Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

Similar documents
ROSE THEATRE BASEMENT

The Night Club. MASKING Proscenium with SR split and SL Step unit to the ground level for entrances. Limited SR wing space. No crossover possible

ROSE THEATRE MAIN THEATRE

THE DINING ROOM SEATING 120 STAGE 6m wide by 4.5m deep MASKING SUSPENSION 3710mm

DEREHAM MEMORIAL HALL

The Standard Bank Studio is a music venue made from the choir stalls and the stage of the Cape Town City Hall Auditorium. It

Main House Technical Specification

Gilded Balloon s Basement Theatre is a brand new 120 capacity theatre space in the heart of Edinburgh s West End.

JERWOOD VANBRUGH THEATRE

Technical requirements & conditions for hirers

New Theatre Royal Lincoln Technical Information

THE DEBATING HALL. There is no crossover behind the stage but it is possible to cross around the house to make an entrance

Main House Technical Specifications

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

DOMINO THEATRE INC. THEATRE TECHNICAL SPECIFICATIONS AND INFORMATION

Technical Pack. Attenborough Arts Centre

COURTYARD!!!!! THEATRE

Theatre Royal Pre-Production Requirements

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

Barney Simon Theatre Technical Specifications

Pleasance London Main House Visiting Company Information Pack May 2017

Matthew Flinders Theatre

The Mannie Manim Technical Specifications

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

The Lantern Technical Information

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Studio 180. Electronic and Print versions of the venue ground plan are available from the Technical Director.

DANCE BASE TECHNICAL SPECIFICATION

Technical Specification

ISLAND HALL TECHNICAL INFORMATION

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Faris Family Studio at the Dance Centre, Vancouver BC 677 Davie Street, Vancouver, British Columbia. V6B 2G6

TECHNICAL INFORMATION

2017 TECHNICAL SPECIFICATIONS

STUDENT PRODUCTION JOBS

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

The Haymarket Basingstoke Technical Specifications

HIRE AND TECHNICAL INFORMATION

Lighthouse Theatre Technical Specification

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

Matt Dann Cultural Centre

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

HUECO / Technical Rider

P90 Technical Specifications &

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

RPAC REDLANDS PERFORMING ARTS CENTRE

TECHNICAL SPECIFICATIONS

INFORMATION FOR VISITING COMPANIES

Theatre Technical Specifications

CONTACTS Jani Lauzon Managing Artistic Director

Hopgood Theatre NOARLUNGA CENTRE

WHO WE ARE As a home is not just a house, a Theatre is not just a space.

INFORMATION PACK & SCHEDULE OF RATES 2015

PSYCHIC SALLY PRODUCTION RIDER & FOH REQUESTS (UPDATED 2016)

MAJESTIC (Circus Tent)

Marjorie S. Deane Little Theater

Technical Specification Pavilion Dance

P90 Technical Specifications &

The Breen Center for the Performing Arts Saint Ignatius High School

Dr. Fred Speckeen Theatre. Information and Technical Specifications

the CenterStage Policies & Procedures

MAJESTIC (Circus Tent)

Divadlo Kampa (di-vad-lo Kam-pa)

Technical Specifications Updated 01/10/2017. Stage

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

THE STREET THEATRE. Technical Specifications

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

WHO WE ARE As a home is not just a house, a Theatre is not just a space.

STAGE MANAGER JOB DESCRIPTION & DUTIES

National Folk Festival PA Specs 2018 MARQUEE

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Facility Information

Downtown Arts Center Tech Packet. General Information

TECHNICAL RIDER GENERAL INFORMATION

Shouson Theatre Venue Specifications (updated Jan 2017)

TECHNICAL RIDER. If you have problems to fulfil some of our demands, please don t hesitate to contact us. We will find a solution!

WHO WE ARE As a home is not just a house, a Theatre is not just a space.

Dr JOHN GALLAGHER CONCERT CHAMBER

TECHNICAL REQUIREMENTS

Avant Garde Dance & The Place Fagin s Twist Tech Spec 2016

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Technical Services and Specification

Technical Rider. Update: may 6th 2008

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Information for Incoming Companies

Technical Rider. Ryan McFarling Illusionist. General Stage Requirements

GENERAL INFORMATION FOR HIRERS

Dance floor surface: Black marley dance floor on a sprung stage floor.

Little River Band Production Rider 2018

IDEAL BAR. General information Technical specifications Production information

TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem,

SHUT DOWN FILM INSTALLATION TECHNICAL SPECIFICATION

2012 HSC Entertainment Industry Sample Answers

REHEARSAL ROOM 2 CURVE TECHNICAL SPECIFICATIONS & EQUIPMENT LISTS Updated October 2011 Contact details

THE ROUNDHOUSE THEATRE

Transcription:

Capacity: 60 2 Roxburgh Place, EH8 9SU Assembly Roxy - Downstairs

Schedule C Outline description of the stage and technical facilities provided by Assembly. 1. SEATING is an end on theatre space with a raked auditorium of 60 seats. 2. THE STAGE The performance area is 5m wide by 3m and is covered in black dance floor. The stage is raised 90mm above floor level. There is no backstage area. There is no crossover available. It is not permissible to screw into the venue floors and walls. 3. MASKING Black Box, no wing space and no crossover. 4. SUSPENSION The underside of the grid is at 4.4m from the stage There are no flying facilities Lightweight items of scenery may be hung from the grid on single lines at the discretion of the Technical Manager 5. LIGHTING The lighting and sound control positions are located together at the rear left of the auditorium, it may be possible for one person to operate. Equipment CONTROL: Jester ML48 DIMMERS: 18 x 10Amp Power supply maximum load: 10 kw A good general cover of warm and cool light over the performance area is provided. The position and focus of these lanterns may not be changed, however they may be coloured for your show, provided this is possible within your set-up and strike time. Additional lanterns can be rigged as company specials but must come from the stock of Assembly Theatre s supplier. These units will be charged as an additional cost. Blackout on stage is acceptable; however, absolute blackout is not possible due to emergency lighting regulations. We do not allow companies to bring their own lights. For the most up to date plans and technical specifications, please liaise with the Head of Lighting in the lead up to the festival. Please note these specifications are subject to change.

