Alien Crosstalk measurement limitations at low frequencies (1 MHz to ~ 10 MHz)

Similar documents
Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Data Communications Competence Center

Belden IBDN System 10GX The next level of cabling performance

Challenges for testing 10GBASE-T

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

What really changes with Category 6

Belden IBDN System 10GX Enabling Technologies

Everything you always wanted to know about HDBaseT*

Keysight Technologies Method of Implementation (MOI) for BroadR-Reach Link Segment Tests Using E5071C ENA Option TDR

Draft Baseline Proposal for CDAUI-8 Chipto-Module (C2M) Electrical Interface (NRZ)

RTPGE Prototype Channel & Alien Test Results

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

CATEGORY 6A CABLING SOLUTIONS

SYSTIMAX GigaSPEED XL Solution

SECTION TESTING OF COPPER CABLES

CATEGORY 6A CABLING SOLUTIONS

Volition TM RJ45 K5e Jacks

Data Communications Competence Center

Brian Holden Kandou Bus, S.A. IEEE GE Study Group September 2, 2013 York, United Kingdom

Agilent 87075C Multiport Test Set Product Overview

System Quality Indicators

How to Implement PoE in Your Harsh Industrial Environment

The DAC1. Introducing. Digital to Analog Converter. PRELIMINARY ANALOG DOMAIN DAC1 1 November, 2016

DESIGN!!GUIDELINES!!!!!

Sources of Error in Time Interval Measurements

Interface Practices Subcommittee SCTE STANDARD SCTE Composite Distortion Measurements (CSO & CTB)

Synthesized Clock Generator

Worst Case Alien-Near-End-Crosstalk Measurements and Analysis for IEEE 802.3bp

Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Composite Distortion Measurements (CSO & CTB)

Connect with the industry s best CAT6 and CAT5e channel solutions!

Class E A / Cat.6A Screened Coupler

OTR-3550 FREQUENCY AGILE - F.C.C. COMPATIBLE TELEVISION PROCESSOR INSTRUCTION MANUAL

Supplemental Measurements of System Background Noise in 10GBASE-T Systems

ENGINEERING COMMITTEE

Copper Cabling Troubleshooting Handbook

Category 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards.

R-1580A Microwave Downconverter. Product Brochure

1:8 CAT5 Distribution Amplifier

TransitHound Cellphone Detector User Manual Version 1.3

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

Practical considerations of accelerometer noise. Endevco technical paper 324

SECTION COMMUNICATIONS HORIZONTAL CABLING

Clause 74 FEC and MLD Interactions. Magesh Valliappan Broadcom Mark Gustlin - Cisco

Oscilloscopes for field applications

Clock Jitter Cancelation in Coherent Data Converter Testing

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

384A Adapter Installation Instructions

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

How to Speak Fiber Geek Article 4: Single-Mode Optical Fiber Geometries

Clarity Advanced Solutions6A

Planning Tool of Point to Poin Optical Communication Links

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE

Draft 100G SR4 TxVEC - TDP Update. John Petrilla: Avago Technologies February 2014

Noise Detector ND-1 Operating Manual

AMERICAN NATIONAL STANDARD

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

10GBASE-LRM Interoperability & Technical Feasibility Report

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Broadcast Television Measurements

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

Digital noise floor monitoring (DNFM)

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

STB Front Panel User s Guide

CABLE LOSS MASKING EFFECT

Duobinary Transmission over ATCA Backplanes

Extending the Reach of HDMI, DVI and CAT5 Cables Using the DS16EV5110 Cable Equalizer

Viavi ONX Ingress Mitigation and Troubleshooting Field Use Case using Ingress Expert

Calibrating attenuators using the 9640A RF Reference

Applications of FIBERPRO s Polarization Scrambler PS3000 Series

Measurements Results of GBd VCSEL Over OM3 with and without Equalization

The need for Encircled Flux, real or imaginary?

