and Repeatable

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

3M No Polish Jacketed SC/APC Connector

FOSC 400 A4 Fiber Optic Splice Closure

NewScope-7A Operating Manual

3M Cold Shrink Splice Kit QS-III 5515A

Transcription:

revision history Issue Date Reason for Change Related literature SRP-004-136 Accessing All-Dielectric DX Armored Fiber Optic Cables Admonishments 1. General This procedure provides instructions for installing a wire mesh pulling grip on Corning Cable Systems DX Armored Riser and Plenum Rated Fiber Optic Cables. The DX Armored Cable contains a multi-fiber tight buffered fiber optic cable which is not connectorized. Refer to the appropriate cable specification sheet or catalog for the maximum tensile load rating of the cable to be installed. This issue includes grip installation on cables with the All-Dielectric armor referred to as DX armor. STANDARD RECOMMENDED PROCEDURE 004-137 ISSUE 2 SEPTEMBER 2009 PAGE 1 OF 7 Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables cat. number 004-137, Issue 2 2 September 2009 Correction of typograpical error in Figure 4 1 May 2009 Initial Release The precautionary terms used by Corning Cable Systems in its standard recommended procedures conform to the guidelines expressed in the American National Standards Institute document (ANSI Z 535) for hazard alert messages. Alerts are included in this instruction based on the following: DANGER: indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING: indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. PRETERMINATED SYSTEMS CABLES CONNECTORS CABLE ASSEMBLIES HARDWARE TOOL KITS AND ACCESSORIES TEST EQUIPMENT SPLICE EQUIPMENT FAN-OUT KITS TRAINING

2. Precautions General Precautions Safety Glasses WARNING: The wearing of safety glasses to protect the eyes from accidental injury is strongly recommended when handling chemicals and cutting fiber. Pieces of glass fiber are very sharp and can easily damage the cornea of the eye. Safety Gloves WARNING: The wearing of safety gloves to protect your hands from accidental injury when using sharp bladed tools is strongly recommended. Use extreme care when the tool is open and its blades are exposed. Dispose of used blades properly. Cable and Fiber Handling Precautions CAUTION: Fiber optic cables are sensitive to excessive pulling, bending and crushing forces. Excessive bending will cause kinking which may damage the fibers inside the cable may have to be replaced. 3. Tools and Materials The following tools and materials are required to complete this procedure: Kellems pulling grip Side cutters (diagonal cutting pliers) * Tape measure * Permanent marking pen * Utility knife with hook blade * or cable knife Vinyl tape, 3/4 in (19.1 mm) * Friction tape, 3/4 in (19.1 mm) Coaxial Cable Cutter (large blue Ideal tool) Gloves Scissors * Swivel, ball-bearing type Hex wrench or screwdriver (to fit swivel)* Items included in the M67-003 Fusion Splicer Tool Kit 4. Pulling Grip Selection and Installation on Cables with DX Armor Outside Diameter Step 1: Prior to installation, the proper size grip must be chosen for the cable to be pulled. Grip selection is based on the outside diameter of the cable (Figure 1). Figure 1 Cable OD STANDARD RECOMMENDED PROCEDURE 004-137 ISSUE 2 SEPTEMBER 2009 PAGE 2 OF 7

Step 2: Generally speaking, use the smallest grip which will fit over the cable without excessive difficulty. Measure the outer diameter and determine the proper grip by locating the diameter in Table 1: Cable Diameter and Grip Size If cable diameter is Grip is Corning Kellems in the range of... part number part number 2.5-5.6 mm (0.10 to 0.22 in.) GRP-010 033-29-1182 5.3-9.0 mm (0.21 to 0.35 in.) GRP-011 033-29-1182 9.1-12.2 mm (0.36 to 0.48 in.) GRP-012 033-29-1184 12.3-15.5 mm (0.49 to 0.61 in.) GRP-013 033-29-1185 15.6-18.5 mm (0.62 to 0.73 in.) GRP-014 033-29-1186 18.6-22.1 mm (0.74 to 0.87 in.) GRP-015 033-29-1187 22.2-25.4 mm (0.88 to 1.0 in.) GRP-016 033-29-1188 Table 1 Step 3: Once the proper grip is obtained, inspect it for damaged or broken wires, bulges due to stress, rust, etc. Grasp the pulling eye in one hand (gloves are recommended) and smooth out the mesh with the other, tightening the wires. Figure 2 illustrates the technique, which is critical when reusing grips. Figure 2 Grip inspection Step 4: To ease installation, trim the end of the cable with side cutters to remove any protruding armor, buffered fibers or yarn (Figure 3). Figure 3 Cable end trimming STANDARD RECOMMENDED PROCEDURE 004-137 ISSUE 2 SEPTEMBER 2009 PAGE 3 OF 7

