STD800LED Large display panel for photovoltaic systems

Similar documents
MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Sensor technologies Proximity sensors Series ST4. Brochure

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Absolute Encoders Multiturn

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

VITEK VTM-TLM191 VTM-TLM240

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

KACO-display. Wireless Solar Monitoring System. Operating Instructions KACO-display. full of energy...

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

Operating instructions Electronic preset counter Type series 717

CMSDI G-SDI Matrix

Marine LCD Display MV-1504/1704/1904/2104

PLL2210MW LED Monitor

TeamWork Kits Installation Guide

Operating Instructions

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

BENESTON USER MANUAL AHD-ER03H. AHD to HDMI & VGA & AV Converter AHD-ER03H

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

PL2410W LCD Monitor USER'S GUIDE.

3GSDI Audio Embedder

Artistic Licence. moody & moody cv. User Guide. Download the user guide by scanning the following QR code: moody & moody cv User Guide.

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Extender for HDMI over one CAT5

HDMI Cross Converter

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Product information. Front-door station series with video for surface-mount

SCALE & WEIGHT DISPLAYS

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

P-2 Installing the monitor (continued) Carry out as necessary

Phono Amplifier brinkmann «EDISON» Manual.

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

EZ-STATUS WLS28-2 Multicolor LED Strip Light

Model: DT-X24H 23.8" Broadcast Studio LCD Monitor. User Manual. Ver:V1.0.0V00. Please read this User Manual throughout before using.

PLL1920M LED LCD Monitor

True RMS AC/DC Mini Clamp Meter

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

Sunny Boy 700U SOLARTECHNOLOGY. Installation Guide. Photovoltaic, Grid-Tied String Inverter

FOREST SHUTTLE S / L / M RECEIVER

ARS x4 MATRIX SWITCHER Instruction Manual

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

Interface Connectors for Miniature, Portable Terminal Devices

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

MON8-1/SDI 1U 8-Channel SDI Digital Multi-Display Video Monitor

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Figure 1: Device components

HP SMA BFOC. Brief instruction. Version. 4en.

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

Thank you for purchasing a qualiton PHONO preamplifier!

Installing the FOREST SHUTTLE S / L

Technical Specifications

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

User Manual. HDBaseT Wallplate Transmitter over Cat6/6A. Front View Panduit Dr, Tinley Park, IL (708)

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

multi-function meters

Solis Export Power Manager

3M Sensored Termination (15 kv) QX-T15I-vi1-E

EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE MULTITURN ABSOLUTE ENCODERS EAM PROFIBUS

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

CC2000 SERIES SYSTEM CLOCKS / DISPLAYS

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

EZ-LIGHT K30L Series With Independent Push Button Contact

Wall-/Pipe-Mount Level Indicator

Warner Photoscanner MCS-500 Series LED Photoelectric Control

INSTALLATION INSTRUCTIONS RGB / RGBW 24V LED TAPE

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

Multifunction devices

Noise Detector ND-1 Operating Manual

AS-300D Series Smart Bench Scales Owner s Manual

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

Operating Manual. Basic Control BC16. two-channel for eco moon

Installation Guide. HDMI 4x1 Switcher

Wall Plate HDMI over CAT5 Extender with Power Over Cable 1080p 165ft (50m)

MON8-1 1U 8-Channel Multi-Display Video Monitor

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using.

CS-801H HD High Resolution Scaler with 3D

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

User Manual Color video door phone

TeamWork Installation Guide

RS-232 to Multi-Mode Fiber Optic Media Converter

Jinyoung Contech Co., Ltd.

Transcription:

STD800LED Large display panel for photovoltaic systems Installation instructions SolarWorld. And EveryDay is a SunDay. www.solarworld.de

Table of Contents 1 Introduction 3 2 Safety 4 3 Installation of the large display panel 5 4 General connection information 6 4.1 Connection to a current meter with pulsed output 8 4.1.1 Connection information 8 4.1.2 Connection diagram 9 4.1.3 Cable length 9 4.2 Connection to a Sunny Boy Control (Standard, Plus) using RS-485 10 4.2.1 Connection information 10 4.2.2 Connection diagram 11 4.3 Connection to a Sunny Boy Control (Light, Standard, Plus) using RS-232 12 4.3.1 Connection information 12 4.3.2 Connection diagram 13 4.4 Connection to a SolarWorld Suntrol using RS-485 13 4.4.1 Connection information 14 4.4.2 Connection diagram 14 5 Configuration of the large display panel 15 5.1 Settings 16 6 Factory settings 18 7 Technical data 19 2

