ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Similar documents
Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Photoelectric Sensors E3F2

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Absolute Rotary Encoder E6CP

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

Model Number Structure

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Safety Light Curtains

EVENT INPUT/OUTPUT MODULE [PUME]

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

ABS ST700 Compact Type Series

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Operating Instructions

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Bimetal Temperature Switch

I-SERIES. A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement

Solid-State Digital Timer

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Hybrid Chart Recorder 250 mm (10")

W100L: Laser Sensor in Mini- Format

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Ø50mm Shaft Multi-Turn Absolute Type

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Fibre Optic Modem ODW-611

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Self--powered Time Counter

Electrical connection

Digital Flow Switch for Large Flow

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Single Point Flow Monitor SW118 SW119

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Type Contact form Model

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Process Transmitter RMA 422

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

ODW-621. RS-232 Point-to-point applications

Photoelectrics Through-beam Type PA18C.T..., DC

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

Separate Thin Amplifier type. AP-V40AW Series

L-LAS Series L-LAS-LT-2500-XL. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-2500-XL

Fibre Optic Modem ODW-622

LONWORKS Fibre Optic Converter

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

V 180 Series Photoelectric Switches

Accessories (Order Separately)

APPLICATIONS. Automatic warehouse. Trasportation lines

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

SU17 Series Fiber Optic Sensors

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

Cylindrical Photoelectric Sensor CY-100 SERIES

Type F70AB F70ABPN. Digital display. Simple operation featured

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Product Data Sheet 4656 EZ

OM2000N INSTALLATION MANUAL

Product Data Sheet 4656 ZW

DIN Connectors DIN06 E-03

Electrical connection

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Safety Light Curtain Type4 SIL3 PLe

SCALE & WEIGHT DISPLAYS

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

OPTICAL POWER METER WITH SMART DETECTOR HEAD

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

LD OEM/LD PDS/LD PeCo

No Need to Select. Intensity Detection (Previous Type)

ED5229GT-E Series. Page 1 of 8

Detect Color and Shape for various inspection

Product Data Sheet 8506 VW-691

Multifunction Digital Timer

Linear encoders without bearings incremental System for linear motion feedback

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Transcription:

Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page 1260. Features Cleaning / Smallest in the Industry! Air Particle Sensor for In-line Measurement A high-performance fan for external air suction enables constant measuring over long periods. Semiconductor laser and highsensitivity optical design in the sensing section enable measurement of 0.-µm particles. Laser beam Airflow Measurement Principle A semiconductor laser beam is targeted on to the air intake and the light is scattered when particles pass through that beam. The scattered light is received by the light receiving element and converted to an electrical signal. Particle Trend Indicator The sensing section has a particle trend display for quick visual confirmation of the degree of cleanliness. The Amplifier provides numeric indication of the number of 0.-, 0.5-, and 1.0- Particle Numeric Display Particle Trend Display µm particles. A signal can be output at any level of particles if a threshold has been set. 1256

On-screen Indication and Data Logging of Particle Amount Measurement values can be easily logged on a personal computer by using the Interface Unit and special software (sold separately). Data from sequential sensing of particles can be used to improve quality. Realtime Clean Air Monitor A variety of displays (including color graphs for visual confirmation by color of particle densities, indication of the number of particles, and trend graphs) can be set. Particle Sensors and Interface Units can also be set from the personal computer. Measurement data is logged in real time and can be manipulated in CSV-format files using spreadsheet software. Quality Control with Multi-point Measurement Patent Pending Up to 10 Particle Sensors and up to 9 Air Clean Units can be controlled through one Interface Unit and Realtime Clean Air Monitor. There are no time-consuming restrictions, such as the order that power is turned ON. The level of cleanliness can be controlled for each process and constant monitoring is possible in relation to quality data. Cleaning / Electrostatic Sensor Air Clean Unit air volume settings, operation, and errors can be checked on the Amplifier or Interface Unit. Multi-point data output No. of connectable Sensors: 10 max. For In-line Applications Installation is simple with DIN Track mounting. The In-line Air Particle Sensor was developed for in-line applications, with a 24- VDC power supply. External outputs can be at two levels: warning and alarms. Suitable for in-line trend management applications. 1257

