Patrick Rushing GUEST Production Office Numbers (cell)

Similar documents
TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Bloomington Center for the Performing Arts. Technical Specifications

Technical Specifications

Technical Information

Technical Specifications. Taylor Little Theater

FOX THEATRE ST. LOUIS

SHUBERT THEATER 247 College Street, New Haven, CT

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Technical Specifications

Dr JOHN GALLAGHER CONCERT CHAMBER

Technical Specifications

TECHNICAL PACKAGE.

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Main Stage Technical Specs - Hall #2

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Sandusky State Theatre Technical Specifications

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Downtown Arts Center Tech Packet. General Information

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

SHOWBOX SODO TECHNICAL SPECIFICATIONS

Performing Arts Theatre

Marjorie S. Deane Little Theater

Technical Information

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Technical Services and Specification

Technical Specification

Concert Hall Technical Specifications

Technical Specifications and Inventory Spring 2018

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Main House Technical Specification

Facility Information

General & Technical Specifications

Little River Band Production Rider 2018

Meadow Brook Music Festival 3554 Walton Blvd Rochester Hills, MI Tech Pack

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

Camden Opera House Theater. Technical Information

Technical Specifications

UNIVERSITY CONCERT HALL. Technical Specification

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Dale F. Halton Theater Technical Specifications

Hard Rock Cafe Times Square Sound System Advance Sheet

Concert Hall Technical Specifications

Technical Specifications

Patriots Theater at the War Memorial Technical Data

NORTH CHARLESTON PERFORMING ARTS

THE BELDING THEATER. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Latrobe Performing Arts Centre

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

PRODUCTION PHONE NUMBERS:

Barbican Concert Hall Sound System Spec

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

SECREST AUDITORIUM TECHNICAL PACKAGE

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

111 North 5 th Street Minneapolis, MN 55403

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

Ferst Center for the Arts Technical Specifications (Revised May 2016)

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

PRODUCTION INFORMATION

Technical Informa on.zack Theater

Quick-Advance Fact Sheet

Technical Specifications

Palace Theatre 61 Atlantic Street Stamford, Connecticut

Technical Specifications

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

P.O Box 1171 Box Office & Theatre: (903) Main St Texarkana, TX TRAHC Office: (903) Texarkana, TX Fax: (903)

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Paramount Theatre Production Recap

Arcadia Performing Arts Center Technical Specifications and Information

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

TECHNICAL SPECIFICATIONS AND INVENTORY PANTAGES THEATER

SAINT ANSELM COLLEGE DANA CENTER

Theatre Technical Specification

The ACT Facility Technical Specifications Main Stage Information

Technical Specification Pavilion Dance

Clayton Center for the Arts Ronald and Lynda Nutt Theater Technical Specifications December 2014

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Matt Dann Cultural Centre

THE CLASSIC GRAND 18 JAMAICA STREET GLASGOW G1 4QD

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

NORTH CHARLESTON PERFORMING ARTS

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

THEATRE EQUIPMENT DECEMBER 2017

2017 TECHNICAL SPECIFICATIONS

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

ARTPARK MAINSTAGE THEATER TECHNICAL PACKET

NORTH CHARLESTON PERFORMING ARTS

The Breen Center for the Performing Arts Saint Ignatius High School

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

Transcription:

TECH PACK HOUSE Production Office Phone Number Production Manager 313-963-0010 Patrick Rushing GUEST Production Office Numbers 313-575-4836 (cell) 313-963-5807 patrickrushing@livenation.com 313-963-5478 There is one guest production office off upstage right. Approx: 10 x7. The Room contains 2 working countertop spaces. There is also a small bathroom and shower connected to the Backstage Guest Production Office. STAGE DIMENSIONS Ante-proscenium width: 47 2 Proscenium width: 50 0 Wall to Wall: 86 9 Stage Floor Tongue & Groove Firm Proscenium to fly rail: 7 6 Lambrequin Trim 27 4 From Fire Curtain to back wall 25 4 Apron Depth 28 0 Stage Depth 25 5 Orchestra Pit 47 2 W x 14 11 D at Center Usable wing space SR from Proscenium to fly rail 7 6 Usable wing space SL from Proscenium to wall columns 21 11 ELEVATOR PIT Maximum Height Even with Stage Minimum Height 6 8 ½ Below Stage Level Basement level access is from a door center stage in the trap room LOADING DOOR Loading Door Size 10 W x 12 H Door is down stage left leading to an alley and parking lot. The Door is 30 above stage level Loading Door Ramps 37 x 10 Fiberglass split ramp 14 Aluminum Ramp LOADING TO BASEMENT & DRESSING ROOMS 1 Ton chain hoist can be made available for loading to dressing rooms via 47 x62 trunk doors. A trap door to the basement upstage right allows loading to the trap room, etc. No backstage elevator is available.

