SPECTRO Series SPECTRO-3-50-FCL. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 10)

Similar documents
SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

Transmitter optics with 9x white light LED (optics cover made of glass)

SPECTRO Series SPECTRO-3-5-DIF-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

Data Sheet SPECTRO-3-SLU-BA-ANA + SI-SLU-16. Receiver optics incl. 3-color filter detector (True Color), scratch-resistant optics cover made of glass

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

SPECTRO Series SPECTRO /0 -MSM-ANA-VIS. Design. SPECTRO-3 Series True Color Sensors. Accessories: (p. 8-9) Product name:

SPECTRO Series SPECTRO-1-50-DIL. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

SPECTRO Series SPECTRO-1-30-UV/UV. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

SPECTRO Series. SPECTRO-1-30-UV/VIS-9x1. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

SPECTRO Series SPECTRO-1-POF. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Accessories: (p ) Product name:

L-LAS Series L-LAS-LT-2500-XL. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-2500-XL

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

RLS Series RLS-GD-20/20. Design. RLS Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

L-LAS Series L-LAS-LT-130-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

R3-M-A1.1-(1.5) X (Receiver fiber optics incl. add-on aoptics KL-M18-A1.1 and blast-air top part ABL-M18-3)

Electrical connection

Electrical connection

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Electrical connection

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

LD OEM/LD PDS/LD PeCo

Linear encoders without bearings incremental System for linear motion feedback

Operating Instructions

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

V 180 Series Photoelectric Switches

Hour Meters / Timers, electronic

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

Absolute Encoders Multiturn

SPACESCAN SERIES SS 02

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

W100L: Laser Sensor in Mini- Format

Operating instructions Electronic preset counter Type series 717

Multifunction devices

Sensor technologies Proximity sensors Series ST4. Brochure

SU17 Series Fiber Optic Sensors

Displacement Measuring System for Cylinder Series OSP-P

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

HITACHI. Instruction Manual VL-21A

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Manual Software SI-LCC-Scope V2.0

Electrical connection

Electrical connection

part numbers 5 VDC ±5% 5 VDC ±5% 35 ma 30 ma RS 422 3,2 MHz < 4 VDC 160 khz RS 422

Photoelectrics Through-beam Type PA18C.T..., DC

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

WF next: Fork sensors for a wide range of applications

Time meter electronic

FLAT DISPLAY TECHNOLOGY

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

DSM Series Ultra Thin Surface Mount Single Digit 7-Segment LED Display

Progressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 )

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

DSM Series Ultra Thin Surface Mount Single Digit 7-Segment LED Display

Assembly. Front view. LEDs. Parametrization interface. Power Bus

SURFACE MOUNT LED LAMP FULL COLOR 1210

Technical data. General specifications. Indicators/operating means

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

ENC - LKE51 - L I B

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Product Information. EIB 700 Series External Interface Box

Electronic Pulse Counter Combination device

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

AMP DISPLAY INC. SPECIFICATIONS AMP DISPLAY INC 9856 SIXTH STREET RANCHO CUCAMONGA CA TEL: FAX:

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Light Curtain Type LA

Absolute encoders multiturn

SURFACE MOUNT LED LAMP STANDARD BRIGHT 1206 (Reverse Mount)

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Emergency lighting units EM powerled

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Material: Weight: IP Rating: Cable: Connector:

Transcription:

SPECTRO Series - Measuring range typ. 10 mm... 150 mm - Big dynamic range due to focused white-light operation - Up to 31 colors can be stored - RS232 interface (USB or Ethernet adapter is available) - 9x super-bright white-light LED, focused (AC-/DC-/PULSEoperation or OFF for luminous objects can be switched) - Color detection, contrast detection, and gray scale detection - Insensitive to outside light (in AC- or PULSE-operation) - Brightness correction can be activated (STAT/DYN) - Scan frequency max. 35 khz (in DC- or OFF-operation) - Switching frequency typ. 60 khz - Several TEACH functions (via PC, PLC, or push button) - Various evaluation algorithms can be activated - BEST HIT mode ( human color assessment ) - Switching state display by means of 5 yellow LEDs - Parameterizable via Windows software, scope function - Temperature compensated - Averaging can be activated (from 1 up to over 32000 values) - Color control of luminous objects (LEDs, halogen lamps, displays,...) - 3-color filter detector (true color detector: human color perception ) Aufbau Product name: -d5 (incl. Windows PC software SPECTRO3-Scope and SPECTRO3-COMFORT-Scope) Accessories: (p. 10) FL-34 (flange) WFL-34 (flange, angle type) d5 =By use of an aperture Ø 5 mm the detection range at the working distance of 50 mm will be reduced to typ. 6 mm Optics holding device (aluminum, anodized) Receiver optics with 3-color filter detector (True Color) transmitter optics with 9x white light LED (scratch-resistant optics cover made of glass) Sturdy aluminum housing, anodized in blue 4-pole fem. connector Binder Series 707 (RS232 interface) Connecting cable: cab-las4/pc or cab-4/usb or cab-4/eth TEACH button (external teaching via input IN0) 8-pole fem. connector Binder Series 712 (connection to PLC) Connecting cable: cab-las8/sps Mounting screws (M34) LED display: Switching state indication by means of 5 yellow LED (2015-12-17) / Page 1 of 11

Technische Technical Data Daten Model Voltage Current Max. supply consumption switching current -d5 +24VDC (± 10%), reverse polarity protected, overcurrent protected < 220 ma 100 ma, short circuit proof Switching state indication 5 yellow LED visualize the physical state of the outputs OUT0... OUT4 Input digital (1x) IN0 (Pin 3), digital (0V/+24V) or teach button at the housing O utputs digital (5x) OUT0... OUT4 (Pin 4... 8): digital (0V/+24V), npn-/pnp-able (bright-/dark-switching, can be switched) Interface RS232 Pulse Averaging lengthening Scan frequency Switching Transmitter frequency (light source) Transmitter control Measuring range AC operation (LED 0... 100 ms, adjustable via PC software max. 32768 values, adjustable via PC software LED operation, can be switched via PC software: AC operation: max. 20 khz (depends on parameterization) DC and OFF operation: max. 35 khz (depends on parameterization) PULSE operation: max. 5 khz (depends on parameterization) typ. 60 khz 9x super-bright white-light LED, focused can be switched via PC software: MODE-AC), DC operation (LED MODE-DC), OFF typ. 10 mm... 150 mm operation (LED MODE-OFF) Receiver 3-color filter detector (TRUE COLOR detector, human color perception ), color filter curves acc. to CIE 1931 Receiver gain setting Ambient light 8 steps (AMP1... AMP8), adjustable via PC software max. 5000 Lux Detection range (half intensity width) typ. 12 mm at a distance of 10... 60 mm typ. 15 mm at a distance of 80 mm typ. 19 mm at a distance of 100 mm typ. 23 mm at a distance of 120 mm typ. 27 mm at a distance of 140 mm typ. 6 mm at a distance of 10... 60 mm typ. 7,5 mm at a distance of 80 mm typ. 9,5 mm at a distance of 100 mm typ. 11,5 mm at a distance of 120 mm typ. 13,5 mm at a distance of 140 mm Reproducibility in the X, Y color range each 1 digit at 12-bit A/D conversion Temperature drift X,Y X/ T; Y/ T typ. 0,2 digits/ C (< 0,01% / C) Color difference Ε >= 0, 5 C olor space X Y INT sim (Lab) Color memory capacity Housing dimensions non-volatile EEPROM with parameter sets for max. 31 colors length approx. 130 mm x Ø 32 mm (threaded M34x1.5) or Ø 34 mm (optics holding device), without connectors H ousing material aluminum, anodized in blue (optics holding device: aluminum, anodized) E nclosure rating IP67 (optics), IP64 (electronics) Connecting cables to PLC: cab-las8/sps or cab-las8/sps-w to PC/RS232 interface: cab-las4/pc or cab-las4/pc-w to PC/USB interface: cab-4/usb or cab-4/usb-w to PC/Ethernet interface: cab-4/eth T ype of connector connection to PLC: 8-pole fem. connector (Binder 712), connection to PC: 4-pole fem. connector (Binder 707) Operating Storage temp. range temperature range -20 C... +55 C -20 C... +85 C EMC test acc. to DIN EN 60947-5-2 (2015-12-17) / Page 2 of 11