Analog Performance-based Self-Test Approaches for Mixed-Signal Circuits

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

Full Disclosure Monitoring

Vortex / VSX TM 8000 Integration

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

AN-822 APPLICATION NOTE

Transmission Strategies for 10GBase-T over CAT- 6 Copper Wiring. IEEE Meeting November 2003

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

Experiment 7: Bit Error Rate (BER) Measurement in the Noisy Channel

DA : Series of Narrowband or Wideband Distribution Amplifiers

AudioControl. Goes the Distance

Drop Passives: Splitters, Couplers and Power Inserters

Z Technology's RF NEWSLETTER DTV edition -- May 2002

Mixing in the Box A detailed look at some of the myths and legends surrounding Pro Tools' mix bus.

Automated Local Loop Test System

BER MEASUREMENT IN THE NOISY CHANNEL

AMERICAN NATIONAL STANDARD

OWNERS MANUAL LUNATEC V3 MICROPHONE PREAMPLIFIER AND A/D CONVERTER

Impact of Intermittent Faults on Nanocomputing Devices

Job Aid Server and CSS Separation Avaya S8700 Media Server

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

Modula SDI Digital Video Enclosures

Transcription:

Alien Crosstalk measurement limitations at low frequencies (1 MHz to ~ 10 MHz) Prepared for IEEE802.3an 10GBase-T task group Henriecus ( Henri or Riekus ) Koeman Fluke Networks 1 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group This presentation is to be made to the IEEE802.3an task group on 10GBase-T during the May 2005 meeting in Austin, Texas. Comments and suggestions are always appreciated! Henriecus ( Henri or Riekus ) Koeman Fluke Networks (Monday/Tuesday/Wednesday) P.O. Box 9090 6920 Seaway Boulevard Everett, WA 98206 USA Everett, WA 98203 USA Tel: +1 425-446-5399 Fax: +1 425-446-5043 E-mail: henriecus.koeman@flukenetworks.com HK Engineering Services (Thursday/Friday) 1022 C Avenue Edmonds, WA 98020 Tel: +1-425-775-2088 E-mail: henri_koeman@ieee.org Presentation to IEEE802.3an 10GBase-T 1

The key issue Due to measurement (random noise floor) limitations, the PSANEXT and PSA(EL)FEXT requirements at low frequencies cannot be verified. Possible solutions include: Starting requirements at 10 MHz instead of 1 MHz. Applying a cap (like the 62 db used for PSNEXT). Filtering the data by characterization as noise or real AXtalk. 2 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group The key issue is that as stated the PSANEXT and PSA(EL)FEXT requirements at low frequencies cannot be verified. It is felt strongly that any performance requirements must be reliably verifiable, otherwise they are meaningless. Possible solutions include: 1) Starting the requirements at a higher frequency than 1MHz. 2) Applying a cap to the maximum values (like 70 db) for PSANEXT and PSAFEXT. 3) Implementing a selection process of PP data by characterizing each as noise or a real AXtalk signal. This effectively results in a version of the 1) type of solution. Presentation to IEEE802.3an 10GBase-T 2

A limitation as proposed is actually pretty harmless. Cable and connector PSAXtalk will continue to response quite naturally at a 10 db, 15 db or 20 db slope as applicable. Therefore a failure below 10 MHz will correspond to a failure above 10 MHz with very high level of confidence. Starting PSAXtalk requirements at 10 MHz will solve numerous measurement issues with installed cabling configurations, as well as cabling component testing. Less beneficial (given the complexity of multiple PP AXtalk measurements) are the use of caps (like currently found in cabling standards: 62 db for PSNEXT). 3 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group This proposal is practically not at all harmful to the 10GBASE-T application, given that natural responses are still subject to natural slopes of 10 db, 15 or 20 db as appropriate for cable, connectors or channels. If there were a failure below 10 MHz, another failure will be found at frequencies above 10 MHz with very high level of confidence. To resolve formal measurement issues, starting the PSAXtalk requirements at 10 MHz is most helpful. One also finds regularly caps on requirements in cabling standards (like 65 db for PPNEXT and 62 db for PSNEXT). Again, it translates in practice to a higher frequency where the tests become significant. Presentation to IEEE802.3an 10GBase-T 3

