SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA

Similar documents
SIWAREX. FTA Getting Started. Info Status

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

16-BIT LOAD CELL/DUAL STATUS INPUT

SIMATIC. ET 200S distributed I/O IM151-1 BASIC interface module (6ES7151-1CA00-0AB0) Preface. Properties 1. Parameters 2. Error and system messages 3

4X70 PROFINET SYSTEM

2070 PROFINET MODULE

Transmitter Interface Program

MAXIMUM PRODUCTIVITY DUE TO SHORTEST CONVERSION TIMES

Meteor Product Catalogue

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A)

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

TABLE OF CONTENTS. Instructions:

GWL/ Power Group Technology Solutions Stay Powered for the Future

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

MICROMASTER Encoder Module

Model KT 53 Cooling incubators with thermoelectric cooling

Siemens Industry Online Support

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

MaxView Cinema Kit Quick Install Guide

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

SIMATIC. ET 200S distributed I/O 2AO U HS analog electronic module (6ES7135-4FB52-0AB0) Preface. Properties 1. Parameters 2.

3 Cleaning. 4 Technical data

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

4X50 ETHERNET SYSTEM

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Quick-Start for READ30

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

USB Smart Power Sensor

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

4x50 User s guide Modbus TCP

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

DVB-T Bursted Noise Signal Generation

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

PicoScope 2000 Series PC Oscilloscopes

DMP 331i / DMP 333i LMP 331 i

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

Solution Selection Guide

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

Modbus for SKF IMx and Analyst

Low-cost labelling system

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Operating instructions Electronic preset counter Type series 717

COLORSCAN. Technical and economical proposal for. DECOSYSTEM / OFF.A419.Rev00 1 of 8. DECOSYSTEM /OFF A419/09 Rev November 2009

Instruction manual Alfa Laval PROFINET weighing module

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Extra long-range RFID (proximity) card reader

User Manual. for. Panel mounted instrument

Engineered to meet your needs T he oldest name in stud welding,

Standard RS232 RS ma

ADS Basic Automation solutions for the lighting industry

American National Standard for Lamp Ballasts High Frequency Fluorescent Lamp Ballasts

VBOX3i Dual Antenna. Measures Slip and Pitch/Roll (RLVB3iSL) Features

TELEDYNE HASTINGS INSTRUMENTS

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

DIGISPOT II. User Manual LOGGER. Software

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

2x50 ETHERNET MODULE

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Model KT 115 Cooling incubators with thermoelectric cooling

Capacitance Level Measurement Electronic insert FEC 12

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

Netzer AqBiSS Electric Encoders

medlab One Channel ECG OEM Module EG 01000

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

READ THIS FIRST. Morphologi G3. Quick Start Guide. MAN0412 Issue1.1

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Noise Detector ND-1 Operating Manual

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model KT 170 Cooling incubators with thermoelectric cooling

DANGER WARNING CAUTION

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

32 Channel CPCI Board User Manual

DCF Module FAZ 3000 DCF

QUAD THERMOCOUPLE INPUT

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

EEG A1452 SCTE-104 Inserter Frame Card

R&S ZVA110 Vector Network Analyzer Specifications

User Manual POE. Twisted Pair POE Extender

SCALE & WEIGHT DISPLAYS

Product Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads

Coherence Measurement between two Signals regarding Timing, Phase and Gain Application Note

Digital Input Modules for Compact FieldPoint

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Lab Determining the Screen Resolution of a Computer

Transcription:

SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA Quick Guide For modules with order number 7MH4900-2AA01 Contents 1 2 3 4 5 6 Hardware-Requirements.. Connections... Start SIWATOOL FTA........ Resolution.... Filter. Calibration...... 3 5 6 8 8 10 Siemens AG 1

Introduction SIWAREX FTA is a calibratable and versatile weighing electronics for SIMATIC S7, C7 and PCS7. It can be used for automatic and non-automatic weighing, e.g. for the production of mixtures, filling, loading, monitoring and bagging. Purpose of this document for functional safety This programming manual contains all information that you will require to commission and use the device. It is aimed at persons who install the device mechanically, connect it electrically, parameterize and commission it, as well as at service and maintenance engineers. Notes on warranty The contents of this programming manual shall not become part of or modify any prior or existing agreement, commitment or legal relationship. All obligations on the part of Siemens AG are contained in the respective sales contract, which also contains the complete and solely applicable warranty conditions. Any statements on the device versions described in the programming manual do not create new warranties or modify the existing warranty. The content reflects the technical status at the time of printing. We reserve the right to make technical changes in the course of further development. Validation of this document This documentation is only valid in conjunction with the manual SIWAREX FTA. This manual is available on the Siemens homepage. http://support.automation.siemens.com/ww/view/en/17831309/133300 Siemens AG 2

