A Noble Identification System for Tumors and Implementation

Similar documents
Comp 410/510. Computer Graphics Spring Introduction to Graphics Systems

IC Design of a New Decision Device for Analog Viterbi Decoder

TV Character Generator

A First Laboratory Course on Digital Signal Processing

(12) United States Patent (10) Patent No.: US 6,462,508 B1. Wang et al. (45) Date of Patent: Oct. 8, 2002

GSK988T TURNING CENTER CNC SYSTEM

Failure Analysis Technology for Advanced Devices

1000TII TURNING CNC CONTROLLER

Pivoting Object Tracking System

A BCI Control System for TV Channels Selection

The Design of Teaching Experiment System Based on Virtual Instrument Technology. Dayong Huo

How to Manage Color in Telemedicine

Amplification. Most common signal conditioning

SPR-11P Portable Transport Stream Recorder and Player

IN DIGITAL transmission systems, there are always scramblers

CHAPTER 8 CONCLUSION AND FUTURE SCOPE

USOO A United States Patent (19) 11 Patent Number: 5,822,052 Tsai (45) Date of Patent: Oct. 13, 1998

High Speed Async to Sync Interface Converter

Chapter 9 MSI Logic Circuits

Advanced Test Equipment Rentals ATEC (2832)

Broken Wires Diagnosis Method Numerical Simulation Based on Smart Cable Structure

MODEL 5493A DTMF MODEM

Tools to Debug Dead Boards

Initial Experience With Automatic Image Transmission to an Intensive Care Unit Using Picture Archiving and Communications System Technology

In-process inspection: Inspector technology and concept

Hardware & software Specifications

Prototype Model of Li-Fi Technology using Visible Light Communication

A Modified Static Contention Free Single Phase Clocked Flip-flop Design for Low Power Applications

HDMI Extender via 4 Single-mode fibers 4 x LC Connector Extends HDMI + RS232 full-duplex up to 1500 meters

Part 1: Introduction to Computer Graphics

Explorer Edition FUZZY LOGIC DEVELOPMENT TOOL FOR ST6


BUSES IN COMPUTER ARCHITECTURE

Modulation transfer function of a liquid crystal spatial light modulator

IOT BASED ENERGY METER RATING

CABLE MODEM. COURSE INSTRUCTOR Prof.Andreas Schrader

Advanced Setup Guide

medlab One Channel ECG OEM Module EG 01000

Computer Graphics. Introduction

Module 7. Video and Purchasing Components

Press Publications CMC-99 CMC-141

ECE 372 Microcontroller Design

DMX 512 Language Date: Venerdì, febbraio 12:15:08 CET Topic: Educational Lighting Site

Luis Cogan, Dave Harbour., Claude Peny Kern & Co., Ltd 5000 Aarau switzerland Commission II, ISPRS Kyoto, July 1988

In the development of electronic instruments or the analysis

Equivalence Checking using Assertion based Technique

Interfacing Analog to Digital Data Converters. A/D D/A Converter 1

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

International Journal of Emerging Technologies in Computational and Applied Sciences (IJETCAS)

arxiv:hep-ex/ v1 27 Nov 2003

APPLICATIONS OF DIGITAL IMAGE ENHANCEMENT TECHNIQUES FOR IMPROVED

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

Agilent I 2 C Debugging

METHOD, COMPUTER PROGRAM AND APPARATUS FOR DETERMINING MOTION INFORMATION FIELD OF THE INVENTION

Vision Standards Bring Sharper View to Medical Imaging

Design and Implementation of a Digital Teleultrasound System for Real-Time Remote Diagnosis

There are many ham radio related activities

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL*

Logic Devices for Interfacing, The 8085 MPU Lecture 4

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Video Scaler Pro with RS-232

REDUCING DYNAMIC POWER BY PULSED LATCH AND MULTIPLE PULSE GENERATOR IN CLOCKTREE

Low-speed serial buses are used in wide variety of electronics products. Various low-speed buses exist in different

