Agilent X-Series SA portfolio Oct 09 mmw EXA 10 Hz to 32/44GHz May 12 Sep 06 PXA X-Series High-performance 3 Hz to 26.5 GHz 3 Hz to 43/44/50 GHz Apr 11 Oct 09 EXA X-Series General-purpose 10 Hz to 26.5 GHz Sep 07 MXA X-Series Wireless accelerator 10 Hz to 26.5 GHz 8560EC Mid- performance PSA Market leading performance 3 Hz to 50 GHz CXA Low-cost 9 khz to 7.5 GHz ESA World s most popular 100 Hz to 26.5 GHz 30 Hz to 2.9/6.4/13.2/26.5 GHz 40/50 GHz X-Series Code Compatibility CSA Low cost portable 100 Hz to 7 GHz Backward CC with legacy Inherent X-Series CC
Product Briefing for 856x Series Best in Class Phase Noise Performance Product Max Frequency Ref. Pricing USD ($) 8560EC 2.9 GHz Not applicable Disco was 9/1/09 8561EC 6.7 GHz Not applicable Disco was 5/1/04 Headlines: +/-1.0 db absolute amplitude accuracy -149 dbm/hz DANL <-113 dbc/hz phase noise at 10 khz offset Portable, MIL-PRF-28800, Class 3 rugged 8562EC 13.6 GHz Not applicable Disco was 9/1/09 8563EC 26.5 GHz Not applicable Disco was 9/1/09 8564EC* 40 GHz $99,687 To be disco ed 06/01/12 8565EC* 50 GHz $119,221 To be disco ed 06/01/12 *: Disco announced June 1, 2011; Actual disco date: June 1, 2012
Product Discontinuance Update Discontinued (RF/microwave models): Products: 8560EC / 8562EC / 8563EC End of support life Aug 31, 2014 Product alternatives MXA, EXA, PXA depending on options required Migration support N9061A 856x to MXA or EXA code support Upcoming discontinuance (millimeter wave models): Products affected: 8564EC / 8565EC Broad announcement June 1, 2011 Last order date May 31, 2012 End of support life May 31, 2017 Product alternatives EXA (mmw), PXA depending on options required Migration support N9061A 856x to PXA or EXA code support
Product Life Cycle of 8560 Series Product Frequency Introduction Discontinued End Of Support Range Date Date Date 8560EC 2.9 GHz 12-2-1999 9-1-2009 8-31-2014 8561EC 6.7 GHz 12-2-1999 5-1-2004 5-1-2009 8562EC 13.6 GHz 12-2-1999 9-1-2009 8-31-2014 8563EC 26.5 GHz 12-2-1999 9-1-2009 8-31-2014 8564EC 40 GHz 12-2-1999 6-1-2012 5-31-2017 8565EC 50 GHz 12-2-1999 6-1-2012 5-31-2017 8564EC/65EC disco plan announce June 1, 2011
Complete list from www.agilent.com (link) 8560 Series Portable Spectrum Analyzers Model Number Standard Frequency Range Introduced Discontinuance Date End Of Support Replaced By 8560A 50 Hz - 2.9 GHz June 1989 July 1994 October 1999 8560E 8560E 30 Hz - 2.9 GHz June 1992 April 2001 April 2006 8560EC 8560EL 30 Hz - 2.9 GHz November 1997 April 2001 April 2006 8560EC 8560EC 30 Hz - 2.9 GHz December 1999 September 2009 August 2014 MXA, PXA 8561A 1 khz - 6.5 GHz September 1988 August 1991 August 2001 8561B 8561B 50 Hz - 6.5GHz June 1989 July 1993 July 1998 8561E 8561E 30 Hz - 6.5 GHz June 1992 April 2001 April 2006 8561EC 8561EC 30 Hz - 6.5 GHz December 1999 May 2004 April 2009 MXA, PXA 8562A 9 khz - 22 GHz February 1987 October 1994 April 2000 8563E 8562B 9 khz - 22 GHz February 1987 July 1993 July 1998 8563E 8562E 30 Hz - 13.2 GHz June 1996 April 2001 April 2006 8562EC 8562EL 30 Hz - 13.2 GHz November 1997 April 2001 April 2006 8562EC 8562EC 30 Hz - 13.2 GHz November 1999 September 2009 August 2015 MXA, PXA 8563A 9 khz - 26.5 GHz November 1989 December 1997 December 2002 8563E 8563E 9 khz - 26.5 GHz June 1992 April 2001 April 2006 8563EC 8563EC 9 khz - 26.5 GHz December 1999 September 2009 August 2015 MXA, PXA 8564E 9 khz - 40 GHz November 1993 April 2001 April 2006 8564EC 8564EC 9 khz - 40 GHz December 1999 June 2012 May2017 PXA /EXA 8565E 9 khz - 50 GHz December 1993 April 2001 April 2006 8565EC 8565EC 9 khz - 50 GHz December 1999 June 2012 May 2017 PXA /(EXA up to 44 GHz)
Key Questions to Consider in Migration from 856x 1. Form Factor Physical size? Class 3 MIL Rugged? 2. Hardware Functionality Did you use the Tracking Generator Internal for 8560A/E/EC OPT 002? External 85640A? Did you use External Mixing? Did you use the VIDEO output (standard)? Why? Did you use the second IF output (OPT 001)? Why? Did you used the SWEEP output (standard)? Why? 3. Hardware Performance Phase Noise Performance? Other? 4. Backward Code Compatibility and Applications Coverage Is the 856x in an automated environment? Were you using the Phase Noise Personality (85671A)? Were you using the Spurious Measurements Personality (85672A)? 5. Additional Features Security Clearing Procedures? Calibration Cycle and Cost of Ownership?