6. SOUND The lighting and sound control positions are located together at the rear left of the auditorium, it may be possible for one person to operate. We do not allow companies to bring their own sound equipment. System : d&b E series L&R system plans available on request. Monitors: 2 x floor monitors are available FOH Desk: Yamaha LS9 16 Input Digital Console with on board processing and effects FOH Playback 1: 1 x 3.5mm Jack inputs FOH Playback 2: 1 x Dedicated computer with sound replay/cue software The basic rig also includes 2 wired dynamic SM58 microphones and 2 DI boxes. For information and costs for radio microphones please contact the Head of Sound. Additional microphones, other sound equipment and backline equipment is available for hire. This equipment is provided by Assembly Theatre s supplier and will be charged as an additional cost details on request. All sound equipment must be agreed in advance with the Head of Sound or the Technical Manager. 7. DRESSING ROOM This is shared by all companies performing in the venue and is located to the rear of the venue separated from the theatre by a standard sized single door. Tables, chairs and mirrors are provided for communal use. The management cannot accept responsibility for the security of any items left in the dressing room. You will have access to the storage and dressing room 40 minutes before and for 20 minutes after your performance each day. 8. STORAGE There is no backstage storage area; any props will be stored in the dressing room and we recommend that companies keep their scenery/props requirements to an absolute minimum. It is not possible to provide storage space in other parts of the building. It is worth ensuring that your set is light yet durable enough to withstand daily dismantling. ALL SET ITEMS ARE REQUIRED TO EASILY PASS THROUGH A STANDARD DOOR 97cm wide x 2m high 9. ACCESS DOWNSTAIRS is located in the Assembly Roxy: 2 Roxburgh Place Edinburgh EH8 9SU Access to the stage is from an internal stair case. There is one audience entrance/exit, from the rear of the auditorium, this must be kept clear as emergency exit. The venue is on the lower ground floor with access from the street by way of a staircase. Load in and out is via the main entrance and standard width door of max 1.1m

10. STAFF The theatre personnel work on a rota basis, the duty rota comprises one technician. If the visiting manager requires additional staff to assist with the turn around, or the use of casual crew during the load in or load out, this can be arranged at additional cost. If the venue technical staff are required to participate for anything more than lights up /lights down (one cue to bring the house to a performance state and mic live and then one cue to bring the house back to exit state) during the performance, the Visiting Company will be liable for a show call charge for each technician used. The rate is 20 per performance per technician plus VAT. 11. NOTES Any additional staff or items of equipment, which the management are requested to provide, will be charged to the visiting company. Any practical electrical equipment you wish to use should have a current PAT certificate and be cleared with us. We reserve the right to refuse the use of any equipment which is deemed unsafe. Each company is assigned a get in/rehearsal time prior to their first performance This is the time for you to load your set and props into the venue and for you to re-tech your show. You will also need to allow sufficient time to rehearse your daily turnaround and set storage. Please note that your slot time must include get-in and get-out time. Please note that, due to the Scottish Executive regulations, smoking is not permitted in any venues, including the use of herbal cigarettes. Only electronic cigarettes may be used. At the end of the festival, please arrange for removal or disposal of your set and any unused publicity material. There will be a charge applied to cover the cost of disposal should you not comply with this request. Please note, since this is a temporary conversion and not a permanent theatre, all measurement and quantities quoted in the above specification are approximate and may be subject to change. For detailed and up to date information regarding the venue please contact the Technical Manager technical@assemblyfestival.com.

assembly 2013 Plan & Elevation 5000 Initial Plans - SUBJECT TO CHANGE 11/4/13 Note: 3000 4375 4465 7516 technical@assemblyfestival.com

Steve Steve Shelley Shelley 2003 2003 1 2 3 4 5 6 drawing no Instruments 7 RDLXFR13 revision sheet size 1 A4 legend Used A S4 PARNel 8 A 22 23 24 25-50 S4 Jr Zoom 1 Aisle Light 2 PixPar12 5 Coda 500 1 B 21 25 Legend B Color Gobo 1 Channel Purpose C C 3 7 4 8 All fixtures outrigged on truss LIGHTING CONTROL Zero88 Jester ML48 DIMMERS 18 channels (9 ch allocated to Fixed Rig) notes D D E 1 5 Steve Steve Shelley Shelley 2003 2003 25-50 9 2 6 NOTE: Lighting fixtures & plan are subject to change. For most up to date plan, please contact Assembly Head of Lighting. client project venue title designer drawn information Assembly Edinburgh Festival Fringe 2013 Lighting Fixed Rig - PL scale date 1:50 2013-04-11 E 1 2 3 4 5 6 Assembly Festival 2/2 50 George St Edinburgh EH2 2LE T. +44 (0) 131 623 3000 F. +44 (0) 131 623 3001 http://www.assemblyfestival.com Assembly Media Group Ltd 7