HIRE AND TECHNICAL INFORMATION

Similar documents
Technical Specification for the Alley Theatre, Strabane

DEREHAM MEMORIAL HALL

INFORMATION FOR VISITING COMPANIES

Technical Specification

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

New Theatre Royal Lincoln Technical Information

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Theatre Technical Specifications

Theatre Technical Specification

2017 TECHNICAL SPECIFICATIONS

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

MAIN THEATRE TECHNICAL SPECIFICATION

Matt Dann Cultural Centre

TECHNICAL SPECIFICATIONS

Darlington Hippodrome Technical Specification

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

The Georgian Theatre Royal Technical Information For Visiting Companies

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

Technical Specification

CHELSEA THEATRE. Technical Specifications

The Lights Technical Guide June 2017

Lighthouse Theatre Technical Specification

Technical Specifications

Main House Technical Specification

Summary. Access and Parking

Main House Technical Specifications

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Dr JOHN GALLAGHER CONCERT CHAMBER

Cornerstone Technical Specifications 2018 / V1

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

The Haymarket Basingstoke Technical Specifications

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Technical Specifications Nov 2016

Technical Specification. Updated: April 2016

Technical Specification

Technical Pack. Attenborough Arts Centre

Pleasance London Main House Visiting Company Information Pack May 2017

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

Technical Specification Ardhowen Theatre

John Leslie Theatre. Technical Specifications. Updated July 2018

Latrobe Performing Arts Centre

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Stage. Get In & Parking

Technical Information

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Technical Manager Dave Nott Tel: * Mo: Deputy Technical Manager Anton Holmes Tel: *

Hirers Technical Information Pack

Shouson Theatre Venue Specifications (updated Jan 2017)

Technical Specifications Updated 01/10/2017. Stage

JERWOOD VANBRUGH THEATRE

TECHNICAL SPECIFICATION

ISLAND HALL TECHNICAL INFORMATION

Technical specifications Main theatre. Sound

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Technical Specification Ver 01/16

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

MAIN AUDITORIUM TECHNICAL INFORMATION

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

Monash University Academy of Performing Arts

Theatre Technical Specifications

THE STREET THEATRE. Technical Specifications

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

Monash Academy of Performing Arts

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Technical Specifications

Technical Specifications

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Technical Specification Pavilion Dance

Arlington Arts Tech Spec 2018

Where performance matters

Arcadia Performing Arts Center Technical Specifications and Information

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

Visy Theatre technical information and general specifications 2019

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

TECHNICAL SPECIFICATIONS

CENTRE FOR PERFORMING ARTS

UNIVERSITY CONCERT HALL. Technical Specification

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

RPAC REDLANDS PERFORMING ARTS CENTRE

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

Marjorie S. Deane Little Theater

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Hopgood Theatre NOARLUNGA CENTRE

Esso BHP Billiton Wellington Entertainment Centre

MAIN HOUSE TECHNICAL SPECIFICATION

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Specification

HIRERS INFORMATION PACK For further technical information or enquiries please contact:

Sandusky State Theatre Technical Specifications

Derby Theatre. Technical Information Main Stage. Derby Theatre. 15 Theatre Walk. St. Peters Quarter. Derby DE1 2NF.

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Technical Specification (Studio Theatre)

Contains directions and stock hire info.

MONASH University Academy of Performing Arts

Catford Broadway Theatre

Transcription:

HIRE AND TECHNICAL INFORMATION

2 Table of Contents Stage Information... 3 Accommodation... 4 Lighting Equipment... 5 Sound Equipment... 7 In-House Cloths... 8 Stage Plan... 9 Contact Information.. 10 Parking Information 10