RIGGING Fly rail system is located Stage Right at Stage Level Number of system Pipes 46 Proscenium to first usable set: #02 12 ½ Proscenium to last usable set: #42 23 1 Last usable set to back wall: 3 Stage floor to grid: 75 Grid to loading platform: 37 Lines per pipe: 4 ¼ on 15 2 centers Length of pipes: 55 min PIPE SPECIFICATIONS PIPE SIZE LOAD ARBOR HEIGHT LBS./CAPACITY 1 3.5 Dead -- -- 2 12.5 Burgundy Boarder 5 400 3 2 3 Video Screen 9 800 4 2 7.5 DS Legs 5 400 5 3 3.5 Grand Drape 7 600 6 4 Grand Drape 5 400 7 4 4 Movie Screen 9 400 8 4 11 Movie Screen 5 400 9 5 6 Open 10 6 7 Open 11 6 11 Open 12 6 11.5 Open 13 7 4 Open 14 7 8.5 Open 15 8 6 Open 16 8 10.5 Open 17 9 8.5 Open 18 10 2 Open 19 10 8.5 Mid Legs 5 400 20 11 10 ¾ Black 5 400 21 12 6.5 ½ Black 5 400 22 13 1 Open 5 400 23 13 7 Open 5 400 24 14 1 Open 5 400 25 14 7.5 Open 5 400 26 15 Open 7 600 27 15 6.5 Open 5 400 28 16 7 Open 5 400 29 17 1 ½ Black 5 400 30 17 7 Open 5 400 31 18 1 Open 5 400 32 18 7.5 Upstage Legs 7 600 33 19 1 Work Lights 5 400 34 19 7 Open 5 400 35 20 1 ½ Black 5 400 36 20 7.5 Open 5 400 37 21 2.5 Open 5 400 38 21 8.5 ¼ Black 5 400 39 22 Open 5 400 40 22 4.5 Dead 5 400 41 22 8 Open 5 400 42 23 1 Open 5 400 43 23 4.5 White Cyc 5 400 44 23 10 Open 5 400 45 23 10 Tabs 5 400 46 24 6.5 Full Black 5 400 *There are open upstage and midstage fly poles available for drops *NOTE: All drops, drapery, skirting or props must be flame proofed/retarded with a Certificate of Flame Proofing

STAGE SOFT GOODS Burgundy fixed Valance Burgundy fixed Border Burgundy Border (downstage of G.D.) Burgundy Grand Traveler (Approx: 4 ft. Upstage of the downstage edge) Downstage, midstage and upstage black legs Full upstage black One set of black side tabs (offstage left and right) LIGHTING SPECIFICTIONS Lighting Console - Leprecon 2000. 2/scene (x & y) 48 channel w/ Soft patch access. - 8 Rolling pages of 24 presets - 8 Chase presets - All channels have momentary and solo bump buttons - NSI MLC 17 moving light console House Spotlights - (2) Lycian 1290 XLT 2K (Located in projection booth above balcony) 1-30A circuit each - (2) Lycian 1.2K long throw (Located in lower corners of the balcony) 1-30A double pull circuit each - CLEAR COM hard line runs from stage to the FOH booth and all spot positions House Lighting - The Upstage truss is 40 with (52) par 64-1k cans and (6) 6 x 9 lekos, (3)-ACL racks, (6) Robe Colorspot 250XT s, (5) - Dataflash 1000 s - Located 22 from downstage edge - House light controls are located Backstage and stage right - The Downstage FOH truss is 30 with (24) par 64-1k cans and (8) source 4 lekos - There are (2) mole fayes and (4) 2K fresnels - (2) Robe colorspot 250 s for floor or top of PA stacks - Located 13 6 from downstage edge Other Risers - (1) Lemaitre H175 Hazer - (3) - 8 x 8 s -(1) w/ 12 legs or 2 6-4 legs, (1)- w/ 1 6 legs, (1)- w/ 2 6-3 6 legs