Dimensions All dimensions in mm (2015-12-17) / Page 3 of 11

Connector Assignment Connection to PLC: 8-pole fem. connector Binder Series 712 Pin: Color: Assignment: 1 white GND (0V) 2 brown +24VDC (±10%) 3 green IN0 4 yellow OUT0 (Digital 0: typ. 0 1V, Digital 1: typ. +Ub - 10%) 5 grey OUT1 (Digital 0: typ. 0 1V, Digital 1: typ. +Ub - 10%) 6 pink OUT2 (Digital 0: typ. 0 1V, Digital 1: typ. +Ub - 10%) 7 blue OUT3 (Digital 0: typ. 0 1V, Digital 1: typ. +Ub - 10%) 8 red OUT4 (Digital 0: typ. 0 1V, Digital 1: typ. +Ub - 10%) Connecting cable: cab-las8/sps-(length) cab-las8/sps-w-(length) (angle type, 90 ) (standard length 2m) Connection to PC: 4-pole fem. connector Binder Series 707 Pin: Assignment: 1 +24VDC (+Ub, OUT) 2 GND (0V) 3 RxD 4 TxD Connection via RS232 interface at the PC: Connecting cable: cab-las4/pc-(length) cab-las4/pc-w-(length) (angle type 90 ) (standard length 2m) cab-las8/sps-... (max. length 25m, outer jacket: PUR) cab-las8/sps-w-... (max. length 25m, outer jacket: PUR) alternative: Connection via USB interface at the PC: Connecting cable (incl. driver software): cab-4/usb-(length) cab-4/usb-w-(length) (angle type 90 ) (standard length 2m) alternative: Connection to local network via Ethernet bus: Adapter (incl. software SensorFinder ): cab-4/eth-500 (standard length 0.5m) cab-las4/pc-... (max. length 10m, outer jacket: PUR) or cab-las4/pc-w-... (no picture) (max. length 5m, outer jacket: PUR) Optional: External CAT5 cable, e.g. cab-eth/m12d-rj45-flx-(length) cab-4/eth-500 (length 0.5m, outer jacket: PUR) 4-pole M12 fem. conn. (D-coded) for connection of an external CAT5 cable, e.g. cab-eth/m12d-rj45-flx-(length) cab-4/usb-... or cab-4/usb-w-... (no picture) (each max. length 5m, outer jacket: PUR) (2015-12-17) / Page 4 of 11

