Durata. Defibrillation Lead

Similar documents
3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

Flygt Submersible Motor Cables

3M Cold Shrink Foldback Splice Jacket Kit

Scotch Heavy Duty Vinyl Electrical Tape 22

Spine Cable System. Implants and instruments for use when stabilizing and reconstructing spinal structures.

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

MX DVI-D 24+1 PIN MALE TO HDMI 19 PIN MALE CABLE. MX-3247

PRELIMINARY. Pro One-Cell Fixed. ArcSystem Series

Cables. Tonearm cables. Interconnect cables. Speaker cables

PL Series. Plastic Push Pull Interconnects

CARLITE grain orien TEd ELECTRICAL STEELS

3M Cold Shrink Splice Kit QS-III 5515A

Quick Term II Silicone Rubber Termination Kits for Shielded Cables Instruction Sheet

System 500. Non-fire-rated, mineral insulated copper sheathed wiring cable

3M Cold Shrink Splice Kit QS-III 5416A

3M Cold Shrink Splice Kit QS-III 5514A

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

8D with High Frequency Coaxial Contact

TA0311 TECHNICAL ARTICLE High Temperature Electronics 1 Introduction 2 Why the need for high-temperature semiconductors?

TNC Connectors. RF Coax Connectors. Product Facts

IndyGo Facility Upgrades Project 35671EE

Multi-Touch Resistive Touch Screens

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Automotive and Aerospace Solutions Division. Spec d to protect.

Fiber Optics Redefined

Processing Specification MiniBridge IDC

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

SPECIFICATION. Spec No : VSS-1402-CS603B

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Continuous Flex Data Cable

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

VITALink Taped Splice Straight Through Crimp

Modular Data Plug RJ45 Cat5e. Material, Color, and Finish. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Cold Shrink Straight Joint

Installation Guide VL-MV10. Model No.

PRESS RELEASE NEW ISOTEK MAINS CABLES: NOW WITH DEEP CRYOGENIC TREATMENT!

The Absolute Sound High-End Audio Buyer s Guide 2017

THE GLOBAL LEADER IN SCREENING TECHNOLOGY

TRAN-COR H. grain ORIENTED ELECTRICAL STEELS. Applications Potential. a significant increase in core loss.

Micro-Machined Silicon Transducers

Instructions. P MHz 1X/10X Passive Probe

Cold Shrink Silicone Rubber Termination QT-II

APPLICATION NOTE. Practical Tips for Using Metalic Time Domain Reflectometers (The EZ Way) What is a Time Domain Reflectometer?

pot bearings Innovative Solutions

PanelView 1400e CRT Maintenance

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

artisan time coherent, phase coherent, resonance coherent 5 driver, 3 way reference monitors

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

Cables. Tonearm cables. Interconnect cables. Speaker cables

Trends and Challenges of HV Cable Systems

Tipping the balancetotal Cost of Ownership

Medium Voltage 12/20 (24)kV NF C cable system. Xavier Brosse Luanda May 2009

Small Circular Connector. JN1W / JN2W Series

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz)

Safe, Accurate, and Repeatable

Stock Products. Over 10,000 Sensors In-Stock Ready to Ship!

Jul03 Rev C EC

(12) United States Patent (10) Patent No.: US 7,027,852 B2

Images for life. Nexxis for video integration in the operating room

BRIGHT BRIGHTER BRIGHTEST ONE ILLUMINATOR DESIGN THREE LIGHT SOURCES. featuring the EvenVue Reflector System

Amphenol. Circular Connector Series. easier & quicker. by Amphenol. Amphenol-Tuchel Electronics GmbH

Continuous High-Flex Cable for Automated Systems

KUZMA 4POINT TONEARM

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS (440)

Screen Technology. Catalog. Innovative Screen Cloth. Repairable Plate Screen. Patented Pyramid Screen API RP 13C (ISO 13501) COMPLIANT SCREENS

Content. Solutions for MRI. Medical electronic Connectors

Type "N" Connectors. Type "N" Interface Dimensions

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

Bartels Micropumps. ( ) Rev. 2.8

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK

Instrukcja montażu. FLEX LED Neon Instalacja

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Medical Application Information

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

MaxiBridge mm Connectors. Ed Full-scale MaxiBridge 8 Pins Catalog E

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

Micro-DCI 53ML5100 Manual Loader

W-Series. Switch. Fully sealed and submersible IP68 protection including below the panel Tri-seal design Connector with twin locking tabs

Laminar Design Screen Basket

18 (300mm) ultra-high excursion cone transducer, 4" (100mm) voice coil, ferrite magnet

CUSSOU504A. Microphones. Week Two

PROGRAMMING GUIDE. Accurate Targeting. Precise Control.

