PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

Similar documents
Programmable Power Supplies 188 W 384 W R&S HMP Series

2 MHz Lock-In Amplifier

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

Display Information Type Backlit blue on white STN Type

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832)

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Single-Output 2000 W

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Hybrid Chart Recorder 250 mm (10")

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

LAUREL ELECTRONICS, INC.

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

OPTICAL POWER METER WITH SMART DETECTOR HEAD

R&S RT-ZVCxx Multi-Channel Power Probe Specifications

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE


MAP110 AC-DC Series Data Sheet

R3267/3273 Spectrum Analyzers

R-1580A Microwave Downconverter. Product Brochure

MICROWAVE MEASURING INSTRUMENTS

R&S RT-Zxx High-Voltage and Current Probes Specifications

PicoScope 6407 Digitizer

Digital Storage Oscilloscopes 2550 Series

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

GFT Channel Digital Delay Generator

Data Pattern Generator DG2020A Data Sheet

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

PicoScope 6407 Digitizer

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

Type Contact form Model

Signal Stability Analyser

Digital output modules

Data Pattern Generator

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

Clamp 200 A AC/DC (+ V AC/DC + Ω)

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Kramer Electronics, Ltd.

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

TABLE OF CONTENTS. Instructions:

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

USER S MANUAL. FX2N-8AD Analog input block

R&S RT-Zxx High-Bandwidth Probes Specifications

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

SAFETY TERMS AND SYMBOLS

TempScan/1100 & MultiScan/1200

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Stability, Speed and Accuracy

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

WaveDriver 20 Potentiostat/Galvanostat System

Optical Test and Measurement System AQ8200 Series

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

Process Transmitter RMA 422

2 MHz Lock-In Amplifier

ScopeMeter 190 Series Specifications

Stereo Box Pre Box Amp Box Amp Box Mono Switch Box. Tuner Box Dock Box F / V Phono Box MM Record Box USB Phono Box II

AI-1204Z-PCI. Features. 10MSPS, 12-bit Analog Input Board for PCI AI-1204Z-PCI 1. Ver.1.04

WVR500 Waveform/Vector Monitor

Satellite Up- and Downconverter

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

Microwave Counter, Power Meter and DVM in One Portable Package

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

Procurement of IC TESTER & TRAINER KITS, OSCILLOSCOPES, FG S, DECADE BOXES AND ANALOG METERS

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

We bring quality to light. SNT 10 DC Power Supply

4 MHz Lock-In Amplifier

Truck router (3Gbps/HD/SD/ASI)

R&S TS-PSU12 Power Supply/Load Module Four-quadrant source with integrated measurement unit

Routing Swichers 248

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

A/D and D/A convertor 0(4) 24 ma DC, 16 bits

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Specifications. Reference Documentation. Performance Conditions

HIGH QUALITY AUDIO DOLBY NR

Simple all-in-one design style with front stereo speakers and natural ventilation system

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Broadcast and Professional Monitors

DA E: Series of Narrowband or Wideband Distribution Amplifiers

DA : Series of Narrowband or Wideband Distribution Amplifiers

Part 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories

Model 1421 Distribution Amplifier

Interfaces and Sync Processors

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Level Measurement silometer FMC 420, FMC 423

Automated Local Loop Test System

G.R.A.S. Sound & Vibration

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

Transcription:

Programmable DC Source Sink and Source Capability Conventional DC sources usually have the function of power supply (source) only without power absorption (sink) function. In addition to the source function, the sink is available, so the can be used for the discharge characteristics of batteries or the output characteristics of power supply as a constant current electronic load. Further, the 4-quadrant operation becomes available by sink and source function, so both capacitive and inductive loads can be driven by the. The is a general-purpose DC source developed on YOKOGAWA s state-of-the-art DC standard technology. The dual multiplying D/A converter has enabled the compatibility of highspeed response and high resolution. The also provides high accuracy and stability. In addition to the source function (current supply), the sink function (current absorption) is also available, so the can be used as not only DC voltage/current source but also high-precision electronic load. Further, a series of powerful functions to meet the system use such as the programming function up to 50 steps, the IC memory card capable of storing 7 patterns of programs, and GP-IB interface are provided as standard. This can be used for a wide range of fields from R & D to production line, service and maintenance. FEATURES High Precision High accuracy : ± 0.0% of setting ±200 µv (0 V range, 90 days, 23 ± 5 C) ± 0.02% of setting ± 00 na ( ma range, 90 days, 23 ± 5 C) High resolution : 00 nv (DC V, 0 mv range) High-speed response : 0 ms/± 0.% Low noise : 5 µvp-p ( V range, DC to 0 Hz) Data from CPU 23 88 350 mm 3.6 kg (8-7/6 3-/2 3-3/6" 7.92 lbs) Primary D/A Converter Secondary D/A Converter Dual Multiplying D/A Converter The uses multiplying D/A converter technology. Extremely high resolution is realized through the use of dual digital to analog converters. In addition, the linearity is further enhanced by software driven compensation technique. Superior output with high accuracy is assured in all the ranges. n Buffer amplifier E E 2 sink operation. The generation of constant voltage is possible even with active load. Sink As a Reliable Constant Voltage Source Hi Lo Sink operation Constant current discharge characteristics Discharge Characteristics Test of Battery Capacitive load I Resistive load Inductive load Source Sink 4-quadrant Operation Source Bipolar, Glitchless The bipolar output of the executes polarity switching without using mechanical contact, so any abnormal voltage or current is not generated at the polarity switching. Because of this feature, true continuous output change from the negative maximum output to the positive maximum output becomes possible. An evaluation of zero cross comparator or polarity switching for the cancellation of emf in experiments of solid-state physics can easily be made. A glitch is not generated at the change of voltage or current in the same range. Hi Lo 7555/7560

V = I R + E V 2 = I R + E V V 2 = 2I R Resistance Measurement of Superconductivity Programming Function and IC Memory Card FUNCTIONS EASY-TO-OPERATE DESIGN Two Types of Data Setting Mode You can select the following two types of data setting mode in accordance with your application. Continuous variable mode... The setting is made on each digit by depressing the corresponding up/down key. When you continue depressing the up/down key, the output value changes continuously. Data mode... The setting data are directly entered by ten-key. Examples of Pattern by Program Setting By combining the programming function of the with the and 750 programmable scanner, multi-channel measurement can easily be performed. Ready signal of Ready signal of 750 EXT. TRIG 7555,7562 EXT. TRIG END signal of PROGRAMMING FUNCTION: 50-STEP OUTPUT DATA CAN BE STORED. Up to 50 steps of output data can be saved. In addition to setting of generation interval, sweep time can also be set, and various output patterns including step response, ramp response, and triangle waveform can be generated by combining these capabilities. Up to 7 output patterns can be stored in the IC memory card. The memory card is a convenient method for providing a variety of generation patterns. Programming setting Manual setting... by panel key operations Remote setting... by GP-IB interface. AUTO LOAD setting... the memory contents are automatically read and programmings are set at power ON. TRIG. DUT DUT 750 Programmable Scanner Example of Multi-channel Measurement System Evaluation test of amplifier DC characteristics can be made by supplying input signal to the amplifier from the and reading output of the amplifier by the. The efficiency of measurement will be improved by utilizing the programming function. AMP 7555, 7562 Example of Amplifier Characteristics Evaluation Test

