Large Picture Archiving and Communication Systems of the World~Part 2

Similar documents
Initial Experience With Automatic Image Transmission to an Intensive Care Unit Using Picture Archiving and Communications System Technology

A Comparison of Case Retrieval Times: Film Versus Picture Archiving and Communications Systems

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline

Subsystem Throughputs of a Clinical Picture Archiving and Communications System. Albert W.K. Wong and H.K. Huang

An Economical, Personal Computer based Picture Archiving and Communication

Design and Implementation of a Digital Teleultrasound System for Real-Time Remote Diagnosis

Display Quality Assurance: Considerations When Establishing a Display QA Program. Mike Silosky, M.S. 8/3/2017

Nio. Industry-standard diagnostic display systems

DICOM. image protocol

Imaging systems and Telemedicine. Dr. Adrian Mondry

2018 Survey Summary for Storage in Professional Media and Entertainment

CAPTURE CAPTURE. VERSiON 1.2. Specialists in Medical. Digital Imaging Solutions

+ Human method is pattern recognition based upon multiple exposure to known samples.

Coronis 5MP Mammo. The standard of care for digital mammography

A Fiber-Optic Broadband CT/MR Video Communication System

Optimizing the Workflow of Radiologists

Is image manipulation necessary to interpret digital mammographic images efficiently?

DICOM Conformance Statement. CD-Medical Recorder for DCI systems CDM Release Document Number July 1998

Healthcare AYASE HEART HOSPITAL. Japan

The Diagnosis of Small Solitary Pulmonary Nodule:

Microbolometer based infrared cameras PYROVIEW with Fast Ethernet interface

Radiology Physics Lectures: Computers. Associate Professor, Radiology x d

Performance characteristics and quality assurance considerations for displays used in interventional radiology and cardiac catheterization facilities

Hospital Wide. Healthcare Display Solutions DICOM Displays, Large Screen Displays and Projectors

The Versatile and Powerful ACLxy. ACLxy

Open up to Extremity MRI

RSNA 2006 November 26 to December 1 Chicago. Guest author for ImPACT Dr. Koos Geleijns, Medical Physicist, Leiden University Medical Center.

DICOM Conformance Statement

Request for Proposals

Images and Formats. Dave Bancroft. Philips Broadcast Film Imaging

MULTI CHANNEL VOICE LOGGER MODEL: DVR MK I

DICOM Conformance Statement. Inturis Cardio View Station R 1.1. Document Number October 1999

Spatio-temporal inaccuracies of video-based ultrasound images of the tongue

From Autonomous Subsystems to Integrated System

How to Manage Video Frame- Processing Time Deviations in ASIC and SOC Video Processors

Coronis. A new generation of premium diagnostic display systems

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

Real-time QC in HCHP seismic acquisition Ning Hongxiao, Wei Guowei and Wang Qiucheng, BGP, CNPC

SECONDARY STORAGE DEVICES: MAGNETIC TAPES AND CD-ROM

Sample Analysis Design. Element2 - Basic Software Concepts (cont d)

CARESTREAM DIRECTVIEW Elite CR System

CARESTREAM DIRECTVIEW Elite CR System

Network Infrastructure for the Television beyond 2000

LINEAR DIGITAL RECORDER WITH 100 MBYTE/SEC HIPPI INTERFACE

What to consider when choosing a mammography display

Measuring Variability for Skewed Distributions

Pattern Smoothing for Compressed Video Transmission

S M A R T U LT R A S O U N D

Guidelines for Assuring Softcopy Image Quality

Nio. Industry-standard diagnostic display systems

Mammo Tomosynthesis 5MP

Clarity and confidence. Raising the bar in diagnostic imaging with Barco radiology and mammography displays

Module 8 VIDEO CODING STANDARDS. Version 2 ECE IIT, Kharagpur

Tuesday, Dec 3rd 10:15 to 11:00 IHE Classroom at InfoRAD at RSNA 2002.

VERINT EDGEVR 200 INTELLIGENT DIGITAL VIDEO RECORDER (Rev A)

Multimedia Systems and Hitachi Initiatives

NEMA XR 25 COMPUTED TOMOGRAPHY DOSE CHECK

DICOM medical image watermarking of ECG signals using EZW algorithm. A. Kannammal* and S. Subha Rani

World First Slim Cassette Type Digital Mammo. Upgrade Solution

Magnetic resonance imaging phase encoding:

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

True comfort and flexibility with the power of 3T.

