DI-145 USB Data Acquisition Starter Kit

Similar documents
LAUREL ELECTRONICS, INC.

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

DAC Express Release 3.4 (VT9801B)

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

PicoScope 6407 Digitizer

ScopeMeter 190 Series Specifications

AI-1664LAX-USB. Features. 100KSPS 16-bit Analog Input Unit for USB AI-1664LAX-USB 1. Ver.1.01

ML785 PowerLab/8SP ADInstruments Data Acquisition Systems

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Major Differences Between the DT9847 Series Modules

PicoScope 6407 Digitizer

DT9857E. Key Features: Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels

2 MHz Lock-In Amplifier

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

Digital Storage Oscilloscopes 2550 Series

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

SCALE & WEIGHT DISPLAYS

2 MHz Lock-In Amplifier

AD16-64(LPCI)LA. Non-isolated high precision analog input board for Low Profile PCI AD16-64(LPCI)LA 1. Ver.1.01

4 MHz Lock-In Amplifier

MTL Software. Overview

medlab One Channel ECG OEM Module EG 01000

WaveDriver 20 Potentiostat/Galvanostat System

AI-1204Z-PCI. Features. 10MSPS, 12-bit Analog Input Board for PCI AI-1204Z-PCI 1. Ver.1.04

TempScan/1100 & MultiScan/1200

ATS MS/s 8-Bit PCI Digitizer

2x2 HDMI Matrix Switch - 4K with Fast Switching and Auto-Sensing

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

Operating Instructions

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

DT3130 Series for Machine Vision

The measurements are stored in non-volatile memory, which retains data even when the power down.

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

PicoScope PC Oscilloscopes. User's Guide. ps2203.en r4 Copyright Pico Technology Limited. All rights reserved.

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Ethernet to VGA over IP Converter

EAN-Performance and Latency

PicoScope 4000 Series PC Oscilloscopes

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

DM1624, DM1612, DM812

QRF5000 MDU ENCODER. Data Sheet

HDMI Over IP Extender Kit - 4K

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

Agilent Technologies 54522A

Dell Wyse 5030 PCoIP Zero Client

System Requirements SA0314 Spectrum analyzer:

DisplayPort to HDMI Multi-Monitor Splitter - 3-Port MST Hub

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Quick Operation Guide of LTN7700/7600 Series NVR

OPTICAL POWER METER WITH SMART DETECTOR HEAD

PicoScope 4000 Automotive PC Oscilloscopes

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

AI-1616L-LPE. Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE 1. Ver.1.02 Ver.1.01

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

PicoScope 2000 Series PC Oscilloscopes

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Lab 1 Introduction to the Software Development Environment and Signal Sampling

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

EVD-L04/100A1-960, EVD-L08/200A1-960 and. EVD-L16/400A1-960 DVRs. Quick Operation Guide

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

Choosing an Oscilloscope

BNC-2110 DESKTOP AND DIN RAIL-MOUNTABLE BNC ADAPTER

USB Smart Power Sensor

2-Port HDMI Automatic Video Switch - 4K with Fast Switching

NI PXI/PXIe-2543 Specifications

SuperSpeed USB 3.0 to HDMI Audio Video Adapter for Windows & Mac up to 2048x1152 / 1920x1200

DVG MPEG-2 Measurement Generator

Operating Instructions

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

PicoScope 3000 Series Automotive User guide

HOBO H Energy Logger

Direct PWM. 1000/2000 Series POWERBLOK MODULE

AF-300 E11 Adjustable Frequency Drive

Advanced Test Equipment Rentals ATEC (2832)

263 Series LED Bargraph Indicator and Controllers

USB C to HDMI Multi-Monitor Adapter - 3-Port MST Hub

Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series

PulseCounter Neutron & Gamma Spectrometry Software Manual

Operating instructions Electronic preset counter Type series 717

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

Portable Performance for Debug and Validation

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

What to look for when choosing an oscilloscope

MS2540 Current Loop Receiver with RS485 Communication

Expect to Make Waves.