1 Introduction Congratulations on your decision to purchase our large display panel. The large-scale visualization of measurements or other numeric values makes it easy for you to demonstrate connections and effects to a large audience or to keep a close watch on display values. Please read these installation instructions carefully all the way through before using the large display panel. We hope your presentations will find much success. Our efforts in pursuit of complete customer satisfaction do not end with the sale of our products. We are also there for you during their use. If you have any questions, comments or suggestions, please do not hesitate to let us know. 3

2 Safety Please read before using! > Never connect the display to voltages higher than 12 V. Never connect to AC power. > This unit is made up of sensitive electronic components and must therefore be protected from shock and sudden temperature changes. > Handle the large display panel with care! Avoid impacts to the housing. > We have made every effort to ensure that the contents of these installation instructions are complete and correct. If any errors are found, please bring them to our attention. > All trademarks referenced in this document are the property of their respective owners. > Use only the original power supply. Disconnect power supply from power grid after use. The power supply is not for use in wet conditions! > These instructions are an important component of the product. They contain important information on the operation and handling of the product. Please keep this in mind, particularly if you transfer the display to a third party. Proper use of the Suntrol STD800LED > The purpose of this device is to capture and visualize measured data. > The manufacturer is not responsible for improper or inappropriate use of the product and will not accept any resulting damages or warranty claims. > Please read these instructions all the way through before beginning the installation and initial operation of the large display panel. 4

3 Installation of the large display panel Important Notice: Improper installation of the large display panel can cause severe personal injury or damage to property. The large display panel is intended for wall installation. The large display panel is suitable only for indoor use. Important Notice: Do not install the large display panel above passageways! Gap between holes 746 mm Gap between holes 546 mm Caution: Do not tighten screws too firmly! Glass breakage is not covered under warranty! The stainless steel washer must be positioned directly on the spacer. The washer sits somewhat loosely. 5

4 General connection information Important Notice: Improper connection of the large display panel can cause severe personal injury or damage to property. In particular, the large display panel must never be connected directly to the 230 V AC power grid! After installation, the large display panel must be connected to the power supply and the data source used. The large display panel has various inputs and interfaces: The most common connection options for the large display panel are described instructions. Please use only the connection information according to the required input! Connecting terminal assignment A cable comes out of the back of the large display panel and is assigned as follows: Taster für Konfiguration 1 + 12 V DC; 1 A (red) to + power supply 2 0 V, shield (black) to - power supply and data cable shield 3 RxD (pink) 4 GND (gray) 5 TxD (blue) Connection according 6 DTR (violet) to configuration data 7 Pulse+ (white) 8 Pulse- (brown) 9 Data+ (green) 10 Data- (yellow) 6

Power supply connection (plug-in power supply) The large display panel comes with a plug-in power supply. It reduces the 230 V AC grid voltage to the lower voltage required by the large display panel. The low voltage output (free cable ends) of the power supply is connected to terminal 1 pin 1 (+) and pin 2 (-) of the large display panel. Pay attention to the polarity here. If the power supply cables need to be lengthened, the extension wires should have about a 0.75 mm 2 cross section. After the installation to the large display panel is complete, the power supply is plugged into a 230 V AC outlet. 7

4.1 Connection to a current meter with pulsed output The pulsed input of the large display panel is for connection to floating make-contacts of current meters with a pulsed output or similar. Connection to current-controlled pulsed outputs is not possible. The pulsed input makes it easier to connect to any system, regardless of the component manufacturer. The pulse rate can be adjusted to the current meter used. 4.1.1 Connection information The included supply is connected with correct polarity to terminals 1 and 2. If the power supply cable needs to be lengthened, the wires should have about a 0.75 mm 2 cross section. Please note that the power supply must only be used in dry places!the pulsed output (floating make-contact) of the current meter is connected to terminals 7 and 8 of the large display panel. A shielded cable must be used to connect to the current meter. The size of the cable is not important. Pulse+ (terminal 7) is connected to the positive pulsed output (+) of the current meter. Pulse- (terminal 8) is connected to the negative pulsed output (-) of the current meter. The shield is connected at one end to the large display panel 0V (terminal 2). 8

4.1.2 Connection diagram Current meter (example) roßanzeige Large display panel 1 2 7 8 + Power Netzteil supply Schirm Shield + 4.1.3 Cable length If you are using the current meter with the pulsed output sold by the manufacturer and a shielded cable (e.g., YSTY communication line or LIYCY control line), a distance of 100 m cable length from the current meter to the large display panel is possible. The cable must be laid away from strong current consumers and their feed and outgoing cables. For cable lengths between 100 m and 600 m from the current meter to the large display panel, a separate signal amplifier set can be used. This is available on request. 9