Video Industry Making Significant Progress on Path to 4K/UHD

ROTARY HEAD RECORDERS IN TELEMETRY SYSTEMS

Fast Orbit Feedback at the SLS. Outline

Digital Television Fundamentals

Breast Imaging Essentials

Challenges in Social Health Insurance Schemes in Developing Countries

X-Ray Machines, CT Scanners, MRIs: The Pivotal Role of the GE Research and Development Center

The Century Archive Project CAP

How to Manage Color in Telemedicine

A Goal Based Cost-Benefit Analysis for Film Versus Filmless Radiology Departments

Signal Ingest in Uncompromising Linear Video Archiving: Pitfalls, Loopholes and Solutions.

Motion Video Compression

Instructions to Authors

A Terabyte Linear Tape Recorder

Understanding Compression Technologies for HD and Megapixel Surveillance

Intuitive Workflow by Barco. Designed for the way you work, naturally.

Content storage architectures

A variable bandwidth broadcasting protocol for video-on-demand

It s all about you. Mobile C-arm systems BV Endura

Lesson 7: Measuring Variability for Skewed Distributions (Interquartile Range)

Aerial Cable Installation Best Practices

HSR-1 Digital Surveillance Recorder Preliminary

CS311: Data Communication. Transmission of Digital Signal - I

Bioengineering 508: Physical Aspects of Medical Imaging Nature of Medical Imaging. Nature of Medical Imaging

Vascular. Development of Trinias FPD-Equipped Angiography System. 1. Introduction. MEDICAL NOW No.73 (2013.2) Yoshiaki Miura

Video-on-Demand. Nick Caggiano Walter Phillips

MULTI CHANNEL VOICE LOGGER MODEL PCVL - 4/8/10/16/32/64. ORIGINAL EQUIPMENT MANUFACTURER OF VOICE LOGGING SYSTEMS Radio and CTI Expert Organisation

Walter Graphtek's PL-EEG

THE INTERNATIONAL REMOTE MONITORING PROJECT RESULTS OF THE SWEDISH NUCLEAR POWER FACILITY FIELD TRIAL

VNS 104 MULTI STREAM DECODING SOFTWARE FOR VN MATRIX 225 OR VN-MATRIX 200 SERIES AV STREAMING

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

UCR 2008, Change 3, Section 5.3.7, Video Distribution System Requirements

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba

HELICAL SCAN TECHNOLOGY: ADVANCEMENT BY DESIGN

Communicating And Expanding Visual Culture From Analog To Digital

Universal Voice Logger

Lesson 7: Measuring Variability for Skewed Distributions (Interquartile Range)

Transcription:

