UWPR Advancing Proteomics

Similar documents
TMT data acquisition on the LTQ-Orbitrap XL Mass Spectrometer

STANDARD OPERATING PROCEDURE:

Liquid Chromatography- Mass Spectrometer Manual

GC/LC-MS: data acquisition rate and peak reconstruction

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

Creating and fully utilizing the retention time standard processing method for a more automated IC workflow

Operating Instructions

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

Basic Pattern Recognition with NI Vision

Processing data with Mestrelab Mnova

SIDRA INTERSECTION 8.0 UPDATE HISTORY

Sample Analysis Design. Element2 - Basic Software Concepts (cont d)

Tutorial 3 Normalize step-cycles, average waveform amplitude and the Layout program

Quick Guide Book of Sending and receiving card

MTL Software. Overview

Achieving More Efficient Data Review with OpenLAB CDS

How to Optimize Ad-Detective

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Practicum 3, Fall 2010

D-901 PC SOFTWARE Version 3

Libera Hadron: demonstration at SPS (CERN)

Getting Started with the LabVIEW Sound and Vibration Toolkit

StrataSync. DSAM 24 Hour POP Report

APPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone

DektakXT Profilometer. Standard Operating Procedure

Application Note - TechComplete Test Productivity Pack. POP Reporting

Topic: Instructional David G. Thomas December 23, 2015

Manual for the sound card oscilloscope V1.41 C. Zeitnitz english translation by P. van Gemmeren, K. Grady and C. Zeitnitz

SEM- EDS Instruction Manual

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

Software Operation Manual

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

C8491 C8000 1/17. digital audio modular processing system. 3G/HD/SD-SDI DSP 4/8/16 audio channels. features. block diagram

EDL8 Race Dash Manual Engine Management Systems

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

Quick Start Guide. Multidimensional Imaging

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

The MPC X & MPC Live Bible 1

Dektak Step by Step Instructions:

Introduction to the Thermo Scientific Q Exactive HF-X MS for Proteomics

Linrad On-Screen Controls K1JT

Skycoor Manual PEKASAT SE 2016

Operating Instructions

CMRRpack2. a collection of pulse sequences from the. University of Minnesota, Center for Magnetic Resonance Research (CMRR) Version: 2.

CytoFLEX Flow Cytometer Quick Start Guide

Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V.

Scan Converter Quick Installation Guide

VivoSense. User Manual Galvanic Skin Response (GSR) Analysis Module. VivoSense, Inc. Newport Beach, CA, USA Tel. (858) , Fax.

Import and quantification of a micro titer plate image

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

Instrument Firmware Release Notes

Realizing Waveform Characteristics up to a Digitizer s Full Bandwidth Increasing the effective sampling rate when measuring repetitive signals

The DataView PowerPad III Control Panel

The Measurement Tools and What They Do

Common Spatial Patterns 3 class BCI V Copyright 2012 g.tec medical engineering GmbH

#PS168 - Analysis of Intraventricular Pressure Wave Data (LVP Analysis)

SHENZHEN H&Y TECHNOLOGY CO., LTD

BrainMaster tm System Type 2E Module & BMT Software for Windows tm. Display Screens for Master.exe

GVD-120 Galvano Controller

NanoTrack Cell and Particle Tracking Primer

Select source Click the Bio Settings button to modify device settings. Select Fingers Use Ctrl+Left mouse button to select multiple fingers to scan.

Cedits bim bum bam. OOG series

CA Outbound Dialer Module. Operation Manual v1.1

Standard Operating Procedure of nanoir2-s

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

set. Important Note: the system must be calibrated before meaningful quant results can be obtained!

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

DDA-UG-E Rev E ISSUED: December 1999 ²

Statement SmartLCT User s Manual Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter referred to as NovaStar ). It is our great

Screen Shot User Guide Clinical Agency

MAutoPitch. Presets button. Left arrow button. Right arrow button. Randomize button. Save button. Panic button. Settings button

WV-NP1004. Network Operating Instructions. Network camera. Model No. (Lens is option.)

