VITALink Taped Splice Straight Through Crimp

Similar documents
Instructions. Cable with Armor F CAUTION. October Rev A

MOTOR LEAD TO DOWN HOLE CABLE SPLICE PROCEDURE

2178-L/S Series Fiber Optic Splice Case with Gasket

3M Cold Shrink Splice Kit QS-III 5514A

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

3M Cold Shrink Splice Kit QS-III 5416A

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

3M Cold Shrink Splice Kit QS-III 5515A

Fiberglass - Technical Data

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

INSTALLATION INSTRUCTIONS

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

Cold Shrink Silicone Rubber Termination QT-II

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Optical Distribution Box 300 Installation Guide. Version : R0.0

Water blocking tape. Locator ridge HPA-0486

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

LEGEND POWER SYSTEMS

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

3M Distribution Box (DDB)

Industrial Loadbreak Elbow

Quick Term II Silicone Rubber Termination Kits for Shielded Cables Instruction Sheet

HDBT Installation Guide

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

SBN Pendant Pushbutton Station. Instruction Manual. Part Number: R1 January 2016 Copyright 2016 Magnetek Material Handling

IndyGo Facility Upgrades Project 35671EE

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

Multi-Media Installation Guide

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

3M Cold Shrink Foldback Splice Jacket Kit

3M Fiber Optic Wall Mount Enclosure 8430 Series

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

3 SLiC Aerial Closure with Rubber End Seal

3M Better Buried Compound Compression Closure System

Student Services & Classroom Addition

3M Better Buried Closures

3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0

Telecommunications Service Technician

FusionLink Central Tube Ribbon Preparation & handling procedure

Medium Box for Cable Termination

VITALink MC. 2 Hour Fire Rated Cable UL FHIT 120/ULC S139 FHIT Installation Manual

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

Cold Shrink Straight Joint

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

Public Works Division Lighting District Fiber Optic Specifications April 2009

18mm ECAM Cable Entry Port

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

3M Cold Shrink Rubber Splicing Kit 5552

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

TITLE: FIBER OPTIC SHOCK FIXTURES

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

HCS - HES Cabling Systems

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

Cambria County Association for the Blind and Handicapped 175 Industrial Park Road Ebensburg, PA Prepared for: Prepared by:

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Instruction manual. Midi Fiber Dome. Instruction manual

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

Fiber Optic Splice Closure GPJ Instruction Manual

System 500. Non-fire-rated, mineral insulated copper sheathed wiring cable

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

Table 4-1: Rating Levels

Instrukcja montażu. FLEX LED Neon Instalacja

SMA One Piece Semi-Rigid Connectors

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

Panduit Recommended Best Case Practice Split Fibre

SPECIFICATION. Spec No : VSS-1402-CS603B

OCT 15 Rev B

IP-LINX. Installation Guide

DEM 9ULNACK 3.4 GHz. PHEMT LNA amplifier complete kit assembly guide

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Replacing the PanelMate epro PS, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-12 Series Backlight Assembly

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING

ConnectAnywhere Prep Kit OEM INSTALLATION MANUAL

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

Power Injector 1520 Series

IP-LINX Fiber :: X-XXXX

SECTION 7 -- CROSS-CONNECT SYSTEMS

Cable installation guidelines

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

Transcription:

A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Straight Through Crimp 2 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink Taped Splice Kit contains components and instructions for assembling a 2 hour fire-rated splice on VITALink MC Cable. Read instructions completely before starting. For technical support, call RSCC Wire & Cable LLC at 800-327-7625. Tools Required Utility knife Cable cutter Channel Locks Pipe cutter Crimping tool (comply with UL listing) Needle Nose Pliers Materials Provided (RSCC part number VX99000-001) 2 Rolls of item A below: Self-sealing silicone rubber electrical tape 1 Roll of item B below: Fiberglass tape Breather/drain A B Picture does not represent all tape splice configurations. Additional Materials Required Adalet stainless steel NEMA 4X enclosure with silicone gasket (Series TRN4X-S) Stainless steel breather/drain American Connector stainless steel MC connector Type WT-WSE (See Figure 1) Thomas&Betts tin plated copper compression two-way splice connector standard barrel (See Figure 1) Materials not supplied Figure 1 Two-way splice Stainless steel connector WARNING: IMPORTANT: Installation Guidelines The VITALink MC Splice Kit system must be installed by qualified personnel familiar with generally accepted construction techniques and safe electrical practices. Take all appropriate precautions when installing splices, including following OSHA and other applicable regulations. To ensure this kit is installed correctly, read and follow all the safety warnings and instructions contained in this document. Only stainless steel enclosures and stainless steel MC connectors may be used. The installation must comply with all national and local electrical codes and all the requirements of the UL Electrical Circuit Integrity System listing (UL Category FHIT, System #120) requirements, and carefully follow the installation instructions. Ensure the cable is in good condition prior to commencing splice installation. Do not pull cables around corners that have sharp edges, such as corners in cable trays, or other obstructions. Support the cable in the manner and at the intervals described in the Electrical Circuit Integrity System listing.

2 General A stainless steel enclosure must be used. The enclosure shall be sized in accordance with the National Electric Code (NEC) but in no case smaller than Table 1 below. For reference, Table 2, in the last page of the installation guide, shows a more detailed list of available boxes that may be used to follow Table 1 rules. Cutouts should be positioned to allow splices to hang without touching the bottom of the box. Support the cable within 12 inches from box and every four feet on center thereafter. RSCC s Firewall LSZH bonding wire shall be used inside the box (Not Shown). Do not introduce any materials into splice box that are not described within this installation guide. Table 1 Minimum Enclosure Size The enclosure depth is 4 inches. minimum The minimum enclosure width shall be 8X the NPT of the MC connector. The minimum enclosure height shall be 6X the NPT of the MC connector. MC Connector Installation 1 2 The MC Connector must be American Connector WT-WSC series stainless steel Check to ensure you have all connector components Compression ring Connector nut Remove enough armor so the conductors can be easily spliced inside the enclosure. To avoid damaging the insulation on the conductors it is advisable to leave the white inner jacket until you insert the cable into the enclosure. Strip the black outer jacket to the length specified in the connector instructions. Inspect the edge of the armor for any burrs or sharp edges. Flatten or remove as necessary with needle nose pliers. Slide connector nut and compression ring over cable sheath/jacket Note: for detailed instructions on preparation of cable, including removal of armor, see the VITALink Installation Manual. Connector Gasket Locknut 3 4 Screw connector onto sheath and continue until tight. Tighten the connector nut onto the connector. Use channel locks as necessary.

3 Straight Through Tape Splice Installation Read Section completely before beginning installation 1 Secure Cable and Grounds 2 Remove Inner Jacket Prepare box cutouts and file sharp edges as needed. Clean up any metal shavings or oil. Some boxes come pre-cut. Install stainless steel breather drain on bottom of box. Ensure rubber gasket is on connector and insert cables into enclosure taking care not to nick or cut the cable core. Attach and secure the MC connector to the steel box using the locknut. Attach the earth tag and secure second locknut to the MC connector. Attach bare ground or Firewall LSZH green ground to the earth tag and ground stud to bond the connector and box to ground. Taking care not to nick or cut the black insulation, carefully remove the white inner belting material leaving minimum of ½ inch where the cable exits the threaded part of the MC connector. One method to accomplish this is to cut through the end of the inner jacket ½ inch inward and use your hands to peel the jacket back. This is preferred over scoring the jacket lengthwise down the cable because it eliminates the risk of cutting the insulation accidentally. Damage to the insulation will require a new piece of cable. 3 Splice Layout and Crimp 4 Silicone Tape Each crimp shall be cut so that they are staggered in the box when complete (see picture in step 7). It is recommended to train the conductors where the crimp will be located before cutting. This will help with the splice layout. Respect bend radius limits. See Step 7 for layout. Crimps should not line up vertically. Cut the ends of the cable square and carefully remove the black insulation to expose the amount of conductor specified by the manufacturer of the copper compression two-way splice connector barrel. Connect the conductors together using the appropriate copper compression two-way splice connector and crimping tool. Verify crimp is not loose. The first tape to apply is the gray colored supplied self-fusing silicone rubber. Several silicone tape wraps shall be applied with tension, and one final layer shall be applied without tension. Instructions are provided below. Take care to keep tape clean. Dirty tape shall be discarded. It is critical that the silicone tape stays clean. Start the tape 1.5 inches back from the end of the insulation and tape over the conductor insulation. Pull tape with moderate tension (50% to 100% elongation) and begin to wrap helically towards crimp. Stretching the tape is required to cure the material. 50% Overlap is required. Each wrap of tape shall overlap onto itself half way. Continue over the bare conductor, the crimped connection, and extend 1.5 inches over the insulation on the opposite conductor. This is one pass. The next pass would follow the same process in reverse. There is not a need to cut the silicone tape after each pass. Continue this process. The number of required passes across the crimp, as described in the previous steps, to achieve the fire rating is shown in Table 2. One pass is defined as one pass across the crimp. For example starting 1.5inches from the left side of the crimp and continuing 1.5 inches past the right side of the crimp at 50% overlap is one pass. Returning to the starting position would be the second pass, so on and so forth.