1. Form Factor: Physical size Standalone Dimensions 856x MXA/EXA PXA ESA Width (W) 337 mm 427mm 426 mm 373 mm Height (H) 187 mm 173mm 177 mm 222 mm Depth (D) 461 mm 369 mm 556 mm 409 mm Rack mounted Dimensions 856x MXA/EXA PXA ESA Height (H) 5U (223 mm) 4U (178 mm) 4U (178 mm) 5U (223mm) Depth (D) See above See above See above See above NOTE: 1U rack height = 1.75 inches, or 44.5mm NOTE: For visual drawings of these dimensions please see the appendix
2. Hardware Functionality Options 856x Signal Analyzer X-Series PSA Series ESA-E Series Attenuator Pre-Amp Standard Mechanical 70dB (10 db steps) - RF/MW 60db (10 db steps) - mmw Optional External (84474A, 8447D, 8449B, 10855A, 83006A, 83051A) Standard Mechanical 70dB (10/2dBopt) Optional Electronic- EA3 24dB (1dB) options available depending on instrument/frequency Standard Mechanical 70 db (2 db steps) Optional Electronic- B7J 40 db (1 db step) Option 1DS (up to 3 GHz) and option 110(up to 50 GHz) Standard Mechanical 65dB (5 db steps) Power Suite 1 standard measurement 7 standard measurements 10 standard measurements 10 standard measurements Precision Freq Ref Standard for PXA/MXA, OPT Standard (Ext Ref in Range) PFR for EXA Standard 1D5 Narrow RBW Standard Standard Standard 1DR Time gating Standard Standard Standard 1D6 ACPR DR extension 8563E E35 Standard Standard 120 Remote Connectivity Analog VIDEO Output GPIB - Standard B70 Benchlink SA SW Standard GPIB / LAN / USB - Standard Remote Desktop & Embedded Web Server Option YAV on PXA, or Option YAS on MXA/EXA GPIB / LAN Standard 230 Web Remote SW Option 124 1DS GPIB - Standard 230 Web Remote SW E4444A Benchlink SA SW A4J/AYX IF Output Was not offered Option CRP H70, H25, H20, HY7 A4J/AYX and H70 Second IF Output (310.7MHz) Option 001 Option CR3. Standard 321.4 MHz Not Available Sweep Output Standard Not available at this time. Not available at this time. A4J/AYX Tracking Generator External Mixing 8560A/E/EC OPT 002 85640A (external)* Standard in 856x Supported to 325GHz TG option only available on CXA. May consider Opt ESC on MXA/EXA Only available on PXA (Opt EXM) Not available in MXA/EXA External Source Control: Option 215 Security Options Procedures available OPT SSD OPT 117 Procedures available AYZ 1DN AYZ * NOTE: There are no plans to obsolete the TG at this time
3. Hardware Performance: Key Specifications 856x MXA PXA TOI <3 GHz +11 dbm +16 dbm +22 dbm DANL @ 13 GHz -145 dbm/hz -148 dbm/hz -149/-155* dbm/hz Noise @ 10kHz offset -113 dbc/hz -103 dbc/hz -129 dbc/hz (1GHz cf) -106 dbc/hz typical Accuracy (95%) +/-1.3 db +/- 0.3 db +/- 0.19 db (up to 3 GHz) Min Resolution BW 1 Hz 1 Hz 1 Hz Analysis Measurement BW N/A (No digital Demod) 10 MHz (25/40 MHz opt) 10 MHz (25/40/140 MHz opt) Measurement Rate 7/sec > 100/sec > 100/sec NOTE: The 856x series has great phase noise performance. This is the #1 specification that you need to qualify to help your customers migrate