Workshop 4 (A): Telemetry and Data Acquisition

Single mode 9/125µm, duplex

CAPTURE CAPTURE. VERSiON 1.2. Specialists in Medical. Digital Imaging Solutions

THE STRUCTURE AND ADVANTAGES OF DIGITAL TRAINING SET FOR COMPUTER ENGINEERING

Image Acquisition Technology

How to Chose an Ideal High Definition Endoscopic Camera System

Electronic Grocery Machine

World First Slim Cassette Type Digital Mammo. Upgrade Solution

Downloads from:

1ms Column Parallel Vision System and It's Application of High Speed Target Tracking

Product Information. EIB 700 Series External Interface Box

Design for Testability

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

Images for life. Nexxis for video integration in the operating room

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

Alice EduPad Board. User s Guide Version /11/2017

HEART ATTACK DETECTION BY HEARTBEAT SENSING USING INTERNET OF THINGS : IOT

HDMI / Video Wall over IP Receiver with PoE

MTL Software. Overview

Log-detector. Sweeper setup using oscilloscope as XY display

Notes on Digital Circuits

Guide to Network Video Applications AXIS 2120

Patient centric Medical Database with Remote Urinalysis Test

AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR

PHASE-LOCKED loops (PLLs) are widely used in many

Semiconductors Displays Semiconductor Manufacturing and Inspection Equipment Scientific Instruments

Types of CRT Display Devices. DVST-Direct View Storage Tube

Reconfigurable Neural Net Chip with 32K Connections

SCode V3.5.1 (SP-601 and MP-6010) Digital Video Network Surveillance System

High Performance Raster Scan Displays

CHARACTERIZATION OF END-TO-END DELAYS IN HEAD-MOUNTED DISPLAY SYSTEMS

Contents on Demand Architecture and Technologies of Lui

Assignment No: 01 Subject: Microwaves and Antennas Subject Code: 15EC71 Name of the faculty: Raghu B R Semester: VII (A and B)

Real-time Chatter Compensation based on Embedded Sensing Device in Machine tools

Digital picture transmission between Antarctica and India

Transcription:

A Noble Identification System for Tumors and Implementation SHIEH-SHING LIN A, KING-TAN LEE B, JIA-HAU CHEN C, HEN-CHIA HSU D, a,c,d Department of Electrical Engineering St. John s University #499, Sec. 4, Tam-King Rd., Tamsui, Taiwan, R. O. C. b Department of Electrical Engineering Lee-Ming Institute of Technology #2-2, Lijuan Rd., Liming, Taishan, Taipei, Taiwan, R. O. C. Chihlee Institute of Technology Curriculum Section staff #313, Sec. 1, Wunhua Rd., Banciao, Taiwan, R. O. C. a sslin@mail.sju.edu.tw Abstract: - In this paper, we present a noble identification system for tumor and implement the proposed method in identifying the tumors X-ray data. First, based on the micro-control equipment, we design an identification system that owns the comparison function. The identification system owns the following attractive features: i. the identification system has high accuracy in comparison ability. If there is a slight deviation of a tumor, the identification system points out the coordinate of the tumor. This function of the identification system reduces the working time of the doctors and decreases the misjudging cases. ii. After the judgment of the X-ray data, the suspected tumors position was shown on the display board. We can also transform the patients tumor data through the network. This special feature helps in group-doctors inter-meeting. Key-Words: Micro-control equipment, Identification system, Network transmission, Tumors 1 Introduction The busy life makes people neglect their own health. But now they are gradually conscious of being healthy. To maintain physical health has also become one of the most important issues. And to conduct physical examinations regularly is the best way for them to study the status of themselves. X-ray is just the essential part in physical examinations. It could be used to check whether there is any abnormal case in every part of the body. In origin, physicians diagnose X-rays directly with naked eye that they discriminate between 2 X-rays. But some subtle changes are unnoticeable, which have to be carefully observed. In some general hospitals, a doctor has to examine 100-bit of patients in the morning. After implement the National Health Insurance, the surge in the number of out-patient has come out. If the physicians keep using the same way, the result will be decreased efficiency or even the misjudging cases. X-rays and issued by the message, only physicians can read, the family could not understand, and past medical treatment, patient referral to other hospitals, with their own to the original X-rays go north-south, ISSN: 1109-2777 65 Issue 1, Volume 8, January 2009