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

JAMAR TRAX RD Detector Package Power Requirements Installation Setting Up The Unit

Kratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25)

RS232 Connection. Graphic LCD Screen. Power Button. Charger Adapter Input LNB Output. MagicFINDER Digital SatLock Operating Manual

FACSAria I Standard Operation Protocol Basic Operation

Digital Display Monitors

LA xlimit. Manual. by tb-software (C) tb-software 2015 Page 1 of 6

LUMIGEN INSTRUMENT CENTER X-RAY CRYSTALLOGRAPHIC LABORATORY: WAYNE STATE UNIVERSITY

PulseCounter Neutron & Gamma Spectrometry Software Manual

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

Precision testing methods of Event Timer A032-ET

potentiostat/galvanostat

Indiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope

User Manual K.M.E. Dante Module

Grid Interactive Advanced Features Self-Supply Mode

PHI 5000 VersaProbe TM Operator s Guide

980 HDMI 2.0 Video Generator Module. Application Note UHD Alliance Compliance Testing with the UHDA Test Pattern Pack

1.0 ThermoNicolet Nexus 670 FTIR Spectrometer Instructions

Network Camera Operating Manual

Forensic Video Analysis Technical Procedure Manual Page 1

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

TUTORIAL IGBT Loss Calculation in the Thermal Module

System Requirements SA0314 Spectrum analyzer:

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

Logic Controls LV3000 VGA Connected Virtual Pole Display

Transcription:

How to setup a PRM assay on the QExactive Plus (SW v 2.7) Inclusion List First you need a list of peptides representing the proteins you want to monitor/quantify. You can use prior DDA data, databases or theoretical peptides. Generate an inclusion list including: - Mono-isotopic precursor m/z - charge state (z) - For scheduling you ll need the start and end times, - you can also include the peptide sequence in the comment field if you wish You can use skyline to generate the list for you. Follow their tutorials. Note you ll likely use Skyline to analyze your data, so you might as well use it to generate your inclusion list. https://skyline.gs.washington.edu/labkey/wiki/home/software/skyline/page.view?name=tutorial_targeted_msms Instrument method Open the method editor, expand the Global Lists and click on Inclusion List. The Method editor Inclusion List will pop up. You can enter all the values manually or you can export a template to csv and copy/paste your list. To export a template, enter a couple of values (I usually enter the m/z and z in the first row only). Then click on File/Export and give it a path and file name, this will save the template as a csv file. Now open that file in Excel: Page 1

Now copy your inclusion list into this file, save and close it. Note you need to close the csv file in order to import into the method editor. You ll need to enter monoisotopic masses for the peptides of interest and the charge state and polarity. If you want to schedule the monitoring enter a start and end time as well, if left blank the targets will be monitored the entire time of the acquisition. NCE can be set in the list or globally. In the comment field I usually enter the peptide sequence. Go back to Method editor Inclusion List click File/Import (make sure the csv file is closed) Select the csv file and hit ok. You should now see all the values for your inclusion list. Click the green checkmark labeled done to safe the list. Note any of the instrument modules that use the inclusion list will use this list (PRM, DIA, targeted SIM etc.) Instrument paramters Now you need to setup your method parameters: This is a screen shot of a common PRM method we use. Page 2

Make sure the user role (upper right corner, under global settings) is set to Advanced so you see all the parameters you can change. - We ve been using the default tolerances, but you can customize them if you wish. - Resolution: to achieve the fastest scan speed, choose the lowest available resolution. Note you ll need to know the resolution setting you use to acquire the data when you go to import data into skyline. - AGC target: we typically use 2e4-1e5 - Maximum IT (ion time): ms at 17 resolution, you can increase the ion time but it will slow down the instrument. Note in targeted experiments when the targeted precursor is absent, the instrument will fill to the max IT, because there are not enough ions to reach the target value. Only when ions are present will the AGC start regulating the IT. In other words the IT is lower than the max IT only if your target peptide is eluting. Because the instrument is doing the fill while it is acquiring data in the Orbitrap, you have free fill time. So you don t waste time as long as your IT does not exceed the OT scan time. - Isolation width: on the QE we used 2m/z, on the QE plus we use 1.6 m/z, the lower you go the fewer contaminating peptides are co-isolated, but at some point the sensitivity starts to drop. You can try using an offset, to try and get all/more of the isotopes included: Page 3