mmw SA migration To be disco ed June 1, 12 To be introduce May 1, 12 Introduced Apr 1, 2010 Key Specifications Conditions 8564/5EC mmw EXA Signal Analyzer mmw PXA Signal Analyzer Frequency range 30 Hz to 40/50 GHz 10 Hz to 32/44 GHz 3 Hz to 43/44/50 GHz TOI 2 GHz 12 GHz 44 GHz +11 dbm +7.5 dbm 12.5 dbm (nom) +15 dbm +15 dbm +13 dbm (nom) +21 dbm +15 dbm +13 dbm (nom) DANL (1 Hz RBW, Preamp off) 2 GHz 12 GHz 44 GHz -145 dbm -143 dbm -127 dbm -151 dbm -147 dbm -135 dbm NFE* LNP** -162 dbm -154 dbm -153 dbm -147 dbm -140 dbm Φ Noise, 1GHz 44 GHz (nom) Amplitude Acc (Flatness to 40 GHz) 10 khz offset -113 dbc/hz -103 dbc/hz, (Typ. -106 dbc/hz) -129 dbc/hz 95 dbc/hz -87 dbc/hz (measured) -110 dbc/hz ±4 db ±3.2 db ±3.2 db Analysis BW - 10, 25 MHz 10, 25, 40, 140 MHz Speed rating * NFE = Noise Floor Extension technology; (applies also to LNP in high band) ** LNP = low noise path
3. Hardware Performance: Phase Noise NOTE: Only the nominal performance are given for MXA/EXA @1 khz and 10 MHz offsets
4. Backward Code Compatibility: 856x to X-Series N9061A Remote Language Compatibility Application Emulates the HP/Agilent 856xE/EC remote programming language Supports the most frequently used 856xE/EC commands Available with new X-Series signal analyzers (PXA/MXA/EXA) as a standard feature Has command error logging Areas of Caution: Does not cover commands for: 856x Phase Noise Utility 856x Spurious Utility Click HERE to download a free 14-day Trial License for N9061A
General Purpose WINET Wireless 4. Applications Coverage Application 856x Signal Analyzer X-Series GSM/EDGE Not available N9071A W-CDMA 8563E-E35 N9073A-1FP, -2FP HSDPA/UPA Not available N9079A-2FP cdmaone + cdma2k Not available N9072A TD-SCDMA HSDPA/8PSK Not available N9079A-1FP WiMax (OFDMA) Not available N9075A WLAN Not available N9064A VXA LTE Not available N9080A Bluetooth Not available 89600B Phase Noise* 85671A N9068A Spurious Measurement* 85672A Power Suite** Noise Figure Not available N9069A Cable/Digital TV Not available Digital TV available AM/FM demodulation and metrics Tune and Listen ONLY N9063A NO Metrics Tune, Listen, Metrics VSA Not available N9064A VXA or 89600B internal/external Modulation Analysis Not available 89600 B VSA Flexible Digital Demod Not available N9064A native or 89600B embedded * NOTE: 85671/85672 personalities will continue to be available and will not be discontinued at this time * *NOTE: Power Suite in X-Series, PSA, or ESA partially covers 85672A functionalities. See NOTES for this slide for more information.
