3a Enclosed Type Molded Plastic Compact Design Impact-Resistant Molded Enclosures IP42 (Type 1) or IP66 (Type4/4X/12)Enclosure Ratings Solid-State Overload Relays Meets International Standards 109-C09KDA1E-1-4R1-7 TABLE OF CONTENTS Description Page Description Page Product Selection... 3-69 Accessories.... 3-89 Modifications...3-98 Approximate Dimensions...3-102 Description enclosed starters are designed using Bulletin 100 contactors (9 A through 23 A)and Bulletin 193 solid state overload relays ina molded enclosure.these molded enclosures are compact in design, which is essential where mounting space is a premium, yet they offer ample internal wiring space. Installation is made simple and wiring time is reduced with features such as conduit knockouts, pilot device knockouts and backed-out terminal screws. The enclosure base contains a metal 35 mm DIN Rail, which makes mounting the starter into the enclosure a snap. A-B EXPRESS Fast Shipment Program Fast Shipment of IEC Products to satisfy your unexpected demands Make your selections from any of the Cat. Nos. printed in blue and identify your order as A variety of accessories are available to allow flexibility in configuring the appropriate starter to satisfy most application needs. These full-voltage non-reversing starters continue the Bulletin 100 tradition by complying with both domestic and international standards. All starters include a normally open auxiliary contact as standard. Conformity to Standards: IEC 947 VDE 0660 UL 508 Approvals: cul US Your order must include: of the starter.. Overload Relay Suffix Code. If required, factory-installed modifications suffix code. If required, of any accessories. 3-68
Product Selection Enclosed Type Molded Plastic AC Operated Fast Shipment Program Cat. Nos. are printed in blue. Max [A] kw Ratings (AC3, AC4) IP42 (Type 1) General-Purpose Molded Plastic Enclosure IP66 (Type 4, 4X, 12) Watertight, Dusttight Corrosion Resistant Molded Plastic Enclosure 3 1 ➊ 3 380V/ 415V 115V 230V 200V 230V 460V 575V 9 4 1/3 1 2 2 5 7-1/2 109-C09B 109-C09K 12 5-1/2 1/2 2 3 3 7-1/2 10 109-C12B 109-C12K 16 7-1/2 1 3 5 5 10 15 109-C16B 109-C16K 23 11 2 3 5 7-1/2 15 15 109-C23B 109-C23K The as listed is incomplete. Select a from the table below to complete the Example: 109-C09B becomes 109-C09BA. Voltage 24V 48V 110V 120V 208V 220V V 277V 380V 415V 440V 480V 500V 600V Common Control 50 Hz A T N G B M 60 Hz H L A N B C Separate Control (without transformer) 50 Hz K Y D 60 Hz J X D T Overload Relay Code The as listed is incomplete. Select MCS-E1 solid-state overload relay code from page 3-87 to complete the Bi-metal and MCS-E2 overload relays are not available in molded plastic enclosed starters. Accessories Page 3-89 Modifications Page 3-98 Approximate Dimensions Page 3-102 3-69
3ó Enclosed Type Sheet Metal 109-C09ABA1F-1-4R-6P IP42 (Type 1) Metal Enclosure with Lift-off Cover Selection of Metal Enclosures IP42 (Type 1) and IP66 (Type 3/4/12) Compact Design Bimetallic Class 10 Overload Relays Solid-State Overload Relays Meets International Standards TABLE OF CONTENTS Description Page Description Page Product Selection... 3-71 Accessories.... 3-89 Modifications...3-98 Approximate Dimensions... 3-103and3-106 Description enclosed starters are designed using Bulletin 100 contactors (9 A through 608 A) and Bulletin 193 bimetallic (Class 10) or solid-state overload relays in a metal enclosure. All starters include a normally open auxiliary contact as standard. Conformity to Standards: IEC 947 VDE 0660 CSA 22.2 UL 508 Approvals: cul US A-B EXPRESS Fast Shipment Program Fast Shipment of IEC Products to satisfy your unexpected demands Make your selections from any of the Cat. Nos. printed in blue and identify your order as Your order must include: of the starter selected.. Overload Relay Code Suffix. If required, factory-installed modifications suffix code. If required, of any accessories. 3-70