4 Straight Through Tape Splice Installation Continued 5 Final Silicone Layer 6 Glass Protective Tape After silicone tape has been wrapped according to Table 2, apply a final layer of the self-fusing silicone rubber tape with zero stretch or tension. Press down to avoid the tape ends from lifting before fusing takes place. The Second tape to apply is the white fiberglass tape. Start ½ inch past the end of the first layer of the silicone tape and apply one layer over the silicone tape. Each wrap of tape should cover over the previous wrap half way. Cover all surfaces of the silicone tape. Be careful not to cut silicone insulation or silicone tape when cutting the glass tape Additional layers are not required after silicone tape is covered. Use hand and apply pressure around crimp to ensure tape is adhering well. 7 Train Cables 8 Clean Up, Final Inspection, Close Box It is important to train the cables neatly away from each other in the enclosure as shown. Avoid contacting the sides of the enclosure. Maintain at least a ½ inch spacing between the splices and the inside of the enclosure sides, top or bottom. Remove any loose debris from inside the box. Inspect box cover gasket for any damage and wipe clean if it is dirty. Secure the box cover and gasket to the box using the clips and tighten screws (not shown).

5 Table 2 Tape Passes, Box Sizes, and Two-Way Connectors Conductor Size 2 AWG 1 AWG 1/0 AWG 2/0 AWG 3/0 AWG 4/0 AWG 250 kcmil 350 kcmil 400 kcmil 500 kcmil 600 kcmil Conductor Number Insulation Thickness (mils) Number of Silicone Tape Passes Under Tension Connector Hub OD (In) Box Size WxHxD (In) 3 70 9 1.5 12x10x4 4 70 9 1.5 12x10x4 5 70 9 2 16x14x4 3 90 11 1.5 12x10x4 5 90 11 2 16x14x4 4 90 11 2.5 20x20x6 3 90 11 2.5 20x20x6 4 90 11 2.5 20x20x6 1 155 18 1.25 10x8x4 4 105 13 2.5 20x20x6 1 155 18 1.25 10x8x4 1 155 18 1.5 12x10x4 1 155 18 1.5 12x10x4 1 170 19 2 16x14x4 3 120 14 3 24x18x6 Thomas&Betts Two-Way Splice Connector Cat. No./Color 54507/ Brown 54508/ Green 54509/ Pink 54510/ Black 54511/ Orange 54512/ Purple 54513/ Yellow 54515/ Red 54516/ Blue 54518/ Brown 54520/ Green 750 kcmil 1 170 19 2 16x14x4 54523-TB/ Black RSCC Wire & Cable LLC. 20 Bradley Park Road East Granby, CT 06026 USA Tel: 860-653-8300 Fax: 860-653-8301 r-scc.com 11-1-16