Flow Cytometry. ZE5 Cell Analyzer. Superior performance and flexibility to align with your flow cytometry needs.

Similar documents
More results with advanced optics and superior electronics. Gallios Flow Cytometer

Bio-Rad Imaging Systems Family

Gallios. Flow Cytometry. Powerful Versatile Performance

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Optical Sampling Modules 80C01 80C02 80C07B 80C08C 80C10 80C11 80C12

Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

46 GBaud Multi-Format Optical Transmitter

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

Troubleshooting Analog to Digital Converter Offset using a Mixed Signal Oscilloscope APPLICATION NOTE

Live events staging. Media centers

CFlow User Guide. Science is hard. Flow cytometry should be easy.

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Low Cost, High Speed Spectrum Analyzers For RF Manufacturing APPLICATION NOTE

Installation Instructions. What This Option Provides

Logic Analyzer Triggering Techniques to Capture Elusive Problems

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Debugging Memory Interfaces using Visual Trigger on Tektronix Oscilloscopes

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Tektronix Logic Analyzer Probes P6900 Series Datasheet for DDR Memory Applications

Keysight Technologies ad Integrated RF Test Solution

Quick Signal Integrity Troubleshooting with Integrated Logic Analyzers & Oscilloscopes

Electrical Sampling Modules

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

STEVAL-ISA001V1. 6W Dual Output Supply using VIPer12A. Features. Blue angel. Applications

Virtual Graphics & Enhancements Virtual Advertising Insertion For All Sports VIRTUAL PLACEMENT PRODUCT INFORMATION SHEET

CyFlow Space Your flexible flow cytometer

Optical Sampling Modules 80C02 80C07B 80C08C 80C10 80C10B 80C11 80C12

Agilent M9362A-D01-F26 PXIe Quad Downconverter

On The Air. In The Air. On The Fly Live Graphics Telestrate Live Or Over Freeze-Frame HELIPAINT PRODUCT INFORMATION SHEET

InSight Pro. Valuable real-time process insight

Keysight Technologies Multi-Channel Audio Test using the Keysight U8903A Audio Analyzer

World s smallest 5MP stand-alone vision system. Powerful Cognex vision tool library including new PatMax RedLine and JavaScript support

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

CytoFLEX Flow Cytometer Quick Start Guide

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

Network Line Card Testing using the TDS3000B DPO Application Note. Line Card Testing Example: Throughput = Shippable Dollars

Automatic Changeover Unit ECO8000 Datasheet

Video Quality Monitors Sentry Edge II Datasheet

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

Checking the fluids of the cart

Standard Operating Procedure Of The CytoFLEX S Flow Cytometer At The Institute Of Virology

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Arbitrary Waveform Generators AWGSYNC01 Synchronization Hub Datasheet

VT5365. Single-chip optical mouse sensor for wireless applications. Features. Applications. Technical specifications. Description.

Arc Detecting and Protection System

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Keysight Technologies Intrinsic Contact Noise: A Figure of Merit for Identifying High Resolution AFMs. Application Note

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

BD FACSAria III User s Guide

FACSAria I Standard Operation Protocol Basic Operation

Automatic Changeover Unit ECO8020 Datasheet

Advanced Test Equipment Rentals ATEC (2832)

Guide to the FACS Calibur

Video Reference Timing with Tektronix Signal Generators

X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination

Black and Frozen Frame Detection

FAST MOBILITY PARTICLE SIZER SPECTROMETER MODEL 3091

OSICS 8-Channel Modular Platform for DWDM Testing

Automated Limit Testing

Agilent N4876A 28 Gb/s Multiplexer 2:1

Analysis and sorting of cells with FACSAria II flow cytometer Tiina Pessa-Morikawa / Revised

ABB MEASUREMENT & ANALYTICS. MB3000 The most reliable FT-IR laboratory analyzer

Exceptional performance

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

ABB MEASUREMENT & ANALYTICS. MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC

STANC0. Stereo HD-PA digitally programmable active noise cancelling audio engine. Features. System. Input and output.

Boosting Performance Oscilloscope Versatility, Scalability

Agilent Series Harmonic Mixers

Limit and Mask Test Application Module

NOTES ON FACSCalibur USE AND TROUBLESHOOTING PROCEDURES. Department of Immunology Monash University 14/12/07

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Arc-fault Protection System

Video Quality Monitors

Instructions for Use. CytoFLEX. Flow Cytometer. B49006AE November Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA U.S.A.