ELECTRIC Company Switches: - (1) 600 amp 3/ phase 120/208v. Total load not to exceed 600 amps per leg Located Stage Right Basement - (1) 100 amp 2/ phase 120v w/isolated ground. Located Stage Right Basement - (1) 200 amp 3/ phase 120/208v. Located Stage Left Basement. - 35 of cable minimum is required to make hook up to switches for each side respectively F.O.H. Positions: - Balcony Rail: 59 from proscenium at center at 15 Degree angle. 40 pipe - Projection Booth: 139 from proscenium at center at 25 Degree angle. - Booth Power: 70A 120/240v HOUSE P.A. & SOUND EQUIPMENT STANDS (Round Base) MICS TALL 14 (10/4) SM 58 s 3 SHORT 6 (5/1) PM 52 1 BOOM ARMS 16 (12/4) PM 56-4 TRIPOD PM 81-2 TALL 4 (2, 2) SHORT 1 CABLES 40 CH FOH Snake W/Monitor Split XLR 36 / 50 FT 2 / 100 + FT. 4 NEUTRIK - (NL4) 75 ft / 2 / 50 ft / 2 / 25 ft 7 / Jumpers 9 (NL8) 50 FT 1 COUPLERS - NL4 5 / NL8 1 SUB SNAKES - 1-12 Ch UPSC / 1 9 Ch FLOAT / 1 9 Ch SR AMP Rack Top Bottom SF s SR 1/1 SL 1/1 (NEXO/E-Line) NEXO B-1 18 WEDGES 6 (15 x 2 ) 2 K.T. DN 300 EQ s (NEXO NX 242 PROCESSOR) 1 Stereo SF Mixes (1 Macro Tech 3600 VZ ) (1 Macro Tech 5002 VZ) 3 Wedge Mixes 1 RANE AC22 X-over

40 Ch. FOH Board Midas Verona - 40 x 8 x 4 32 CH Monitor Board Midas Venice NEXO ALPHA P.A. 6 M3 Boxes / Side 2 NEXO Proc./Side NX 242 8 B1 Boxes / Side 3 CD18 Boxes / SideCrown Powered 2 Macro Tech / Side - 3600 VZ 4 Macro Tech / Side - 5002 CROWN POWERED 2 Macro Tech 24 x 6 2 Macro Tech 1200 2 White 4856 EQ s FOH OUTBOARD GEAR/EQUIPMENT 1 - KLARK TEKNIK DN360 EQ 1 - RANE GQ 30 EQ 1 - YAMAHA REV-7 1 - YAMAHA SPX-900 2 K.T. DN504 COMPS 2 JBL MG44 GATES 1 TASCAM CD A500 CD/CASS 1 JBL M712 COMPS 1 DBX 481 DRIVE RACK STATE BAR 4 NEXO PS10 2 NEX0 LS500 SUBS 1 NEXO PS1- PROCESSOR 1 CROWN MACRO TECH 1200 1 CROWN MACRO TECH 3600 VZ 1 KLARK TEKNIK DN360 EQ DJ EQUIPMENT 2 PIONEER DJM600 MIXERS 2 PIONEER CDJ1000 MK2 CD PLAYERS 2 TECHNICS SL1200 MK2 TURNTABLES 1 AMERICAN DJ DCD- PRO 220 1 NUMARK DM1200 MIXER EXTRA/OTHER P.A. EQUPMENT 1 - EAW MX8001 PROCESSOR 1 JBL MPA600 AMP 2 - JBL MPA1100 AMPS 1 WHITE 4856 EQ 2 EAW Hi-Mid CABS 2 EAW SUB CABS 1 - MACKIE SRM 450 POWERED SPEAKER