Ordering Information Air Particle Sensors Sensor Head Appearance Measured particle diameter Model 0. µm/ 0.5 µm/ 1.0 µm 0 Amplifier Units Appearance Power supply Connection method Model 24 VDC Cable connection A11 Supplied from the Air Clean Unit Connector connection (Air Clean Unit feedback connection) A12 Calculating Unit Appearance Model Cleaning / ZX-CAL2 Clean Monitoring Appearance Contents Connection method Model Set Including Communications Interface Unit and Realtime Clean Air Monitor For RS-22C connection with personal computer only For RS-22C connection with personal computer or Air Clean Unit feedback connection ZN-SFW11 ZN-SFW12 Double-sided Connector Cables (for extension between Sensor Head and Amplifier) Cable length Model Quantity 1 m ZX-XC1A 1 4 m ZX-XC4A 1 8 m ZX-XC8A 1 Type Model Quantity Sensor Head Replacement Filter Set ZN9-PF1 1 Cleaning Filter ZN9-PC1 1 Head Attachment Tool ZN9-PB1 1 1258

Ratings and Specifications Air Particle Sensors Sensor Head Item Model 0 Applicable Amplifier Measurement method Light source Applicable particle size Applicable cleanliness class Indicator Connection tube Ambient temperature Ambient humidity Dielectric strength Vibration resistance Shock resistance A11/A12 90 sideways light-scattering method Semiconductor laser 0., 0.5, or 1.0 µm min. Equivalent to Class 100 to 100,000 (FED-STD-209D) Level indicator for Class 100 to 100,000 (FED-STD-209D) Inner diameter: 4, Length: 1 m max. Operating: 0 to 40 C, Storage: -15 to 50 C (with no icing or condensation) Operating and storage: 5% to 85% (with no condensation) 1,000 VAC 50/60Hz for 1 min 10 to 55 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions 150 m/s² times each in six directions (up/down, left/right, forward/backward) Connection method Cable (standard cable length: 0.5 m) Materials ABS Weight (packed state) Approx. 00 g (Packed state: Approx. 0 g) Amplifier Units Instruction sheet, connection tube Item Model A11 A12 Sampling time 1 to 599 s (selectable) Average count setting 1, 2, 4, 8, 16, 2, or 64 Indicators Status outputs (2 outputs: OUT1/OUT2) * Reset input * Functions Communications with Air Clean Unit Power supply voltage Current consumption Operation indicators: OUT1 (orange), OUT2 (yellow), 7-segment main display (red), 7-segment sub-display (yellow), power (green), wide range display (green), unit selection display (green) NPN open-collector outputs, 0 VDC, 0 ma max., Residual voltage: 1.2 V max. ON: Short-circuited with 0-V terminal or 1.5 V or less, OFF: Open Measurement result display, Setting value display, Unit selection, Scaling, Peak hold, Hysteresis setting, Threshold level selection, Wide range display, Key lock, ECO mode, Display reverse, Display digit change, Initialize 24 VDC ±10%, Ripple (p-p): 10% max. 00 ma max. 7-segment main display (red), 7-segment sub-display (yellow), power (green), wide range display (green), unit selection display (green) Measurement result display, Communications condition display, Unit selection,scaling, Air Clean Unit automatic control, Air Clean Unit air level change,threshold level selection, Wide range display, Key lock, ECO mode, Display reverse, Display digit change, Initialize Unique communications specifications (RJ- connector and straight LAN cable) 24 VDC ±10%, Ripple (p-p): 10% max. (Supplied from Air Clean Unit) Cleaning / Ambient temperature Ambient humidity Insulation resistance Dielectric strength Vibration resistance Shock resistance Operating: 0 to 40 C, Storage: -15 to 50 C (with no icing or condensation) Operating and storage: 5% to 85% (with no condensation) 20 MΩ min. at 500 VDC 1,000 VAC, 50/60 Hz for 1 min 10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions 00 m/s² times each in six directions (up/down, left/right, forward/backward) Connection method Cable (standard cable length: 2 m) Connector Cable (standard cable length: 2 m) Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate Weight (packed state) Approx. 180 g (Packed state: Approx. 50 g) Instruction sheet * OUT2 and the reset input are switched by using the DIP switch on the bottom of the Amplifier. 1259

