Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Similar documents
E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Ordering Information. Self-Powered Tachometer H7ER. Subminiature Tachometers With Improved Appearance and Features. H Large display with 8.

Pressure Sensor. PSAN Series. Compact Digital Pressure Sensors. Features Pressure Measurement Range (Negative, Standard, Compound)

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Self--powered Time Counter

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Absolute Rotary Encoder E6CP

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Multifunction Digital Timer

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Photoelectric Sensors E3F2

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Solid-State Digital Timer

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

K3NX Process Meter OPERATION MANUAL

Type Contact form Model

Digital Flow Switch for Large Flow

Model Number Structure

GC30 Digital Differential Pressure Gauge Operation Manual

Separate Thin Amplifier type. AP-V40AW Series

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Self-powered Totalizer

GC61 Digital Pressure Gauge. Operation Manual

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

Self-powered Totalizer New H7E

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Electromagnetic Type Digital Flow Switch

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

ENC - LKE51 - L I B

Photoelectrics Through-beam Type PA18C.T..., DC

Electrical connection

Electromagnetic Digital Flow Switch

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Frequency/Rate Meter

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Electromagnetic Type Digital Flow Switch

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Digital pressure sensor PPX series

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Weighing Meter. Ordering Information. Highly Functional Weighing Meter with Easy-to-read LED. Base Units

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Capacitive sensor BCT5-S18-UP6X2T-H1151

Electrical connection

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Digital Flow Switch for Air/Water

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

02/11/2015

3-color/ 2-screen display 1

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Cylindrical Photoelectric Sensor CY-100 SERIES

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

APPLICATIONS. Automatic warehouse. Trasportation lines

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

100 : 1. Digital Flow Switch. PFMB Series 66 % 67% 76 % 81% 2-Color Display (Only 200 L type) Compact, Space saving

Linear encoders without bearings incremental System for linear motion feedback

Digital Flow Switch for Water 3 -color/2-screen display

Digital Flow Switch for Water

Installation and Maintenance Instructions for GC51 Rangeable Pressure Transmitter

Safety Light Curtains

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Digital Indicating ORP Meter AER-101-ORP. Instruction Manual

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Operating Instructions

Digital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.

02/11/2015

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

Standard signal metering in wall-mounting case

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

Model Number Structure

Assembly. Front view. LEDs. Parametrization interface. Power Bus

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

LAUREL ELECTRONICS, INC.

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

Technical data. General specifications. Indicators/operating means

Transcription:

Sens Mini-Cube Sens with Easy-to-Read LED Display Industry s smallest, lightest l Both analog bar and digital pressure values are displayed Two independent outputs plus one analog output are available CE approved Ordering Infmation SENSORS range Digital output Analog output Part number Positive pressure 0to100kPa(0to14.5psi) NPN open collect 1to5V -A01C 0to1MPa(0to145psi) (independent, d two -B10C outputs) Negative pressure 0to--101 kpa(0to--14.6 psi) -AN0C ACCESSORIES (ORDER SEPARATELY) Description Panel-mounting Bracket Part number E89-F4

Application Examples CHIP ATTACHMENT CHECKS AIR PRESSURE CHECKS PCB AND WAFER ATTACHMENT CHECKS Specifications RATINGS/CHARACTERISTICS Item -A01C -B10C -AN0C Power supply voltage 12 to 24 VDC ± 10% with a ripple (p-p) of 10% max. Current consumption 70 ma max. (See Note 1.) type Gauge pressure Rated pressure range 0 to 100 kpa(0 to 14.5 psi) 0 to 1 MPa(0 to 145 psi) 0 to--101 kpa(0 to--14.6 psi) setting range 0 to 100 kpa(0 to 14.5 psi) 0 to 1 MPa(0 to 145 psi) 0 to--101 kpa(0 to--14.6 psi) Withstand pressure 400 kpa (58 psi) 1.5 MPa (217.6 psi) 400 kpa (58 psi) Applicable fluid Operating Repeat accuracy (/ output) Linearity Response time (/ output) Non-crosive gas and non-flammable gas Hysteresis, window, and auto-teaching ±1% FS max. ±1% FS max. 5msmax. (This table continues on the next page.)

