BCS 4R DSX-3 Connectivity System. Models , , and User Manual

Similar documents
Broadband Connectivity System II

DS1 Cross-Aisle Panel

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

DIGITAL DISTRIBUTING FRAME (DDF) INSTALLATION PROCEDURES FOR PANELS AND MODULES

ICS-75. Integrated Combiner Shelf Installation and Operation Manual Part Number MN/ICS75.IOM Revision 5

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

ADF Module. Installation Guide. 1.1 Overview

Model /29S RF Splitter

Traditional RF Splitter/Combiner and Directional Coupler User Manual

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Instruction Manual. 4x1 VGA Routing Switcher Series

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

8024-DSS-02 Issue 2. DSS-8024 Dual Serial Switch USER MANUAL

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

E3/DS3 Tap. 6xBNC Type

HighBand 25. TrueNet Category 6 Solutions

LGX Compatible (LSX) Connector Module) User Manual)

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

SECTION SYNCHRONIZATION

32 Channel CPCI Board User Manual

Power Injector 1520 Series

Preventing Fieldbus Physical Layer Problems

Dish Diversity Switch

Model R177M and R177S Baseband Switch

Instruction Manual Model # Block Upconverter

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D

DIGITAL SWITCHERS 2100 SERIES

MS2540 Current Loop Receiver with RS485 Communication

TracVision R6DX Installation Guide

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

Video Patching Systems ProPatch Miniature (PPM) Series

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

Headend Systems. Series 9900 RF Signal Manager Modules. Introduction. Description

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

Colour Explosion Proof Video Camera USER MANUAL VID-C

User Manual. Model HCX-11 HDMI Coax Extender. Five-Coax Extender Model HCX-11. Five-Coax Extender Model HCX-11

Troubleshooting Guide 9630 Series

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

WC-2100 WORD CLOCK DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

UTP ACTIVE TRANSCEIVER HUB

Model 1421 Distribution Amplifier

Kramer Electronics, Ltd. USER MANUAL. Model: VM-10xl. Video Audio Distribution Amplifier

Common Public Radio Interface Fiber :: Telect HDX & ELF CPRI Panels and Modules

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL.

ACTIVE IF SPLITTER/COMBINER UHP-IFS

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

Trusted 40 Channel 120 Vac Digital Input FTA

Model UH-2C-3S 3-port HDMI UTP Extender

QDA4-44 RF Amp/Combiner

QCA9-33 Active Combiner

User Manual. Model 979T and 979R Digital Audio Converters

Kramer Electronics, Ltd.

Instruction Manual Model BlockUpconverter

IP-LINX. Installation Guide

Trusted 40 Channel Analogue Input FTA

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

Z-IP Stream 004/008. User Guide and Installation Manual. Four or Eight Input QAM Encoder / Modulator

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

User Guide. Centrex Recording Interface

DSX-1 Cross-Connect Procedures

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

Digital Magic On Hold System

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Assembly Level Service Guide

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

DSX-1. Copper :: DS1 Series User Manual. Applys to : DS1 Series BATT RTN SGND MON OUT. T Out R T. Front Cross-Connect TL T R T R. Out.

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

SignalOn Series. L-Band Splitter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

INSTALLATION MANUAL. CT-DUC-DDC Digital Off-Air Up Converter and Down Converter

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

T10 Float Level Switch

Satellite Radio DBS Multiplex Kit

LCC (Little Coaxial Connector) Installation Instructions)

ENGLISH Antenna Distributor

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

Truck router (3Gbps/HD/SD/ASI)

3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater. Installation and Operations. Manual

Model P/03P Upconverters

Kramer Electronics, Ltd. USER MANUAL. Model: VP-12NHD. 1: UXGA / CAT5 Distributor

OPTICA TECHNOLOGIES INCORPORATED and the OPTICA TECHNOLOGIES INCORPORATED logo are trademarks of Optica Technologies Incorporated.