4.2 Connection to a Sunny Boy Control (Standard, Plus) using RS-485 The RS-485 interface is intended to connect a correspondingly equipped Sunny Boy Control using an RS-485 connection for cable lengths up to 1000 m. Important Notice: The Sunny Boy Control must be configured for operation with the large display panel. Settings: Display type HvG, baud rate 2400 (for details, see Sunny Boy Control Operating Instructions, section 'Terminals', keyword 'large display panel' and keyword 'communication') 4.2.1 Connection information The included supply is connected with correct polarity to terminals 1 and 2. If the power supply cable needs to be lengthened, the wires should have about a 0.75 mm 2 cross section. Please note that the power supply must only be used in dry places! The RS-485 output (COM 2 or 9) of the Sunny Boy Control is connected to terminals 3 and 10. A shielded cable must be used to connect to the Sunny Boy Control. The size of the cable is not important. Data+ of the large display panel is connected to Data+ (COM2/3 pin 3) of the Sunny Boy Control. Data- of the large display panel is connected to Data- (COM2/3 pin 8) of the Sunny Boy Control. The shield is connected only to 0V (terminal 2) of the large display panel and remains open on the Sunny Boy Control side. 10

4.2.2 Connection diagram Large display panel 1 2 9 10 + Power Netzteil supply Schirm Shield Sunny Boy Control COM2/3 Sunny (RS-485) Boy C 1 6 9 5 11

4.3 Connection to a Sunny Boy Control (Light, Standard, Plus) using RS-232 The RS-232 interface is intended to connect a correspondingly equipped Sunny Boy Control using an RS-232 connection for cable lengths up to 15 m max. Important Notice: The Sunny Boy Control must be configured for operation with the large display panel. Settings: Display type HvG, baud rate 2400 (for details, see Sunny Boy Control Operating Instructions, section 'Terminals', keyword 'large display panel' and keyword 'communication') 4.3.1 Connection information The included supply is connected with correct polarity to terminals 1 and 2. If the power supply cable needs to be lengthened, the wires should have about a 0.75 mm 2 cross section. Please note that the power supply must only be used in dry places! The RS-232 output (COM 2 or 3) of the Sunny Boy Control is connected to terminals 3 and 4. A shielded cable must be used to connect to the Sunny Boy Control. The size of the cable is not important. RxD of the large display panel (terminal 3) is connected to TxD (COM2/3 pin 3) of the Sunny Boy Control. GND of the large display panel (terminal 4) is connected to TxD (COM2/3 pin 5) of the Sunny Boy Control. The shield is connected only to 0V (terminal 2) of the large display panel and remains open on the Sunny Boy Control side. 12

4.3.2 Connection diagram Großanzeige Large display panel 1 2 3 4 + Power Netzteil supply Schirm Shield Sunny Boy Control Sunny Boy COM2/3 (RS-232) 1 6 9 max. Max. 15 15 meters Meter 5 4.4 Connection to a SolarWorld Suntrol using RS-485 The RS-485 interface is intended to connect to a SolarWorld Suntrol datalogger using an RS-485 connection for (total) cable lengths up to 1000 m. Important Notice: The baud rate set in the large display panel must agree with the baud rate of the inverter. This must be coordinated with the manufacturer prior to delivery (factory setting: 9600 baud). Operation of the large display panel on the Suntrol with Fronius inverters The inverters must be operated according to the instructions for the STL800 on the RS-422/485-B interface. The large display panel is operated on the RS-485-A interface. The baud rate in the large display panel is set to 9600 baud. 13

4.4.1 Connection information The large display panel is connected to the RS-485 terminal of the Suntrol on terminals 9 and 10, in series with the inverters. A shielded cable must be used to connect to the Suntrol. The size of the cable is not important. Data+ of the large display panel (terminal 9) is connected to RS-485 pin 1 of the Suntrol. Data- of the large display panel (terminal 10) is connected to RS-485 pin 4 of the Suntrol. With the STL800, RS-485 A or B can be used (except Fronius, see above). The shield is connected only to 0V (terminal 2) of the large display panel and remains open on the Suntrol side. 4.4.2 Connection diagram Large display panel Suntrol 1 2 3 Power supply Shield Pin 1 3 1 4 1 6 RS-485 with the inverters 14