Specifications Table -- continued from previous page Item -A01C -B10C -AN0C Linear output 1to5V± 5% FS with an output impedance of 1 kω and a permissible resistive load of 500 kω min. / output Load current applied voltage Residual voltage Display(SeeNote2.) Display accuracy Circuit protection Ambient temperature Ambient temperature Operating Stage Ambient humidity Operating/ Stage Temperature influence Voltage influence Insulation resistance Dielectric strength NPN open collect (NO/NC) 30 ma max. 30 VDC max. 1 V max. with a loak current of 30 ma 3.5-digit red LED Green LED bar indicat The ange LED is lit f two independent outputs with output transist turned Green unit indicat ±3% FS ± 1 digit max. Reverse polarity connection, load sht-circuiting 0 Cto55 C (32 F to 131 F) -- 10 C to 60 C (14 F to 140 F) withnoicing 35% to 85% (with no condensation) ±3% FS max. ±1.5% FS max. 100 MΩ min. (at 500 VDC) between current-carry parts and case 1,000 VAC at 1 min Vibration resistance Destruction: 10 to 500 Hz, 1.0-mm double amplitude 150 m/s 2,3timeseachf11mininX,Y, and Z directions Shock resistance 300 m/s 2 (30G) 3 times each in X, Y, and Z directions Degree of protection IEC60529, IP50 pt R(PT) 1/8 male screw and M5 female screw Connection method Pre-wired (standard length: 2 m) Cable Approved by UL Weight (incl. packing material) Approx. 110 g (3.88 oz) Material Aluminum die cast pt Case Heat-resistant ABS Accessies Mounting bracket and instruction sheet Note: 1. The current consumption is approximately 43 ma in energy-saving. 2. Display Example of Digital Indicat Model Setting unit kpa mmhg kgf Applied pressure Digital display -A01C 100 Applied Digital Applied Digital pressure display pressure display. Cannot be set 1. -B10C 1,000 10 -AN0C --101. --760 --1.01.. Note: The. in the display indicates the decimal point. Its position will not change unless the setting unit is changed.

Engineering Data TEMPERATURE VS. LINEAR OUTPUT CURRENT FLUCTUATI (TYPICAL) -A01C TEMPERATURE VS. OPERATING PRESSURE FLUCTUATI (TYPICAL) -A01C Linear output fluctuation (% FS) 0 Rated pressure Operating pressure fluctuation (% FS) Temperature ( C) PRESSURE VS. LINEAR OUTPUT (TYPICAL) -A01C Temperature ( C) LINEARITY (TYPICAL) -A01C Linear output voltage (V) Linearity deviation (%FS) (kpa) (kpa)

Nomenclature PRESSURE SENSOR (1) (2) (4) (3) (5) (6) (7) (8) Display Panel 1. Bar Indicat (Green) Indicates the degree of the measured pressure accding to the the set pressure. 2. Numeric and Menu Display (Red) Indicates measurement values and menu setting items. 3. Unit Indicat (Green) Indicates the unit used f detection. The unit indicated with the indicat is the one currently set. 4. OUT1 Indicat (Orange) Lit when OUT1 is turned. 5. OUT2 Indicat (Orange) Lit when OUT2 is turned. Operation Keys 6. Up Key 7. Down Key Used to select change the set items, set contents, and set values in setting. Press either key to check the and points in measurement. The values are reset by pressing both keys simultaneously. Used together with the SET Key f setting the Sens to a special setting energy-saving. 8. SET Key Used f entering the set contents and set values in setting. Used f setting the Sens to basic setting pressure setting.