Large Picture Archiving and Communication Systems of the World~Part 2 Roger A. Bauman, Guenther Gell, and Samuel J. Dwyer III A survey of 8Z institutions worldwide was done in 1995 to identify large picture archiving and communication systems (PACS) in clinical operation. A continuing strong trend toward the creation and operation of large PACS was identified, In the 15 months since the first such survey the number of clinical large PACS went from 13 to 23, almost a doubling in that short interval. New systems were added in Asia, Europe, and North America. A strong move to primary interpretation from soft copy was identified, and filmless radiology has become a reality. Workstations for interpretation reside mainly within radiology, but one-third of reporting PACS have more than 20 workstations outside of radiology. Fiber distributed data interface networks were the most numerous, but a variety of networks was reported to be in use. Replies on various display times showed surprisingly good, albeit diverse, speeds. The planned archive length of many systems was 60 months, with usually more than 1 year of data on-line. The main large archive and off-line storage media for these systems were optical disks and magneto-optical disks. Compression was not used before interpretation in most cases, but many systems used 2,5:1 compression for on-line, interpreted cases and 10:1 compression for Ionger-term archiving. A move to digital imaging and communication in medÿ cine interface usage was identified. Copyright 9 1996 by W.B. Saunders Company KEY WORDS: computers, radiology, picture archiving and communication systems (PACS), survey. p ART I of this two part series ~ reported the major findings of the 1995 worldwide survey of 82 institutions done to identify large-scale picture archiving and communication systems (PACS). The number of clinical large PACS went from 13 to 23 in a 15-month period. 2 This second report from the same survey describes various technical features reported by the 61 institutions who responded to the survey. Some 23 institutions have large PACS by the survey criteria: daily clinical operation, three or more modalities on the PACS, terminals inside Frorn Massachusetts General Hospital, Harvarcl Medical School, Boston, MA; Institute for Medical Informatics, University of Graz, Graz, Austria; and the Department of Radiology, University of Virginia, Charlottesville, VA. Address reprint requests to Roger A. Bauman, MD, 34 Everett Ave, Winchester, MA 01890. Copyright 9 1996 by HdB. Saunders Company 0897/1889/96/0904-000353. 00/0 and outside of radiology, anda minimum of 20,000 examinations handled on the PACS annually. MATERIALS AND METHODS A two-page survey form was sent by facsÿ or mail to 82 institutions thought to have large PACS as of February 1, 1995. Survey questions covered a wide range of topics, as detailed in Part 1 of the report. 1 Responses on several technical matters are reported here for the first time. Institutional Bed Size RESULTS Table 1 shows the reported institutional bed sizes. Workstation Distribution Table 2 shows the range and average number of workstations reported inside of and outside of Radiology. Network Information The question about the network protocoi was interpreted differently by some respondents. Responses included Transmission Control Protocol/Internet Protocol (TCP/IP), fiber distributed data interface (FDDI), PACS-net, and asynchronous transfer mode (ATM). TCP/IP seems to be the predominant protocol. The responses to the question about network speed were 15 with 100 Mbits/sec (usually FDDI), 2 with 10 Mbits/sec Ethernet, 1 with 80 Mbits/sec Token Ring, 1 with 155 Mbits/sec ATM, and 4 without information. Display Times Image transmission times from a request at a workstation until the image is displayed on it were subdivided into (1) frame buffer memory to display, (2) local workstation disk to display, and (3) remote disk storage to display. Within each of these categories the time to retrieve and display a 1,000 x 1,000 matrix x 8 bit image, a 1,000 x 1,000 matrix x 12-bit image anda 2,000 x 2,000 matrix x 12-bit image was 172 JournalofDigitallmaging, Vol 9, No 4 (November), 1996: pp 172-177

LARGE PACS OF THE WORLD--PART 2 173 Table 1. No, of Beds at Large PACS Institutions Facilities No. of Beds Asia Osaka University Hospital 1,116 Toshiba Hospital 310 Samsung Medical Center 650 Hokkaido University Hospital 875 Europe University Hospital of Geneva 1,600 University Hospital Graz 2,470 Viborg County Hospital 400 Conquest Hospital 400 Free University of Brussels, PRIMIS 700 Danube Hospital, SMZ0 850 North America Baltimore VA Medical Center 280 Wright Patterson AFB Meclical Center 301 The Credit Valley Hospital 360 Brooke Army Medical Center 450 University of Florida 570 Madigan Army Medical Center 600 UCLA Health Sciences Center 600 University of Virginia 620 Brigharn & Women's Hospital 702 Hospital of the University of Pennsylvania 772 University of Pittsburgh 800 Houston VA Medical Center Hospital 850 University of California San Francisco 925 Abbreviations: VA, Veterans Administration; UCLA, University of California at Los An9eles; PRIMIS, Pluridisciplinary for Research in Diagnostic Imaging Systerns; SMZ0, Social medizinisches Zentrum Ost; AFB, Air Force Base. asked. Because there were almost no differences in the 8- and 12-bit transfer times for the 1,000-class matrix images, they are shown together in Table 3. Archive and Disk Capacity Optical disks (ODs) in 15 installations and magneto-optical disks (MODs) in 5 installations are used as off-line storage media. The reported storage capacity of an OD varied between 0.6 and 10 Gbytes per disk with 10 different values given. The same is true with MODs, which range between 0.5 and 10 Gbyte/disk. OD jukeboxes have a capacity of between 76 and Table 2. Number of Workstations Reported In Radiology Range Outside of Radiology Range From To Mean From To Mean Interpetation 0 16 6 0 30 3 Review 0 12 3 0 93 16 Combined 3 17 9 -- -- -- 2,400 Gbytes with an average of 786 Gbytes (6 of the 15 installations with OD jukeboxes have 1,000 or more Gbytes). In addition, four MOD jukeboxes with capacities of 20, 40, 60, and 1,000 Gbytes and two helical scan jukeboxes with 50 and 100 Gbytes are in use. Concerning magnetic disk storage, there are several larger ones with 35, 40, 70, and 200 Gbytes; the rest are between 1 and 18 Gbytes (with an average of 8.4 Gbytes). Another question asked for the size of the magnetic disk storage on diagnostic workstations. The responses fall into three groups: 80 to 160 Mbytes (5 installations), 1,000 Mbytes (6 installations) and 2,000 to 6,000 Mbytes (10 instal]ations). Disk space on review stations is more limited: 4 instailations with 80 Mbytes, 6 with 200 to 700 Mbytes, 7 with 1,000 to 2,000 Mbytes and 1 with diskless review stations. Data Compression The responses on the compression ratios employed before interpretation are shown in Table 4 for on-line and for long-term archiving. Interfaces to Image Acquisition Devices The data reported for DICOM and other digital interfaces is shown in Table 5. The reporting of analog interfaces was incomplete but included digital fluoroscopy, nuclear medicine, and ultrasound interfaces. Reporting of devices without interfaces is definitely incomplete, so it is not possible to give the distribution of all interfaced and noninterfaced devices. Images per Study The answers to this question are summarized in Table 6. They refer not only to large PACS, but to all 37 responding PACS installations. Three other modalities were also reported to be interfaced with a PACS: digital cardiology with 250 images per examination, mammography with 6 images per examination (analog interface to PACS) anda cineradiography system with a digital interface and an average of 200 seconds per patient. Institutional Bed Size DISCUSSlON The number of beds of the hospitals with large PACS varies between 280 and 2,500 with