very inconvenient and delaying treatment. So in the paper, we designed the system to reduce the burden on physicians. The paper is organized in the following manner. Section 2 presents the system architecture. Testing operation procedure is given in Section 3. Section 4 provides the Simulation. We make a brief Conclusion in Section 5. 2 System Architecture 2.1 Scanners 2.1.1 Image scanning mode 16 color computer image, but the black-and-white X-ray colors, we will be closer to the computer in 16 colors of the X-ray color black, dark grey, grey, white four-color to color with a 16 to set the key link Technology [1] [2] [3] to the original performance of the X-ray shadow. 2.1.2 Part scanner We design the system scan [4], the use of Y-axis stepper motor control, to strip the optical scanning machines, so X-axis plane of the scanner. 2.1.3 Scanner driver Control command will be applied in the CONFIG.SYS file written DEVICE = C: \DISKSCAN\MINI400I.SY. DEVICE= C:\ DISKSCAN\SJIIX.SYS This correspondent necessary to boot load, without the load, the scanner will not start, as the scanner will not take action, that is, whether there is a view driver s load. 2.1.4 Scanning part The system uses HP SCANJET II cx as the scanning device. The usage of optical scanners is to scan the color histogram 256, on 425*667 resolutions scanning, and every point with 1 byte capacity storage, an X-ray film should be 283K capacity to store. 2.2 Display part 8255: PPI short, the internal block diagram can be divided into three major parts, namely the CPU interface part A, part B group control, and I / O part. 2.2.1 Part of CPU interface With 8-bit data buffer and the convergence of read / write control logic and data convergence for a buffer of energy (Enable) duplex control of the buffer gates, 8255A CPU and provide internal bus of information access path. 2.2.2 A, B control of the group 8255A internal divided into two groups, that is, Group A and Group B, the part of the control group could write the word control group (Control Word) to determine the I/O ports and the mode of operation of the direction of data transmission. 2.2.3 I/O part Three sets of 8-bit I/O ports, A port (PA), B ports (PB), C ports (PC), where A port of Groups A and B ports belonging to Group B, C port the first half (PC7 ~ PC0) are Group B, and C port can be individually also as a complete 8-bit I / O ports. 2.3 Transmission We use a modem for data transmission [5], data-that is, digital and analog computer world of the telephone network media. Ordinary telephone lines only transmission of audio signals, the computer can not be transmitted by the use of digital signals. Data for the work that is sent from the client computer to receive digital information will be converted to analog audio signals transmitted through the telephone line, the receiving end of the data received since the telephone line to analog audio signals, will be the conversion of digital signal, then pass computer, so can transfer and exchange information to achieve the purpose. 2.4 The scanning comparison part ISSN: 1109-2777 66 Issue 1, Volume 8, January 2009

