Corrigendum Date:17/01/2012

Similar documents
Modular Lube Lubrication Systems System Controls

ROTARY EVAPORATOR BOECO ROTARY EVAPORATOR RVO 400 SD

LABSONIC M The ultrasonic homogenizer for every application. Benefits

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

IKA Analytical line Calorimeters C 2000

Optical Cryostat - Omniplex TM

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

TUC: Universal thermostat

C-28 PLUS C-28 C-22 PLUS C-22 C-17 PLUS C-17 Premium sterilisation

SAFETY AND PEACE OF MIND

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Tender Notification for the procurement of a Scanning Electron Microscope" at IISc (Last Date for submission of tenders: 3 rd October 2018)

Closed Cycle Cryogenic Probe Station

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

easyspiral Dilute The world's fi rst automatic diluter & plater A revolution in serial dilutions!

Ezecal MK3 User Manual

Panel-mounting thermostats, type series EM

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

STERILISATION Simple solutions made to measure

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

The world s fastest Spiral plater. easyspiral N

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

Capacitance Limit Detection nivotester FTC 420/421/422

hm 8000 AS/AS-V SealCut

Panel-mounting Thermostats EM Series

IMPAC Infrared Thermometers

Model KBF 115 Constant climate chambers with large temperature / humidity range

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

3. Fibre Gripper - Includes a simple adaptor to fit 70mm glass slides to the OFDA 4000 for measuring fibre snippets (not shown)

Model KT 53 Cooling incubators with thermoelectric cooling

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

V9A01 Solution Specification V0.1

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

Model KT 115 Cooling incubators with thermoelectric cooling

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

High productivity rapid manufacturing systems DIGITALWAX X. for general applications

CATHODE CURRENT DISTRIBUTION CONTROL DEVICE

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

Thermo Scientific Revco PLUS Ultra-Low Temperature Chest Freezers. Maximizing Critical Sample Protection and Storage

Analogue HD Monitoring Set: 8-Channel Video Recorder + 4 Outdoor Cameras

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Eddy Current Technology. eddyliner. digital

DMP 331i / DMP 333i LMP 331 i

GRUNDFOS ALLDOS DATA BOOKLET DDI DIGITAL DOSING

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Bartels Micropumps. ( ) Rev. 2.8

Multicolor Scan Laser Photocoagulator MC-500 Vixi

R3267/3273 Spectrum Analyzers

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

515 PIPEMASTER. Features. Options PROGRAMMABLE POWER SOURCE FOR ORBITAL WELD HEADS

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Electric Rotary Modules. Rotary Actuators

1. General Specification

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Transmitter optics with 9x white light LED (optics cover made of glass)

Model KBF P 240 Humidity test chambers with ICH-compliant light source

PTC Series. Professional Temperature Calibrator PTC-155/350/425/660

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Forced Convection Laboratory Ovens

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DTV/MPEG2 Test & Measurement DTV Signal Generator DSG500

Liquid Level Sensor Type AKS 4100U

FogScreen emotion Projection Screen. User Manual Part 1: Installation Guidelines

Unlocking of building entrance door shall be possible by pressing the monitor's door-opener button.

Bimetal Temperature Switch

Model KBF 720 Constant climate chambers with large temperature / humidity range

Cooling systems for ORBIMAT

Zortrax Inkspire. Instrument of Precision RESIN UV LCD 3D PRINTER

Electrical connection

Panel-Mounted Thermostat

DVI KVM Switches DVIMUX 7.2

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

FLAT DISPLAY TECHNOLOGY

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

FPM Series. Industrial Flat Panel Touch-Screen Monitors

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RTBUS-12 Round Table Connection Bus. P/N: Rev 1

Agilent E5100A Network Analyzer

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Altman Lighting AP-150 RGBW Par Specification

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

WQ Series Water Quality Bench top Meters

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

2291 Guided Wave Radar Level Transmitter

SPECTRO Series SPECTRO /0 -MSM-ANA-VIS. Design. SPECTRO-3 Series True Color Sensors. Accessories: (p. 8-9) Product name:

Sigma 4-16S Sigma 4-16KS Sigma 4-16KHS

Micro-DCI 53ML5100 Manual Loader

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

Liquid Level Sensor Type AKS 4100/4100U

Request for Proposals

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

Transcription:

Corrigendum Date:17/01/2012 Ref: Tender No: HLL/PCD/ESIC-84/11-12 dated 17/12/2011 Pre-bid meeting held at HLL Lifecare Ltd., Noida on 05/01/2012 at 1100 Hrs. on this Tender. The following corrections/clarifications are issued after pre-bid meeting. Section - I NOTICE INVITING TENDERS (NIT) Under Para-1 for items at sl. no. 36, 58, 66 & 97. Existing: Sl. # Item Description Department Qty EMD Amount (Rs.) 36 Phacoemulsifiermachine Ophthalmology 2 44,000 58 Automated 5 part differential Haematologyanalyser With Reticulocyte count Pathology 1 56,000 66 Autoclave electric Pathology 4 40,000 97 Blood Gas Analyzer (Electrolyte Analyzer) Biochemistry(2) Medicine(2), Cas(1), ICU(1), ICCU(1) 7 112,000 Sl. # Item Description Department Qty EMD Amount (Rs.) 36 Item Deleted - - - 58 Automated 5 part differential Haematologyanalyser Pathology 1 56,000 66 Autoclave electric Pathology 2 20,000 97 Item Deleted - - - HLL/PCD/ESIC-84/Corr-1/11-12 Page 1 of 8 17.01.2012

Section - VI: Under Part-I for items at sl. no. 36, 58, 66 &97 Existing: Sl. # Item Description Department Qty 36 Phacoemulsifiermachine Ophthalmology 2 58 Automated 5 part differential Haematologyanalyser With Reticulocyte count Pathology 1 66 Autoclave electric Pathology 4 97 Blood Gas Analyzer (Electrolyte Analyzer) Sl. # Biochemistry(2) Medicine(2), Cas(1) ICU(1), ICCU(1) Item Description Department Qty 36 Item Deleted - - 58 Automated 5 part differential Haematologyanalyser 7 Pathology 1 66 Autoclave electric Pathology 2 97 Item Deleted - - Section-VII (Technical Specifications) Item Sl. No. 31 A/B SCAN (OPHTHALMIC ULTRASOUND) Complete IOL program capabilities include SRK1 SRK11 SRK. T Hollady or Binkhorest formulas. Complete IOL program capabilities include SRK-II, SRK-T, Hollady or Binkhorst formulae. 10mhz solid probe Deleted User definable, DGC curve User definable, TGC curve HLL/PCD/ESIC-84/Corr-1/11-12 Page 2 of 8 17.01.2012

Standard accessories Should include : Console with 7 display Alphanumeric keyboard Trackball Foot pedal 10 MHz probe for A 10/ 12.5 MHz and 35 MHz probes for B Sacn A scan calibration cylinder Probe holders etc. Vendors may quote other accessories Standard accessories should include: Console with 7 display Alphanumeric key board Trackball Foot pedal Standard accessories should include: Console with 7 display Alphanumeric keyboard Trackball Foot pedal 10-12 MHz probe for A Scan. 10-12.5 MHz probe for B Sacn. A scan calibration cylinder Probe holders etc. Item Sl. No. 34 Operating Microscope with TV Unit & Camera Eyepices: 10X with +8D to -5 D compensator. Eyepices: 10X with diopter compensator -5 D to +5 D. Ethernet interface for microscope i incl. 10 m cable Deleted Item Sl. No. 35 Automated Visual Field Analyzer with printer (Perimeter) Clinically validated normative database (FDA approved). Clinically validated normative database (US FDA/ CE approved). HLL/PCD/ESIC-84/Corr-1/11-12 Page 3 of 8 17.01.2012

Floppy drive, internal hard disk drive with future upgradation to MOD CD/ DVD writer with internal hard disk drive Maximum temporal range 90Deg Maximum temporal range 80-90Deg Central field test patterns 30-2,24-2,10-2,Macula Central and full field testing and Macula testing. Thresold test strtegies full thresold,fast Pac,SITA,SITA Fast,SITA Standard Thresold test strtegies full thresold, Fast Pac, SITA or equivalent. Touch screen on CRT as well as Keyboard & Mouse TFT/ LCD/ LED Monitor as well as keyboard & Mouse Item Sl. No. 40 Non Contact Tonometer Working distance: 13-15mm Equipment should have suitable/ standard working distance Measurement range IOP- 5 to 80 mmhg Measurement range IOP: 7 to 60mm of Hg Accuracy: +/-1mm Hg Accuracy/ Least count: +/-1mm of Hg Electrical requirements: 90 264V AC, 50 Hz Electrical requirements: 100/240 AC, 50 Hz HLL/PCD/ESIC-84/Corr-1/11-12 Page 4 of 8 17.01.2012

Hand set dimentions: 40X 270mm Deleted Base unit dimensions: 320X310X180mm Deleted Weight: 8.5 Kg. (Approx) Deleted Standard: Table top, joystick assembly with chin rest arrangement Standard: Joystick or touch screen control with chin rest or forehead arrangement. Item Sl. No. 55 Donor Chairs 3.5 Comfortable working level for the operator. Lifting capacity - Approx 200 kg. 3.5 Comfortable working level for the operator. Lifting capacity - Approx 150 kg. Item Sl. No. 58 Existing Nomenclature: Automated 5 part differential HaematologyanalyserWith Reticulocyte count Amended Nomenclature: Automated 5 part differential Haematologyanalyser Item Sl. No. 61 Incubator Temperature range, ambient + 50 deg C to 80 deg C +10 deg C Temperature range, ambient +50deg C to 80deg C +/-10deg C HLL/PCD/ESIC-84/Corr-1/11-12 Page 5 of 8 17.01.2012