Full Scan - PRM If you wish to acquire a full scan as well you can include the Full MS SIM Experiment: To include a in between the PRM scans, we tried setting it up like this, but unfortunately it alternates between full scan and a single PRM scan, rather than one full scan followed but all the PRM scans. RT: 37.33-37.39 95 9 85 37.34 PRM 1 PRM2 PRM 3 37.37 37.35 37.37 37.36 37.35 37.36 etc 37.38 37.38 NL: 4.74E9 TIC MS 1411_ 6x5LCMS_ Hela_MS1_ PRM_4 75 65 55 45 35 3 25 15 5 37.335 37.3 37.345 37.3 37.355 37.3 37.365 37.3 37.375 37.3 37.385 That s likely a bug that may get fixed in future SW version. To get around that we use the DIA experiment instead of the PRM (but using the PRM inclusion list) like this: With this setup it will do a full scan, and then go through all the precursors in your list (during the scheduled time). You can also define the loop count, e.g. 5, in that case it will do a full scan followed by the first 5 precursor (1-5) MS/MS defined in your list, then a full scan followed by the next 5 precursors (6-) in the list, etc. (see screen shots below). Note if you set the Maximum IT to auto it will max out at 55 ms, in other words it will never exceed 55 ms, in our tests the scan speed with max IT set to auto was 11 Hz and with fixed IT at ms 11.6 Hz. PRM 1-3 PRM 1-3 PRM 1-3 etc PRM 1-5 PRM 6- PRM 11-15 etc Page 4

RT: 39.23-39.51168 39.2463 95 9 85 75 65 55 45 39.28671 39.32712 39.36752 39.793 39.44834 39.48874 NL: RT: 58.97-59.3 3.37E9 59. TIC MS 1411_ 6x5LCMS_ Hela_MS1_ 59.21 DIA_2 9 59.18 59.23 59.4 59. 59.13 58.97 59.16 59.7 59.24 59.28 59. 59.1 59.5 59.8 59.3 59.14 59.27 NL: 2.9E8 TIC MS 12_M 59.3 SQC1_QEplu s_ms1_dia_i Tms_loop5 _3 35 3 3 25 15 5 39.28256 39.293 39.3339 39.2539 39.37431 39.36337 39.43357 39.47634 39.3159 39.378 39.49671 59. 59.5 59. 59.15 59. 59.25 59.3 39.24 39.26 39.28 39.3 39.32 39.34 39.36 39.38 39. 39.42 39.44 39.46 39.48 39. 3 PRM inclusion masses, Loop count 3 3 PRM inclusion masses, loop count 5 We also tried the Full-ddMS2 Experiment using the inclusion list and not allowing to pick others but that didn t work at all as it only did MS2 if the precursor exceeds a certain threshold. But that didn t really work for our experiments. RT: 3.52-5.36 9 4.83 NL: 4.85E4 m/z= 1266.49-1267.49 MS 1411_6x5L CMS_Hela_Full MS_ddMS2_8 4. 3 3.53 3.9 3.73 3.68 3.77 4.59 4.87 4.35 4.91 4.1 4. 4.38 4.67 4.3 4.45 4.92 3.6 3.8 4. 4.2 4.4 4.6 4.8 5. 5.2 Page 5

How many peptides can be monitored? Max scan speed with 17 resolution is 13 Hz (according to Thermo), so you can monitor up to 13 peptides per second. If the chromatographic peak width is 3 seconds and you want to monitor a peptide about times across the chromatographic elution, your total cycle time should be about 3 seconds (3/). So 13 Hz * 3 seconds = 39 peptides at any given time. Chrom. Peak width [sec] Points across the peak Cycle time [sec] Scan speed (depends on resolution) [Hz] # of peptides 3 / 5 = 6 * 13 = 78 3 / = 3 * 13 = 39 3 / 15 = 2 * 13 = 26 To monitor more peptides you need to schedule them using the start and end times in the inclusion list. The table below contains approximate scan rate for the different resolution settings: Fusion/Lumos Resolution at m/z "Free" injection time [ms] Approx. scan speed [Hz] Transient length [ms] Q Exactive Resolution at m/z "Free" injection time [ms] Approx. scan speed [Hz] 15 22 18/ 32 3 54 15 64 17 13 118 7.5 128 35 1 7 1 246 4 256 2 3 2 2 2 512 1 1.5 64 2 <1 >4 14 <1 24 You can check the scan speed for your particular method, just open the raw file in qual browser and zoom in, if you acquired a full scan just look at the time difference between full scans and calculate the scan speed base on the number of scans you had setup to run (full scan plus number of PRM/DIA scans): Now calculate the time difference between the full scans and calculate the scan speed based on the number of MS2 scans between the full scans. In this example is about 12.8 Hz (our inclusion list has 3 precursor masses plus one full scan). Page 6