Clean Monitoring Item Model ZN-SFW11 ZN-SFW12 Power supply voltage Current consumption Applicable Amplifiers Applicable Amplifier Unit software version Supplied from the A ma max. with 24-VDC power supply voltage (excluding current consumption and current output of the Amplifier) ZX Series, ZJ-SD Series, Series ZX-LDA@@-N V1.000 or higher, ZX-EDA@@ V1.00 or higher, ZX-TDA@@ V1.100 or higher, ZJ-SDA@@ V1.000 or higher, or A@@ V1.000 or higher No. of connectable Amplifiers 10 max. (For A) Indicators Power: Green, Sensor communications: Green, Sensor communications error: Red, External terminal communications: Green, External terminal communications error: Red Power (POWER: Green), Serial communications (STA1: Green) Not clean (OPE1: Orange), Clean (OPE2: Green) Functions Automatic control for Air Clean Units (multi-unit system control), Air level change for Air Clean Units Communications port RS-22C (9-pin, D-Sub connector) Protocol CompoWay/F Cleaning / Communications Baud rate Data configuration For external device 2 8,400 bps Data bits: 8, Parity: None, Start bits: 1, Stop bits: 1, Flow control: None Unique communications specifications (RJ- connector and straight LAN cable) Ambient temperature Operating: 0 to 40 C, Storage: -15 to 50 C (with no icing or condensation) Ambient humidity Operating and storage: 5% to 85% (with no condensation) Insulation resistance 20 MΩ min. at 500 VDC Dielectric strength 1,000 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions Shock resistance 00 m/s² times each in six directions (up/down, left/right, forward/backward) Connection method Connector cable (standard cable length: 2 m) Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate Weight Approx. 100 g (Packed state: Approx. 480 g) Approx. 200 g (Packed state: Approx. 550 g) CD-ROM (Realtime Clean Air Monitor), Instruction Sheet, Two clamps System Connection Diagram Please refer to System Connection Diagram on page 1249 for details. Safety Precautions Refer to Warranty and Limitations of Liability on page F-2. WARNING This product is not designed or rated for ensuring safety of person. Do not use it for such purpose. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. 1260

Dimensions (Unit: mm) Air Particle Sensors 0 Sensor Head Mounting Tool When ZN9-PB1 is used (Sold separately) 46 14. 76 120 Air inlet 21.5 70 14.4 9.4 22.4 15.85 6.8 5 25 70±0.1 70 5.2-dia. vinyl-insulated round cable with 10 conductors, standard length: 0.5 m 44 22 Exhaust outlet Two, -dia. holes Mounting hole cutout dimensions Mounting screw holes Two, M4 holes, depth: 6 42 2.6 Mounting plate Two, M4 6 mounting screws (90) 4 82 4 82±0.1 5 Six, M Mounting hole cutout dimensions 5 Oblong holes for mounting Six,.2 6.2 holes A11 Range indicator Unit indicator A12 Range indicator Unit indicator Modular jack 0 15.5 dia. 1.2 OUT1 indicator OUT2 indicator (1) 44 5.1-dia. vinyl-insulated round cable, standard length: 100 mm 1 64. 6.8 Main digital indicator Sub-digital indicator 15.8 Status output 6 16.8 1.5 5.2-dia. vinyl-insulated round cable, standard length: 2 m Status output OUT2/reset input switch (default setting: status output) 0 15.5 dia. 1.2 OUT1 indicator OUT2 indicator (1) 44 5.1-dia. vinyl-insulated round cable, standard length: 100 mm 1 64. 6.8 Main digital indicator Sub-digital indicator 21.46 6.6 16.8 1.5 6 5.1-dia. vinyl-insulated round cable with 10 conductors (conductor cross-section: 0.08 mm², insulator diameter: 0.7 mm), standard length: 2 m 15.8 Cleaning / Interface Units ZN-SF11 ZN-SF12 Sensor communications indicator (communicating) Sensor communications indicator (communications error) Link connector Status indicator Modular jack 0 15 1.2 (.1) Connector (46) (6) 5.2-dia. vinyl-insulated round cable, standard length: 00 mm 64. 1 6.8 External terminal communications indicator (communicating) External terminal communications indicator (communications error) 1.5 4. 6.55 5 0 15 (.1) 1.2 Operation indicators (6) (46) 5.2-dia. vinyl-insulated round cable, standard length: 00 mm Connector 1 64. 6.8 4. Main digital indicator Sub-digital indicator 6.55 5 21.46 6.6 15.8 1.5 5.1-dia. vinyl-insulated round cable with 10 conductors (conductor cross-section: 0.08 mm², insulator diameter: 0.7 mm), standard length: 2 m Cat. No. E872-E1-01 In the interest of product improvement, specifications are subject to change without notice. 1261