E 174 BAUMAN, GELL, AND DWYER Table 3. Reported Display Times (sec) 1,000 x 1,000 Matrix Display 2,000 x 2,000 Matrix Display Range Adjusted Range Adjusted To Display From N From To Mean Mean From To Mean Mean Frame buffer 14 0.5 5 WS disk 14 0.1 10 Remote disk Group 1 6 2.8 5 Group 2 14 20-100 6,000 1.5 3.2 m 1.1 0.1 11 2.2 1.23 -- 1 10 4 -- -- 2.8 25 -- -- ah average of 760. It is interesting to note the geographical distribution. In Europe the average is 1,075, in Asia 840 and in the United States 540. The mix of in-patient bed types included is not known, as no breakdown on chronic, acute, or other bed types was asked. Workstation Distribution About one-third of the hospitals have more than 20 workstations for review outside of Radiology. This supports an important trend that is strongly linked to economic savings by PACS--namely, that departments outside of Radiology need ready access to images and reports on electronic displays ir faster communication and filmless operation are to be realized. For both the interpretation and the review types of workstations outside of Radiology the distribution among the hospitals is skewed. Concerning workstations for interpretation 14 of the 23 large PACS have norte at all outside of radiology, and only two hospitals (one in Japan, one in the United States with 16 and 30, respectively) account for 70% of the total. With the trend toward primary interpretation from the PACS display (22 institutions) it is of high interest to know how many studies of the various types can be interpreted per workstation. Unfortunately, the data available provides no clear pattern to help with that question. Only three of the institutions reported 100% soft Table 4. Data Compression Ratios Compression Before Other Long-Term Ratio Interpretation On-Line Use Archive None (1:1) 12 8 6 2:1 6 6 -- 2.1-2.7:1 -- 2 8 3:1 1 3 5:1 -- -- 1 8:1 -- 1 -- 10:1 1 1 7 copy primary interpretation (with the exception of mammography). Of interest is that there is one large PACS that does no interpretation at all from soft copy. Network Information The sustained mean transfer rate under fullload question returned diverse results. The two Ethernets reported a mean transfer rate of 6 Mbits/sec; the 80 Mbits/sec Token Ring, a mean rate of 50 Mbits/sec; and the 155 Mbits/ sec ATM, a mean rate of 1.5 Mbytes/sec (ca. 12 Mbits/sec). For FDDI (100 Mbits/sec) the reported mean transfer rates varied widely; 3 between 10 and 12.5 Mbits/sec, one with 33 Mbits/sec, 1 with 82 Mbits/sec and 1 with 100 Mbits/sec sustained mean rate were reported. (The latter value is probably the theoretical rather than an actual rate.) Incidentally, three institutions using the same commercial system answering this question reported different sustained mean rates, possibly an inadvertent error in measurement or reporting. The answers to the network questions show a limitation of technical surveys. To get a high response rate, the questionnaire can be neither too detailed nor too technical. Conversely this can result in ambiguities that make data interpretation difficult if not impossible. In addition, Table 5. Digital Interfaces Modafity DICOM Interface Other Digital Interface CR 5 49 CT 25 26 DA -- 19 DF -- 15 MR 24 16 NM 3 30 U S 17 30 Abbreviations: CR, computed radiology; DA, digital angiogra- phy; DF, digital fluorography; MR, magnetic resonance; NM, nuclear medicine; US, ultrasound.