5. Additional Features: Security Clearing Procedures In General: Go to www.agilent.com/find/security and enter the model number of your instrument. 856x: http://cp.literature.agilent.com/litweb/pdf/08560-90174.pdf PXA/MXA/EXA: Additional removable Solid-State Drive (Option SSD) PXA/MXA/EXA removable solid-state drive (standard)
5. Additional Features: Calibration Cycle & Cost of Ownership Description 856x MXA/EXA PXA Calibration Cycle 2 years (MXA) 2 years 2 years (EXA) 1 year Agilent Calibration Cost (Return to Agilent) ~$787 ~$716 ~$787 Repair Cost (Return to Agilent) Agilent TME Software Available? ~$4629 ~$3384 (MXA) ~$1138 (EXA) ~$4315 NO YES YES Example is for a 26 GHz analyzer, prices were quoted in Aug 08 Z540 and ISO 17025 calibration also available at additional charge Agilent TME Calibration Software is available at: http://www.calsw.tm.agilent.com/
X-Series Signal Analyzers The next generation of signal analysis Drive your evolution Accelerate in wireless Balance the challenges N9010A EXA N9020A MXA Master the essentials N9000A CXA N9030A PXA Stay ready, stay in sync and arrive ahead with the Agilent X-Series
Customer Success Story Market CATV / Telecommunications Device Cable Head End Transport System Test Manufacturing (GP Spectrum Analysis) Existing Method 8560 New Method MXA Headline We were able to reduce our test time by 60% on two separate production lines at our facility
856x to MXA and PSA signal analyzer $15,000 Trade-in deal NEW Eligible Models 8560A/E/EL/EC, 8561A/B/E/EC, 8562A/B/E/EL/EC, 8563A/E/EC, 8564E/EC, 8565E/EC Minimum Trade-in Credit towards MXA or PSA $15,000 Receive a $15,000 minimum credit when you trade an eligible 856x portable spectrum analyzer toward a MXA midrange signal analyzer or a PSA performance spectrum analyzer. Compared to the 856x, the MXA offers significantly higher measurement speed, increased measurement accuracy and enhanced usability. In addition, remote language backward compatibility is supported through the new N9061A application. More Information: http://www.home.agilent.com/agilent/editorial.jspx?cc=us&lc=eng&ckey=1520997&nid=- 536900129.536883223.02&id=1520997 Expires: act soon - this trade-in credit is good only for a limited time.
856xE/EC Migration Assistance Link to agilent.com
Appendix Environmental Specifications Schematics of Instruments
1. Form Factor: Environmental Specifications: 856x EC SOURCE: 856x Data Sheet (see link at end of presentation)
1. Form Factor: Environmental Specifications: PSA NOTE: PSA is tested to MIL-PRF-28800F Class 3 NOTE: Temp range is similar as the 856x Series is NOTE: PSA is heavier than the 856x series 856x is ~36lbs. PSA is ~50lbs. SOURCE: PSA Data Sheet (see link at end of presentation)
1. Form Factor: Environmental Specifications: ESA NOTE: ESA is tested to MIL-PRF-28800F Class 3 as the 856x Series is NOTE: Temp range is the same NOTE: ESA is a bit heavier than the 856x series 856x is ~36lbs. ESA is ~38lbs. SOURCE: ESA Data Sheet (see link at end of presentation)
1. Form Factor: Environmental Specifications: MXA/EXA NOTE: MXA/EXA are not officially tested to MIL-PRF-28800F Class 3 as the 856x is. NOTE: MXA/EXA are tested to a different temperature range than the 856x is. NOTE: MXA/EXA are comparable to the weight of the 856x. SOURCE: MXA Specs Guide (N9020A-90027)
Form Factor: Base Box: 856xEC
Benefits of all-digital final IF PXA, MXA, EXA are all based on a digital IF architecture. Key Advantages: 1. Improved performance 2. Frequency and amplitude accuracy 3. Measurement speed, 4. Improved frequency resolution. See these links for more information: Spectrum Analyzer Basics (AN 150) (5952-0292) http://cp.literature.agilent.com/litweb/pdf/5952-0292.pdf PSA Performance Spectrum Analyzer series: Amplitude Accuracy (5980-3080EN) http://cp.literature.agilent.com/litweb/pdf/5980-3080en.pdf PSA Performance Spectrum Analyzer series: Swept and FFT Analysis (5980-3081EN) http://cp.literature.agilent.com/litweb/pdf/5980-3081en.pdf
Form Factor: Base Box: MXA / EXA
Tools for Maintenance and Calibration Standard-compliant calibration services available: N90x0A-A6J: ANSI Z540 compliant calibration from Agilent factory N90x0A-1A7: ISO 17025 compliant calibration from Agilent factory Z540.3-2006 capable Annual Calibration: Agilent wants you to have a positive support experience TWO YEAR calibration cycle on PSA SG/MY/US 4430 and above with our instruments regardless of whether: You return them to Agilent Agilent Calibration Pricing You perform your own maintenance TME Calibration and Adjustment Software PSA Overview
TME Calibration Software for Self Maintainers Product Structure & Pricing Service center PC seat license US$ 4995 1st year per PC (N7800A-U1S) US$ 4000 Annual renewal per PC (N7800A-U1R) Z540.3-2006 capable Universal model perpetual license for one instrument US$ 850 (N7800A-UPZ) Universal model per-incident (90-day) licenses (US only) US$ 100 Agilent Commercial Calibration (N7800A-U9C) US$ 135 Agilent ISO 17025 / ANSI Z540 Calibration (N7800A-U9Z) PSA Overview