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

JD725A Cable and Antenna Analyzer - Dual Port

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

Transcription:

DI145, Datenblatt Seite 1 DI145 USB Data Acquisition Starter Kit Lowcost, Compact USB Data Acquisition Starter Kit Four ±10 V Differential Analog Inputs protected to ±150 V 10bit Resolution Up to 240 Hz Sample Rate 2 Dedicated Digital Inputs Provided with WinDaq/Lite Software The DI145 is a new product in a long line of lowcost starter kits from DATAQ Instruments. Suitable for measuring preamplified analog signals, the DI145 in tandem with the included WinDaq software allows real time data acquisition, playback, and analysis performance equal to or better than other products that cost ten times or more than its low price. Predecessors of this instrument have been sold to over 20,000 hobbyists and professionals for countless data acquisition applications around the world. The DI145 continues this legacy with an improved interface, and noisecancelling differential analog inputs that are transientprotected to ±150 VDC or peak AC. This is our toughest and most tolerant starter kit ever. The DI145 offers four analog input and two discrete (digital) input channels. The analog inputs offer a fixed measurement range of ±10VFS, and are multiplexed to an integrated 10bit ADC. Both analog and digital inputs are protected to ±150 and ±30 VDC or peak AC respectively. Sample rates as slow as 2.23 per min. and as fast as 240 per sec. (divided by the number of enabled channels) are supported. Included WinDaq software allows a real time display of any combination of analog channels, and the ability to stream acquired data to disk in recorderlike fashion. The DI145 s two digital inputs are dedicated for remote stop/start and remote event operations using WinDaq software. WinDaq also includes software to review recorded data files, including waveform analysis and data file export to Microsoft Excel and other applications. Four Analog Input Channels Connect the DI145 to any preamplified signal in the typical range of ±5 to ±10VFS. 10bit ADC resolution Provides 19.5 mv resolution across the entire DI145 measurement range. Ruggedized Inputs All four DI145 analog inputs and both discrete inputs are overvoltage protected. Accidents that happen are quickly forgiven. Noisecancelling Analog Input Configuration The noiseimmunity of differential inputs minimizes the affects of common mode noise so often encountered in industrial measurements. Builtin USB interface The DI145 is provided with a builtin USB interface, allowing it to be connected and run with any laptop or desktop PC. The USB interface provides power to the DI145, eliminating clumsy external power supplies. Backwardcompatible with DI 194RS Protocol OEM software that was written to support the DI194RS protocol will work with the DI145 in its special DI194RS emulation mode. Features Wide OS support Signed drivers are provided with the DI 145 that allow troublefree installation for Windows XP and both 32 and 64bit versions of Windows Vista and Windows 7. Included WinDaq/Lite software Our WinDaq/Lite data acquisition software offers real time display and disk streaming for the Windows environment. The real time display can operate in a smooth scroll or triggered sweep mode of operation, and can be scaled into any unit of measure. markers with comments allow you to annotate your data acquisition session with descriptive information as you re recording to disk. Raise your productivity to new heights with WinDaq s unique multitasking feature. Record waveform data to disk in the background while running any combination of programs in the foreground even WinDaq Playback software to review and analyze the waveform data as it s being stored! Playback supports waveform analysis (Statistics, XY plots, frequency analysis) and the ability to export data to Microsoft Excel. WinDaq/Lite recording and playback software is provided free with every DI145 purchase. See the WinDaq Multimedia Tutorial for more information. Download software for the DI145 at www.dataq.com/145.

DI145, Datenblatt Seite 2 DI145 Closeup Remote pushbutton Trigger events either from the remote event inputs (through WinDaq software) or by pushing this button. LED Indication LED indicates power is applied. Active LED indicates the device is recording to disk. Digital LED indicates use of a digital input. Bulkhead Mounting Ears Bulkhead Mounting Ears MiniB USB connection Analog In Channels 14 ±10VFS, ±150 transient Max. Digital In Channels For Remote Start/Stop using WinDaq Screw terminals for signal inputs Reserved No Connection Dimensional Drawing 1.612" Ø 0.200" (2 places) 2.625" 0.750" 4.250" 4.750" 5.500" althensensors.co

DI145, Datenblatt Seite 3 DI145 Block Diagram 0.01μf 160K 1M 10 AIN1 1M 0.01μf 160K Analog In Typical 4 places ½Vref 0.1μf EEPROM (Calibration, Model #, Serial #) V AIN2 Analog In 2 AIN3 AIN4 Analog In 3 Analog In 4 General Purpose I/O SPI Port AVR32 CPU General Purpose I/O V V Reg V Remote Active DIN0 Digital In 0 (Remote s) ADC USB VBus USB V 47K 100pf ATMEL Microcontroller DIN1 (Remote Start/Stop) 47K Panel 4.7K VBias Digital In (½VCC) Typical 2 places Panel