3 Stage Information The theatre has a proscenium stage with slight rake, fly tower with 30 double purchase counter weight fly bars. The stage has permanent forestage extension with 4 winch bars above and separate house tab system. There is a safety curtain behind the proscenium arch. There is a scenery dock to the rear with roller shutters loading entrance stage left of the dock. There are wings to both sides of the stage which run from the dock to the forestage. There is an entrance between the dock and the rear centre of the stage. Stage Dimensions: Metric Imperial Stage Width (behind 10m 30 proscenium arch) Stage Width (forestage) 10.16m 33 4 Stage Depth (overall) 9m 29 7 Forestage Depth 3.8m 12 5 Proscenium Depth 1.85m 6 1 Proscenium Height 4.63m - 4.95m 15 2 16 2 Stage Height 1.17m 3 10 Dock Entrance Width 3.63m 11 11 Dock Entrance Height 2.41m 7 11 Wing Width (behind 1.54m 5 proscenium arch) Wing Height (behind 2.64m 8 7 proscenium arch) Wing Width (forestage) 2.59m 8 5 Dock Dimensions: Dock Width 4.97m 6.25m 16 3 20 5 Dock Length 10.4m 34 Dock Height 2.78m 3.33m 9 1 10 11 Roller Door Width 2.54m 8 4 Roller Door Height 3.10m 10 2 Fly Tower Details Grid Height 11m 36 30 x Double Purchase 10 Metres 30 Counter Weighted Maximum Weight Per Bar Maximum Weight Grid 250Kg 7050Kg

4 Accommodation The accommodation of the theatre comprises: Eight permanent dressing rooms all on the ground floor Green room on the ground floor that can be split in two to make another dressing room (8) Ladies and Gents toilets are on the 1st floor alongside stage Dressing room 1 and 2 are stage side. Dressing room 3 and 4 are to the rear of stage right. Dressing room 5, 6 & 7, Green Room are behind the dock. Dressing Room Dimensions: Room Length Width Estimated Occupancy Dressing 1 2.42m (7 11 ) 2.33m (7 7 ) 4-6 Dressing 2 2.42m (7 11 ) 2.33m (7 7 ) 4-6 Dressing 3 2.33m (7 7 ) 2.37m (7 9 ) 5-6 Dressing 4 4.06m (13 3 ) 2.47m (8 2 ) 10-12 Dressing 5 5.41m (17 9 ) 2.22m (7 3 ) 13 15 Dressing 6 4.03m (13 2 ) 2.75m (9 0 ) 10 12 Dressing 7 5.32m (17 5 ) 2.52m (8 3 ) 13-15 Dressing 8 * 7.72m (25 3 ) 3.73m (12 2 ) 25-28 Green Room 7.72m (25 3 ) 6.9m (22 7 ) All dressing rooms and green room have sound show relay and backstage call system. * Dressing Room 8 is a curtained off section of the Green Room.

5 Lighting Equipment Lighting desk: Dimmers: DMX Universes Lighting Bars Zero 88 Orb XF Strand Permus - 12 Circuits 2.5K (10 amps) per channel Booms Zero 88 Contour - 96 Circuits 2.5K (10 amps) per channel Overhead Stage Strand LD90 s - 72 Circuits FOH/Overhead 1: Generic Rig 2. In house intelligent equipment 3: Toured Equipment 1 x Balcony Bar 12 Channels 2 x FOH Drop Bars 6 Channels Each 2 x Advance Bars 12 Channels Each 2 x Advance Ladders 6 Channels Each 3 x Stage Bars 12 Channels Each 4 x Stage Drop Bars 3 Channels Each 2 x Stage Box (Back wall) 6 Channels Each 2 x FOH Roof Bays 10 Channels Each 2 x Stage Socapex 6 Channels Each Available Lanterns PROFILES ETC Source 4 19o 10 * 750w Permanently Rigged FOH ETC Source 4 Junior Zoom 5 * 650w Strand Patt 264/263/263A 2 * 1000w Strand Harmony 15o/28o ETC Source 4 zoom 15/30 1 * 1000w 9 * 750w Permanently Rigged FOH Pacific Profiles 8 * Permanently rigged on Balcony edge Strand SL 15/32 7 * Permanently rigged on FOH booms Strand SL 23/50 2 * Permanently rigged on FOH booms FRESNEL Strand Patt 223/743 25 * 1000w 215mm Strand Patt 243 8 * 2000w 300mm