from the Front or Rear is Selectable In addition to the front output terminal model, the includes the rear output terminal model. This allows the use of the where mounted on a bench or on a rack. Programmable Voltage/Current Limiter Limiting point is programmable within the range of to 30 V as the voltage limiter, and within the range of 5 to 20 ma as the current limiter. Even if the limiter is actuated by overload or short-circuit of output and so on, the automatically recovers from limit to normal state by removing the overload. Calibration Function Calibration software is integrated in the, and calibration is executed by the key operation on the front panel or through communication without opening the case. So, anyone can maintain the accuracy of the without difficulty by its calibration function. GP-IB Interface (Standard) The GP-IB interface can be selected according to your system needs. The following functions are available through these interfaces. Functions executed by panel key operation Setting data output Panel set data output Program step setting/reading Status byte output SPECIFICATIONS DC VOLTAGE (DC V) Maximum Maximum Current ± 20 ma ± 20 ma ± 20 ma Resolution Stability (24 h) Stability (90 days) Accuracy (90 days) Accuracy ( year) Temperature ±(% of setting ±(% of setting ±(% of setting ±(% of setting Coefficient + µv) + µv) + µv) + µv) ±(% of setting + µv)/ C 0 mv ±2.0000 mv 00 nv 0.002 + 3 0.04 + 4 0.08 + 4 0.025 + 5 0.008 + 0.7 00 mv ±20.000 mv µv 0.003 + 3 0.04 + 5 0.08 + 0 0.025 + 0 0.008 + 0.7 V ±.20000 V 0 µv 0.00 + 0 0.008 + 50 0.0 + 00 0.06 + 20 0.0009 + 7 0 V ±2.0000 V 00 µv 0.00 + 20 0.008 + 00 0.0 + 200 0.06 + 240 0.0008 + 0 30 V ±32.000 V mv 0.00 + 50 0.008 + 200 0.0 + 500 0.06 + 600 0.0008 + 30 The stability (24 h) is the value at 23 ± C. The stability (90 days), accuracy (90 days) and accuracy ( year) are values at 23 ± 5 C. The temperature coefficient is the value at 5 to 8 C and 28 to 40 C. 0 mv 00 mv V 0 V 30 V DC CURRENT (DC A) Maximum Resistance approx. 2 Ω approx. 2 Ω Resolution Noise DC to 0 Hz DC to 0 khz (Reference Data) 3 µvp-p 30 µvp-p 5 µvp-p 30 µvp-p 5 µvp-p 60 µvp-p 50 µvp-p 00 µvp-p 50 µvp-p 200 µvp-p Stability (24 h) Stability (90 days) Accuracy (90 days) Accuracy ( year) Temperature ±(% of setting ±(% of setting ±(% of setting ±(% of setting Coefficient + µa) + µa) + µa) + µa) ±(% of setting + µa)/ C ma ±.20000 ma 0 na 0.005 + 0.03 0.06 + 0. 0.02 + 0. 0.03 + 0. 0.005 + 0.0 0 ma ±2.0000 ma 00 na 0.005 + 0.3 0.06 + 0.5 0.02 + 0.5 0.03 + 0.5 0.005 + 0. 00 ma ±20.000 ma µa 0.004 + 3 0.06 + 5 0.02 + 5 0.03 + 5 0.002 + The stability (24 h) is the value at 23 ± C. The stability (90 days), accuracy (90 days) and accuracy ( year) are values at 23 ± 5 C. The temperature coefficient is the value at 5 to 8 C and 28 to 40 C. ma 0 ma 00 ma Maximum Voltage Resistance more than 00 MΩ more than 00 MΩ more than 0 MΩ Noise DC to 0 Hz DC to 0 khz (Reference Data) 0.02 µap-p 0. µap-p 0.2 µap-p 0.3 µap-p 2 µap-p 3 µap-p Common mode rejection: 20 db or more (DC, 50/60 Hz). Common mode rejection: 00 na/v or more (DC, 50/60 Hz).