Trusted 40 Channel 120 Vac Digital Input FTA

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

Kramer Electronics, Ltd. USER MANUAL. Model: WP-210A. XGA/Audio Line Driver

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

Transcription:

BCS 4R DSX-3 Connectivity System Models 010-8332-0410, 010-8332-0401, 010-8324-0410 and 010-8324-0401 User Manual

BCS 4R DSX-3 Connectivity System Models 010-8332-0410, 010-8332-0401, 010-8324-0410 and 010-8324-0401 User Manual, Part number 139256 Copyright 2010, Telect, Inc., All Rights Reserved Telect and Connecting the Future are registered trademarks of Telect, Inc. 1730 N Madson St., Liberty Lake, Washington Telect assumes no liability from the application or use of these products. Neither does Telect convey any license under its patent rights nor the patent rights of others. This document and the products described herein are subject to change without notice. About Telect Telect offers complete solutions for physical layer connectivity, power, equipment housing and other network infrastructure equipment. From outside plant and central office to inside the home, Telect draws on more than 25 years of experience to deliver leading edge product and service solutions. Telect is committed to providing superior customer service and is capable of meeting the dynamic demands of customer and industry requirements. This commitment to customer and industry excellence has positioned Telect as a leading connectivity and power solution provider for the global communications industry. Technical Support E-mail: getinfo@telect.com Phone: 888-821-4856 or 509-921-6161 Page ii

BCS 4R DSX-3 Connectivity System User Manual Table of Contents Chapter 1: BCS 4R DSX-3... 1 1.1 Introduction to Telect s BCS 4R... 1 1.1.1 BCS 4R Fully-Loaded Chassis... 3 1.1.2 BCS 4R DSX-3 Module (Models 010-8301-0401 & 010-8302-0401)... 4 1.1.3 BCS 4R Chassis (Model 010-0000-8301 and 010-0000-8302)... 5 1.1.4 Applications...6 1.1.5 Cutover / Acceptance Activities... 6 1.1.6 Restoration of Service Activities... 6 1.1.7 Routine Maintenance Activities... 6 1.1.8 Features / Capabilities / Capacities / Benefits... 7 1.1.9 Compliance... 7 1.2 DSX-3 Specifications...8 Chapter 2: Installation... 9 2.1 Installation Considerations... 9 2.1.1 Location and Space... 9 2.1.2 Computer Floor Issues... 10 2.1.3 Required Tools and Equipment... 10 2.2 Inspection... 10 2.3 Installation... 11 Chapter 3: Electrical Operation... 17 3.1 Power... 17 3.1.1 Tracer Lamps (TL)... 18 3.1.2 Monitor Ports... 18 3.2 DSX Cross-Connections... 18 3.2.1 Backplane Cross-Connections... 18 3.2.2 DSX Card Front Patch... 20 Chapter 4: Service... 21 4.1 Owner Maintenance... 21 4.2 Troubleshooting Cross-Connected Signals... 21 4.3 Replacing the Tracer Lamp LED... 21 4.4 Service... 21 4.4.1 In-Warranty Service... 21 4.4.2 Out-Of-Warranty Service... 22 4.5 Repacking For Shipment... 22 Page iii

List of Figures Figure 1 - Basic Chassis... 1 Figure 2 - Rear View of Fully Loaded Chassis... 2 Figure 3 - Network Element Circuits... 3 Figure 4 - Cross-connect Inputs... 4 Figure 5 - Model 010-0000-8301...5 Figure 6 - Rack... 9 Figure 7 - Mounting Chassis to Rack... 11 Figure 8 - Routing Power... 12 Figure 9 - Grounding the Chassis... 13 Figure 10 - BNC Insertion Tool... 13 Figure 11 - Connections... 14 Figure 12 - Rear Cross-Connect Cables with Tracer Wire... 15 Figure 13 - Power from Distribution Panel to Front Tracer Lamp... 17 Figure 14 - Tracer Lamp Operation... 18 Figure 15 - Schematic Drawing of Cross-Connection... 19 Figure 16 - Rear Cross-Connect Cables with Tracer Wire... 19 Figure 17 - Temporary Front Cross-Connect Using Patch Cables & DSX Cards... 20 Page iv