6 BEAM LIGHTS Parcans P64 Long 43 * 1000w 250mm Parcans P64 Short Floor 10 * 1000w 250mm FLOOD UNITS Thomas 6 Unit 4 * 1000w SPECIALISED UV Canons Skytech Pin Spots Birdies Mirror Ball FOLLOW SPOTS Pani HMV1200 Robert Juliat Korrigan 2 * 400w 2 7 Permanently rigged FOH 2 * 1200w 2 * 1200w These are the Follow spots currently available to use Please note that there are only 2 follow spot positions DMX FIXTURES Moving Lights LED 6 * Martin Mac 500 (3x 23 degree, 3x 17 degree) 4 * Martin Mac 600 (2x 600, 2x 600NT) 10 * LEDJ Performer 18 RGBWA LED Pars (13amp) Atmospheric FX Le Maître MVS Haze Machine * 1 Fogtec VS-1500 Smoke machine * 1 Available Power 1 63a single ceeform Rated at 40 Amps located DSR wing. 2 63a three phase ceeform Rated at 63a located on dimmer floor SR Various 13 amp at stage level

7 Sound Equipment Sound Desk Output Control Amplification House Speakers fixed not moveable Soundcraft Vi1 32 inputs; 24 outputs at desk Soundcraft Compact Stage Box 32 inputs; 8 outputs;8 digital outputs 1 * NEXIA Controller 3 * WX3A System Controllers 5 * Crown K1 3 * Crown K2 6 * Martin Wavefront W2 (1 Left, 1 Right, 2 centre, 2 Under stage) 2 * Martin Wavefront WS2 (Left and Right) Foldback Speakers 2 * Warfdale 2 * HK Active DART (Wedges) 2 * DB Active Wedges Playback Options CD Player Windows PC running Tascam CD401 Multiplay (WAV file format only) Microphones and Miscellany Trantec S5.5 Radio 14 * Headset 3 * Handheld (note only 12 radio microphones can be used at once) Sure SM58 5 Sure SM57 Shure BG 4.1 Shure BG 3.1 PZM Crown PCC160 PZM Coherent Mic-200a AKG C451 Eb Drum Mic Set and clips Behringer ULTRA-DI DI100 DI Box 4 5 4 2 7 3 2 5 piece

8 Behringer ULTRA-G GI100 DI Box Artcessories Dual ZDirect DI Box Pulse DI Box Audibox AV DI Box 2 1 2 3 Music Store MIC 5 Boom Stand 7 Miscellaneous Communications Metro Audio cans system 2 circuits Ring A: Ring B: In-House Cloths and Masking Black Gauze Blue Velvet Tabs Black Velvet Tabs Pink Velvet Tabs Star Cloth Slash Curtain Sky Cloth White Cyc Cloth 2 sets of hard black masking (fixed position) 1 set of soft legs

9 Stage Plan

10 Contact Details If you have any questions about the venue and its technical facilities please don t hesitate to contact a member of the technical department and they will be happy to assist you. Dan Tilley Technical Manager Dan.tilley@albanytheatre.co.uk Adam Warren Technical Assistant (LX specialism) Adam.warren@albanytheatre.co.uk Lauren Coker Theatre Technician Lauren.coker@albanytheatre.co.uk Katherine Hodgson Technical Assistant (Sound specialism) Katherine.hodgson@albanytheatre.co.uk We will respond to any questions regarding the technical facilities about The Albany Theatre as soon as we can. For any other questions about The Albany Theatre please contact Rob Wimperis Operations Manager Rob.wimperis@albanytheatre.co.uk Ed Dyer Admin Coordinator Edward.dyer@albanytheatre.co.uk Parking Information Please be aware that there are restrictions when parking backstage at The Albany Theatre. You are only able to park lorries, trucks or vans at the rear of The Albany Theatre with a registered number plate. Please give your vehicle details to a member of the technical department at least a week prior to your arrival and we will register the vehicle for you. Cars can be unloaded at the dock of the theatre but then must be moved immediately to the multistory carpark next to the theatre. Under no circumstances can an unregistered vehicle be left at the rear of the theatre. The rear of the theatre is not owned by The Albany Theatre and any unregistered vehicle is liable to a fine. The Albany Theatre and its staff may not be held responsible for any fine enquired.