Proposal The proposal is to increase the lower frequency limit of test for PS AXtalk from 1 MHz to 10 MHz. This will resolve random noise floor of measurement issues in most cases and not affect expected SNR performance in any significant manner. An alternative is to apply a 70 db cap to both PSANEXT and PSAFEXT measurements (which in effect has the effect as in the original proposal). The slides that follow are intended to back up the observations that were made to support this proposal and will be presented only if so requested. 4 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group There are significant measurement challenges as a result of the extremely sensitive signals that need to be measured. On top of that, the results from these many measurements have to be added. Presentation to IEEE802.3an 10GBase-T 4

Outline of presentation details Review of special test conditions when measuring alien crosstalk parameters in both installed cabling and component testing. Multiple measurements causes the random noise floor to accumulate. The low frequency limit becomes critical. Strategies to deal with the situation. Increase the lower frequency (1 MHz currently) to a higher frequency (10 MHz?) Applying a cap (70 db to both PSANEXT and PSAFEXT) Design strategies of classifying PP AXtalk test results as a real PP AXtalk contribution or as noise. 5 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group The detailed aspects of this presentation discuss the special test conditions when measuring alien crosstalk parameters in both installed cabling and component testing. It also identifies some strategies to deal with the challenges. Presentation to IEEE802.3an 10GBase-T 5

Random noise floor issue As a result of using many pair-to-pair alien crosstalk measurements to obtain a single power sum alien crosstalk result, the random noise floor of the PS AXtalk result declines 3 db for every doubling of the number of measurements. One PS AXtalk result for a given wire pair of a victim cable consists of 4 PP AXtalk measurements. This causes the random noise floor of a PS AXtalk measurement to be reduced by 6 db relative to the random noise floor of a PP AXtalk measurement. Doubling of the number of disturbers causes the random noise floor to decline by another 3 db. 6 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group This contribution deals with the challenge of random noise of the measurement system. This is really a major issue due to the number of measurements involved in obtaining one PS AXtalk result. Starting with a PP AXtalk noise floor, the PS AXtalk noise floor is 6 db worse (for every doubling of the number of measurements, the noise floor power increases by 3 db). Then we have to measure potentially many disturbers to a single victim. This further decreases the random noise floor of the PSAXtalk result. Presentation to IEEE802.3an 10GBase-T 6

But also. In addition to no AXtalk should be measured when there is none. The test system should not add a significant amount of AXtatlk. Whatever AXtalk is added, is named residual AXtalk. In the case of ANEXT measurements, it is residual NEXT, and can originate in adapters. Note that we are addressing test frequencies up to 500 MHz. 7 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group Of course, one should not measure any Alien Crosstalk, if there is nothing connected to the test system. The residual Alien NEXT is measured by further extending the averaging and measurement times to reduce the influence of random noise. Practically, there is a limit of what additional averaging really does, though. So some influence of random noise on the measured result remains visible. At 500 MHz, any exposed wire acts like an antenna; it does not take much to pick up signals from such antenna. Presentation to IEEE802.3an 10GBase-T 7

What practical test systems are capable of.. The example system performance shown in the following slides are about as good as one can achieve. This is not representative of routine expected performance. Many test systems have random noise floor performance that is 10 db to 15 db worse. Note what happens in those cases with the accumulated PS Alien Crosstalk floor relative to pass/fail limits. 8 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group We show in the following slides example of a level of random noise performance that is as good as one may desire. This level of performance is most often NOT achieved, and not uncommonly is 10 db to 15 db worse. You may worry about such measurement conditions. Presentation to IEEE802.3an 10GBase-T 8