1 Hardware Requirements Following hardware parts and software are requested to integrate a scale in SIMATIC. 24V Power supply, S7-300 CPU or ET200M Station, memory card for CPU, SIWAREX FTA front connector for SIWAREX FTA, SIWATOOL FTA software, RS232 cable, computer with Windows XP or higher and a calibration weight bigger than 5% of the sum of the nominal value of all load cells. 24V PS S7-3xx PLC or ET 200M SIWAREX FTA 7MH4900-2AA01 SIWATOOL RS232 Cable 7MH4607-8CA Configuration Package for SIWAREX FTA 7MH4900-2AK01 Siemens AG 3

Adjustment weight > 5% of the sum of the nominal value of all load cells Scale The operating environment shown below includes the following: PS207 2A power supply, ET200M station or CPU3xx, SIWAREX FTA weighing module, MPI communication card, SIWATOOL cable SIWAREX FTA module Load Cell Cable Siemens AG 4

2 Connections 24V Power Supply RS232 Interface Connection terminal of the sensor Load Cell Connection: Termination Clamp Signal Remark 35 SEN+ Sensor Line + 36 SEN- Sensor Line - 37 SIG+ Measuring Line + 38 SIG- Measuring Line 39 EXC+ Load Cells Feeding Voltage + 40 EXC- Load Cells Feeding Voltage Siemens AG 5

3 Start SIWATOOL FTA On the SIWATOOL FTA interface select the interface COM1 used on your computer. Siemens AG 6

Click Online When the communication is established Online turns into grey. Siemens AG 7

4 Resolution of SIWAREX FTA The Siwarex FTA electronics converts the weight into a 24 bit value. The value is comprised between approx. 1.4 Mio... 15.4 Mio Digits. That internal digits value is taken for further calculations, e.g. gross weight. These numbers are then transmitted as real values to the SIMATIC PLC. 5 Type of Filters (Limit frequency: Low-pass filter (0.05 Hz ~ 20 Hz)) 3 types of filters are available to choose for suppressing interferences. If it is set to 5 Hz, the scale will respond quickly to the weight change; if it is set to 0.05 Hz, the scale will move slowly. % Digital low pass filter step response fg=2hz ms The average value filter is used to calm the weighing value compensating for random interferences. The weight is measured according to the average value of n weight values. If n = 10, 10 weight values will be used for calculating the average value. The earliest value is discarded every 10 milliseconds and the latest value will be added for the calculation. Enter filterdata s in DR3 Depth of average value filter e.g.=10 Siemens AG 8

6 Calibration Before calibrating, set the Service mode on (1). Only one click is required. Once the setting is successful this icon appears. Whether not, please click on Error type and follow the advice Click Adjustment parameter (DR3) Siemens AG 9

Enter the Adjustment weight (e.g. "150.0") and set the Characteristic value range. Set parameters Min/Max weight for weighing range 1 and the Resolution range 1 in register Calibration parameter 2. Siemens AG 10

"Resolution range 1": It is the minimum change of the displayed weight. The unit is the same as the Weight unit selected under the "Calibration parameter 3" tab (see below). Examples: "Resolution range 1" is set to 0.05 kg, so the minimum change is 0.05 kg. Siemens AG 11

Whether the"resolution range 1" is set to 1.0 kg the minimum change is 1 kg. Note: the resolution is related to the weight display and is independent from the weight precision. Set parameter Weight unit in register Calibration parameter 3 and then click Send. Siemens AG 12

Ensure the scale is empty (not loaded) and click Adjustment zero valid (3). Afterwards the displayed value is as follows: Load the scale with the calibration weight 1 (the display may show a different weight value) and then click Adjustment weight 1 valid (4). Siemens AG 13

The display shows the Adjustment weight 1. The adjustment is completed now. If the corresponding weight is now changed it will be according to the actual weight and exact accuracy will be achieved. Please set Service mode off (2) Finally you may save the calibration data s into a file. Receive all data from the SIWAREX FTA to the PC Siemens AG 14

During the transmission from the Siwarex FTA module to the PC the following message appears: Save as a Siwatool FTA File: Siemens AG 15

If you have any issues or suggestions regarding the related products or documents, please feel free to contact: Technical support for SIWAREX: Siemens AG Industry Automation (IA) Sensors and Communication Process Instrumentation D-76181 Karlsruhe Germany Tel: +49 721 595 2811 Fax: +49 721 595 2901 E-mail: siwarex.hotline.aud@siemens.com Website: www.semens.com/siwarex Copyright Statement All rights reserved by Siemens AG This document is subject to change without notice. Under no circumstances shall the content of this document be construed as an express or implied promise, guarantee (for any method, product or equipment) or implication by or from Siemens AG. Partial or full replication or translation of this document without written permission from Siemens AG is illegal. Siemens AG 16