DI145, Datenblatt Seite 4 Setup Included WinDaq/Lite Recording Software (click on graphics for closeup views) Doubleclick and enter the channels you want to acquire into the WinDaq scan list. Click to select signal averaging, true RMS, frequency, and peak or valley detection per channel. Click to define a single to 4channel display either triggered sweep (oscilloscopelike) or scrolling (chart recorderlike). Click again to define a sample rate ranging from less than 2.23 samples per minute to 240 samples per second. Calibrate Define calibration per channel to display waveform values in meaningful units such as psi, F or C, amps, rpm, watts, horsepower any unit of measure you need. Record Choose a continuous waveform recording mode or the triggered mode with selectable trigger level, slope, and posttrigger times. WinDaq automatically time and datestamps, then streams acquired data to disk record as much data as you need. At the same time, WinDaq supplies a realtime graphical display of any or all channels so you always know where you are and where you re going. Annotate Of course, you can label any channel with text that describes it Motor 1, Engine speed, Vertical position, etc. But WinDaq also allows you to supply commented event markers while you record Beginning test phase 1, Small vibrations noticed, Starting cooldown cycle, etc. Your comments and our acquired data combine to form a complete diary of your data acquisition session.

DI145, Datenblatt Seite 5 Playback Included WinDaq Playback Software Recording is only half the solution. WinDaq s Waveform Browser playback software allows you to graphically manipulate waveforms in ways you ve never seen on a PC. Compress an entire recording to one screenwidth for a bird s eye view, then expand around an area of interest for a closer look. Use the cursor to measure amplitudes and timing with precision. Move to any event marker with the click of a mouse button. Multitask Double your productivity and let WinDaq record while you review last week s results from your spreadsheet, or compose a memo with your word processor. You can even play back data already stored to disk while you re still recording. Analyze Waveform interpretation is easy with our builtin analysis functions. Apply frequency and filtering analysis with the WinDaq Waveform Browser FFT and DFT functions. Analyze any range of waveform data with the statistics function. Use XY plotting to examine the relationship of one channel to another. Optional Advanced CODAS analysis functions allow waveform peak detection, integration, differentiation, arithmetic operations, and more. Export The WinDaq Waveform Browser can export any range of data to your spreadsheet, or any other analysis or presentation package you use. You can even copy a graphical image displayed by the WinDaq Waveform Browser and paste it directly into a word processing document. Finally, export any range of waveform graphics to your printer for a hard copy record.

DI145, Datenblatt Seite 6 Typical DI145 Applications Replace Traditional Chart Recorders Digitize and record measurements from instruments with highlevel analog outputs. Equipment PC Model DI145 Active Model DI145 Data Acquisition Starter Kit Download software at dataq.com/145 Analog Out ±10VFS www.dataq.com Remote Analog inputs (±10 VFS, ±150 V max.) Remote Control Reserved Ch1 Ch2 Ch3 Ch4 Record USB Cable (3 more analog input channels as needed) Any Windowscompatible computer see specifications for supported Operating Systems Examples of Equipment above include gas chromatographs, liquid chromatographs, spectrometers, bioamplifiers*, etc. * DATAQ Instruments hardware and software products are NOT designed to be used in the diagnosis and treatment of humans, nor are they to be used as critical components in any lifesupport systems whose failure to perform can reasonably be expected to cause significant injury to humans. Amplified Transducer Monitor Connect directly to and record the output of amplified voltage or currentmode transducers. Model DI145 R250* Transducer/Sensor** Ch1 Ch2 Ch3 Ch4 Analog inputs (±10 VFS, ±150 V max.) Remote Control Record Remote www.dataq.com Active Model DI145 Data Acquisition Starter Kit PC Reserved Download software at dataq.com/145 USB Cable *Model R250 resistor required for 420mA outputs **Typical Transducer/Sensor above includes pressure, load, torque, etc. Any Windowscompatible computer see specifications for supported Operating Systems Typical Transducer/Sensors above include pressure, load, torque, Etc.

