Ø 1000 * 588 mm 50 kg

Similar documents
GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

Detailed Specifications & Technical Data

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Revision No. 4 Page No. Page 1 of 7

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

LD Series High Performance Loose Tube Fiberoptic Cables

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

SPECIFICATION. Optical Fiber Cable

Product Catalogue. Fibre Optic Cable

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

OPTICAL FIBRE CABLE NETWORK 2004/1

Empowering businesses through innovative network solutions.

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Micro duct Cable with HDPE Sheath for Installation by Blowing

TECHNICAL SPECIFICATION

Mining and Petrochemical Fiber Optic Cables

1. General. 1. Scope. 2. Quality Assurance

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

FREEDM Loose Tube Interlocking Armored Cables

Number of Fiber 12 Core 24 Core 48 Core. Part Number

Number of Fiber 6 Core 12 Core. Part Number

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Number of Fiber 6 Core 12 Core 24 Core 48 Core

TENDER SUMMARY. Tender Title:

Industry solutions: Broadcast

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

HITRONIC Optical Transmission Cable

FIBRE OPTIC CABLE SOLUTIONS

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

SOLO ADSS Short-Span Cables, Fibers

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

OPTICAL CABLE FIBER-LAN INDOOR

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

We design, build, and manage web-scale networks for the needs of tomorrow. System Integration SERVICES

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

Table of Contents. Open Matrix System (OMS) 1-2

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

The World Of Professional Fiber Optics. safe flexible reliable

AFL Telecommunications

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2

Mini-breakout & Mini-bundle cable. Riser cabling solution

Material Description Quantity UOM

Cables for robot applications

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

HERA RETICULATION FIBRE CABLE PRODUCT REQUIREMENTS

Triax TechInfo. Installing and pulling Fibre Optic cables

Content. 1.4 Fiber Cable Assembly

OPTICAL FIBER CABLES FTTH. SPLITTER. ACCESSORY

INDUSTRY SOLUTIONS: MINING

Instrumentation & copper telecom cables

A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

Michigan State University Construction Standards EXTERIOR FIBER OPTIC CABLE SYSTEM PAGE

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

FIBER OPTICS FIBER OPTIC CABLE FOR VOICE AND DATA TRANSMISSION

Cable installation guidelines

Table of Contents. Specifying AFL Premise Optical Cables Outdoor. Enterprise. Interconnect. MicroCore. Indoor.

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

40G SWDM4 MSA Technical Specifications Optical Specifications

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

Draka Comteq Presents: The MaxCap multimode Fibre for 10 Gb/s Applications

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

Siam Pacific Electric Wire & Cable Co., Ltd.

Table of Contents. Teldor Cables and Systems Ltd.

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

Welcome to the latest edition of the Telstra Cable Guide.

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SECTION 4 TABLE OF CONTENTS

40G SWDM4 MSA Technical Specifications Optical Specifications

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

Fiber Optic Cabling Infrastructure Offering

OPTICAL FIBER CABLES FTTH. SPLITTER. ACCESSORY. The best technology and customer satisfaction

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content

Recommended Changes to Optical PMD Proposal

for FOSTEC INC. 1/ 15

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

Transcription:

GOCN Central Loose Tube Cables Outdoor Corrugated Steel Tape Armor (CST) A-DQ(ZN)(SR)2Y Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 4 6 8 12 16 24 62.5/125-OM1 GOCN104 GOCN106 GOCN108 GOCN112 GOCN116 GOCN124 -OM2 BW /1200 GOCN204 GOCN206 GOCN208 GOCN212 GOCN216 GOCN224 -OM3 GOCN304 GOCN306 GOCN308 GOCN312 GOCN316 GOCN324 -OM2e GOCN404 GOCN406 GOCN408 GOCN412 GOCN416 GOCN424 -OM2 BW 500/500 GOCN504 GOCN506 GOCN508 GOCN512 GOCN516 GOCN524 -OM4 GOCN604 GOCN606 GOCN608 GOCN612 GOCN616 GOCN624 9/125 ITU G.655 GOCN704 GOCN706 GOCN708 GOCN712 GOCN716 GOCN724 9/125 ITU G.652D GOCN804 GOCN806 GOCN808 GOCN812 GOCN816 GOCN824 Std. plywood reel (non-returnable) Std. delivery length Ø 1000 * 588 mm 50 kg 2100 ± 100m Applications For outdoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling.. For outdoor use in networks for industrial, telecom, cable TV and/or broadcast. Suitable for direct burial. Easy to install in ducts, tunnels and trenches. Features & Benefits A simple cable construction and consequently more cost-effective up to 24 fibres then multi-tube cables. High mechanical and full rodent protection provided by corrugated steel tape (CST) armour. Predicted lifetime > 30 years.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794) 1. Primary coated optical fibres: Ø 250 ± 15 um. 2. Central tube, jelly filled (non-dripping and silicon-free) with up to 24 fibres. Individually colour coded optical fibres: 1 12: red natural yellow blue green violet brown black orange turquoise pink and white. 13 24: red natural yellow blue green violet brown grey orange turquoise pink and white with rings. 3. Water Swellable yarns as strength members and for the longitudinal watertightness. 4. Corrugated Steel Tape Armouring (CST): helical longitudinally applied steel tape (0.155 mm). 5. Black UV resistant PE outer jacket. Identification: BELDEN OFC cable type number x type of fibre + date-, meter- and P/N marking. Mechanical Data No. of fibres Max. 24 Ø Central tube (mm) 3.3 nom./max. (mm) 9.0/9.3 Energy of flame (kj/m) 1774 Weight (kg/km) 80 2

Optical Characteristics Characteristics (cabled) Single-Mode Matched-Cladded optical fibres according to ITU. European Partnumber Coding, Position 5 Fibre-Type Mode-Field /CladdingDi ameter (um) Wavelength Attenuation average/ max. (db/km) Dispersion (ps/(nm-km) PMD (ps/km) Cable Cut-off Wave-length 8 9/125 G.652D 9.2 ± 0.4 125 ± 0.7 1310 1 0.32 / 0.40 0.21 / 0.30 3.5 18 0.2 1260 7 9/125 G.655 8.4 ± 0.6 1 0.25 / 0.30 3.5 8.5 < 0.1 A 1260 Note A- Link design value Characteristics (cabled) Multi-Mode Graded-Index optical fibres according to IEC 60793 European Partnumber Coding, Position 5 Fibre-Type Mode-Field Diameter (um) Wavelength Attenuation average/ max. (db/km) Bandwidth (MHzkm) Ethernet Performance (m) 1 GBE 10 GBE Num. Apert. (µm) Refr. Index 1 62.5/125 OM1 62.5 ± 2.5 2.7 / 3.2 0.6 / 1.1 200 275 33 0.275 ± 1.495 1.490 5 OM2 2.4 / 3.0 0.7 / 1.0 82 1.481 1.476 2 OM2 2.3 / 2.8 0.6 / 0.9 1200 82 1.481 1.476 4 OM2e 50 ± 2,5 2,3 / 2,8 0,6 / 0,9 1200 750 2000 110 na 1,481 1,476 3 OM3 2.5 / 3.0 0.5 / 1.0 1500 900 300 1.482 1.477 6 OM4 2.5 / 3.0 0.5 / 1.0 0 900 1.482 1.477 A test report (attenuation) is supplied with each delivery. 3

Mechanical, Physical and/or Environmental Characteristics Requirements Temperature range according to IEC 60794-1-2-F1 Transport/storage Installation Operation -30 to + 70 C -5 to + 50 C -30 to + 70 C Pulling tension according to IEC 60794-1-2-E1 Long term Short term 800 N 1 N Bending radii for fibres and tubes Installation/operation Watertightness according to IEC 60794-1-2-F5 Crush resistance according to IEC 60794-1-2-E3 >25 mm Yes 30 KN/m Bending radii cable Static according to IEC 60794-1-2-E11 Dynamic according to IEC 60794-1-2-E6 10 x ø 20 x ø Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standards. To ease insertion into tubes by means of compressed air or pulling wire, certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. If a cable needs to be fastened, constrictions > 0.3 mm must be prevented. The jelly filling inside the tubes can be removed using a tissue soaked in turpentine. It is advisable to cap the cable-ends during storage. Options Cables for outdoor use only. Non-standard cable constructions, colours, details and/or additional information regarding specifications are available on request. 4

Revision Rev. Description Date Init. Date: 23/11/2010 Page 1 of 1 Part Number: Orig.: SN Review: GOCN 5