Operation OUTPUT STAGE CIRCUIT type NPN output (nmally open) NPN output (nmally closed) Model Timing chart Hysteresis -A01C -B10C -AN0C point point point point OUT indicat (ange) OUT indicat (ange) Window point point point -- 10% FS max. point -- 10% FS max. point point point -- 10% FS max. point -- 10% FS max. circuit OUT indicat (ange) Brown 12 to 24 V OUT indicat (ange) Load 30 ma max. Black (/1) Load 30 ma max. Sens main circuit White (/2) Gray 1to5V (linear) Load Blue 0V

FUNCTIS AND SETTINGS Function/Setting Description Page Zero-reset function Sets the measurement value to 0 when the Sens is exposed to the air. 9 Basic setting setting Special setting Special setting Energy-saving g Unit setting Changes the unit f detection. 9 setting method --- 10 -type setting Selects nmally-open nmally-closed output. 10 Manual setting Sets the and points manually. 11 Auto-teaching setting Automatically sets the and points depending upon the actual 12 sensing of objects. Key-protect setting Protects the set value against the increct operation of the keys. 14 Prevents the set value against the careless operation of the keys. Hysteresis width setting Changes the hysteresis range. 15 Window range setting Changes the window setting. 15 Display refresh interval setting Changes the display refresh interval to make the displayed value easier to 16 see. Measurement value averaging Prevents increct output due to sudden, instantaneous changes that may 16 time setting occur with pressure. LED bar indicat range setting Changes the display range of the LED bar indicat in hysteresis. 16 Energy-saving function 1 Displays the LED bar indicat but turns the red LED display. 18 Energy-saving function 2 The LED bar indicat and red LED display flashes in window if the 18 measured value exceeds the set range. / set value check function Checks the set and points. 18 SETTINGS Digital Display The displays alphanumeric characters, such as the measurement values and menu items, with 7-segment LEDs. Refer to the examples shown below. Display Meaning In output operation Unit (kpa) Width The following abbreviations are used f the digital display of the Controller. Abbreviation Meaning Abbreviation Meaning Unt Unit DSP Display M-A Manual/Auto AVE Average OPE Operation BAR Bar PRT Protect AUT Auto HYS Hysteresis ECO Economy WID Width A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

MODES In addition to displaying measurement values, the has a variety of functions. These functions are available in four main s as described below: Measurement Mode, Basic Setting Mode, Setting Mode, Special Setting Mode. Three functions are available in measurement. F the relationships among each and f switching methods, refer to the following figure. Power Zero-reset function No key operation Energy-saving function 1 - and -point check function No key operation Measurement Energy-saving function 2 Basic Setting Mode Setting Mode Special Setting Mode Manual setting Auto-teaching setting : Measurement unit selection : OUT1 -point setting.: OUT1 two-point teaching : Key-protect setting : setting method selection : OUT1 -point setting. : OUT1 one-point teaching : Hysteresis width setting : -type selection : OUT2 -point setting.: OUT2 two-point teaching : Window width setting : OUT2 -point setting. : OUT2 one-point teaching : Measurement value display refresh interval setting : Number of measurement times setting f measurement value averaging : LED bar indicat range setting Note: 1. and indicate that the key must be pressed f approximately 2 3 s respectively. 2. The following will result when the in basic, pressure setting, special setting is reset to measurement. : The set values are entered. : The set values are not entered (left as they are). *1.Manual setting is available by selecting (manual) in the pressure setting method selection in basic setting. *2.Auto-teaching setting is available by selecting (auto-teaching) in the pressure setting method selection in basic setting.

Zero-reset Function Use the zero-reset function with the Sens exposed to the air. Measurement Nmal Err The displayed measurement value is reset to 0 by pressing the Up and Down Key simultaneously. The reset range is within ±5% (FS) of the rated pressure. If the value is not within the range, an err will be displayed and the reset will not be enabled. Basic Setting Mode The unit of measurement, pressure setting method, and output type are set in basic setting. Measurement Setting item 1. Press the SET Key f approximately 2 s so that the will be set to basic setting and will be displayed. 2. Set the items,, and with Up Down Key. Setting item Unit setting setting method selection -type setting Unit Setting Setting item Unit setting in -AN0C 1. Press the SET Key while is displayed to display the unit presently set. 2. Press the Up Down Key to select the unit. 3. Press the SET Key to select the displayed unit and display again. 4. Press the Up and Down Keys simultaneously, to display unt again without selecting the unit.

