Gallios. Flow Cytometry. Powerful Versatile Performance

Similar documents
More results with advanced optics and superior electronics. Gallios Flow Cytometer

CyFlow Space Your flexible flow cytometer

CytoFLEX Flow Cytometer Quick Start Guide

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

Flow Cytometry. ZE5 Cell Analyzer. Superior performance and flexibility to align with your flow cytometry needs.

FAST MOBILITY PARTICLE SIZER SPECTROMETER MODEL 3091

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Instructions for Use. CytoFLEX. Flow Cytometer. B49006AE November Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA U.S.A.

OPTICAL POWER METER WITH SMART DETECTOR HEAD

CFlow User Guide. Science is hard. Flow cytometry should be easy.

Guide to the FACS Calibur

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Connection for filtered air

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

HD Network Video Recorder Workstation

In-process inspection: Inspector technology and concept

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

Standard Operating Procedure Of The CytoFLEX S Flow Cytometer At The Institute Of Virology

LSR II Users Guide Stanford Shared FACS Facility

Prisma Optical Networks Ancillary Modules

NOTES ON FACSCalibur USE AND TROUBLESHOOTING PROCEDURES. Department of Immunology Monash University 14/12/07

Analysis and sorting of cells with FACSAria II flow cytometer Tiina Pessa-Morikawa / Revised

BD FACSAria III User s Guide

MAP Optical Power Meter Module (mopm-b1)

M4000 Diagnostic Test System For Power Apparatus Condition Assessment

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

USB Smart Power Sensor

FACSAria I Standard Operation Protocol Basic Operation

MTS/T-BERD Platforms WDMPMD Module

CARESTREAM DIRECTVIEW Elite CR System

ABB MEASUREMENT & ANALYTICS. MB3000 The most reliable FT-IR laboratory analyzer

CARESTREAM DIRECTVIEW Elite CR System

Ultimate quality control. No compromise. PROCESS / QUALITY CONTROL

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

ABB MEASUREMENT & ANALYTICS. MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

DPD80 Infrared Datasheet

SPATIAL LIGHT MODULATORS

OTS-300 Express Series Power Meters/Sources and Testers

icon H600: Network centric visualization

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

Model 4700 Photodiode Characterizer

Advanced Test Equipment Rentals ATEC (2832)

DVO700 P FIBRE OPTIC TRANSMITTER

NEXT/RADIUS Shelf Mount CCU

JD725A Cable and Antenna Analyzer - Dual Port

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

Product Guide. WaveAnalyzer High-Resolution Optical Spectral Analysis

Advanced Test Equipment Rentals ATEC (2832)

specification display applications cronus spectrometer & colorimeter

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

Opti Max Nodes Digital Return System

25W 9xxnm Uncooled Multimode Laser Diode Module

T-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

DPD80 Visible Datasheet

Optical Component Environmental Test System

Silicon PhotoMultiplier Kits

ITS-I. Test station for evaluation of image quality of image intensifier tubes. Fig. 1. Photo of the ITS-I test station: a)photo, b)block diagram

OSICS 8-Channel Modular Platform for DWDM Testing

Microwave Counter, Power Meter and DVM in One Portable Package

Digital SWIR Scanning Laser Doppler Vibrometer

MTS/T-BERD 8000 Platform

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

WATCHMASTER IP THERMAL SURVEILLANCE SYSTEMS

CBF500 High resolution Streak camera

innovative technology to keep you a step ahead 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

Checking the fluids of the cart

Compact live fiber identifier with integrated optical power meter

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Analog Dual-Standard Waveform Monitor

Datasheet. Shielded airmax Radio with Isolation Antenna. Model: IS-M5. Interchangeable Isolation Antenna Horn. All-Metal, Shielded Radio Base

Multicolor Scan Laser Photocoagulator MC-500 Vixi

Intelligent Monitoring Software IMZ-RS300. Series IMZ-RS301 IMZ-RS304 IMZ-RS309 IMZ-RS316 IMZ-RS332 IMZ-RS300C

DB-VRC4H 4K HDMI Compact Video Wall Controller with 45 degree screen rotation

InSight Pro. Valuable real-time process insight

CyAn User Manual. Flow & Mass Cytometry Center Biomedical Core facility. Technion Faculty of Medicine

Switching Solutions for Multi-Channel High Speed Serial Port Testing

Compact EGC Fiber Deep Nodes A90100 and A90300

Photonics solutions For innovative photonics

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

Long Distance L-Band Fiber Optic Links

2x2 HDMI Matrix Switch - 4K with Fast Switching and Auto-Sensing

Advanced Test Equipment Rentals ATEC (2832)

DS2460Q QAM Analysis Meter

Industrial Diode Laser (IDL) System IDL Series

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

Datasheet. 5 GHz airmax AC AP. Models: LAP-120, LAP-GPS. High-Performance Sector AP. Up To 450+ Mbps Real TCP/IP Throughput