An example of a single PP Random Noise Floor and Residual Alien NEXT measurement Random Noise Floor and Residual NEXT PS ANEXT measurement -40 Limit = 60 + offset - 10 log(f/100), f <= 100; Limit = 60 + offset - 15 log(f/100), f > 100 Offset = 20 db Random Noise Floor and PS Res. NEXT in db -50-60 -70-80 -90-100 -110 Limit PS Random Noise Res PS NEXT -120 1 10 100 1000 Frequency in MHz 9 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group This slide shows an example of a random noise floor and residual AXtalk for a PP ANEXT measurement. The random noise floor is almost -110 db over the 1 MHz to 100 MHz range and then declines to approx. -100 db at 500 MHz. Given that there is a trade-off between measurement time (IFBW) and noise floor, this is about as good as what one can practically obtain. As a limit the PSANEXT limit for 100 m Cat 6 cabling is shown (62 db @ 100 MHz) + 20 db. This margin is expected to decline by 6 db to get to a PSANEXT measurement for a single disturber to victim result, and further by the number of disturbers to be included in the overall result. The residual ANEXT result (which actually includes some of the effects of random noise, which are reduced by even longer measurement times for this test), shows that one has to be very careful with the shielding of the test interface connections. Presentation to IEEE802.3an 10GBase-T 9

An example PS ANEXT measurement floor as a function of number of PS NEXT measurements Limit -40 Average 1-50 Average 2 Average 4-60 Average 8 PS ANEXT in db -70-80 -90 y = 2E-05x 2 + 0.0136x - 85.96 Average 16 Average 32 Average 64 Equation 1-100 Equation 64-110 y = 2E-05x 2 + 0.0138x - 103.86-120 1 10 100 1000 Frequency in MHz Poly. (Average 1) Poly. (Average 64) 10 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group This slide shows the degradation of a random noise floor as a function of the number of measurements that is included in a PSAXtalk result. With the number of cables that may be in a cable bundle (48) in one example, one can observe that the limits at low frequencies can easily reach into the expected random noise floor. Presentation to IEEE802.3an 10GBase-T 10

Example natural frequency responses (from Koeman @ Bennett, Febr. 2005) -30-35 -40-45 Sample PSANEXT result of "as currently installed cat 6 cabling" (victim channel #12, 47 disturbers) PSANEXT in db -50-55 -60-65 -70-75 -80 1 10 100 1000 Frequency in MHz Limit WP 12 WP 36 WP 45 WP 78 11 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group We claim that we really should not worry too much about passing limits at low frequencies. Both alien NEXT and alien (EL)FEXT exhibit behavior that is well predictable, we can therefore assuming with high confidence that a failure at high frequencies will cause the same at low frequencies and vice versa. In the example shown, the link was relatively short and therefore the performance relative to the limit line came out better than at higher frequencies; again this can be predicted from the length dependency of alien NEXT. Presentation to IEEE802.3an 10GBase-T 11

Example natural frequency responses (from Koeman @ Bennett, Febr. 2005) Sample PSAELFEXT result of "as currently installed cat 6 cabling" (victim channel #12, 47 disturbers) -15-25 PSAELFEXT in db -35-45 -55 Limit WP 12 WP 36 WP 45 WP 78-65 -75 1 10 100 1000 Frequency in MHz 12 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group Alien ELFEXT is extremely well behaved and closely approaches a 20 db/decade slope. Therefore very likely a fail condition at low frequencies will cause a fail condition at high frequencies as well. Presentation to IEEE802.3an 10GBase-T 12

Other strategies to reduce the impact of random noise Establish a level of significance. If a measured result represents less AXtalk than this level, it is not included in the measured data (it is considered really noise ). If a measured result represents more AXtalk than this level, it is included in the measured data (it is considered truly AXtalk). The impact of this strategy is being tested to determine whether the outcome is affected by this level of significance. It is being proposed for component testing of AXtalk, specifically connecting hardware, where the AXtalk levels are at least 10 db tighter than those for channels. An example on PSANEXT for installed cabling follows. 13 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group Within the cabling standards committees there are discussions on establishing significance limits for alien crosstalk tests, and especially for cabling components where the requirements are extremely tight and require the measurement of extremely sensitive signals. If a datapoint in the frequency response exceeds the threshold (meaning to say that the signal amplitude is higher than the limit), it is included in the overall determination of PSAXtalk. If that datapoint does not exceed that threshold it is NOT included. The author has just evaluated what the impact of such operation could be on the results. More evaluation is needed. Presentation to IEEE802.3an 10GBase-T 13