LARGE PACS OF THE WORLD--PART 2 175 Table 6. Images per Study No. of R~n9e Ran9e Modalities Respondents from 10 Average Median Remarks CR 23 CT 24 DA 16 DF 11 MR 20 NM 14 US 21 1 15 2.73 2 Two outlies with 6 and 15, leaving them out (range: 1-32; average: 20) 4 t 20 41 36.1 Taking only farge PACS, the upper bound would be 60, average 33. There is one installation with only 4 images per CT. Without them, the Iower bound would be 22. Nineteen installations within 22 and 40 5 120 30.4 20 Fourteen installations between 10 and 60 (average: 25.8) 10 60 19.5 14 One outlier with 60 (without it, range: 10-25; average: 15.4) 9 600 104,2 77.5 Omit two outliers on the Iow end (9 and 12) and one at the upper end (600) (range: 35-120; average: 86.1) 2 20 82 7.5 No outliers; relatively homogeneous distribution 4 40 189 16.5 No outliers Abbreviations: CR, computed radialogy; CT, cennputed tomography; OA, digital angiography; DF, digital fluorography; MR, magnetic resonance; NM, nuclear medicine; US, uitrasound. as PACS have moved from research and development projects to commerciai products, end users have become less interested in technical details. At the time of the survey, FDD1 was the leading network hardware and protocol supported by the main vendors (probably mostly as a backbone in connection with Ethernet and TCP/IP). The reported mean transfer rates w[th full load are so diverse that evidently the definitions or interpretations of measuring methods were not comparable. Display Times For the times from frame buffer memory to display the three highest values reported may be due to an error as they have longer or equal display times than for local workstation disk to display. If these three values ate omitted, the adjusted mean is 1.1 seconds for the display of a 1,000 x 1,000 image. The average for 2,000 x 2,000 images is 2.2 seconds (or 1.23 seconds if the upper outliers are omitted for the same reason). Most of the display times from the frame buffer are between 1 and 2 seconds; sufficient for most purposes except for smooth scrolling. A few installations (6 out of 23) claim display times between 0.1 and 0.5 seconds. AII the systems with 100% primary interpretation from workstations have short frame buffer to display times (between 0.1 to 1 second). Surprisingly, the differences between the display time from the frame buffer and from the local disk are relatively small. (It mÿ also be that times below 1 second are difficult to measure, and that the 1 second display time frequently given is a rough guess.) Nine installations reported display times of more than 2 seconds for 1,000 x 1,000 images from local disk. To allow for smooth reporting, this would require prefetching mechanisms from disk to the frame buffer for examinations with multiple slices. The delay from remote disk storage (archive) to display is for the most part too long for direct requests from the workstation by a radiologist except for examinations with only a few images. Especially in the case of jukeboxes the image transport to the workstation must be organized as a background prefetch process. The transfer times from remote disk storage to display fall into two groups as shown in Table 3. The first group probably uses remote magnetic disk, and the second one probably uses jukeboxes with optical or MOD disks. The single report of a time of 6,000 seconds might inciude fetching of off-l~ne disks. Archive and Disk Capacity ODs and, to a lesser extent, MODs are presently the standard devices for long-term archiving with jukeboxes in the Tbyte range for these operational systems. The many different capacities for disks suggest a weak point; the technology is reliable but not yet stable. Enhanced recording densities and formats entering the market may mean that the disks of the image archives might need to be recopied, because the drives to read them will disappear even ir the medium itself remains unchanged and readable. The problem also arises if one