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

MTP1000 with LaserBlade, VOABlade, PowerBlade & SwitchBlade Smarter Modular Test Platform

Transcription:

Gallios Flow Cytometry Powerful Versatile Performance

Gallios Flow Cytometer Powerful Versatile Performance Designed with your research needs in mind, the Gallios Flow Cytometer provides very efficient acquisition of high-quality data. Using up to 10 colors and an advanced optical design, you get enhanced sensitivity when analyzing multi-color assays. The Gallios Flow Cytometer s optimized electronics ensure you will have the highest resolution in the shortest amount of time, with the most accurate processing of your flow cytometry data.

State-Of-The Art Optics The Gallios Flow Cytometer is in a class by itself with its advanced optical design that provides efficient acquisition of superior quality data. The Gallios is built with two highly stable, solidstate lasers in standard red and blue. You can choose the option to add up to four lasers by opting for violet and yellow lasers. Easily interchangeable optical filters facilitate detection of a variety of dyes and wavelengths. An innovative forward-scatter detector enables superior resolution of submicron particles down to 0.404 µm in diameter. A side-scatter detector incorporates an independently focused, high-performance photodiode with electronic attenuation. Six fluorescence detectors provide simultaneous acquisition of up to six fluorescence signals. Flexibility to Expand Your Research By incorporating the optional 405nm violet laser and an optional 561nm yellow laser, the Gallios Flow Cytometer offers a greater choice of fluorochromes to perform sophisticated multicolor experiments. You can upgrade your Gallios Flow Cytometer by adding up to four additional fluorescence detectors, which, in turn, enables the concurrent reading of up to 10 colors. The Gallios is available in 2, 3 and 4 laser configurations: 6 color, 2 laser (488nm Blue & 638nm Red) (5 + 1) 8 color, 2 laser (488nm Blue & 638nm Red) (5 + 3) 10 color, 3 laser (488nm Blue, 638nm Red & 405nm Violet) (5 + 3 + 2) 10 color, 4 laser (488nm Blue & 561nm Yellow [co-linear], 638nm Red, 405nm Violet) (5 + 3 + 2) The optional 561nm yellow laser is co-linear with the blue 488nm laser

Fluorescent protein detection with 488 and 561 nm excitation. Escherichia coli transfected with mcherry, dsred, mkate and dtomato could be resolved in FL1, FL2, and FL3 (panels A-D). Mouse spleen cells transfected with FoxP3-mRFP (blue) are shown in panel E. Easily Detect Fluorescent Proteins with Optional 561nm Laser Take full advantage with the optional 561nm laser. The Gallios Flow Cytometer is now equipped for an optional 561nm laser to allow for expanded applications and greater choice of fluorochromes for multicolor experiments. With the new 561nm laser system you can analyze multiple fluorescent proteins simultaneously, as well as benefit from a greater ability to detect red fluorescent proteins. Superior Resolution The Gallios Flow Cytometer was engineered to meet the extreme challenges of an increasingly complex analytical environment in the laboratory. Built on a platform designed with reliability and stability in mind, the Gallios samples information at 4.0MHz and displays data on a 1,048,576 channel scale. These specifications offer superior resolution of cell/particle characterization without sacrificing any of the analytical speed or integrity of the data. Analyze red fluorescent proteins such as mcherry and DsRed. Take full advantage of improved PE tandem dyes for enhanced detection. Versatile for both phenotypic and functional analysis using fluorescent antibodies, dyes and proteins. Minimal or no compensation is needed as FITC and PE are detected using the 488nm blue laser and the 561nm yellow laser, respectively. The electronics provide accurate and efficient signal processing at high event rates. A selection of up to 62 parameters can be processed per analysis at acquisition rates of 25,000 events per seconds with high yield. The compact flow cytometer delivers a stable performance over long periods of time and across a wide range of operating temperatures. So whether your challenges are dim markers, rare events, or just routine analysis, the Gallios is the cytometer of choice to capture all of your events; collecting four times the information as the cell passes through the interrogation point and displaying the information on a scale with four times the resolution.