Keysight Technologies

Unity Interlaboratory Reports

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Datasheet. High-Performance airmax Bridge. Models: NBE M5-19, NBE-M5-16. Uniform Beamwidth Maximizes Noise Immunity. Innovative Mechanical Design

Video Digital Optical Converter

Very low-noise, high-efficiency DC-DC conversion circuit

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Agilent N5183A MXG Microwave Signal Generator

Agilent Migration from 8712/8714 Series to ENA-L Network Analyzers

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Thermo Scientific Polar Series Cooling/Heating Recirculating Chillers

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Operation of the ACEA NovoCyte Flow Cytometer

RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes

How-To Guide. LQV (Luminance Qualified Vector) Measurements with the WFM8200/8300

Tektronix Video Signal Generators

Video Quality Monitors Sentry Edge Datasheet

Dell Wyse 5030 PCoIP Zero Client

Transcription:

Flow Cytometry ZE5 Cell Analyzer Superior performance and flexibility to align with your flow cytometry needs.

We wanted a compact, easy, and flexible machine that could produce formidably complex data very quickly and with no behind-the-scenes losses. Karen Helm, Flow Cytometry Core Manager, University of Colorado Cancer Center When Bio-Rad Laboratories and Propel Labs set out to design the next cell analyzer for research applications, we turned to the most demanding users we could find flow core managers and directors. We asked them how we could make their work easier and what functionalities a cell analyzer needed to have to advance the research of their flow core users. Their responses directly resulted in the ZE5 Cell Analyzer. Designed by Users for Users

Quite possibly the only cell analyzer you will ever need The ZE5 Cell Analyzer provides the speed and flexibility to optimize your flow cytometry lab. It will change how cutting edge labs like yours operate. Up to five lasers and 30 detectors allow your lab to run any panel you need. It integrates a universal plate loader that seamlessly accepts single tubes, tube racks, or 96- and 384-well plates so it s ready for any sample with no hardware change or additional equipment needed. With its highly precise sample pump, 96-well plates can be run in less than 12 minutes, generating more data in less time. Easy-to-learn and -use software and proprietary features like the ZE5-EYE lessen the burden of training and monitoring users, prevent costly errors, and give you peace of mind even when multiple users access the optical filters. The ZE5 Cell Analyzer was designed with an understanding of the importance of your samples and time. Exceptional electronics and optics that you can trust with your most critical experiments generate the highest quality data. Power your research with the ability to run high complexity samples up to 5 spatially separated lasers and 30 independent detectors Enjoy the simplicity, for even the most novice user easy setup of experiments with Everest Software and the spectral viewer Easily switch between tube, rack, or plates with no hardware changes universal integrated sample loader with sample mixing and temperature control Maximize reagent and sample usage unused sample can be returned to tube or wells for further analysis 4 ZE5 Cell Analyzer

Give us the ultimate plate sampler fast and flexible. Oh, and a tube rack too. It is all right here Just like your experiment, the design for the ZE5 Cell Analyzer began with your sample. You wanted one system that could handle all of your sample vessels. And you wanted it as a primary consideration, not an afterthought. You wanted to focus on your science and not on plumbing instruments or integrating complicated accessories. These are at the heart of ZE5. The ultimate flexibility in sample handling ready for anything The ZE5 Cell Analyzer has a universal loader that can handle any format of tube, plate, or well. The loader is fully integrated and built in, so there is no labor-intensive hardware change and you can switch from plates to tubes to tube racks, or even run a single tube, with no effort. Integrated plate loader with adjustable orbital vortex plate shaker Single 5 ml tubes, 40 x 5 ml tube racks, 24 x 1.5 ml tube racks, or shallow or deep 96-well and 384-well plates 4 37 C active temperature regulation Flying collar wash Probe crash detection Analysis of completed wells/tubes while still acquiring Bio-Rad Laboratories, Inc. 5

Could they design an instrument that would warn us about some of those snags we hit every day? Preserve your precious samples Samples are precious, and you need to maintain their integrity. The ZE5 Cell Analyzer uses a combination of speed, automation, and innovative design to protect your samples. Use high-throughput mode to analyze a 96-well plate in less than 12 minutes. Time-specific delivery to the sample allows you to add reagents during a run without needing to start and stop and start again. With active temperature control to warm and cool samples, with no dead volume requirement, and with the ability to return unused sample volume back to your tube or plate well, your samples stay safe. The dual peristaltic pump has an inside-out design that requires less sample volume, reduces risk of contamination, and allows for continuous bidirectional running and volumetric sample handling. Two sets of offset rollers pressurize the sample before it is injected into the flow cell, resulting in similar pressure and reduced pulsation for an even sample flow. Never worry about probe crashes again The ZE5 Cell Analyzer offers two levels of built-in probe crash avoidance. It prevents any plate agitation until the wash station is lowered and the probe is safely encapsulated. During a run, the ZE5 Cell Analyzer uses a gentle gravity method to protect from probe crashes. If any resistance is detected on the probe, it automatically stops and alerts the user, avoiding probe damage. 6 ZE5 Cell Analyzer