Chapter 1: BCS 4R DSX-3 1.1 Introduction to Telect s BCS 4R Telect s BCS 4R is a low-cost, high-density, space-saving total solution to DSX-3 network element connectivity. Telect s 2 RU BCS 4R chassis accommodates up to 32 of Telect s highly reliable, 6-port BCS 4R DSX-3 modules. Each low-cost DSX-3 module features BNC and Mini-WECO connectors for cross-connecting, patching, testing. and bi-directional monitoring of network element circuits. Panels are available fully configured and loaded with DSX-3 modules, helping to simplify purchasing and installation. Options include 24-termination/19" and 32-termination/23" panels, with 6-port DSX-3 modules. All panels are just 4" in height. Front Rear Figure 1 - Basic Chassis Page 1-1

BCS 4R BCS 4R Figure 2 - Rear View of Fully Loaded Chassis Page 1-2

FRONT REAR REAR FRONT BATT A BATT A TL TL TRACER WIRE TL TL LED ASSEMBLY RTN A RTN A LED ASSEMBLY MON MON R2 R2 OUT OUT OX OX R1 R1 IX IX R1 R1 O O IN I I IN R2 I O O I R2 MON Network Element 1 Network Element 2 MON Figure 3 - Network Element Circuits 1.1.1 BCS 4R Fully-Loaded Chassis Telect now provides fully-loaded 19 and 23 DSX-3 panels. These products come pre-loaded with either 6-port or 4-port modules. See the following table for part numbers. Table 1 - Fully-loaded 19 and 23 DSX-3 panels Chassis Module Part Number 19, 24-position 6-port 010-8324-0410 19, 24-position 4-port 010-8324-0401 23, 32-position 6-port 010-8332-0410 23, 32-position 4-port 010-8332-0401 Page 1-3

1.1.2 BCS 4R DSX-3 Module (Models 010-8301-0401 & 010-8302-0401) Telect s BCS 4R DSX-3 Module is a 4-port passive card module for populating the BCS 4R Chassis. Model 010-8301-0401 fits every odd-numbered shelf position (Positions 1 through 31) and Model 010-8302-0401 fits every even position (Positions 2 through 32). (BCS 4R DSX-3 Module kit [Model 999-8300-0401] contains one odd and one even module.) The BNC connections on the rear of the even versus the odd modules are slightly offset to accommodate 32, side-by-side modules in each chassis. BNC circuit assignments are as follows: Input (I) to and Output (O) from the network element, and Cross-connect input (XI) and output (XO) from/to another DSX-3 module. Cross-connections between DSX-3 Modules should be 27 ft. or less. Figure 4 - Cross-connect Inputs The four ports on the front of the module are Mini-WECO connectors for temporary Input (I) and Output (O) patch cords (734A or 735A cables) from/to a standby DSX-3 circuit, and for temporary Monitor (M) patch cords: The I and O patch connections are intrusive, highly reliable, make-and-break connections that break (disconnect) the cross-connect circuits at the same time making (connecting) the standby circuit. Patch cord connections between DSX-3 modules should be 20 ft. or less. The M connections are non-intrusive connections that allow for testing, diagnosis, and troubleshooting without disconnecting either normal or standby service. The front of the module contains a red tracer LED fed by power supplied from a GMT power shelf. A tracer wire is inserted through the rear of the BCS 4R Chassis; the tracer lamp is lit by grounding the tracer wire at the trace controller. Tracer lamps aid in diagnosing problems by visually mapping out assigned network element cross connections. Page 1-4

1.1.3 BCS 4R Chassis (Model 010-0000-8301 and 010-0000-8302) The 23-in. and 19-in. BCS 4R Chassis are shelves containing 32 and 24 positions, respectively, for BCS 4R DSX-3 modules. Each chassis includes a power backplane to feed -48Vdc, tracer-lamp power to the DSX-3 modules. Each chassis comes with cable management ring assemblies that attach to the rear of the rack and flipout designation cards that attach to the mounting brackets on the front of the rack. (Designation cards are not shown in the following illustration.) All mounting hardware is included. Figure 5 - Model 010-0000-8301 Page 1-5