Kaluza s innovative multiparametric plots revolutionize the way data is analyzed. Multidimensional visualization tools can significantly reduce time required for complex data analysis. Elevate Your Data Analysis With Kaluza PROService Remote Diagnostics Today, more colors require more plots, events, protocol complexity and ultimately increased analysis time. Kaluza Analysis Software is the perfect complement to the Gallios system. It s designed to efficiently and quickly analyze multi-color, multiparametric data, providing real-time updating of display and statistics. Its revolutionary speed (analyzing millions of cells, not thousands) makes analysis of multiple data sets as simple as drag and drop. Not only do we care about designing and manufacturing quality instrumentation, but we also want to ensure that your Gallios Flow Cytometer is operating at its peak performance. To that end, we created PROService, a remote diagnostic system that enhances the technical support of your flow cytometer. We can more efficiently troubleshoot and resolve any issues competently, proficiently and promptly so that your flow cytometer will have minimum downtime. In certain circumstances, our PROService may even be able to preemptively identify potential problems and may even be able to correct them before they impact your laboratory productivity. You can count on Beckman Coulter to provide you with 24-7 support from our expert field consultants. The Kaluza Flow Cytometry Analysis software package features new tools that simplify the management of multiple data sets, allows visualization of high-content data in different spatial dimensions on a single plot and provides real-time analysis of highcontent flow cytometry files. The interface includes automatic plot organization, a zoom in/out feature to enhance data exploration and auto-layout, which reconfigures the workspace in order to reduce the process of maintaining an analysis. The software works with the majority of FCS-compliant files, can operate on either network or stand-alone computers and is supercomputer compatible with the NVIDIA Tesla graphics card.

Gallios Specifications & Performance Characteristics OPTICS Lasers LASER/POWER OUTPUT Blue Solid State Diode: 488nm, 22mW laser output Red Solid State Diode: 638nm, 25mW laser output Violet Solid State Diode: 405nm, 40mW laser output* Yellow Solid State Diode: 561nm, 21.5mW laser output* CONFIGURATION 125µm spatially separated beam spots MINIMUM LASER POWER AT FLOW CELL Blue: >20mW Red: >20mW Violet: >30mW** Yellow: >17mW** Flow Cell 150 x 460µm micron rectangular quartz Collection Optics Gel coupled 1.2 NA lens Optical Filters Easy interchangeable optical filters Optimal 18-degree reflective optics for minimal light loss Detector Filters Standard Configuration Forward Scatter: 488/10 Blue Laser: 525/40, 575/30, 620/30, 675/20**, 695/30, 755LP Dyes: FITC, PE, ECD, PC5 or PC5.5, PE-Cy7 Red Laser: 660/20, 725/20*, 755LP* Dyes: APC or Alexa Fluor 647, APC-Alexa Fluor 700, APC-Cy7, APC-Alexa Fluor 750 Violet Laser:* 450/40, 550/40 525/40** Dyes: Pacific Blue, Pacific Orange, Krome Orange Detector Filters Optional 561nm Configuration Forward Scatter: 488/10 Blue Laser: 525/40, 575/30, 620/30, 675/20**, 695/30, 755LP Dyes: FITC, PE, ECD, PC5 or PC5.5, PE-Cy7 Co-linear Yellow Laser:* 525/40, 582/15, 620/30, 695/30, 755LP Dyes: DsRed, mcherry, mstrawberry, mbanana, morange, mplum, mraspberry, mtangerine, RFP, PE-Cy5, PE-Cy5.5, Alexa Fluor 546, Alexa Fluor 568, Alexa Fluor 594, Alexa Fluor 610 Red Laser: 660/20, 725/20*, 755LP* Dyes: APC or Alexa Fluor 647, APC-Alexa Fluor 700, APC-Cy7, APC-Alexa Fluor 750 Violet Laser:* 450/40, 550/40 525/40** Dyes: Pacific Blue, Pacific Orange, Krome Orange SAMPLE PROCESSING Flow Rates Continuous pressure is applied to the sample tube based on user selected flow rates: Low, Medium and High Sheath Consumption Acquisition: 780mL/hour Carryover: < 0.1% Compatibility: 12 x 75mm tubes Sheath stream stops automatically after acquiring sample Acquisition Modes 32 tube Multi Carousel Loader (MCL) Single tube sampling mode Automated work list acquisition Manual work list mode Mixing The MCL patented design vortexes each tube individually before sample acquisition Biosafety Biohazard contained wash station thoroughly rinses sample probe Fluidics 10L IsoFlow External Sheath Container 20L Waste Container 1.5L FlowClean Cleaning Fluid Tank 1.5L Internal Sheath Tank SIGNAL PROCESSING Flow Rates Dynamic Range: 20-bit data acquisition Workstation Resolution: 1,048,576 channels Digital Sampling Rate: 40MHz Digital Accuracy: < 5% error Parameters: Five different signals available from each detector: Integral linear and logarithmic, Peak linear and logarithmic and True Time of Flight linear Time, Ratio Selection of up to 62 parameters PERFORMANCE CHARACTERISTICS Throughput Throughput of 10k normal lymphocytes is 80 tubes/hour Up to 88 tubes an hour at 10,000 events per second Detectors FORWARD SCATTER DETECTOR Fourier design providing up to 3 measurements of forward angle SIDE SCATTER DETECTOR Independently focused high performance photodiode with electronic attenuation FLUORESCENCE DETECTORS FL1-FL10 Fluorescent Detectors (7-10 optional*)