Example of level of significance Random Noise Floor and Residual NEXT PS ANEXT measurement -40 Limit = 60 + offset - 10 log(f/100), f <= 100; Limit = 60 + offset - 15 log(f/100), f > 100 Offset = 20 db Random Noise Floor and PS Res. NEXT in db -50-60 -70-80 -90-100 -110 Limit PS Random Noise Res PS NEXT Significance -120 1 10 100 1000 Frequency in MHz 14 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group An example level of significance is shown in this slide. This level is being considered for the testing of alien NEXT in connecting hardware. Presentation to IEEE802.3an 10GBase-T 14

Original PSANEXT result PSANEXT of Currently Installed Cat 6 cabling (no length correction, no significance limits applied) 90 80 PSANEXT in db 70 60 50 Limit 12 36 45 78 Limit + 1 db Avg. 40 30 1 10 100 1000 Frequency in MHz 15 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group This data represents the PSANEXT of a victim channel in a 48 bundle at Lawrence Berkeley National Laboratories that was reported to the IEEE-802.3an Task Group in March 2005. No post-processing was implemented. Presentation to IEEE802.3an 10GBase-T 15

90 Processed PSANEXT result with significance level applied PSANEXT of Currently Installed Cat 6 cabling (no length correction, significance limits applied) 80 PSANEXT in db 70 60 50 WP 12 WP 36 WP 45 WP 78 Ave 40 30 1 10 100 1000 Frequency in MHz 16 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group This is the data that remains after post-processing using the significance level approach. The green trace is wire pair 12. The red trace is wire pair 36. The blue trace is wire pair 45, The brown trace is wire pair 78. The black trace is the average of all 4 wire pair trace. Note that defacto all data below between 1 MHz and several MHz (between 2 MHz and 3 MHz) gets wiped out and in fact no testing at all occurs in that frequency band. Presentation to IEEE802.3an 10GBase-T 16

Impact of level of significance Impact of significance levels on reported PSANEXT, Cat 6 cabling, 48 cables 10 9 8 Difference in db 7 6 5 4 3 2 1 0 1 10 100 1000 Frequency in MHz WP 12 WP 36 WP 45 WP 78 Ave Diff 17 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group The difference of the two results at data points that do exist show the distortion that occurs from this. Note that there is some error (reporting of optimistic results) occurs up to approx. 30 MHz as a result. Presentation to IEEE802.3an 10GBase-T 17

Conclusion from the example Assuming the use of a significance level as being discussed in cabling groups: The data is filtered out to frequencies below 10 MHz and 15 MHz. It would be more straightforward to specify that pass/fail limits below 10 MHz should not apply. 18 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group The alternative to filtering out data is to start applying pass/fail limits at 10 MHz and not implement any filtering at all. This would prevent introducing distortion of measured results. Presentation to IEEE802.3an 10GBase-T 18

Conclusions To formally specify 10 MHz as a starting point for pass/fail testing of Alien Crosstalk would help the formal procedures for testing both installed cabling and cabling components tremendously, particular in regards to random noise floor properties of test equipment. Practically, the natural frequency responses of Alien Crosstalk assure to a high level of confidence that if there were a failure at low frequencies, a failure would exist at frequencies above 10 MHz as well. One may assume that the expected performance extends down to 1 MHz. 19 Alien crosstalk Henriecus Koeman May 2005 Presentation to IEEE802.3an 10GBase-T task group The IEEE 802.3an Task Group, which is the responsible party for specifying performance for the physical layer, is key to consideration of this matter. By changing the starting frequency of testing, a significant issue with cabling standards committees would be resolved, without a practical degradation of practical performance. Faced with serious random noise floor challenges, if such action is not taken, standards committees will need to implement some kind of filtering of data, which in affect accomplishes the same thing, but also introduces errors in reported data. Presentation to IEEE802.3an 10GBase-T 19