Setting Method Selection setting Setting item Manual setting Auto-teaching : Manual setting (The and points are manually set.) : Auto-teaching (The and points are set automatically.) 1. Press the SET Key while is displayed to display the pressure setting method presently set. 2. Press the Up Down Key to select the pressure setting method. 3. Press the SET Key to select the displayed pressure setting method and display again. 4. Press the Up and Down Keys simultaneously to display without selecting the unit. -type Setting Setting item -type setting : Nmally open : Nmally closed 1. Press the SET Key while is displayed to display the output type of OUT1 presently set. 2. Press the Up Down Key to select the output type. 3. Press the SET Key to select the displayed output type and display the output type of OUT2 presently set. 4. Press the Up Down Key to select the output type. 5. Press the SET Key to select the displayed output type and display again. 6. Press the Up and Down Keys simultaneously to display again without selecting the unit. Returning to Measurement Mode Setting item Unit setting setting configuration Entered Not entered Measurement Mode Entering the Setting Item: Press the SET Key f approximately 2 s to enter the item that has been set. Not Entering the Setting Item: Press the Up and Down Keys simultaneously so that the item set will not be entered.

Setting Mode The provides output accding to the measured values to control external devices, such as valves and pumps. In der to control the external devices, a reference value can be set so that the output will be if the measured values are above below the reference value. The output - and -point settings are described below, provided that the output is nmally open. Note: The and points are set in pressure setting manually through auto-teaching. Nmally Open Hysteresis Mode Window Mode -point set value -point set value value -point set value -point set value value Nmally Closed Hysteresis Mode Window Mode -point set value -point set value value -point set value -point value set value Manual Setting Note: Manual setting will be possible if is selected in pressure setting method selection in basic setting. Manual setting Measurement Displayed alternately Displayed alternately Displayed alternately Displayed alternately Press the Up Down Key to change the set value. 1. Press the SET Key, to set the to pressure setting and display the OUT1 point and alternately. 2. Press the Up Down Key to change the OUT1 point. 3. Press the SET Key to select the point and display the OUT1 point and alternately. 4. Press the Up Down Key to change the OUT1 point. 5. Press the SET Key to select the displayed point and display the OUT2 point and alternately. 6. Press the Up Down Key to change the OUT2 point. 7. Press the SET Key to select the point and display the OUT2 point and alternately. 8. Press the Up Down Key to change the OUT2 point. 9. Press the SET Key to select the point and display the OUT1 point and alternately. Returning to Measurement Mode Entering the Setting Item: Press the SET Key f approximately 2 s to enter any item that has been set. Not Entering the Setting Item: Press the Up and Down Keys simultaneously so that any item set will not be entered.

Auto-teaching Auto-teaching allows input measured values to be input as and -point set values instead of key input. One- two-point auto-teaching can be selected. Note: Auto-teaching will be possible if is selected in the pressure setting method selection in basic setting. One-point Teaching value Two-point Teaching value Setting item Measurement Auto-teaching OUT1 two-point teaching OUT1 one-point teaching OUT2 two-point teaching OUT2 one-point teaching.: Teach hysteresis at first point.: Teach window 1. Press the SET Key to set the to pressure setting and to display OUT1 and.. 2. Press the Up Down Key to select the one-point teaching two-point teaching method of OUT1 and OUT2. Two-point Teaching (Hysteresis- Teaching) OUT1 Present measurement value is displayed. Present measurement value is displayed. 1. Press the SET Key under condition 1 below while. is displayed to display the present measurement value. 2. Check the measurement value and press the Set Key to perfm and complete teaching the first point. 3. Press the Set Key under condition 2 below to display the present measurement value.