DI145, Datenblatt Seite 7 Typical DI145 Applications (continued) Process Monitoring Trend plot and record control and feedback signals to troubleshoot process glitches. Control and Feedback Signals (±V, 420mA*) PLC Process Model DI145 Data Acquisition Starter Kit PC Active Download software at dataq.com/145 Remote www.dataq.com Analog inputs (±10 VFS, ±150 V max.) Ch1 Ch2 Ch3 Ch4 Remote Control Record Reserved USB Cable *Model R250 resistor required for 420mA outputs Model DI145 Any Windowscompatible computer see specifications for supported Operating Systems Remote Control Close Up The DI145 supports several methods to increase measurement flexibility and data record interpretation. The remote record feature allows you to synchronize WinDaq recordings to external processes by remotely enabling and disabling WinDaq s streamtodisk feature. Remote events allow you to insert an event marker in the data stream (see inset) to identify when an event occurred relative to recorded waveform activity. s can be activated by the pushbutton on the DI145 enclosure, though a keyboard keystroke (which also allows you to record a description), or remotely via the remote event input. The streamtodisk function can also be controlled through the keyboard, or through the remote record input. Valid remote record and event signals are switch closures, or discrete levels with a maximum input of 30 V and a threshold of 1.8 V. Marker TTL 30V Max 0V 1.8V Threshold Switch Closure TTL or Switch Closure ed max.) Remote Control NC Ch4 NC Record ataq.com

DI145, Datenblatt Seite 8 Signal Inputs Analog Inputs Number of Channels: 4 Configuration: Differential Full Scale Range: ±10VFS Input impedance: 1 MΩ, each input to ground Isolation: none Accuracy: ±0.25% of FSR Overall inaccuracy: ±64mV (at 25 C) DC common mode rejection: 40db (at 25 C) Max input without damage: ±75 V peak, continuous ±150 V peak, one minute or less Max common mode voltage: ±10V Analog frequency response: 3db @ 100 Hz Digital Inputs Number of Channels: 2 Pullup value: 47 KΩ from input to to 3.3V Pulldown value: 4.7 KΩ from input to USB ground Input high voltage threshold: 1.8 V minimum Input low voltage threshold: 1.4 V maximum Operating range: 0 30 V Absolute maximum values: ±30 VDC ADC Characteristics Resolution: Max sample throughput rate: Min sample throughput rate: Sample rate timing accuracy: Overall: 1 part in 1,024 (10bit) Above zero: 1 part in 511 Below zero: 1 part in 512 1 ADC Count = ±19.5 mv 240 Hz 0.44 samples per minute 50 ppm DI145 Specifications Ordering Guide Reserved Inputs (Digital Inputs) Digital In 0: WinDaq remote start/stop Digital In 1: WinDaq remote events Indicators and Connections Interface: USB 2.0 (minib style connector) Indicators (LED):, Active, Digital Input Connections: One 16position terminal strip Consumption: Environmental Operating Temperature: Operating Humidity: Storage Temperature: Storage Humidity: 0.30 watts, via USB interface 0 C to 35 C (32 F to 95 F) 0 to 90% noncondensing 20 C to 45 C (4 F to 113 F) 0 to 90% noncondensing Physical Characteristics Enclosure: Hardened Plastic Mounting: Desktop; bulkhead Dimensions: Weight: Software Support WinDaq/Lite software: Backwards compatability: Programming: 2.625D 5.5W 1.53H in. (6.67D 13.97W 3.89H cm.) 3.6 oz. Description DI145 Data Acquisition Starter Kit Data acquisition device with USB cable, screwdriver, and free WinDaq/Lite software via Internet download (www.dataq. com/145). OS support: Windows XP (32bit), Windows Vista and Windows 7 (32 and 64bit versions) Sample Rate Limit: 240 Hz DI194RS compatibility mode supports Linux and MatLab DATAQ Instruments SDK Order No. DI145 R250 Optional precision 250ohm 420 ma shunt resistor (see nonisolated implementation here). R250 DATAQ, the DATAQ logo and WinDaq are registered trademarks of DATAQ Instruments, Inc. All rights reserves. Copyright 2012 DATAQ Instruments, Inc. The information on this data sheet is subject to change without notice. ALTHEN GmbH Meß und Sensortechnik Frankfurter Straße 150152 65779 Kelkheim Tel.: 49 (0) 61 95 70 06 0 Fax: 49 (0) 61 95 70 06 66 info@althen.de althen.de ALTHEN GmbH 2014