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

NewScope-7A Operating Manual

LEGEND POWER SYSTEMS

3 SLiC Aerial Closure with Rubber End Seal

Performance Broadband Innovation

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Henkel Installation Handbook LINEGUARD 2001

Chris: Yeah, I wasn t able to go up a flight of stairs, wasn t able to lay down flat and wasn t able to breathe.

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

Scotchal Translucent Graphic Film Series 2630

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content

LED MODULES READYLINE DL

Transcription:

Durata Defibrillation Lead

What the data has to say about Durata ICD leads. We share a mutual goal to reduce risk and improve patient outcomes by advancing the practice of medicine. Now allow us to share the data on Durata ICD lead technology. Together, let s take a moment and focus on the facts that define excellence in lead performance. To discuss the numbers in detail. And examine the evidence that adds clarity to the larger conversation. Moving forward with confidence. It s what happens when everyone speaks the same language.

Reduction in externalized conductor failure rates. 1 CLOSER To CeNTER The decreased inner coil and stylet lumen diameter allow the conductors to be more closely configured to the center of the lead body. This reduces tension on the conductors and, therefore, the risk of externalized conductors. 2 Optim InsulAtion Credit for the 50% increase in wall thickness goes to advanced Optim insulation. Exclusive to St. Jude Medical leads and at least 50 times more abrasion-resistant than silicone, 1 Optim insulation blends the biostability and flexibility of silicone with the durability, lubricity and abrasion resistance of polyurethane. Durata OPtim 7F 3 7F Diameter Durata is the world s only 7F ICD lead technology engineered to avoid venous occlusion in patients with multi-lead systems or patients with smaller vasculature.

More innovation. Zero comparison. Over 85% of Durata ICD lead components are newly designed. Upgraded components Lead Body Insulation Thickness Durata lead 50% increase in insulation thickness Lead Body Insulation Material Optim insulation (with greater than 50 times the abrasion resistance of silicone) over the silicone 1 Inner coil Design Single Coil Lead Body Design Distal Cable Termination at Electrodes Shock Coils Connectors Cable Conductors Distal tip RV Shock Coil Smaller inner lumen positions cables closer to central axis, reducing shear stress and cable tension Additional conductor pair added to more evenly distribute force on cables. Maintains consistency with dual coil design Process technology change allowing cables to reside in a neutral stress state Flat wire shock coils, backfilled with silicone, minimize internal cable pressure against silicone insulation under shock coils, reducing risk of internal shorts DF4 connector added. Full Optim insulation also added to IS1, DF1 and DF4 connector tails Low Titanium (LT) grade material reduces impurities, providing higher fatigue strength Atraumatic soft silicone rubber tip to reduce tip pressure Curved slightly during manufacturing to create better buckle point Legacy Components Use of PTFE Use of ETFE Insulation tubing over inner coil for helix performance and insulation integrity Insulation coating over each cable for insulation integrity

600,000 Durata ICD leads: Better performance from the inside out. >500,000 500,000 Relative to first-generation 8F silicone ICD options, Durata 7F ICD leads with Optim insulation demonstrate 100% reduction in externalized conductor failure rates. The data also shows a 96% decrease in all-cause abrasion failures as well as a 99% reduction in internal shorts between the cable and shock coil. Finally, lead-to-can abrasions have diminished by 97%. 2 400,000 THEN product performance report data 1 riata lead Durata lead 97% Reduction in ALL-CAUSE ABRASION 3 92% Reduction in ALL-CAUSE Mechanical Failures 4 NOW active registry data at 5 years 5 99.9% Freedom from ALL-CAUSE ABRASION 6 99.6% Freedom from ALL-CAUSE MECHANICAL FAILURES 6 Cycles to Failure per unit (Mil) of Insulation 1 Optim Insulation 9,976 Silicone 300,000 200,000 100,000 0

All Cause Internal Shorts (Reported cases and percentage) 2 0.079% 0.003% 0% 0.010% 0.020% 0.030% 0.040% 0.050% 0.060% 0.070% 0.080% 0.090% 0.100% Internal Shorts Under Shock Coil (Reported cases and percentage) 2 0.074% 0.001% 0% 0.010% 0.020% 0.030% 0.040% 0.050% 0.060% 0.070% 0.080% 0.090% 0.100% Lead-to-Can Abrasion 2 0.36% 0.01% 0%.2% 0.4% 0.6% 0.8% 1.0% Legend: Riata 8F Silicone Leads (156,308 Sold worldwide) Durata Leads (276,021 Sold worldwide) ICD lead technology cannot be insulated from change. The fact is, the Durata ICD lead is a significant step forward from earlier generation silicone-insulated options. Today, over 85% of Durata ICD lead components are newly designed and have resulted in improvements in abrasion resistance, elimination of externalized conductors and reductions in shorting under the shocking coils small but significant configuration changes that deliver dependable results and long-term durability.

