ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Similar documents
ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

BE3-GPR GENERATOR PROTECTIVE RELAY

www. ElectricalPartManuals. com l Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

CLASS 300 EQUIPMENT BE3-25A AUTO-SYNCHRONIZER (Single Phase)

www. ElectricalPartManuals. com l Basler Electric VOLTAGE REGULATOR FEATURES: CLASS 300 EQUIPMENT AVC63 4 FEATURES AND APPLICATIONS

MILLITARY SPECIFICATION SHEET

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Magnecraft Power Relays

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Type MG-6 Auxiliary Relay Class 1E

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV.

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Process Transmitter RMA 422

EA350. Generator Automatic Voltage Regulator Operation Manual

Instruction Manual Model # Block Upconverter

Solid-State Digital Timer

HS-509 VIBRATION TRIP MODULE

ALLEN BRADLEY TIMING RELAY

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Type Contact form Model

Bulletin 190 IEC Modular Starter System

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Multifunction Digital Timer

Instruction Manual Model BlockUpconverter

PRINCIPLES AND APPLICATIONS

02/11/2015

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

MODEL PA II-R (1995-MSRP $549.00)

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

multi-function meters

GR circuit breaker - hydraulic magnetic, Datasheet

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Model /29S RF Splitter

Process transmitter RMA422

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

COHERENCE ONE PREAMPLIFIER

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Directional Couplers and Splitters

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Definite Purpose Contactors

Magnetic and Hydraulic-Magnetic Circuit Breaker

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Intertie Protection M 3520

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Series CT7N Bimetallic Overload Relays

EG4015. Digital Generator Governor Controller User Manual

AS09..S 3-pole Contactors - Spring Terminals

EVC300i. Generator Automatic Voltage Regulator Operation Manual

GR circuit breaker - hydraulic magnetic, Datasheet

EVC600i. Generator Automatic Voltage Regulator Operation Manual

Noise Detector ND-1 Operating Manual

Generator protection relay

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION SECTION 16901

Ordering details. Approval. Classification

clipping; yellow LED lights when limiting action occurs. Input Section Features

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

DPLC-45. Teleprotection Channel

LoopBack Relay. SGLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002

XC-77 (EIA), XC-77CE (CCIR)

Type: DILM12 10(24VDC) Article No.:

1 Power Protection and Conditioning

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Photoelectrics Through-beam Type PA18C.T..., DC

RMX-44 & RMX-62 MIXING MATRIX. Installation & Operation Manual

Standard RS232 RS ma

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

SYNTHESIZED COMMUNICATION CONVERTERS

SCALE & WEIGHT DISPLAYS

SPECIFICATION ESD FSP500-80MPD. Released Date:2015/07/27-14:41:38

ODW-621. RS-232 Point-to-point applications

Contactors and Contactor Assemblies

MAW218D7. User s manual. Pol.Ind.Norte-Perpinyà, TERRASSA (Barcelona-SPAIN)

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

AF-300 E11 Adjustable Frequency Drive

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Model IQ4-PC User Manual Revision Date:

Please take a few minutes to read this manual so that you will better understand the featues and capabilities of your MF80. MF80 Owner s Manual 1

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

MAP110 AC-DC Series Data Sheet

Transcription:

BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADDITIONAL INFORMATION INSTRUCTION MANUAL ADVANTAGES Helps avoid cascading capacitor failures. Sensing circuit rejects harmonics and noise to achieve higher sensitivity to 50/60 Hz neutral voltage. Includes an early warning alarm output on minor unbalances such as a blown fuse. Can be set to trip when voltage across any capacitor exceeds 110% of nominal. Request publication 9279400990 FEATURES Page 2 APPLICATION Page 2 FUNCTIONAL DESCRIPTION Pages 3-4 SPECIFICATIONS Pages 4-5 ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA P. O. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE 618-654-2341 FAX 618-654-2351 UHF-2 9-94

FEATURES Response to harmonics is only one-hundredth of 50/60 Hz response. Pickups may be set down to 1% of full scale input voltage. Available with either inverse or definite timing characteristics. Low burden - 2VA at nominal input. Available for nominal inputs of 120 or 240 Vac. Alarm and trip outputs. Interference rejection to RFI, SWC and Fast Transient. APPLICATION The BE1-59NC relay is used for alarming or minor capacitor bank imbalances (such as those caused by a fuse blowing) and for tripping before the imbalance threatens cascading capacitor failures. The relay is connected to sense the neutral voltage as shown in Figure 1. The relay may be set to pickup within one percent of a nominal 120 or 240 Vac input. Such sensitive settings would be used for alarming. Higher pickup values are used for tripping, and should be made to trip before the voltage across a parallel section of the bank reaches 110% of nominal rating. The settings for a single blown fuse as used for alarming and the number of uses that must be blown on a parallel section to reach 110% of nominal voltage for tripping must be calculated for each capacitor bank configuration. There are many configurations, of which Figure 1 is only one example. Figure 1 - Three Phase Bank 2