Item Sl. No. 62 Refrigerated Centrifuge Temp. range: 9 deg C to +40 degree C. Temp. range: -9 deg C to +40 degree C. Item Sl. No. 65 Automatic Cell Counter- 3 Part Should have power back up system in case of power failure. UPS as back up system in case of power failure. Item Sl. No. 66 Autoclave 3.3 Outer and inner chamber made of thick stainless steel 3.3 Outer and inner chamber made of thick stainless steel (SS-316 quality) 3.4 Inner chamber made of at least 18 SWG SS sheet 3.4 Inner chamber made of at least 18 SWG SS sheet (SS-304 quality) 3.5 Inner chamber size 550-650X350-450X350-450mm 3.5 Suitable size of Vertical model with capacity of 125 Litre or more. Item Sl. No. 67 Fully Automatic Heamatology Analyzer- Three Part WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, LYM%, MXD%, GRAN%, LYM#, MXD#, GRAN#, RDW CV, RDW SD, PDW, MPV, PCT and Histogram for RBC, WBC, and PLT WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, LYM%, MONO%, GRAN%, LYM#, MONO#, GRAN#, RDW CV, RDW SD, PDW, MPV, PCT and Histogram for RBC, WBC and PLT HLL/PCD/ESIC-84/Corr-1/11-12 Page 6 of 8 17.01.2012

SFT method for Hemoglobin SFT/ Non-Cyanide method for Hemoglobin. Large color display: resolution 800X600 Large color display: resolution 640 X 480 or more It should have the facility for data storage min 30,000 samples with histogram. It should have the facility for data storage min 1000 samples with histogram. Comprehensive QC program: L-J, X, XR and XB analysis. Comprehensive QC program: L-J, XB analysis. Unique calibration program with fresh blood. Calibration to be done with manufacturer s calibrator only. Item Sl. No. 88 Vertical Jacketed Autoclave 3.5 Inner chamber size - 650 x 450 x450mm 3.5 Suitable size of Vertical model with capacity of 125 Litre or more. Item Sl. No. 90 Flash Autoclave 6. The sterilizer shall have a keypad, which controls the pre-set programs and the start control with a single touch 6:1 Unwrapped Cycle. To sterilize unwrapped instruments the sterilizing cycle shall be constant at 136 degrees C for 3.5 minutes. The total cycle time including warm up,pressurization and depressurisation shall not be more than be 11 minutes. 6.2 Wrapped Cycle To sterilize wrapped instruments the sterilizing cycle shall be constant at 136 degrees C for 6 minutes. The total cycle time including warm up, pressurization and de-pressurisation shall not be more than 15 minutes. HLL/PCD/ESIC-84/Corr-1/11-12 Page 7 of 8 17.01.2012

6. The sterilizer shall have a keypad, which controls the pre-set programs and the start control with a single touch 6.1 Unwrapped Cycle. To sterilize unwrapped instruments the sterilizing cycle shall be constant at 132 0 C or more for 3.5 minutes. The total cycle time including warm up,pressurization and depressurisation shall not be more than be 11 minutes. 6.2 Wrapped Cycle To sterilize wrapped instruments the sterilizing cycle shall be constant at 132 0 C or more for 6 minutes. The total cycle time including warm up, pressurization and de-pressurisation shall not be more than 15 minutes. Item Sl. No. 91 Autoclave 3.3 Outer and inner chamber made of thick stainless steel 3.3 Outer and inner chamber made of thick stainless steel (SS-316 quality) 3.4 Inner chamber made of at least 18 SWG SS sheet 3.4 Inner chamber made of at least 18 SWG SS sheet (SS-304 quality) 3.5 Inner chamber size 550-650X350-450X350-450mm 3.5 Suitable size of Vertical model of capacity 125 Ltr or more. Item Sl. No. 93 FULLY AUTOMATIC BIO-CHEMISTRY ANALYZER RANDOM ACCESS Tests to be analyzed by pre-analyzer, LFT, liquids, total protein, calcium, phosphorus, magnesium amylase, sodium, potassium, bicarbonate, chloride urea, creatine and glucose etc. Tests to be analyzed by LFT, liquids, total protein, calcium, phosphorus, magnesium amylase, sodium, potassium, bicarbonate, chloride urea, creatine and glucose etc. --END-- HLL/PCD/ESIC-84/Corr-1/11-12 Page 8 of 8 17.01.2012