Measuring Principle Measuring principle of the color sensors of SPECTRO-3 series: The SPECTRO-3 provides highly flexible signal acquisition. For example, the sensor can be operated in alternating-light mode (AC mode), which makes the sensor insensitive to extraneous light. It also can be set to constant-light mode (DC mode), which makes the sensor extremely fast and allows a scan-frequency of up to 35 khz. An OFF function turns off the integrated light source at the sensor and changes to DC operation. The sensor then can detect so-called self-luminous objects. In PULSE operation extremely dark surfaces can be reliably detected. With the stepless adjustment of the integrated light source as well as the selectable gain of the receiver signal and an INTEGRAL function the sensor can be set to almost any surface or any self-luminous object. When the integrated light source of the SPECTRO-3 color sensor is activated, the sensor detects the radiation that is diffusely reflected from the object. As a light source the SPECTRO-3 color sensor uses a white-light LED with adjustable transmitter power. An integrated 3-fold receiver for the red, green, and blue content of the light that is reflected from the object, or the light that is emitted by a self-luminous object, is used as a receiver. The SPECTRO-3 color sensor can be taught up to 31 colors. For each of these taught colors it is possible to set tolerances. In X Y INT - 2D or s i M - 2D mode these tolerances form a color cylinder in space. In X Y INT - 3D or s i M - 3D mode the tolerances form a color sphere in space. Color evaluation according to s i M - 2D is based on the lab calculation method. All modes can be used in combination with several operating modes such as FIRST HIT and BEST HIT. Raw data are represented with 12 bit resolution. As a special feature the sensor can be taught two completely independent parameter sets. Input IN0 can then be used to tell the sensor which parameter set it should work with. Color detection either operates continuously or is started through an external PLC trigger signal. The respective detected color either is provided as a binary code at the 5 digital outputs or can be sent directly to the outputs, if only up to 5 colors are to be detected. At the same time the detected color code is visualised by means of 5 LEDs at the housing of the SPECTRO-3. [Please note: Visualisation by means of LEDs not available with SPECTRO-3- -JR types.] With a TEACH button at the sensor housing the color sensor can be taught up to 31 colors. For this purpose the corresponding evaluation mode must be set with the software. The TEACH button is connected in parallel to the input IN0 (green wire at cable cab-las8/sps). [Please note: TEACH button not available with SPECTRO-3- -JR types.] Parameters and measurement values can be exchanged between a PC and the SPECTRO-3 color sensor through the serial RS232 interface. All the parameters for color detection also can be saved to the non-volatile EEPROM of the SPECTRO-3 color sensor through this serial RS232 interface. When parameterisation is finished, the color sensor continues to operate with the current parameters in STAND-ALONE mode without a PC. The sensors of the SPECTRO-3 series can be calibrated (white-light balancing). Balancing can be performed to any white surface. A ColorChecker TM table with 24 color fields is available as an alternative. White-light balancing or calibration can be performed to one of the white fields. Visualization Visualization of the color code: The color code is visualised by way of 5 yellow LEDs at the housing of the SPECTRO-3 color sensor. At the same time in the binary mode (OUT BINARY) the color code indicated on the LED display is output as 5-bit binary information at the digital outputs OUT0 to OUT4 of the 8-pin SPECTRO-3/PLC socket. The SPECTRO-3 color sensor is able to process a maximum of 31 colors (color code 0... 30) in accordance with the corresponding rows in the COLOR TEACH TABLE. An "error" respectively a "not detected color" is displayed by the lighting of all LED (OUT0... OUT4 digital outputs are set to HIGH-level). In the DIRECT mode (OUT DIRECT HI or OUT DIRECT LO) the maximum numbers of colors to be taught is 5 (color no. 0, 1, 2, 3, 4). If DIRECT HI is activated, the specially digital output is set to HI, while the other 4 are set to LO. If the current color does not correspond with any of the teach-in colors, all digital outputs are set to LOW (no LED is lighting). If DIRECT LO is activated, the specially digital output is set to LO, while the other 4 are set to HI. If the current color does not correspond with any of the teach-in colors, all digital outputs are set to HIGH (all LED are lighting). (2015-12-17) / Page 5 of 11

LED-Display LED display: The color code is visualized by means of 5 yellow LEDs at the housing of the color sensor. At the same time the color code indicated at the LED display is output as 5-bit binary information at the digital outputs OUT0... OUT4 of the 8-pole PLC connector. In the DIRECT mode the maximum number of color codes to be taught is 5. These 5 color codes can be directly output at the 5 digital outputs. The respective detected color code is displayed by means of the 5 yellow LEDs at the color sensor housing. 0 3 6 1 2 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 OUT0 OUT1 OUT2 OUT3 OUT4 24 25 26 1 2 4 8 16 27 28 29 30 Error or not detected (2015-12-17) / Page 6 of 11