1.1.4 Applications Telect s BCS 4R System is ideal for central offices and other DSX-3 distributive activities including high-density central offices other DS3 network applications cutover / acceptance activities restoration of service activities routing maintenance activities as well as normal DCS interconnects, or wherever reliable, low-cost DSX-3 connectivity is a must. 1.1.5 Cutover / Acceptance Activities BCS 4R DSX-3 simplifies equipment installation and cutover by providing temporary digital line patch cord connections during new equipment installation. After the new equipment has been wired to the DSX, cross-connections are made to connect the new equipment in its final office configuration. Removing the wiring from the DSX to the old equipment and taking down the patch cords completes the cutover. 1.1.6 Restoration of Service Activities Malfunctioning equipment is readily identified at the BCS 4R DSX-3 by equipment sectionalization (circuit split-test in both directions) and by patching substitute equipment for verification. Digital line patch cords at the DSX can immediately restore any out-of-service facility, whether caused by a cable cut, malfunctioning equipment, etc. Rather than using jacks located at the individual units, manual restoration patching can be done at a centralized location at the DSX. When the equipment or cable is repaired or routing for preventive maintenance is accomplished, the facility can be returned to its original configuration by simply removing the patch cords. 1.1.7 Routine Maintenance Activities Periodic testing of facility parameters assures maintenance of adequate service levels. By terminating all digital office equipment at one central point at the BCS 4R DSX-3 overall testing can be performed from the central location. Periodic testing at DSX test jacks, connected directly to digital equipment inputs and outputs, identifies marginal equipment. Circuit order work is another important routine maintenance activity. Major changes in traffic patterns may leave a surplus of capacity at a vacated area and a shortage at another. Traffic pattern changes are rapidly accomplished by reconfiguring cross-connect jumpers at the DSX. The ability to make these changes at the DSX makes major rewiring unnecessary and results in a reduction of skilled manpower and time requirements. Page 1-6

1.1.8 Features / Capabilities / Capacities / Benefits Telect s BCS 4R offers the following: total front access for patching and monitoring easy access to cross-connections 75Ω impedance support for all coaxial interface digital signal rates (DS3, STS-1, E-3, STM-1, and STS-3) network I/O and Cross-Connect BNCs on the rear; patch and high-impedance Monitor Mini- WECO on the front bi-directional monitoring tracer lamps for identifying cross-connections during troubleshooting fully configured panels that streamline ordering and accelerate deployment high density: 24 terminations in a 19" chassis; 32 terminations in a 23" chassis space savings: Each panel just 4" in height essential functionality: 6-port mini-weco modules enable bi-directional monitoring, patch, test and cross-connect capabilities; 4-port modules also available simplified design: LEDs on front only; cable equipment to panel as you add modules NEBS Certified and backed by Telect's DSX lifetime warranty 1.1.9 Compliance NEBs Level 3 cul us FCC CE Page 1-7

1.2 DSX-3 Specifications Electrical Interface: Specifications: Insertion Loss < 1.00 db at DS3/E3 signal rates Monitor Level 21 db + 1.5 db below signal level Return Loss < -26 db at DS3/E3, STS-1 signal rates < -26 db at E3 signal rate of 17.184 Mhz < -15 db at STS-3/STM-1 signal rates Contact Resistance < 0.01Ω Characteristic Impedance 75Ω Tracer Lamp LED Draws 9mA at -48Vdc Mechanical Interface: Jack Insertion Force Jack Withdrawal Force Jack Life Specifications: 10 lbs maximum, 4.1 lbs. minimum 7 lbs. maximum, 3.8 lbs. minimum Minimum 10,000 insertion/withdrawal cycles Environment: Thermal Ambient Limits Thermal Shock Humidity Specifications: -55 C to 85 C, non-operating -5 C to +55 C, operating per MIL-STD-202, methods 107D 0% to 95%, noncondensing, operating and non-operating Page 1-8

