Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

Similar documents
Pendant Light Fitting IEC Series 6470/2

Illustrated Feature. Options

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

Pendant Light Fittings Series 6050

PRE Series 16 Amp Plugs and Sockets Increased Safety

LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances

Champ-Pak Wall Pack Luminares

EXLUX ECOLUX 6480 Series

EXLUX ECOLUX C-LUX 6480 Series

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

7 Lighting Technology

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

EXPlora. Introduction

Operating instructions

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations

I Ex-protected connectors exlink I

M A R I N E B R I G H T S O L U T I O N S

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

SubstiTUBE Value EM ST8V-1.2m-17W-EM

8 Installation Equipment

XML LED X M L L E D. Explosionproof Linear LED Lighting

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Features. Specifications. Finish. Notes

Philips Corepro LEDtube T8

Applications. Standard Materials

SubstiTUBE Value ST8V-0.6m

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Inductive sensor With analog output BI15-M30-LI-EXI

SubstiTUBE Advanced UO EM ST8AU-1.5m-24W-EM

Explosion Proof Audible Signal db(a) Series YA60

SubstiTUBE Value ST8-HV5

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Explosion Proof Audible Signal db(a) Series YA60

Cylindrical Photoelectric Sensor CY-100 SERIES

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

WEATHERPROOF LUMINAIRE

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

LIGHTING SOLUTIONS. The bright side of the ship

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure


Flow Measurement SITRANS F M

Pressure transmitter For applications in hazardous areas Model IS-3

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Inductive sensor BI1.5-EG08K-Y1

WLC60 Heavy Duty LED Light - PWM Dimmable

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

WLB SERIES HID Lighting for Hose Down Applications

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

SubstiTUBE Value EM Fighter Tube Technical Datasheet

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Emergency lighting units EM INVERTER

SubstiTUBE Advanced ST8-HA4

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Champ VMV LED luminaires for hazardous areas

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Inductive sensor NI3-EG08K-Y1-H1341

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

TFRN Industrial RTD temperature sensor. CombiTemp TM

Liner Quattro AC XB RGBW

STB Distribution Box Screw or IDC Type Indoor DP Outdoor DP Wall & Pole DP Pillar DP

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

S020 fluorescent tube luminary

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Level Measurement Point level measurement - RF Capacitance switches

EZ-STATUS WLS28-2 Multicolor LED Strip Light

Inductive sensor NI10-M18-Y1X-H1141

NOXLITE LED SPOT. Product family datasheet. Outdoor LED wall luminaires. Areas of application _ Outdoor _ Garages _ Patios, balconies

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas

Quality products from a single source

ArenaVision MVF404 exceptional optical efficiency

Media Tube HO RGBW. High intensity SMT RGB and White LEDs Million additive RGB colors; White CCT 6500K

T8 LED Tube. UL-Lighting. Features. Certificates. Web:

DMP 331i / DMP 333i LMP 331 i

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM

APPLICATIONS. Automatic warehouse. Trasportation lines

USER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -.

Optical Signal Devices. Free-standing Beacons

Circuit-Breakers for Motor Protection Series 8523/8

LED STADIUM LIGHTING WS-STAD-xxx Gen6

Manufacturer Information EATON CROUSE-HINDS INDUSTRIAL PRODUCTS GTIN Manufacturers Part Number

3 Large Housing. Assembly Guide. To order a UNIPAK fixture, see page 29. Complete luminaire consists of : To order separate components, order

EZ-LIGHT K90FDL Daylight Visible

LED HIGHBAY I-VALO XENRE

Coils for solenoid valves

APPLICATIONS. Automatic warehouse. Trasportation lines

Modular Lube Lubrication Systems System Controls

Media Tube HO RGB. 896mm mm mm kg 1.8lbs. 0.4kg 0.9lbs. 1.24kg 2.7lbs. 1.02kg 2.3lbs

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Transcription:

ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof 2 x 58 W Compliance Data: ATEX IECEx: ATEX IECEx CE Ex d IIB Ex d IIC T6 to T4 Ex td A21 T78 C to T130 C (10 meters) Ex d IIB+H2 Power and Voltage: 18 W / 36 W / 58 W Multiple Voltages amp Type 1, 2, 3 amp Versions 220 V-60 Hz / 230 V-60 Hz / 230 V-50 Hz / 240 V-50 Hz Fluorescent: T8 (G13) T5 (G5) 110 to 254 Vac/Vdc +/- 10% 50/60 Hz Compact Fluorescent: TC- (2G11) Operating Temperature: -20 C to +55 C 18

ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof Applications: Can be installed in hazardous areas designated as Zone 1, 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against dirt, water and moisture is necessary. Typical applications include oil refineries, petrochemical facilities, pulp and paper, mills, painting, sewage and water treatment facilities, warehouses, underground tunnels and general manufacturing facilities. Features: Impact resistant borosilicate glass sealed tube. Easy access to lamps through gray painted Zamak threaded entry cap. Supplied with O-ring for improved ingress protection. Corrosion-resistant gray painted Zamak. Supplied with energy efficient and self induction ferromagnetic ballast on a removable gear tray. Quick and easy installation of fluorescent lighting fixtures with 2G11 and G13 lamp holders. Supplied with external and internal ground/earth connection. Fixture supplied with one M20 blanking plug. Easy connection to wire and disconnect with plug-in terminal blocks. Bi-pin (G13) 18 & 36 W magnetic ballast versions operate at +70 C ambient temperature with T4 rating. Magnetic ballast versions 230 V 50 Hz or 240 V 50 Hz or 220 V 60 Hz or 230 V 60 Hz. Electronic ballast versions 110 to 254 Vac/Vdc 50/60 Hz. 3 hour emergency version with automatic self test every month Plug in battery pack (6 V 4 Ah) is easy to remove for maintenance. 2 x 58 W Standard Material of Fixtures: Gray painted Zamak end caps and cover. Borosilicate glass tube. itrile (BR) O-ring gasket. White powder coated galvanized steel internal reflector. Standard Material of Mounting Accessories: Several accessories in different material such as zinc plated steel, galvanized steel or 316 stainless steel. Options: 3 lamp versions. 8 W fluorescent (Bi-pin G5) available, see section HBDC series. Catalog umber ogic: FD X X XX X X X Series: Zone 1 & 2-21 & 22 ATEX / IEC certified umber of amps: 1 = Single 2 = Double 3 = Three amps amp Type: B = Bi-pin (G13) Fluorescent C = Compact Fluorescent (2G11) F = Bi-pin (G5) Fluorescent Wattage: 18 = 18 Watt 36 = 36 Watt 58 = 58 Watt Cable Entry: M = Metric M20 = PT 3/4" Voltage (50/60 Hz): Standard versions: AA = 220 Vac 60 Hz AC = 230 Vac 60 Hz XC = 230 Vac 50 Hz X3 = 240 Vac 50 Hz BU = 110 to 254 Vac/Vdc 50/60 Hz Emergency versions: BU = 110 to 254 Vac/Vdc 50/60 Hz Options: (Options must be listed alphabetically) E = 3h Emergency (combined) Battery 6 V 4 Ah 19

ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof Ordering Information Standard Versions: Two M20 threaded entries, supplied with one M20 aluminum blanking plug. Connection via 1 x 3 double deck terminals. Capacity (flexible/solid): 0.75 mm 2 to 2.5 mm 2. For Bi-pin (G13) Fluorescent amps - T8 (26 mm) or T12 (38 mm) 230 V - 50 Hz Magnetic Ballast Starter Ignition o. of Power Gas Weight Volume Catalog Old Catalog amps (W) Group Model (kg) (dm 3) umber umber Pack 1 18 IIC 0.6 9 58 FDB118XCM 1 2 18 IIC 0.6 9.7 58 FDB218XCM 1 1 36 IIB+H2 1.2 14.7 99 FDB136XCM 1 2 36 IIB+H2 1.2 15.3 99 FDB236XCM 1 1 58 IIB 1.5 17 119 FDB158XCM 1 2 58 IIB 1.5 18.2 119 FDB258XCM 1 240 V - 50 Hz Magnetic Ballast Starter Ignition 1 18 IIC 0.6 9 58 FDB118X3M 094826 1 2 18 IIC 0.6 9.7 58 FDB218X3M 094829 1 1 36 IIB+H2 1.2 14.7 99 FDB136X3M 094827 1 2 36 IIB+H2 1.2 15.3 99 FDB236X3M 094830 1 1 58 IIB 1.5 17 119 FDB158X3M 094828 1 2 58 IIB 1.5 18.2 119 FDB258X3M 094831 1 220 V - 60 Hz Magnetic Ballast Starter Ignition 2 18 IIC 0.6 9.7 58 FDB218AAM 094809 1 2 36 IIB+H2 1.2 15.3 99 FDB236AAM 094810 1 2 58 IIB 1.5 18.2 119 FDB258AAM 094811 1 230 V - 60 Hz Magnetic Ballast Starter Ignition 2 18 IIC 0.6 9.7 58 FDB218ACM 094818 1 2 36 IIB+H2 1.2 15.3 99 FDB236ACM 094819 1 2 58 IIB 1.5 18.2 119 FDB258ACM 094820 1 20

ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof Ordering Information Standard Versions Continued: For Bi-pin (G13) Fluorescent amps - T8 (26 mm) or T12 (38 mm) 110 to 254 Vac/Vdc 50/60 Hz Electronic Ballast Power factor > 0.95 o. of Power Gas Weight Volume Catalog Old Catalog amps (W) Group Model (kg) (dm 3) umber umber Pack 2 18 IIC 0.6 9.7 58 FDB218BUM 091807 or 094807 1 2 36 IIB 1.2 15.3 99 FDB236BUM 091808 or 094808 1 3 36 IIB 1.2 16.3 99 FDB336BUM 1 1 58 IIB 1.5 17 119 FDB158BUM 091812 or 094812 1 2 58 IIB 1.5 18.2 119 FDB258BUM 091813 or 094813 1 3 58 IIB 1.5 19.2 119 FDB358BUM 1 For 2G11 Compact Fluorescent amps TC- 230 V - 50 Hz Magnetic Ballast Starter Ignition amps supplied 1 18 IIC 0.3 9 58 FDC118XCM 1 2 18 IIC 0.3 9.7 58 FDC218XCM 1 1 36 IIB+H2 0.6 14.7 99 FDC136XCM 1 2 36 IIB+H2 0.6 15.3 99 FDC236XCM 1 Emergency Versions: Two M20 threaded entries, supplied with one M20 aluminum blanking plug. Connection via 1 x 4 double deck terminals. Capacity (flexible/solid): 0.75 mm 2 to 2.5 mm 2. For Bi-pin (G13) Fluorescent amps T8 (26mm) or T12 (38mm) 110 to 254 Vac/Vdc 50/60 Hz Electronic Ballast 3 hour duration - battery pack 6 V 4 Ah - Power factor >0.95 - Self test every month. o. of Power Gas ine Weight Volume Catalog Old Catalog amps (W) Group Model Output (kg) (dm 3 ) umber umber Pack 2 18 IIC 0.6 29% 11.6 58 FDB218BUME 091815 or 094815 1 2 36 IIB 1.2 16% 17.2 99 FDB236BUME 091816 or 094816 1 2 58 IIB 1.5 11% 20.2 119 FDB258BUME 091817 or 094817 1 21

ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof Accessories: Description Catalog umber Old Catalog umber Pack External Reflector White Painted Galvanized Steel Model 0.3 FDER1G 094868 1 Model 0.6 FDER2G 094869 1 Model 1.2 FDER3G 094870 1 Model 1.5 FDER4G 094871 1 Protective Guard Zinc Plated Steel Model 0.3 FDPG1Z 094872 1 Model 0.6 FDPG2Z 094873 1 Model 1.2 FDPG3Z 094874 1 Model 1.5 FDPG4Z 094875 1 Fixing Brackets for Ease of Surface Installation Set of Two Zinc plated steel FDFBZ 094897 1 316 stainless steel FDFBS 094889 1 Surface Mounting Brackets Set of Two Zinc plated steel FDSBZ 094898 1 316 stainless steel FDSBS 094890 1 Half Clamp Brackets for Pole Mounting Set of Two dia. 42 to 49 mm pole (1-1/4" to 1-1/2" tube) Zinc plated steel FDHC49Z 094899 1 316 stainless steel FDHC49S 094892 1 dia. 60 mm pole (2" tube) Zinc plated steel FDHC60Z 094891 1 316 stainless steel FDHC60S 094893 1 Fall Prevention Kit 1.20 M stainless steel chain FDSCS 093819 1 Wiring Diagram: Mains Power PE ighting Switch 1 PE Standard Fluorescent ighting Fixture ED status: Color Indication Function Green Blinking 1:1 Mains good, battery quick charging O Mains good, battery trickle charging Red Blinking 1:1 o battery connected or something is defective 1 PE Emergency Fluorescent ighting Fixture Flashing 1:10 O Mains faulty, battery empty or lamp defective Mains faulty, output O Emergency Function Diagram: Mains ighting Switch OFF ighting Switch O Switched O OFF o mains, battery completely empty Yellow Blinking 1:1 Mains good, performing self test O Result of self test was not good Switched OFF 22

ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof Compliances: Hazardous Area Gas Dust Certified Type Fd Zones 1 2 21 22 Conforming to ATEX 94/9/CE CE 0081 II 2 G CE 0081 II2 D Symbol of Protection ATEX Symbol of Protection IEC Ex d IIB / Ex d IIB+H2 Ex d IIC Ex td A21 T Rating See table.a. Surface Temperature.A. See table Ambient Temperature -20 C to +55 C CE Declaration of Conformity 50203 ATEX Certificate CIE 97 ATEX 6012 IECEx Certificate IECEx CI 04.0018 Other Certifications GOST Index of Protection (solid and liquid) Impact Resistance (shock) IK08 Internal Volume > 2 dm 3 (2 liters) Standards: Ex standards E / IEC 60079-0; 60079-1; 61241-0; 61241-1 Product standards E / IEC 60598-1; 60598-2-22 EMC standards E / IEC 55015; 61547 Other standards E / IEC 60529 (IP); 62262 (IK) T Rating (Gas) and Surface Temperature (Dust) Table: Model amp Type Gas T Rating Dust Surface Temperature Without External Reflector With External Reflector Without External With External Ta =+40 C Ta =+55 C Ta =+70 C Ta =+40 C Ta =+55 C Reflector Reflector 0.3 Compact Fluorescent 2G11 18 W max. T6 T5.A. T5 T4 95 C 130 C a) Fluorescent G13 Magnetic Ballast T6 T5 T4 T6 T5 97 C 95 C 1 x 18 W / b) Fluorescent G13 0.6 Electronic Ballast T6 T6.A. T6 T5 78 C 95 C 1 x 18 W / / 3 x 18 W c) Compact Fluorescent 2G11 1 x 36 W T6 T5.A. T6 T4 95 C 130 C T5 a) Fluorescent G13 Magnetic Ballast T6 T5 T4 T6 T5 110 C 95 C 1.2 1 x 36 W / b) Fluorescent G13 Electronic Ballast T6 T6.A. T6 T6 78 C 80 C 1 x 36 W / / 3 x 36 W a) Fluorescent G13 Magnetic Ballast T6 T6.A. T6 T5 80 C 95 C 1.5 1 x 58 W / 2 x 58 W b) Fluorescent G13 Electronic Ballast T6 T5.A. T6 T5 84 C 95 C 1 x 58 W / 2 x 58 W / 3 x 58 W Dimensions (mm): 15 150 12 B 77.5 Ø12 89 85 191 A Model A B 0.3 430 335 0.6 745 650 1.2 1365 1260 1.5 1655 1560 23

ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof Photometric Data: Polar curves for a 1000 lm flux, according to F C 71-120 uminaire symbol according to F C 71-121 ongitudinal Transverse Bi-pin (G13) Fluorescent ighting Fixtures 2G11 Compact Fluorescent ighting Fixtures 1 x 18 W Efficiency 75.3% F C 71-121/0: 0.69 H + 0.06 T Efficiency 68.1% F C 71-121: 0.63 G + 0.06 T 3 x 18 W Efficiency 57% F C 71-121: 0.50 G + 0.07 T Efficiency 56.2% F C 71-121: 0.52 G + 0.04 T 1 x 36 W Efficiency 74.3% F C 71-121/0: 0.69 H + 0.05 T Efficiency 61.5% F C 71-121: 0.57 G + 0.04 T 3 x 36 W Efficiency 53.3% F C 71-121: 0.47 G + 0.06 T Efficiency 53.6% F C 71-121: 0.50 G + 0.04 T 1 x 58 W Efficiency 74.5% F C 71-121/0: 0.70 H + 0.05 T 2 x 58 W Efficiency 61.3% F C 71-121: 0.57 H + 0.04 T 3 x 58 W Efficiency 48.5% F C 71-121: 0.44 G + 0.05 T 24