Scatter Resolution Resolves 0.404µm diameter particles from background noise using forward scatter, with maximum detection up to 40µm diameter particles File Format FCS 3.0 compatible Storage of both compensated and un-compensated data Storage of embedded protocol for rapid replay REMOTE DIAGNOSTICS PROService PROService compatible; high-speed Internet connectivity with optional hardware for remote system monitoring, diagnostics and repair Fluorescence Sensitivity Threshold Levels FITC 112 MESF PE 78 MESF PE-Cy5 15 MESF APC 75 MESF Acquisition Rate Greater than 90% yield at 25,000 events per second GALLIOS SOFTWARE Acquisition Unlimited histogram displays per sample 256 regions are available per protocol with up to 32 available Boolean gates Autogating and Flex quadrant with dual parameter histograms Settings & Compensation Manual or automatic voltage adjustment (using Flow-Set Pro Fluorospheres) Manual or automatic color compensation settings Real time and listmode of inter and intra beam compensation Offline compensation matrix generation Customizable display of six positive decades and negative scale WORKSTATION (MINIMUM SPECIFICATIONS) Operating System: Windows Business Vista, 32 bit RAM: 4GB Processor Frequency: Pentium Core 2 Duo 2.13GHz Hard Drive: 160GB Removable Media Support: DVD 18X, CD 40X Network Ports: 3, 2 available for networking Video Card: PCI express x 16, 256MB DDR2 54-bit onboard memory Support for 1689 x 1050 resolution dual monitors USB Ports: 8 RoHS Compliant Monitor: 22-inch Flat Panel LCD Monitor INSTALLATION REQUIREMENTS Power: Universal Power Supply (100-240VAC, 50-60Hz) Operating Temperature: 15.5-32 C (60-90 F) Noise: < 60db PHYSICAL DIMENIONS Cytometer Supply Cart 561nm Laser System Weight 104kg 230lbs Weight 30kg 67lbs Weight 4.08kg 9lbs Width 95cm 38in Width 72.4cm 28.5in Width 33.02cm 13in Height 61cm 24in Height 29.8cm 11.75in Height 8.61cm 3.38in Depth 70cm 28in Depth 49.5cm 19.5in Depth 23.11cm 9.01in ORDERING INFORMATION Data & User Management Administrator control of password security and user access privileges Fully compatible with Microsoft Office including automated Excel export functionality Customizable FlowPage for reporting with automated pdf or printer output Database for storing results and connectivity with LIS and middleware Part Number/Description GALLIOS A94291 6 Colors, 2 Lasers (488nm Blue & 638nm Red) (5 + 1 configuration) A94299 8 Colors, 2 Lasers (488nm & 638nm Red) (5 + 3 configuration) A94303 10 Colors, 3 Lasers (488nm Blue, 638nm Red & 405nm Violet) (5 + 3 + 2 configuration) B01751 Optional Gallios 561nm DPSS Yellow Laser System KALUZA ANALYSIS SOFTWARE (Optional) EDUCATIONAL LICENSES (For Degree Granting Institutions) B16406 SWRE Kit Kaluza, Single User Educational License B16407 SWRE Kit Kaluza, 1 Year Single User Educational License B16408 SWRE Kit Kaluza, 5 User Network Educational License B16409 SWRE Kit Kaluza, 10 User Network Educational License STANDARD LICENSES A82959 SWRE Kit Kaluza, Single User License, Perpetual A82960 SWRE Kit Kaluza, 5 User Bundle License A82961 SWRE Kit Kaluza, 10 User Network License A84174 SWRE Kit Kaluza, 1 Year Single User, Renewable A84175 SWRE Kit Kaluza, 5 User Network License A85788 SWRE Kit Kaluza, 3 User Bundle License

Gallios Flow Cytometer Download a free 30-day trial version of Kaluza Analysis Software at www.kaluzanow.com For more information about the Gallios Flow Cytometer, contact your local Beckman Coulter office or log onto our website at: www.gallios561.com Gallios and Kaluza are for research use only. Not for use in diagnostics procedures. * Optionally available depending on upgraded system configuration. ** Optional filter included. These characteristics can be influenced by a number of factors relating to instrument setup, sample type, number of parameters selected, protocol definition and number of events acquired. Refer to Instrument Instructions for Use for more information on Analytical Characteristics. Gallios, Kaluza, Krome Orange, Beckman Coulter and the stylized logo are trademarks of Beckman Coulter, Inc. and are registered with the USPTO. NVIDIA is a registered trademark of NVIDIA Corporation. Pacific Blue, Pacific Orange and Alexa Fluor are registered trademarks of Molecular Probes, Inc. Pentium Core is a trademark of the Intel Corporation. BR-17146A B2012-13368 2012 Beckman Coulter, Inc.