High-velocity flow cell The flow cell operates at 8 m/sec, twice the stream velocity of other systems, and analyzes twice the amount of sample at any given concentration. Maintains a small sample core with low CVs Provides higher resolution data in less time Matched to system components for thermal expansion for excellent stability Allows a broad range of sample flow with 10 psi sheath pressure State-of-the-art lasers and optics The ZE5 Cell Analyzer optical bench was specifically designed to give you the highest resolution data. Each PMT is placed an equal distance from the flow cell so optimal light can be achieved at all wavelengths without compromise. Shortest path to the flow cell Custom designed steering mirrors Integrated beam shaping prisms requiring no adjustment Liquid-cooled lasers to maintain optimal temperature for beam pointing stability Increased excitation beam stability for better day-to-day data Identical distance of each detector from flow cell and focusing lens Superior sensitivity with optimal focus for all photomultiplier tubes (PMTs) High-performance Hamamatsu H11903 PMTs Up to five lasers can be accommodated. Bio-Rad Laboratories, Inc. 7

Low noise electronics 120,000 Get the most out of your data High-speed acquisition with no aborts No dead time Dynamic window extension Real-time hardware execution of run list Fully reprogrammable for future features and changes Completely flexible for additions Low noise electronics reduce noise on dim signals Measure count, sec 100,000 80,000 60,000 40,000 20,000 0 0 20,000 40,000 60,000 80,000 100,000 120,000 Expected count, sec This graph shows the acquisition speed capabilities of the ZE5. Dragon Green Beads (Bangs Laboratories, Inc.) were used in a serial dilution to determine when the observed acquisition rate falls off the theoretical limit. The ZE5 outperforms other systems at higher acquisition speeds as it continues to acquire data into the 100,000 events per second range whereas the other systems fall off around 20,000 events per second. ZE5 Cell Analyzer ( ); Cytometer 1 ( ); Cytometer 2 ( ); Cytometer 3 ( ). An optical filter layout with consistent path lengths yields optimal detection and sensitivity for all wavelengths at each detector. 8 ZE5 Cell Analyzer

Change that sheath tank on the fly. Get up and running fast, stay up and running Instrument fluidics onboard Hot swappable sheath and waste tanks with indicator lights Sheath additive bottle onboard Cleaning solution onboard Direct connection to laboratory DI water supply and waste Best-in-class fluidics High-pressure operation at 10 psi Stable delivery and waste evacuation Monitored sheath and air consumption to verify operation Very quiet and low vibration The ZE5 comes with two sets of sheath and waste tanks that are hot-swappable anytime one set is used up. The tanks are driven by a low vibration, high-pressure fluidics module that provides uninterrupted operation throughout the day. Bio-Rad Laboratories, Inc. 9

Tell me that my filter configuration change probably won t work. ZE5-EYE: Worry-free operation for the busy core lab The ZE5-EYE runs an automated check before each run of all PMT filter spots to ensure that no filters have been removed or placed in the wrong spot. A dedicated electronics board implemented as part of the detection path uses ten distinct wavelengths of LEDs that cover the expected spectrum of light to ensure that the correct light is being passed to each PMT filter slot. The innovative ZE5-EYE checks the entire detection path, including the pinhole, filters, PMTs, and electronics, and alerts the user through the software of any issues before starting each run. This eliminates the possibility of misplaced filters and cuts troubleshooting time in half. The ZE5 Cell Analyzer also keeps track of your settings, alerts you to any changes, and warns you if a critical parameter has changed. Ready reagents for your success To make life even easier, the ZE5 Cell Analyzer and Bio-Rad s fluorescence-based reagents and antibodies have been tested to perform well and ensure your experiment s success. The integrated Everest Software comes preloaded with the spectra of Bio-Rad s flow cytometry products, providing a quick and easy way to start an assay. Thousands of antibodyfluorophore conjugates and their corresponding isotype controls are available for the ZE5 Cell Analyzer, allowing you to design multicolor panels for immunophenotyping and make full use of the 30-detector capability of the instrument. In addition, ready-made apoptosis, cell proliferation, and cell viability kits are available and take advantage of the high sensitivity of the ZE5 instrument. 10 LEDs directed through the entire optical pathway to the PMTs 10 unique wavelengths from <400 to >800 nm Individual LED control Identification of unique signature for each PMT s optical filter Help troubleshooting A series of LEDs of different wavelengths illuminate the light path. The amount of light reaching each PMT from the different wavelength LEDs is determined by the filters that are in place. The detected PMT signal is compared to a reference to determine whether the expected filter set is in place. If the signals do not match, a warning will be displayed at the relevant PMT(s). Resources Webinars Cell marker selection guide Mouse and human Antibodies Application guides ELISA, IHC, Western blotting In-depth mini-reviews Research focused posters Research areaa antibodies Cancer Immunology Veterinary No experiment is complete without all the pieces 10 ZE5 Cell Analyzer