So by the scanners first two X-ray all the graphics files and then file for each data point code by comparison, the error will be larger than the location of three bands, to be marked special mark (on the system we designed, 256 bands on the computer for color layers, the test after that experience, typewriters or printed, the histogram will be more than 256 bands, and color level is less than 3 bands may have been in part caused by the scanning errors, it be ignored). Repeatedly scan times, the most discriminator a special mark-intensive part (which may be the location of lesions), fuzzy theory, every punctuation to the straight distance between select the geometric center, then as a center, and the most remote of punctuation for the radius, Circle, and this circle that is representative of the representative of the scope of diseases. 3 Testing operation procedure The operation of the system to facilitate friendly and the principle of avoiding all the complicated procedures of the operation, even if the computer is never been involved in, you can easily control the system [6-8]. Operation flow chart shown in Fig. 1: Step 1: various peripheral devices (such as modems, scanners ) for the power plugs connect, and open the power supply. Step 2: Type the file into the system's operating mode. Step 3: According to the functional requirements into different windows, and options can be. 2.5 Boarding part 8255A with the use of a computer interface hardware circuit, when the program to determine location of lesions, the computer will be a signal transmission 8255A (lesions in the body organs of the relative position), and will thus 8255A signal and then output to their relative organ name of the show should be light. However, as the output signal of the 8255A is a small voltage, not enough to show that light moves, therefore, by using opt coupler (4N25) as a switch, when 8255A drive to a voltage opt coupler, will move opt coupler so that the 12V power on, and then enable the transistor (2AS1015). 2.6 The modem enactment part Computer information system sent a signal to the first buffer, and then sent to the remote modem, if the buffer is going at full load, data-informed computer systems that transmit data suspended until the buffer, while stock information faster, data-only notify the computer system will send out information. Usually for process control data can be divided into software and hardware in two ways. (1) Hardware flow control that is the use of RS232 RTS and CTS signals for control. (2) Process control software is sent XON 'or' XOFF 'control code to deal with them. And the use of the system software flow control, we will be described in the above section. 3.1 A procedure of the proposed X-ray scanning Proc.1 Entering menu select 'file operations'. Proc.2 From the list of patients choose using the system of patients (if the new patients, please menu 'new file', type information). Proc.3 The selection of patients will be automatically entered to the operating menu. Proc.4 Select the 'X-ray scan' in the 'Start scanning'. Positioning points can be set in accordance with the different habits of physicians and settings, its purpose is to make X-ray scan, a more accurate positioning. Proc.5 Operating returns to the page on the menu, select the 'X-ray comparison'. Proc.6 Selected base map reference and comparison chart code, you can choose 'more', began operations. Photograph shows usually normal date from the earlier examination. ISSN: 1109-2777 67 Issue 1, Volume 8, January 2009

ISSN: 1109-2777 68 Issue 1, Volume 8, January 2009

ISSN: 1109-2777 69 Issue 1, Volume 8, January 2009

Fig. 1 The completely flow chart of the proposed A noble Identification System for Tumors ISSN: 1109-2777 70 Issue 1, Volume 8, January 2009

Fig. 2 The figure panel of the proposed A noble Identification System for Tumors ISSN: 1109-2777 71 Issue 1, Volume 8, January 2009

Diagnosis of patients with single Name A No 00001 X-ray map benchmarks Indifications Physician System Diagnosis Remarks A0001 Patient A Normal X-ray Comparison Chart 2004/12/1 A0002 Diagnosis single code DKNO-931201 Fig. 3 The diagnosis of patient A 4 Simulation tests Patients medicals X-ray data is related to the privacy of individual medical records, and therefore, not easily been achieved, we are very grateful to the first hospital in Tamsui provided a simulation environment for us to test the proposed design. The proposed A noble Identification System for Tumors after some testing as to the scanning, scans, through analysis, there will be some anomalies in the panel display, as shown in Fig. 2. We made four tests, A, B, C and D; two years ago they go to the hospital for a health check. After detailed examination of its X-ray data are normal, and A, B, C and D of the X-ray codenamed A0001, B0001, C0001 and D0001. CASE 1A health check again, two years after the hospital examination, the doctor doing the same for its X-ray inspection, the computer scanned the results of output, and make a comparison with the normal data and find there is no abnormal situation. In Fig. 3 shows patient A of the X-ray diagnosis and we also can see from Fig. 2, figure panel of the proposed A noble Identification System for Tumors shows the normal signals. CASE 2B health checks, a year after, and he feel illness, and then goes to the hospital for an examination; doctors using the proposed design to do the same for its X-ray diagnosis. It (Fig. 4) shows that the coordinate (232,323) with 0.7cm diameter shadow. Furthermore, in Figure 2, figure panel of the proposed A noble Identification System for Tumors did not show its normal signal, the coordinates (232,323) corresponding body parts. Left lung s indicator has been seen the light on. But these will be further determined by the results of physicians in a professional doctor s judgment. CASE 3 C health checks again after two years of previous examination, and the doctor using the proposed design to do the same normal hospital examination by its X-ray inspection, the computer scan the results of output. It (Fig. 5) shows that the coordinate (35,413) with 0.5cm diameter shadow. Furthermore, in Fig. 2, figure panel of the proposed A noble Identification System for Tumors did not show its normal signal, the coordinates (35,413) corresponding body parts. Pancreas s indicator has been seen the light on. But these will be further determined by the results of physicians in a professional doctor s judgment. CASE 4 D health checks again after two years, and the doctor doing the same normal hospital examination by its X-ray inspection, the computer scan the results of output. It (Fig. 6) shows that the coordinate (141,396) with 0.6cm diameter shadow. Furthermore, in Fig. 2, the figure panel of the proposed A noble Identification System for Tumors did not show its normal signal, the coordinates (141,396) corresponding to Body parts. Liver s indicator has been seen the light on. But these will be further determined by the ISSN: 1109-2777 72 Issue 1, Volume 8, January 2009

