ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Similar documents
Model Number Structure

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

Accessories (Order Separately)

Selector Switches 30-mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Operation Unit Colors

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment

K3MA-L. Model Number Structure. Ordering Information. Temperature Meter. Model Number Legend. List of Models

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

DisplayPort Extender over 2 LC Fibers

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

DVI Rover 700 User Guide

KHT 1000C HV-Probe Calibrator. Instruction Manual

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

1X4 HDMI Splitter with 3D Support

OM2000N INSTALLATION MANUAL

Model Number Structure

3G/HD/SD-SDI to HDMI Converter

User Manual. Model 1351 DVI Repeater with HDCP

USB-TG124A Tracking Generator User Manual

DisplayPort Extender over 2 LC Fibers

DisplayPort to VGA Converter

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

8-Port HDMI Splitter with Up Data SP-H User Manual V

Content. 3G SDI 4X1 Switcher 1 INTRODUCTION. 1 2 SPECIFICATION PACKAGE CONTENT PANEL DESCRIPTION CONNECTION AND OPERATION..

SuperSpeed USB 3.0 to HDMI Audio Video Adapter for Windows & Mac up to 2048x1152 / 1920x1200

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

Instructions. P MHz 1X/10X Passive Probe

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Model: UHD41-ARC. Installation Guide

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

User Guide. HDMI Active Cable Extender. DVI-7370c

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

4, 8, 16 Port VGA and Audio Extender / Splitter with Audio over Single CAT5

VGA to DVI Extender over Fiber SET

True RMS AC/DC Mini Clamp Meter

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

Photoelectric Sensors E3F2

2-Port Video Splitter USER MANUAL VS102

CVSB/ S-video/ HDMI to HDMI Scaler with 720p and 1080p Switching.

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

HDBaseT Extender Set 100m User Guide

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

8 Port HD/SD-SDI Switch

PicoScope 4000 Series PC Oscilloscopes

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Digital Lighting Systems. DIGTAN4-PRO Converts 4 PROTOCOL channels to 4x 0.5 V to 10 VDC Analog

32 Channel CPCI Board User Manual

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

HD/SD-SDI Pattern Generator

TC3301. User's Manual

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

CrystalView DVI Micro-DL Extender

Transvue HDMI 4K2K Scaler

SAFETY AND NOTICE TABLE OF CONTENTS

HDMI 1.3 Receiver over Signal. CAT5/CAT6 Cable. Model #: HDMI-C5-R-M. 1

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

LBC-HDBT LINK BRIDGE TM HDBASET HDMI TRANSMITTER SYSTEM

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

PoE Over Coax Extender Kit

DVI over Single CAT5 Series CV-117. DVI over Single CAT5 Direct Plug-in Extender. User Manual. Made in Taiwan

VideoSplitter HDMI 4K PT

SCALE & WEIGHT DISPLAYS

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

A new generation of access control.

R&S ZN-Z154 Calibration Unit Specifications

Cat. No. O008-E1-04 USER S MANUAL. 3F88L-160/162 Cam Positioner

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Kramer Electronics, Ltd. USER MANUAL. Model: VA-100P-5. Power Supply

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Accessories. Servo Motors. Servo Motors B-47. Accessories

VS-201H VS-401H VS-801H

R&S ZN-Z85 Switch Matrix Specifications

EXT-SDHDX. Mini SDI to HDMI Converter

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

Transcription:

CSM DS_E_1_1 Continuously monitor dust fallout and particles which detract from product quality. Compact design ideal for continuous monitoring Equipped with various interfaces such as a LAN port. Accurately measures airborne particles. One unit for measuring dust fallout and identifying dust sources For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Be sure to read Safety Precautions on page 4. Ordering Information Sensor Appearance Item (Measured particle diameter) Power Supply ZN-PD0-SA 0., 0.5, or 1.0 μm min. ZN-PD0C-SA * DC cable 5 μm (10 μm), 20 μm (0 μm), 50 μm min. ( ) is selectable. For temperature / humidity measurement ZN-PD50C-SA * ZN-TH11-S * Please choose this form when you buy with the calibration certificate. Contents of Certificate of Calibration Set: Calibration Certificate, Inspection Result, and Traceability Chart Options (Order separately) Shape Item (Applicable Standards) Rated Voltage AC adaptor (PSE) 100 to 125 VAC ZN9-ACP02-PSE AC adaptor (CCC) 100 to 240 VAC ZN9-ACP02-CCC AC adaptor (KC) 100 to 240 VAC ZN9-ACP02-KC AC adaptor (CE) 100 to 240 VAC ZN9-ACP02-CE AC adaptor (UL) 100 to 125 VAC ZN9-ACP02-UL Appearance Item Change filter set for Particle measurement type For Dust measurem ent type ZN9-PF1-S Change filter ZN9-PF2-S Change funnel ZN9-PG1-S Exhaust tube (4 m) ZN9-PT4-S Exhaust tube (8 m) ZN9-PT8-S Filter for cleaning ZN9-PC1-S DC cable (2 m) Straight type ZN9-ED01-S Right angle type (comes with ZN-PD@@-SA) ZN9-ED02-S 1