Let me turn it on and off automatically while I m on vacation. Everest Software is revolutionary flow cytometry software that is pushing boundaries Automation Eliminates mundane tasks such as startup and shutdown by automating and allowing for programmable scheduling Onboard QC beads allow the system to complete QC before you walk up to the ZE5 Analyzer The Fluorochrome Selector assists with experimental design and work list setup Analysis Acquire and store files with up to 100 million events with all parameters enabled at high speed, reducing rare event detection time Features such as multichannel triggering and the heat map provide an extra edge in analysis of complex experiments Analyze saved files while acquiring new data to improve your workflow and experimental efficiency A report function takes your analysis to a reports page, where you can refine and add notes for your audience of choice Bio-Rad Laboratories, Inc. 11

Specifications System Fluorescence sensitivity Scatter sensitivity Loader Throughput Optics Excitation Detection Cuvette Electronics Speed Data processing Fluidics Sample flow rates Bulk fluids Installation Power Dimensions (W x D x H) Weight Temperature and humidity Air and vacuum supply Software Flow Cytometry Standard (FCS) format QC Acquisition and analysis Workstation Dell Precision Workstation Processor Operating system Language pack Graphics Memory Networking Monitor SSD Boot Drive HDD Data Drive Regulatory Compliance Regulation <100 MESF for FITC, PE, APC <0.3 µm FSC resolution with small particle detection module Integrated sample loader with agitation and temperature control. Up to 384-well plates; 40-tube rack for 5 ml 12 x 75 mm tube loading. Stat tube position for single 5 ml tube loading <12 min for 96-well plate in high-throughput mode Up to five spatially separated lasers. Standard options include: 355 nm, 50 mw 488 nm, 100 mw 640 nm, 100 mw 405 nm, 100 mw 561 nm, 50 mw Up to 30 detectors, including FSC and SSC; optional second FSC detector Fused silica with 145 x 265 µm channel >100,000 events per second with all parameters enabled Simultaneous measured peak, area, and width for every channel. 24-bit data for peak and area. 17-bit data for width with high-resolution linear interpolation at the half height 0.0025 3.5 µl/sec 4 x 4 L bulk fluid tanks on board for sheath and waste. Onboard additive concentrate and cleaner 100 240 VAC, 50/60 Hz 29 x 27 x 26 in.; 74 x 69 x 66 cm <240 lbs; <110 kg 18 28 C; 20 60% RH Included, onboard FCS 3.1 Automated quality control with onboard calibration beads Everest Software Intel Core i7-7700 (Quad Core, 3.6 GHz, 4.2 GHz Turbo, 8 MB) Windows 10 Pro English Intel 630 integrated DDR4; 32 GB RAM Intel Gigabit LAN 29" w/ speakers 256 GB 4 TB CE, Class I (1) laser product Research use only Dell Precision is a trademark of Dell Inc. Hamamatsu is a trademark of Hamamatsu Photonics K.K. Corporation. Intel and Intel Core are trademarks of Intel Corporation. Windows is a trademark of Microsoft Corporation. Bio-Rad Laboratories, Inc. Life Science Group Web site bio-rad.com USA 1 800 424 6723 Australia 61 2 9914 2800 Austria 43 1 877 89 01 177 Belgium 32 (0)3 710 53 00 Brazil 55 11 3065 7550 Canada 1 905 364 3435 China 86 21 6169 8500 Czech Republic 420 241 430 532 Denmark 45 44 52 10 00 Finland 358 09 804 22 00 France 33 01 47 95 69 65 Germany 49 89 31 884 0 Hong Kong 852 2789 3300 Hungary 36 1 459 6100 India 91 124 4029300 Israel 972 03 963 6050 Italy 39 02 216091 Japan 81 3 6361 7000 Korea 82 2 3473 4460 Mexico 52 555 488 7670 The Netherlands 31 (0)318 540 666 New Zealand 64 9 415 2280 Norway 47 23 38 41 30 Poland 48 22 331 99 99 Portugal 351 21 472 7700 Russia 7 495 721 14 04 Singapore 65 6415 3188 South Africa 27 (0) 861 246 723 Spain 34 91 590 5200 Sweden 46 08 555 12700 Switzerland 41 026 674 55 05 Taiwan 886 2 2578 7189 Thailand 66 2 651 8311 United Arab Emirates 971 4 8187300 United Kingdom 44 020 8328 2000 Bulletin 6814 Ver B US/EG 16-1157 0217 Sig 1216