results of physicians in a professional doctor s judgment. Diagnosis of patients with single Name B No 00002 Name D No 00004 X-ray map benchmarks Indifications Physician D0001 Patient D X-ray Comparison Chart D0002 X-ray map benchmarks B0001 X-ray Comparison Chart B0002 System Diagnosis Coordinate [141,396] diameter 0.6 cm shadow of suspected tumors, should have a detailed inspection. Indifications Physician System Diagnosis Patient B Coordinate [232,323], diameter 0.7 cm shadow of suspected tumors, should have a detailed inspection. Remarks 2004/12/1 Diagnosis single code DKNO-931205 Fig. 6 The diagnosis of patient D Remarks 2004/12/3 Diagnosis single code DKNO-931202 5 Conclusion Fig. 4 The diagnosis of patient B Diagnosis of patients with single Name C No 00003 X-ray map benchmarks Indifications Physician System Diagnosis Remarks C0001 Patient C X-ray Comparison Chart C0002 Coordinate [35,413], diameter 0.5 cm shadow of suspected tumors, should have a detailed inspection. 2004/12/1 Diagnosis single code DKNO-931203 Fig. 5 The diagnosis of patient C Diagnosis of patients with single We completed the design of the system, through the actual test, system functions in line with expectations. Our system has the following advantages: i. the identification system has high accuracy in comparison ability. If there is a slight deviation of a tumor, the identification system points out the coordinate of the tumor. This function of the identification system reduces the working time of the doctors and decreases the misjudging cases. ii. After the judgment of the X-ray data, the suspected tumors position was shown on the display board. However, these will be further determined by the results of physicians in a professional doctor s judgment. We also can transform the patients tumor data through the network. This special feature helps in group-doctors inter-meeting. After numerous simulations the proposed system obtains some successful results. Acknowledgement The authors would like to thank Editor and the anonymous Reviewers for their valuable suggestions and comments to improve the quality of this paper. This research work is supported in part by the National Science Council in Taiwan under Grant NSC97-2511-S-263-001. References ISSN: 1109-2777 73 Issue 1, Volume 8, January 2009

[1] K. Yea, FAX/MODEM Design, Taiwan Yi-Jong Company, Taiwan, 2005. [2] J. Huo, MODEM application, Chi-Fong Company, Taiwan, 2004. [3] J. Lie, Yie-Tien Chinese word system, Suo Kun Company, Taiwan, 2006. [4] R. Chen, TURBO C application, Jain-Yeu Company, Taiwan, 2003. [5] W. Jung, TURBO C Interface application of printer, Yi-Jong Company, Taiwan, 2004. [6] S. Yeu, X-Ray Cancer detection, Suo Kun Company, Taiwan, 2004. [7] K. Tsai, X-Ray Films discrimination, Suo Kun Company, Taiwan, 2001. [8] A. Lin, Scanner Control Language and C Language Library for HP-Packard Scanners, Y. Long Company, Taiwan, 2004. ISSN: 1109-2777 74 Issue 1, Volume 8, January 2009