Enclosed Type Sheet Metal AC Operated Product Selection Fast Shipment Program Cat. Nos. are printed in blue. Ratings (AC3, AC4) IP42 (Type 1) General Purpose IP66 (Type 3, 4, 12) Watertight, Dusttight Sheet Metal Enclosure Sheet Metal Enclosure Max kw (Lift-off Cover through 109-B110) (Hinged Cover) [A] 3 1 ➊ 3 380V/415V 115V 230V 200V 230V 460V 575V 9 4 1/3 1 2 2 5 7-1/2 109-C09A 109-C09F 12 5-1/2 1/2 2 3 3 7-1/2 10 109-C12A 109-C12F 16 7-1/2 1 3 5 5 10 15 109-C16A 109-C16F 23 11 2 3 5 7-1/2 15 15 109-C23A 109-C23F 30 15 2 5 7-1/2 10 20 25 109-C30A 109-C30F 37 18-1/2 3 5 10 10 25 30 109-C37A 109-C37F 43 22 3 7-1/2 10 15 30 30 109-C43A 109-C43F 60 30 5 10 15 20 40 50 109-C60A 109-C60F 72 37 5 15 20 25 50 60 109-C72A 109-C72F 85 45 7-1/2 15 25 30 60 60 109-C85A 109-C85F 110 55 30 40 75 100 109-B110A 3-109-B110F 3-180 90 60 60 150 150 109-B180A 3-109-B180F 3-250 132 75 100 200 250 109-B250A 3-109-B250F 3-303 160 100 100 250 300 109-B300A 3-109-B300F 3-414 220 125 150 350 400 109-B400A 3-109-B400F 3-608 315 300 250 500 600 109-B600A 3-109-B600F 3- The as listed is incomplete. Select a from the table below to complete the Example: 109-C09A becomes 109-C09AB. Common Control ➋ For 109-C Starters Separate Control (without transformer) Common Control ➋ 208-220 277 380-400 400-415 440 480 500 600 50 Hz A T N G B M 60 Hz H L A N B C 60 Hz J X D T For 109-B Starters Separate Control (without transformer) ➌ 208-220 277 380 415 440 480 500 600 50 Hz A T N I B M 60 Hz H L A G B C 60 Hz J X D F Overload Relay Code ➊ The as listed is incomplete. Select an overload relay code from page 3-87 or 3-88. ➊ For single-phase (1 ) applications, consult Allen-Bradley Sales Office for overload relay selection. ➋ When selecting a factory-installed control circuit transformer (see Modifications page 3-98), use the Common Control to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: 109-C09FB -6P will have a transformer with a 480V primary/120v secondary and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second must be added to denote the coil/transformer secondary voltage. Example: 109-C09FBJ -6P will have a transformer with a 480V primary/24v secondary and a 24V starter coil. ➌ Coils below 110V are not available for 109-B400 and 109-B600 Starters. Accessories Page 3-89 Modifications Page 3-98 Approximate Dimensions Page 3-103 and 3-106 3-71
3 Open Type Eutectic Alloy Overload Relay Open Type Eutectic Alloy Overload Relay Accepts Class 10, 20, or 30 Heater Elements Compact Design Attached to a Common Mounting Plate 109-C30NDKOV TABLE OF CONTENTS Description Page Description Page Product Selection... 3-73 Accessories.... 3-89 Approximate Dimensions...3-109 Description open-style starters use Bulletin 100 contactors and Bulletin 592 eutectic alloy overload relays on a common mounting plate. All starters include a normally open auxiliary contact as standard. Conformity to Standards: CSA 22.2 UL 508 Your order must include: of the starter selected.. Overload Relay Suffix Code. 3-72
Product Selection Open Type Eutectic Alloy Overload Relay Starters with AC Coils Starters require 3 overload heater elements. See the Industrial Control Catalog for selection tables. Ratings (AC3, AC4) Max kw Open Type 3 1 3 [A] 380V/415V 115V 230V 200V 230V 460V 575V 9 4 1/3 1 2 2 5 7-1/2 109-C09N JOV 12 5-1/2 1/2 2 3 3 7-1/2 10 109-C12N JOV 16 7-1/2 1 3 5 5 10 15 109-C16N JOV 23 11 2 3 5 7-1/2 15 15 109-C23N JOV 30 15 2 5 7-1/2 10 20 25 109-C30N KOV 37 18-1/2 3 5 10 10 25 30 109-C37N COV 43 22 3 7-1/2 10 15 30 30 109-C43N COV 60 30 5 10 15 20 40 50 109-C60N COV 72 37 5 15 20 25 50 60 109-C72N DOV 110 55 30 40 75 100 109-B110N DOV 180 90 60 60 150 150 109-B180N TP2 The as listed is incomplete. Select a from the table below to complete the Example: 109-C09N JOV becomes 109-C09NDJOV. For 109-C Starters 208 380 400 220 277 400 415 440 480 500 600 Common Control 50 Hz A T N G B M 60 Hz H L A N B C Separate Control (without transformer) 60 Hz J X D T For 109-B Starters 208 220 277 380 415 440 480 500 600 Common Control 50 Hz A T N I B M 60 Hz H L A G B C Separate Control (without transformer) 60 Hz J X D F Starters with DC Coils Starters require 3 overload heater elements. See the Industrial Control Catalog for selection tables. Ratings (AC3, AC4) Max kw Open Type 3 1 3 [A] 380V/415V 115V 230V 200V 230V 460V 575V Cat. No 9 4 1/3 1 2 2 5 7-1/2 109-C09NZ JOV 12 5-1/2 1/2 2 3 3 7-1/2 10 109-C12NZ JOV 16 7-1/2 1 3 5 5 10 15 109-C16NZ JOV 23 11 2 3 5 7-1/2 15 15 109-C23NZ JOV 30 15 2 5 7-1/2 10 20 25 109-C30NZ KOV 37 18-1/2 3 5 10 10 25 30 109-C37NZ COV 43 22 3 7-1/2 10 15 30 30 109-C43NZ COV 60 30 5 10 15 20 40 50 109-C60ND COV 72 37 5 15 20 25 50 60 109-C72ND DOV 110 55 30 40 75 100 109-B110NZ DOV 180 90 60 60 150 150 109-B180NZ TP2 The as listed is incomplete. Select a from the table below to complete the Example: 109-C09NZ JOV becomes 109-C09NZJJOV. DC Voltage 12V 24V 48V 64V 80V 115V 125V 230V 250V 109-C Starter Q J Y B E P S F T 109-B110 Starter 12 24 48 64 80 01 03 23 25 Accessories Page 3-89 Approximate Dimensions Page 3-109 3-73