PROJECTION & CAMERA EQUIPMENT Fillmore Video Inventory 1-9x12 drop down screen, front projection screen, controllable from booth, located down stage center, in front of the grand drape. Full Size Movie Screen- located just behind grand drape. Runs almost full width of the stage. Can be flown in and out from back stage. 46.5 ft wide x 24 high 1 - canon GL 2 Camera - signal is output through a mini to rca audio and rca video composite adapter. Has Tripod. Camera Control Cable- Located on the stage left wall. Approx. 100+ feet of cable. Edison power for sun gun light and line for clear com also ran with control cable. BNC Camera Signal Port- located in outer lobby behind bar. Sends camera signal to control booth. approx. 100 ft. cable. Also has edison power for sun gun light. 1 - Eiki LC-HDT 1000 Native aspect ratio of Seventeen by Nine Capable of other aspect ratios including 16x9, 16x10, and 4x3 Brightness of 10,000 lumens Distance to our 9x12 screen is 56 feet. Distance to our movie screen is 58 feet. lens used for movie screen is Eiki AH-32401 2.28"-2.99" Power Zoom Lens lens used for 9x12 screen is Eiki AH-22051 3.82"-5.16" Power Zoom Lens 1 - Sony px40 projector located balcony center with standard and long throw lensing, composite and computer inputs, approx. 3500 lumens 1 - data projector (brand?), approx 500 lumens, rca composite input. Only has standard lensing, no wide or long throw. 4 - Sony data projectors - approx. 1200 lumens RCA composite and VGA input. Only has standard lens, no wide or long throw. *Note*-long throw lens is required for anything being projected from the balcony to a screen anywhere near the stage. an edirol v-4 video mixer 4 inputs (rca), 2 outputs(rca), capable of mixing 2 channels of video with an assortment of wipes, dissolves, colors, and effects. a video routing system to allow additional ins and outs 2 DVD players 1 VHS player a DVJ x-1 to allow dj style scratching of audio and video from dvd's a T-view gold scan convertor vga input / s-video & rca output for resizing and adjusting computer images onto standard television and projection screens a Mac Powerbook which includes the following software: Imovie iphoto final cut express photoshop elements

Grid2 clip player/vj software controlled by mac powerbook motiondive VJ software controlled by mac powerbook and motiondive control console LCD screens - located throughout the venue at the bars and in main bathroom lobby for presentations, logos, live video, etc. Can be tied to the video running on the projection screen in the main room or can have other media than what is on the main screen. CONTROL BOOTH EQUIPMENT Dimensions-23ft wide x 11ft deep Located 60 from Stage Cable TV- Via Comcast connection 2 Sony 3/4 inch VCR s- for playback recording and editing Sony edit deck controller- controls 3/4 inch VCR s for insert and assemble editing Wave form monitor 2 color monitors- 7in b/w 4in source monitors- used for watching all VCR and DVD sources Small audio patch bay- 6 swappable in s and outs for VCR S and DVD players, 3 sources send to house sound board through DJ mixer DRESSING ROOMS There are 4 floors of dressing rooms located off stage right All rooms are lockable Only one stairway is available for access to the rooms. (All rooms are located upstairs) Each Dressing room has it s own personal bathroom There are (2) extra bathrooms in the stairwells leading up to the rooms Each dressing room has an access door for a wardrobe case. All wardrobe cases can be lifted by a chain motor to each level. Floor #1 16 x10 Tile Floor with shower, toilet and equipped with air conditioning & heat Floor #2 16 x10 Tile Floor with shower, toilet and equipped with air conditioning & heat Floor #3 16 x12 Carpeted Room with air conditioning & heat Bathroom is equipped with a sink and toilet (NO SHOWER) Vanity Mirror and Lights Floor #4 16 x12 Carpeted Room Bathroom is equipped with a sink and toilet (NO SHOWER) Vanity Mirror and Lights

DIRECTIONS Fillmore-Detroit I-75 from downriver: Take I-75 North, exit at Grand River and turn right at Woodward. I-75 Chrysler: Take I-75 South to Mack and turn right on Mack to Woodward and turn left. Theatre is on the right about 3/4 of a mile. I-94 from either direction: Get off at Woodward and take it south towards downtown. Theatre is on the right about 3 miles down. I-94 from the East: Take I-75 South to Mack and go right to Woodward. Turn left and it is on the right about 1 mile down. I-94 from the West: Take I-94 East to Lodge South to I-75 North and exit at Grand River and Turn right onto Woodward From I-96: Take I-96 towards Detroit and exit at I-94 East. Take it to Lodge South to I-75 North and exit at Grand River and turn right at Woodward.