Chapter 2: Installation 2.1 Installation Considerations! CAUTION CAUTION! Only qualified technicians may install and maintain his product. These instructions presume you have verified that the Telect equipment being installed is compatible with the rest of the system, including power, ground, circuit protection, signal characteristics, equipment from other vendors, and local codes or ordinances.! ALERT Use this equipment in a RESTRICTED ACCESS LOCATION ONLY. 2.1.1 Location and Space The BCS 4R chassis mount in standard 19 in. or 23 in. WECO-spaced or EIA-spaced racks. Allow for four inches of vertical space per chassis. BCS 4R Figure 6 - Rack Page 2-9

2.1.2 Computer Floor Issues The weight of a fully populated BCS 4R bay may exceed 500 lbs. Each configuration will vary in weight depending on number and type of cards and cables used. Adding repeaters will increase weight. If bay weight exceeds the support capacity of your floor, computer floor supports may be required. 2.1.3 Required Tools and Equipment BNC crimpers for constructing BNC connector ends. Die sets required, depending on cable. BNC insertion tool, Telect PN 097197. 2.2 Inspection Compare the contents of the shipping container with the packing list. Call Telect or your distributor if you are missing anything. Telect is not liable for shipping damage. If the shipping container is damaged, keep it for the carrier s inspection. Notify the carrier and call Telect s Customer Service Department: 1-800-551-4567 or 1-509-926-6000 Keep the container until you have checked equipment operation. If you experience any kind of problem, call Telect s Customer Service Department. Use the original, undamaged container if you are instructed to return the BCS 4R component to Telect. Page 2-10

2.3 Installation 1. Mount the BCS 4R chassis, along with designation cards, to a rack, using the four supplied mounting screws (two per side). Torque to 35 in.-lbs (4.29 N m.). Figure 7 - Mounting Chassis to Rack 2. Install cable management rings on the rear rack flange using the hardware provided. 3. Repeat Steps 1 and 2 to install all BCS 4R chassis before installing power and I/O cables to any BCS 4R chassis in the rack. 4. For BCS 4R chassis that require power, route power from the power distribution panel to connectors on the rear of BCS 4R chassis. Use wire in the 10-22 AWG range. Strip away about 3 /8 in. (~10 mm) of insulation and then press in on the tab at the top of the connector to open the connector s jaws. Insert the wire below the tab and then release the tab to cinch the wire. Page 2-11

Figure 8 - Routing Power Page 2-12

5. Ground the chassis lug to the rack using #6- to #14-AWG stranded wire and a single-hole compression ring lug for a #8 stud. Figure 9 - Grounding the Chassis 6. Connect I/O cables to the rear of the chassis, as shown in the following illustration. In general, For network I/O cables originating overhead, start with the lowest BCS 4R chassis in the rack and work up. For network I/O cables originating from below, start with the highest chassis in the rack and work down. NE I/O cables connect to the lower I/O connectors on the chassis. Use a BNC insertion tool. Figure 10 - BNC Insertion Tool Page 2-13

7. Use cable ties liberally along the lower tie-down bar and tie-down lances (loops) at the rear of the chassis. 8. Insert cross-connecting cables to upper two connectors, labeled IX and OX on DSX cards. 9. If applicable, connect tracer wire to the port above the tracer LED, as shown. 10. Use cable ties along the upper tie-down bar to restrain the X-connect cables. Figure 11 - Connections Page 2-14

Figure 12 - Rear Cross-Connect Cables with Tracer Wire Page 2-15

This page intentionally left blank. Page 2-16

Chapter 3: Electrical Operation 3.1 Power The BCS 4R equipment is passive with the exception of the repeater and Vector OTM card modules. The DSX chassis accept -48V office battery power to light the tracer lamps (TL) LED on the front of DSX and repeater cards and LEDs on the rear of the chassis. Power connects to the Power/Alarm Terminal Strip on the back of each DSX chassis. The strip terminates a bus on the chassis backplane; all DSX card connectors on the backplane tap into the signal lines of this bus. Power for the rear TLs passes from the bus on the backplane, through the DSX card, to a small PCB also on the backplane. Power from Distribution Panel Tracer Lamp Figure 13 - Power from Distribution Panel to Front Tracer Lamp Page 3-17