Response Time Delay time: Approx. 0 ms (For the fixed range). Response time: Less than 0 ms to within ±0.% of set value, at the max. output and max. load, without actuation of limiter, with resistive load. Limiter Maximum Resolution Description Current limiter 5 to 20 ma ma At voltage output Voltage limiter to 30 V V At current output After limiter actuation, automatic recovery from limit status is executed by removal of overload. Data Setting Continuous variable mode (set by each digit by up/down keys) Data mode (set directly by ten-key) Interface Function GP-IB interface: Electrical and mechanical specifications: Conforms to IEEE St d 488-978 Interface function & identification: SH, AH, T6, L4, SR, RL, PP0, DC, DT, C0 Address mode: Address setting, Header ON/OFF are settable Programming Function Internal memories: Stores settings up to 50 steps IC memory card: Stores 7 patterns of programs, each program can store settings up to 50 steps (IC memory cards; 8K bytes, optional) Program actuation by external trigger Interval time/sweep time (by each pattern) Setting Resolution Interval time (Ti) 00 ms to h 00 ms Sweep time (Ts) 0 to h 00 ms Ts Ts GENERAL SPECIFICATIONS Operating Principle: Multiplication type dual D/A conversion Setting: +20,000 (setting range), continuous variable mode, data mode Display: 7-segment LED Unit Indication: 5 x 7 dot-matrix LED, mv/v/ma Overload Indication: -ol- sign display Allowable Input Voltage: 32 V/20 ma between Hi-Lo, 42 V peak between Lo-G, 500 V peak between G-Case Operating Temperature : 5 to 40 C (4 to 04 F) Humidity : 20 to 80% R.H. Warm-up Time (approx.): 60 minutes Power Supply*: 00/5 V AC ±0%, 50/60 Hz, selectable by switch * As to source voltage 200/230 V, prescription is needed. Changeover operable. Power Consumption (approx.): 30 VA Dimensions (approx.): 23 (W) x 88 (H) x 350 (D) mm, (8-7/6 x 3-/2 x 3-3/6") Weight (approx.): 3.6 kg (7.92 lbs) STANDARD ACCESSORIES No. 2 3 4 5 6 7 Fuse* Name Remote connector Instruction manual Power supply cord* * Specified one. Part No. A07EF A04EF A003JD A006WD A253JZ A006WD A009WD A024WD A023WD Q ty Description 0.35 A, 00 V 0.6 A, 200 V 00 V series (JIS standard) 5 V series (UL standard) 200 V series (VDE standard) 230 V series (AS standard) BS standard Ti Ti Execution mode: SINGLE... Executes programmed pattern only once REPEAT... Repeats the execution of programmed pattern External Trigger Signal steps actuation of program can be executed by external trigger. Ready output: Suitable for system use

AVAILABLE MODELS Model 0 Power Requirements Suffix Codes Option Codes -A Power Cord - -3-5 -7 /M /D /F /R /J Description With front output terminal, GP-IB With rear output terminal, GP-IB Always A (version code) 00 V AC (50 & 60 Hz), 5 V AC changeable 5 V AC (50 & 60 Hz), 00 V AC changeable 200 V AC (50 & 60 Hz), 230 V AC changeable 230 V AC (50 & 60 Hz), 200 V AC changeable JIS standard UL standard VDE standard AS standard BS standard DIMENSIONS < Rack Mounting > Front Model Unit: mm (inch) OPTIONAL ACCESSORIES FOR No. Code Name Order Q ty 8 37890 IC memory card (setting data), 8 K bytes unit ( pc./unit) B9586NG Dummy card (Dust cap for IC memory card slot), 2 pcs./unit unit (2pcs./unit) 9 B9409LA Test leads (alligator type, 0.8 m) 7550 Rack mounting kit (EIA, single mounting) unit 75502 Rack mounting kit (EIA, double mounting) (pc./unit) 75503 Rack mounting kit (JIS, single mounting) 75504 Rack mounting kit (JIS, double mounting) EIA (double mounting) EIA (single mounting) 8 IC memory card (37890) 9 Shielded test leads (B9409LA) JIS (double mounting) JIS (single mounting)