Parameterization Windows user interface: The color sensor is parameterized under Windows with the SPECTRO3-Scope software. The Windows user interface facilitates the teach-in process at the color sensor and supports the operator in the task of adjustment and commissioning of the color sensor. Under Windows representation of the color value on a PC in numeric form and in a color chart, and representation of RGB values in a time chart. In addition the current RGB values are displayed as a bar chart. The RS232 interface (tab PARA1 or PARA2) is used for setting parameters such as: - POWER MODE: Light power of the LED - LED MODE: Triggering of the internal light source - GAIN: Used for setting the gain of the receiver - AVERAGE: Averaging over a maximum of 32768 values - INTEGRAL: This function field is used to set the number of scan values (measurement values) over which the raw signal measured at the receiver is summed up. This integral function allows the reliable detection even of extremely weak signals - MAXCOL-No.: Number of colors to be checked - OUTMODE: Triggering of the digital outputs - INTLIM: Minimum intensity required for color evaluation - EVALUATION MODE: Various evaluation modes to choose from (FIRST HIT, BEST HIT, MIN DIST, COL5, THD RGB) - CALCULATION MODE: There are 2 methods of teaching a color, which are selectable via CALCULATION MODE. The CALCULATION MODE X Y INT - 3D (or s i M - 3D ) uses a color sphere in space with radius TOL. Contrary to this, the CALCULATION MODE X Y INT - 2D (or s i M - 2D ) uses a color cylinder in space with radius CTO or sito and with height ITO or M. The teach process is the same for both methods. Color evaluation according to "s i M - 2D" uses the Lab calculation method - EXTEACH: In all the evaluation modes teaching of a color can be performed externally through IN0 or by means of the button at the sensor housing [Please note: TEACH button not available with SPECTRO-3- -JR types.] - TRIGGER: Continuous or external or self trigger (2015-12-17) / Page 7 of 11

Parametrization Windows user interface SPECTRO3-COMFORT-Scope as an alternative to SPECTRO3-Scope: Color sensors of the following types can be quickly parameterised with the SPECTRO3-COMFORT-SCOPE software: SPECTRO-3 (im M34 housing) SPECTRO-3-CL SPECTRO-3-JR SPECTRO-3-SL SPECTRO-3-SLE The software features menu guidance that prompts the user to enter all the relevant parameters. Firmware Update Firmware update by means of software ProgramLoader or FirmwareLoader : The software ProgramLoader or FirmwareLoader allows the user to perform an automatic firmware update. The update will be carried out through the RS232 interface. An initialisation file (xxx.ini) and a firmware file (xxx.elf.s) are required for performing a firmware update. These files can be obtained from your supplier. In some cases an additional firmware file for the program memory (xxx.elf.p.s) is also needed, and this file will be automatically provided together with the other two files. (2015-12-17) / Page 8 of 11

Diagrams Diagrams: DETECTION RANGE (HALF INTENSITY WIDTH) and RELATIVE INTENSITY Detection range (half intensity width d) : 12 mm (typ.) at a working distance of 50 mm 30 Detection range [mm] Detection range [mm] Half intensity width 25 20 15 10 5 0 10 30 50 70 90 110 130 150 Working distance x [mm] Relative intensity : 100% at a working distance of 20 mm (INTENSITY 3814) Relative intensity [white] INT [relative] 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 10 30 50 70 90 110 130 150 Working distance x [mm] INT (Intensität, empfängerseitig) (intensity, receiver-side) 100 % d Halbwertsbreite d Half intensity width d 50 % y x - y +y (2015-12-17) / Page 9 of 11

Mounting Accessories FL-34 (flange) Example: FL-34 with SPECTRO-3-30-DIL mounted WFL-34 (flange, angle type 90 ) Example: WFL-34 with SPECTRO-3-30-DIL mounted (All dimensions in mm) (2015-12-17) / Page 10 of 11

Application Example Measurement of colored foils in the gray/beige range Color inspection of colored foils in the gray/beige range. The test was performed with a color sensor at a distance of approx. 50 mm from the object. (2015-12-17) / Page 11 of 11