3.1.1 Tracer Lamps (TL) The TL lights up when a plug is inserted into one of the monitor jacks on the front of a DSX card. Also, with the monitor plug in place, TLs of cross-connected cards will flash for 30 seconds, then light steadily. Batt A Rtn A Power from Backplane MON OX O I IX MON TL Tracer Wire Jack Backplane Tracer Lamp 3.1.2 Monitor Ports Figure 14 - Tracer Lamp Operation All DSX cards have at least one monitor port on the front side, labeled M or MON. Test equipment may be applied without interrupting service. The three-port card has a monitor for the OUT signal only. 3.2 DSX Cross-Connections Do not make rear cross-connections using cables longer than 27 ft, unless using a repeater card. Do not make front patch connections longer than 20 feet. 3.2.1 Backplane Cross-Connections To cross-connect two network elements, use approved coax cable and connect the OX (X-OUT) port from the card for network element 1 (NE-1) to the IX (X-IN) for network element 2 (NE-2), AND connect the OX port for NE-2 to the IX port from NE-1. See the diagrams below. Page 3-18

TL BATT A TL TRAC ER WIRE BATT A TL TL LED ASSEMBLY RTN A RTN A LED ASSEMBLY MON R2 R1=75 R1=75 R2=768 R2=768 R2 MON O X X-OUT X-OUT O X R1 R1 O O O O I R1 Network Element 1 I I Network Element 2 R1 I I X X-IN X-IN X I MON FRONT R2 REAR REAR R2 MON FRONT Figure 15 - Schematic Drawing of Cross-Connection Figure 16 - Rear Cross-Connect Cables with Tracer Wire Page 3-19

3.2.2 DSX Card Front Patch Install front patches to temporarily re-route signals. Patches with jacks labeled O,OX, I, IX are intrusive and interrupt service. Use 734A or 735A cable. Patch only to cards less than 20 feet away. Remove temporary patches in accordance with office procedures after permanent backplane cross-connections have been made. Figure 17 - Temporary Front Cross-Connect Using Patch Cables & DSX Cards Page 3-20

Chapter 4: Service 4.1 Owner Maintenance Telect s BCS 4R components do not need preventive maintenance. The only service you can perform is to replace these assemblies if they fail: DSX Card Module Repeater Card Module DNI Card Module Chassis Tracer lamp LEDs, on card and on backplane 4.2 Troubleshooting Cross-Connected Signals Check for correct and firm cable connections at the termination and cross-connect points on every card. 4.3 Replacing the Tracer Lamp LED Pull the LED assembly and plastic holder straight out. If LED polarization is not correct, the replacement will not work. Orient the new LED in the plastic holder the same as the original. The shape of the LED holder slot in the DSX module is keyed for proper LED insertion. 4.4 Service 4.4.1 In-Warranty Service Contact your Telect equipment distributor, or call a Telect Customer Service Representative: 1-800-551-4567 1-509-926-6000 Telect will repair or replace defective products within the limits of the warranty. See Repacking for Shipment in this section. Call a Customer Service Representative for a Return Material Authorization (RMA) before returning any equipment. Page 4-21

4.4.2 Out-Of-Warranty Service The procedure for out-of-warranty service is the same as for in-warranty service, except that Telect charges a processing fee, and you must submit a Purchase Order along with a Return Material Authorization (RMA) before returning equipment. Call a Customer Service Representative for help getting these forms. The processing fee guarantees a repair estimate and is credited against actual material and labor costs. 4.5 Repacking For Shipment Telect is not liable for shipping damage. 1. Tag the equipment showing owner s name, address, and telephone number, together with a detailed description of the problem. 2. Use the original shipping container if possible. If you do not have it, package the equipment in a way to prevent shipping damage. Include the RMA inside the container. 3. Insure the package. Page 4-22