Patients over 5 years An ICD lead study without equal. Over five years ago, we set out to actively monitor the post-market performance of all St. Jude Medical Optim -insulated leads. To ensure the most robust, long-term data and greatest amount of immediate transparency, thousands of patients were enrolled in the registries creating far and away the largest data-set of its kind. The results illustrate the level of precision and understanding that more than 27,000 patient-years of surveillance has to offer.

With more than 10,000 leads significantly more than that of the next closest competitive ICD lead study enrolled in post-market registries spanning more than a 60-month period, Optim ICD leads continue to show outstanding performance. Registries and Studies Launched/Follow-up Optim Leads Implanted Number of Sites OPTIMUM August 2006 > 5½ yrs 5,997 Durata and Riata ST Optim 224 SCORE September 2007 > 4½ yrs 3,458 Durata and Riata ST Optim 58 SJ4 PAS June 2009 >2½ yrs 1,743 Durata DF4 58 TOTALS 10,950 292

100% 99.59% 98.71% 98.06% Lead Survival Probability 90% 80% Riata ST Optim/Durata Sprint Quattro secure Endotak Reliance G 0 1 2 3 4 5 6 7 8 Medtronic System Longevity Study (SLS) Data: 2011-2 Medtronic CRDM Product Performance Report St. Jude Medical SCORE registry, OPTIMUM registry and SJ4 Post Approval Study Boston Scientific Longitudinal Surveillance Registry Years from Implant We don t manufacture claims. We equip you with facts. Take a closer look at how other prospective, active ICD lead registries measure up. The data on Durata ICD leads is clear. The overall survivability of St. Jude Medical ICD leads with Optim insulation compares favorably to Medtronic and Boston Scientific ICD leads. Dive deeper into the discussion at www.fluentinfact.com.

References 1 Jenney C, Tan J, Karicherla A, Burke J, Helland J. A New Insulation Material for Cardiac Leads with Potential for Improved Performance, HRS 2005, Heart Rhythm, 2, S318-S319 (2005). 2 Based on complaints and returns through February 29, 2012. 3 Based on returns and complaints analysis through February 2012. 4 Based on returns and complaints analysis through December 2011, as reported in 2012-1 PPR. 5 While passive complaint reporting such as those in the product performance report (PPR) may underestimate the true failure rate associated with any given failure mechanisms, using returns and complaints analysis from the PPR helps to compare performance across lead families from one company. In contrast, data from actively monitored registries gathered by dedicated field monitoring represents the true commercial experience. 6 Data collected from SCORE, OPTIMUM, and SJ4 registries through December 2011. Global Headquarters One St. Jude Medical Drive St. Paul, Minnesota 55117 USA +1 651 756 2000 +1 651 756 3301 Fax Atrial Fibrillation Division One St. Jude Medical Drive St. Paul, Minnesota 55117 USA +1 651 756 2000 +1 651 756 3301 Fax U.S. Division 6300 Bee Cave Road Building Two, Suite 100 Austin, Texas 78746 USA +1 512 732 7400 +1 512 732 2418 Fax St. Jude Medical Coordination Center BVBA The Corporate Village Avenue Da Vinci Iaan, 11 - Box F1 B-1935 - Zaventem Belgium +32 2 774 68 11 +32 2 772 83 84 Fax St. Jude Medical Brasil, Ltda. Rua Frei, Caneca 1380-9 A-CJ91/92 Sao Paulo - SP - Brasil CEP 01307-002 +55 11 5080 5400 +55 11 5080 5423 Fax St. Jude Medical (Hong Kong) Limited Suite 1608, 16/F Exchange Tower 33 Wang Chiu Road Kowloon Bay, Kowloon Hong Kong SAR +852 2996 7688 +852 2956 0622 Fax Rx Only Brief Summary: Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use. Riata, Durata, ST. JUDE MEDICAL, the nine-squares symbol and MORE CONTROL. LESS RISK. are registered and unregistered trademarks and service marks of St. Jude Medical, Inc. and its related companies. 2012 St. Jude Medical. All rights reserved. Item No: N01131