FUNCTIONAL DESCRIPTION BE1-59NC relays are solid state relays requiring an external power supply source (AC or DC). The block diagram shown in Figure 2 illustrates the various functions in the relay. Figure 2 - Functional Block Diagram Capacitor neutral voltage is dropped to a full scale level of 120 or 240 volts by using a transformer connected to the capacitor bank neutral. The full scale voltage corresponds to the phase-to-neutral voltage divided by the transformer ratio. The relay presents a negligible load on the transformer with only 2 VA burden. The isolation transformer within the relay (T 1 ) drops the voltage level for electronic signal processing. Two signals are split off T 1. One is for the alarm section, and one is for the trip section. They are identical except that different timing characteristics may be used in each section. The overvoltage comparators are used to compare the input with front panel pickup settings. When the input is greater than the settings, the overvoltage pickup indicators illuminate and timing begins. 3

Voltage controlled oscillators (VCO) are used in conjunction with clocks and counters to provide the timing characteristics (Inverse or Definite) desired for each section. The characteristics desired are specified by the relay style number as given on page 6. Overvoltage outputs OV#1 and OV#2 may be either an overvoltage alarm or overvoltage trip. Both are equipped with targets which may be operated by trip current or internal circuitry. This is a style chart selection. Auxiliary relays may also be selected when completing the style chart. A rear view of the relay showing terminal blocks and internal circuits for a unit with two SPDT auxiliary output relays is shown in Figure 3. FUNCTIONAL DESCRIPTION (continued) Figure 3 - BE1-59NC With 2 AUX Relays SPECIFICATIONS INPUT RANGES AND PICKUP LEVELS Input Range Pickup 120 Vac, 60 Hz 1-20 V 120 Vac, 60 Hz 10-50 V 240 Vac, 60 Hz 2-40 V 240 Vac, 60 Hz 20-100 V Input ranges for 50 Hz models are 100 V and 200 V. HARMONIC REJECTION Third harmonic rejection is 40 db minimum. BURDEN TIMING CHARACTERISTICS Inverse: See Instruction Manual for curve. Two thumbwheels provide time dial settings of 00 to 99 in 01 increments. Setting 00 provides instantaneous operation. Definite: This is a fixed time independent of input current. Three thumbwheels provide time dial settings of 00.1 to 99.9 seconds in 0.1 second increments. Setting 0.00 provides instantaneous operation. Time dial settings correspond to actual time in seconds. Timing Accuracy: ±5% or 25ms, whichever is greater. 2 VA maximum at nominal input. 4

SPECIFICATIONS (continued) POWER SUPPLY OPERATING TEMPERATURE Type per Style Chart Nominal Input Voltage Input Voltage Range Burden at Nominal -40 C (-40 F) to +70 C (+158 F). STORAGE TEMPERATURE J 125 Vdc 62 to 150 Vdc 7.5 W 120 Vac 90 to 132 Vac 15.0 W K 48 Vdc 24 to 60 Vdc 7.0 W L 24 Vdc 14 to 32 Vdc 7.5 W Y 48 Vdc/ 24 to 60 Vdc 7.0 W 125 Vdc Selectable 62 to 150 Vdc 7.5 W Z 250 Vdc 140 to 280 Vdc 12.0 W OUTPUT CONTACTS 230 Vac 190 to 270 Vac 33.5 VA Resistive: Make and carry 30 A for 0.2 seconds, carry 3 A continuously and break 0.3 A at 125/250 Vdc. Inductive: Same as resistive, with L/R up to 0.04. TARGETS -65 C (-85 F) to +100 C (+212 F). SHOCK In standard tests, the relay has withstood 15 g in each of three mutually perpendicular planes without structural damage or degradation of performance. VIBRATION In standard tests, the relay has withstood 2 g in each of three mutually perpendicular planes, swept over the range of 10 to 500 Hz for a total of six sweeps, 15 minutes each sweep, without structural damage or degradation of performance. WEIGHT 13.6 pounds maximum. CASE SIZE S1. Magnetically latched, manually reset on overvoltage outputs #1 and #2. Target coils are in series with the output contacts and require a minimum of 0.2 amperes to operate. Target coil resistance is 0.1 ohms. ISOLATION 1500 Vac at 60 Hertz for one minute in accordance with IEC 255-5 and ANSI/IEEE C37.90-1989 (Dielectric Test). RADIO FREQUENCY INTERFERENCE (RFI) Field tested using a five watt, hand-held transceiver operating at random frequencies centered around 144 MHz and 440 MHz, with the antenna located six inches from the relay in both horizontal and vertical planes. SURGE WITHSTAND CAPABILITY Qualified to ANSI/IEEE C37.90.1-1989 Standard Surge Withstand Capability (SWC) Tests for Protective Relays and Relay Systems. 5

ORDERING INFORMATION HOW TO ORDER: Designate the model number followed by the complete Style Number. BE1-59NC Style Number Complete the Style Number by selecting one feature from each column of the Style Number Identification Chart and entering its designation letter or number into the appropriate square. (Two squares are used to indicate time delay characteristics.) All squares must be completed. STANDARD ACCESSORIES: The following accessories are available for the BE1-59NC Capacitor Neutral Overvoltage Relay. Test Plug To allow testing of the relay without removing system wiring, order two test plugs, Basler Electric part number 10095. Extender Board The extender board permits troubleshooting of the printed circuit boards outside of the relay cradle. Order Basler Electric part number 9 1655 00 100. 6

NOTES 7

ROUTE 143, BOX 269, HIGHLAND, ILLINOIS U.S.A. 62249 P.A.E. Les Pins, 67319 Wasselonne Cedex FRANCE PHONE 618-654-2341 FAX 618-654-2351 PHONE (33-3-88) 87-1010 FAX (33-3-88) 87-0808 http://www.basler.com, info@basler.com