176 BAUMAN, GELL, AND DWYER I 1988 1989 1990 1991 1992 1993 1994 1995 / Fig 1, For each year, the number of the 23 large PACS that first began clinical operation of at least three modalities is shown., The 1995 data ate from January only. switches to the newer storage technologies that are available. For diagnostic workstations, 1 Gbyte seems to be the minimum, going up to 6 Gbyte. The few installations in the 80 to 160 Mbyte range seem partly to work in an almost diskless manner in which images are transferred directly from remote storage to the random access memory. Present Maximum Archive Length and Planned Archive Length There were 26 responses to the months of on-line image archiving and 10 responses to the number of months for off-line archiving questions for individual modalities. The on-line archiving ranged from 1 to 40 months (average of 16 months). The off-line archiving ranged from none to 84 months imaging (average of 26.3 months). It is clear that the sites reporting have an average time of on-line archiving that is longer than 1 year, whereas the off-line archive average length is more than 2 years. The response to the question regarding total months of on-line and off-line image archiving planned is most interesting. A total of 18 responses reported on-line archiving with a range of 12 to 240 months (average: 51.2 months). Many sites selected 60 months. Interestingly, no one commented on their planned off-line storage. One might speculate that the reporting sites have not considered the problem of offshelf archiving for longer-term storage. Data Compression Data compression methods fall into the following two classes: lossless (also known as reversible compression, noiseless coding, redundancy reduction) and lossey (also known as irreversible, fidelity-reducing coding and entropy reduction). Image lossless coding compression ratios range up to about 3:1. The ratios reported appear in Table 4. Note the one site reporting use of a 10:1 compression ratio (lossey) before interpretation, a practice of interest and perhaps concern. Also note that five reported sites were apparently using lossey compression for on-line applications. Many sites now operational use no compression (1:1) for not yet interpreted studies, 2.5:1 for on-line use (Joint Photographic Expert Group), and 10:1 for long-terrn archiving. Interfaces to Image Acquisition Devices The data reported for analog interfaces and for noninterfaced devices was not complete enough to be analyzed, but the most often reported analog interfaces were for digital ftuoroscopy, nuclear medicine, and ultrasound. The digital interfaces reported were a mixture of digital imaging and communication medicine (DICOM) and other types; they are shown in Table 5. Unfortunately, the lack of adequate data for those devices without digital interfaces prevents computation of the percentage of digital interfaces in use.

LARGE PACS OF THE WORLD--PART 2 177 The 23 Large operational PAC systems identified by this survey and their year of first clinical operation were reported in Part 1.1 The histogram in Fig 1 shows how many began operation in each year. Only 9 of the 23 began in 1994 or 1995. The older systems would acquire the newer DICOM interfaces mainly as they replace acquisition devices. The number of the DICOM interfaces identified in 1995 is definitely higher than the number of American College of Radiology/National Electrical Manu- facturers Association interfaces identified in 1993. The trend toward the use of DICOM is striking. REFERENCES 1. Bauman RA, Gell G, Dwyer IIl S J: Large picture archiving and communication systems of the world--part 1. J Digit Imaging 9(3):99-103, 1996 2. Bauman RA: Worldwide experience with large PACS systems, in Proceedings of the S/CAR94 computer applications to assist radiology. Winston-Salem, NC, Symposia Foundation, Carlsbad, CA, 1994 Cost/Benefit Analysis of PACS: How Do Users Justify These Systems? BROADCAST TAPES AVAILABLE FROM SCAR On August 14, 1996, the Healthcare Informatics Telecom Network (HITN) broadcast as one in their series "Informatics: Washington Report" a program produced in collaboration with SCAR on Cost/Benefit Analysis of PACS. Participants were Michael Abiri, MD, Beth Israel Hospital, New York; Ethan Fener, Brigham and Women's Hospital, Boston; David Piraino, MD, Cleveland Clinic, Cleveland; Ken Spicer, MD, Medical University of South Carolina, Charleston; and Philip Drew, PhD, Concord Consulting Group, Concord, MA. Tapes of this program ate available from SCAR for $49.00 plus $5.00, shipping and handling. To order tapes, please contact the SCAR office, 1891 Preston White Drive, Reston, VA 22091; tel: 703-716-7548; fax: 703-648-9176.