Appearance Item Connection cable for air particle sensor (With connectors at both ends, length: 0.1 m) ZN9-TL01-S Connection cable for air particle sensor (With connectors at both ends, length: 2 m) ZN9-TL20-S Connection cable for external device (With a connector at one end, length: 2 m) ZN9-TC20-S PC Software Appearance Item Wave Inspire ES ZN-SW11-S Note: System requirements OS: Windows XP / Windows Vista / Windows 7 (64 Bit not supported) CPU: compatible Intel processors, 1 GHz or higher. Memory: 1 GB or more (2 GB or more recommended) The maximum number of connectable sensors is 95. (When one PC is connected with a leased line network. The sampling period is set to 10 minutes.) The number of possible sensor connections changes by a sampling period, connected number of PC or PLC, and the network load situation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Calibration service Subject to calibration Content Calibration Certificate, Inspection Result, Traceability chart ZN9-PD0C-S Calibration Certificate, Inspection Result, Traceability chart ZN9-PD50C-S Calibration Certificate, Inspection Result, Traceability chart ZN9-TH11C-S Note: 1. If a Certificate of Calibration is required after you purchase the product, use the above model number to order one. 2. It is necessary to ship the product back to OMRON in Japan. 2

Ratings and Specifications Item ZN-PD0-SA 90 sideways light-scattering method Semiconductor laser *1. ( ) is selectable. The maximum particle diameter that can be measured is approximately 200 μm. (When the pre-filter is attached.) *2. AC adaptor is not bundled. Item ZN-TH11-S Supply voltage 12 to 24 VDC ±10% Ripple (p-p): 10% max. Current consumption 40 ma max. Range 25 to +60 C Temperature Measurement accuracy ±0. C (at 25 C) Resolution 0.1 C Range 0% to 99% Humidity Measurement accuracy ±2.5% (at 25 C, 10% to 85%) Resolution 0.1% Indicator Alarm LED on the body Alarm threshold Threshold can be set for temperature, humidity or dew point. Data update cycle 10 s Serial communication standard RS-422 (Compoway/F) Measurement method Light source Measured particle diameter 0., 0.5, or 1.0 μm min. 5 μm (10 μm), 20 μm (0 μm), 50 μm min. *1 Particle concentration 0 to 100,000 particles/cf 0 to 50,000 particles/cf Sample flow rate More than 2.8 Liter/min More than 6.0 Liter/min Status outputs (2 outputs) System error status output Trigger Input Communications interface Communications protocol Indicators Measure mode Power supply voltage Current consumption Ambient temperature range Photocoupler output (Status outputs linked with clean levels) Photocoupler input Ethernet (10BASE-T, 100BASE-TX) Socket (TCP), original protocol Clean Level: 4 steps display according to clean level (adjustable) 7-segment main display (red): Measurement value (For particle count, the three type displays are selectable; particles/cf, particles/liter and particles/measurement time, With ZN-TH11-S; temperature, humidity and dew point) 7-segment sub-display (green): Threshold particle diameter, With ZN-TH11-S; t (temperature), rh (humidity), dp (dew point) Real-time mode (by second) / Cycle mode (by set cycle) / Trigger mode (by trigger) 18 to 25 VDC AC adapter: 100 to 240 V / 50 to 60 Hz *2 1A MAX Operating: 0 to 5 C Operating: 0 to 40 C Storage: 15 to +50 C (with no icing or condensation) Ambient humidity range Operating and storage: 5% to 85% (with no icing or condensation) Insulation resistance 20 MΩ min. at 500 VDC Withstand voltage 1,000 VAC, 50/60 Hz for 1 min Vibration resistance 110 to 55 Hz, 0. mm double amplitude, 50 min Materials ABS Degree of protection IP20 Installation method DIN track mount / Self standing Weight (Packed state) Approx. 1.7 kg Accessories Instruction Sheet, Air-intake tube (Tubing ID: 10 dia., Instruction Sheet, Air filter x1, Funnel x1 Length 1 m) x1, DC cable (Right angle type), Ferrite core DC cable (Right angle type), Ferrite core Note: 1. Power is supplied from the. 2. Connection cable (Type ZN9-TL@@) is needed to connect with ZN-PD-S.. If the following sticker is affixed to the connection port on the top of the, the cannot be connected. ZN-RD11-S dedicated port; cannot be used to connect to a PC. The can be connected if the sticker states Option unit connection port; do not use to connect to a PC. (This corresponds to products shipped starting in November 2009.) 4. Dirt or other foreign materials affixing to the sensor surface during operation may lead to deteriorations in precision. Therefore, we recommend that the sensor be calibrated once per year. 5. After ZN-TH11-S is kept in high humidity environment (more than 80%) for a long time, humidity measurement values might shift (approx +% with 60 hrs). In that case, the ZN-TH11-S needs to be kept in room temperature and humidity for more than 1 day.

Safety Precautions WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. For technical information and product FAQs, refer to the Technical Guide on your OMRON website. Dimensions () ZN-PD0-SA 0 0.7 (Unit: mm) Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. 120 18 85 Air Intake (10 dia.) LAN Port 90.7 110 Input/Output 7.4 DC cable/ AC adaptor 10.7 61 85.7 (0.7) (14) Air Outlet (10 dia.) 68 26 () 0 57.9 dia. 0.7 120 90.7 85 4. Air Intake LAN Port 110 Input/Output 7.4 DC cable/ AC adaptor 10.7 61 85.7 (0.7) (14) Air Outlet (10 dia.) 68 26 ZN-TH11-S.5-dia. Mounting Hole 16 8.9 14 dia. 28.1 Two,.5-dia. Mounting Holes.9 76.4 67.5 2-M 67.5±0.2 52.7 12 Standard Length 1 m 0.2 2.2 Mounting Screw Holes 11 2.4 1.1 6 5 4

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 201.6 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 201 All Right Reserved.