5 Configuration of the large display panel After installation and assembly, the large display panel must be configured. The large display panel comes preconfigured from the factory but may need to be adjusted depending on the conditions on site. The following can be set: > Data source (from which the large display panel receives the data to display) If the data source is a current meter with pulsed output: > Starting value for total output (kwh) > Pulse rate (pulses/kwh) The settings are made using the button between terminals 6 and 7. How long the button is pressed determines the result: Duration Result Note Short press < 1 second The value of the number to be changed is increased by 1 The value is increased when the button is released. Long press > 1.5 seconds The number place to be changed is moved one position to the left or the setting is saved Hold the button down until the decimal point moves to the left or to the next setting value 15

5.1 Settings a) Hold the button down while pressing the power supply button: 'CFG' appears in the top field. b) After the button is released, 'SrC' appears in the top field (data source). c) The second field shows the number of the data source now set in the display panel. Now the data source (for the number assignments of the data sources, see list below) can be set: > Short press: The number shown is increased by one. Important: The number changes only once the button is released! Note: After 9, the number goes back to 0. If you accidentally miss the desired number you can get back to it by pressing the button briefly several more times. > Long press: The selected data source is saved. Important: Hold the button down until the display runs a segment test or 'StArt' appears in the top field! The data sources in the second field are numbered as follows: 0: Current meter with pulsed output 1: Sunny Boy Control RS-232 2: Sunny Boy Control RS-485 3: MaxComm Basic RS-485 4: Fronius DisplayCard RS-232 5: RiCo RS-232 6: RiCo RS-485 7: CV 485 8: Power One Aurora inverter RS-485 9: Solutronic inverter RS-232 10: Solar Data Systems SolarLog 800/400 e RS-485 (standard: baud rate 9600) 16

d) Once the desired data source is set, the starting value for the total output (kwh) can be set for data source 'Current meter with pulsed output'. For all other data sources, the configuration is finished at this point. e) If the data source is a current meter with pulsed output, the top field now reads 'Strt'. The starting value can now be set: > Short press: The value of the place is increased by one (beginning with the far right place). Important: The value of the place changes only once the button is released! Note: After 9, the number goes back to 0. If you accidentally miss the desired number you can get back to it by pressing the button briefly several more times. > Long press: The decimal point moves one place to the left.(exception: the far right place--the decimal point does not appear here.) Important: Hold the button down until the decimal point moves to the next place! It must go through all 6 places for the value to be stored. f) Once all of the places in the starting value have been changed as desired, another long press of the button takes you to the pulse rate setting. 'PULSE' appears in the top field. The procedure for setting the pulses/kwh is similar to that for the starting value. It must go through all 5 places for the value to be stored. Another long press of the button saves the settings and the display goes into its normal measuring mode, indicated by performing a segment test. 17

6 Factory settings Terminal: Top display value: Middle display value: Bottom display value: Factor CO 2 savings: Standard: Pulse 1000 I/kWh Current power in watts Total energy in kwh CO 2 savings in kg 0.70 kg/kwh 18

7 Technical data Number of measured values that can be shown 3 Display elements 7-segment LED fields with 45 mm high characters, Color: red Resolution per measured watts, 5 places, up to 99999 max. value kwh, 6 places, up to 999999 max. kg, 6 places, up to 999999 max. Housing dimensions W x H x D: 800 x 600 x 50 mm Housing material Front plate: Single-pane safety glass, 5 mm Housing: aluminum, plastic Operating temperature 0 to + 40 C, with "outdoor" option - 15 to + 50 C Storage and transport - 20 to + 60 C temperature Supported data sources - Pulse generator (floating make-contact) (depending on configuration, data source must be - Suntrol 200/400 and 800 - SMA Sunny Boy Control Standard, Light and Plus indicated with order!) - various other systems on request Inputs, interfaces - Pulse (for floating make-contact, minimum pulse length: 2 ms) - RS-232 - RS-485 Power supply External power supply: Input: 230 V AC, Output: 12 V DC, 1 A Never connect display directly to the 230-V AC grid or voltages greater than 12 V DC: may cause danger, damage or fire! Warranty 2 years Standards CE Subject to change, technical or otherwise 19

SolarWorld AG Martin-Luther-King-Str. 24 53175 Bonn, Germany Phone: +49-228 - 55920-0 Fax: +49-228 - 55920-99 service@solarworld.de www.solarworld.de SolarWorld. And EveryDay is a SunDay. www.solarworld.de