Step 6: Table 2 and Figure 4 indicate the outer jacket strip length (A), exposed armor length (B), and exposed cable core length (C) required for each grip installation. Mesh Length A B C 45 cm 50 cm 15 cm 35 cm (18 in.) (20 in.) ( 6 in.) (14 in.) 53 cm 48 cm 18 cm 40 cm (21 in.) (23 in.) ( 7 in.) (16 in.) Mesh length 60 cm 65 cm 20 cm 45 cm (24 in.) (26 in.) ( 8 in.) (18 in.) B A C 68 cm 75 cm 25 cm 50 cm (27 in.) (30 in.) (10 in. (20 in.) 75 cm 83 cm 30 cm 53 cm (30 in.) (33 in) (12 in.) (21 in.) Table 2 Figure 4 Outer jacket marking lengths Measure and mark lengths C from the end of the cable on its outer jacket (Figure 5). C A Figure 5 Strip length markings Step 7: Use a pumping action to walk the grip over the cable by bringing your hands together and then relaxing them until the end of the grip is past the A mark on the cable (Figure 6) A Figure 6 Walking the grip Step 8: Using the coaxial cable cutter, make a ring cut through the outer jacket and score the armor at the C strip-length mark (Figure 7). It may take several rotations (5-7 or more) depending on blade sharpness. Do not cut into inner cable jacket. It is safer to make several rotations, flex and try to snap the armor and repeat the process rather than to cut though outer and inner jackets at once. Figure 7 Ring cutting the jacket STANDARD RECOMMENDED PROCEDURE 004-137 ISSUE 2 SEPTEMBER 2009 PAGE 4 OF 7

Step 9: Gently flex the cable until the DX armor snaps and remove the armor and outer jacket to expose the inner cable (Figure 8). Figure 8 Exposed cable Step 10: Ring cut the inner jacket at the end of the exposed armor and 15 cm (6 in.) from the end of the cable (Figure 9). Use care to avoid damaging the aramid yarn strength elements under the jacket. Ring cuts 15 cm (6 in) Figure 9 Ring cutting the inner jacket Step 11: Position the blade of the hook blade knife at the 15 cm (6 in) ring cut so that it can travel down the cable between the jacket and the cable core towards the cable end. 45 Hold the knife at a 45 angle to the cable to prevent the blade from slipping out of the jacket Slit the 15 cm (6 in.) section of inner jacket by holding the arm which has the knife out straight and pulling the cable through the hook blade with your other hand (Figure 10). Figure 10 Slitting the inner jacket Step 12: Remove the 15 cm (6 in) section of jacket to expose the rip cord. Step 13: Carefully separate the rip cord from the aramid yarn and other components of the cable core. Place a wrap of tape around the cable core to hold these components in place (Figure 11). Figure 11 Exposing the rip cord STANDARD RECOMMENDED PROCEDURE 004-137 ISSUE 2 SEPTEMBER 2009 PAGE 5 OF 7

Step 14: To remove the remaining exposed inner jacket: a) Carefully cut a starting notch in the inner jacket with a hook blade. b) Wrap a rip cord around the shaft of a screw-driver, short section of scrap cable, or other object which can serve as a handle. c) Pull the rip cord through the jacket to the ring cut (Figure 12). d) Cut the rip cord flush at the ring cut. Figure 12 Pulling the rip cord Step 15: Remove the jacket from the DX armor back to the A mark (Figure 13). Figure 13 Exposed cable core Step 16: Place a wrap of friction tape over the exposed DX armor and over the entire length of the exposed cable core (Figure 14). Note: Do not apply any friction tape over the outer jacket- the grip will not slide over the cable. Figure 14 Covering the cable core with Friction tape Step 17: Walk the grip over the friction tapecovered cable core until the cable end is in the middle of the grip basket (Figure 15). Grip basket Cable end Figure 15 Cable-end position in grip STANDARD RECOMMENDED PROCEDURE 004-137 ISSUE 2 SEPTEMBER 2009 PAGE 6 OF 7

Step 18: Smooth the mesh back over the cable core, moving from the pulling eye to the cable jacket. Tug on the grip to tighten it against the core (Figure 16). Figure 16 Tightening the grip Step 19: Starting at least 2.5 cm (1.0 in.) below the mesh on the cable jacket, wrap vinyl tape TIGHTLY to the top of the grip. The mesh s imprint should show clearly through the tape (Figure 17). The tape must be tight because it helps compress the mesh against the cable core. Tug on the grip slightly to tighten it. Figure 17 Taping the grip Note: When two or more vinyl tape layers are desired, always wrap the final, outside layer from the cable jacket to the pulling eye. This layers the tape like roofing shingles, so that it will not snag as it moves through a duct. Step 20: Connect the pulling eye to the appropriate ball bearing swivel and pull tape or line (Figure 18). The grip installation is now ready for the cable placement. Pull line Figure 18 Swivel and pull line Grip Removal After completion of the pull, cut the cable 91 cm (36 in.) behind the grip. Place a protective cap over the exposed cable end and tape in place to prevent water intrusion. Store the coiled splicing slack so that it is protected from damage. Corning Cable Systems LLC PO Box 489 Hickory, NC 28603-0489 USA 800-743-2675 FAX: 828-901-5973 International + 1-828-901-5000 www.corning.com/cablesystems Corning Cable Systems reserves the right to improve, enhance, and modify the features and specifications of Corning Cable Systems products without prior notification. All trademarks are the property of their respective holders. Corning Cable Systems is ISO 9001 certified. 2009 Corning Cable Systems LLC. All rights reserved. STANDARD RECOMMENDED PROCEDURE 004-137 ISSUE 2 SEPTEMBER 2009 PAGE 7 OF 7