Two-point Teaching Condition 1 point point Condition 2 value TEACH1 and TEACH2 can be perfmed in reverse der. TEACH1 value can be larger than TEACH2 value vice versa. point: (TEACH1 + TEACH2)/2 point: point -- 3% FS (default value) The default value is changeable. Entered Measurement Not entered 4. Check the measurement value and press the Set Key to perfm and complete teaching the second point. 5. Press the SET Key f approximately 2 s while. is displayed to enter the values and return the to measurement. 6. Press the Up and Down Keys simultaneously to set the to measurement without selecting the values. Note: The will be automatically set to hysteresis by perfming two-point teaching. Two-point teaching is ideal f applications that check f vacuum attachment. Auto-teaching One-point Teaching (Window- Teaching) OUT1 Present value Entered Measurement Not entered 1. Press the SET Key under condition 3 below while. is displayed to display the present measurement value. One-point Teaching Condition 3 point: TEACH1 -- 30% FS point: TEACH1 + 30% FS The default value is 10% FS (changeable). point value point 2. Check the measurement value and press the Set Key to perfm and complete teaching. 3. The values are entered Press the SET Key f approximately 2 s while. is displayed to enter the values and return the to measurement. 4. Press the Up and Down Keys simultaneously to return the to measurement without selecting the values. Note: The will be automatically set to window by perfming one-point teaching. One-point teaching is ideal f applications that check iginal pressure.

Teaching Err Present value not within set range Err display f 1 s Meaning of display:. (Err teach) If the present value the result of calculation after teaching is not within the range, the SET Key input will not be accepted. In this case an err will be displayed f 1 s if teaching is perfmed. Special Setting Mode Key-protect, hysteresis width, window width, display refresh interval, number of measurement times f averaging, and bar indicat range settings are set in special setting. Setting item Measurement Setting item Key-protect Hysteresis width Window width Display refresh interval Number of measurement times f averaging Bar indicat range 1. Press the SET Key and Up Key simultaneously to set the to special setting and display. 2. Set the Up Down Key to select the items,,,,, and. Key-protect Setting No key-protect Press the Up Down Key to change the set value. Key-protect Status 0: No key-protect. 1: No basic pressure settings are accepted. 2: No input is accepted other than f checking the pressure value special settings setting to energy-saving. 1. Press the SET Key while is displayed to display the key-protect value presently set. 2. Press the Up Down Key to change the value. 3. Press the SET Key to select the displayed value and display again. 4. Press the Up and Down Keys simultaneously display again without selecting the value.

Hysteresis Width Setting The hysteresis width can be changed by taking the following steps. Hysteresis Mode Change in hysteresis width desired Press the Up Down Key to change the set value. Window point point point value Change in hysteresis width desired point value 1. Press the SET Key while is displayed to display the hysteresis width of OUT1 presently set. 2. Press the Up Down Key to change the set value within a range between 0 and 10.0% FS. 3. Press the SET Key to select the displayed set value and display the hysteresis width of OUT2 presently set. 4. Press the Up Down Key to change the set value. 5. Press the SET Key to select the displayed set value and display again. 6. Press the Up and Down Keys simultaneously to display again without selecting the value. Note: 1. Hysteresis Mode No manual hysteresis width settings are enabled in hysteresis except f those set by auto-teaching. Window Mode Hysteresis width settings are enabled when the in window is set to measurement. 2. - and -point widths in hysteresis are used as hysteresis widths, which cannot be changed in window. Window Range Setting (0 to 30%) Reference value (TEACH1) value Press Up Down Key to change set value. 1. Press the SET Key while is displayed to display the window width of OUT1 presently set. 2. Press the Up Down Key to change the set value within a range between 0 and 30% FS of the reference value. 3. Press the SET Key to select the displayed set value and display the window width of OUT2 presently set. 4. Press the Up Down Key to change the set value. 5. Press the SET Key to select the displayed set value and display again. 6. Press the Up and Down Keys simultaneously to display again without selecting the set value. Note: No window width settings will be enabled in hysteresis.

Display Refresh Interval Setting The following refresh intervals are selectable. 0.1: The average value is displayed at 0.1-s intervals. 0.5: The average value is displayed at 0.5-s intervals. 1.0: The average value is displayed at 1.0-s intervals. Press Up Down Key to change set value. 1. Press the SET Key while is displayed to display the display refresh interval presently set. 2. Press the Up Down Key to change the set value. 3. Press the SET Key to select the displayed set value and display again. 4. Press the Up and Down Keys simultaneously to display again without selecting the set value. Note: Set the AVE to the number of measurements f obtaining an average value. Measurement Value Averaging Time Setting The number of measurements can be set to 1, 8, 32, 256. Press Up Down Key to change set value. 1. Press the SET Key while is displayed to display the set value as the number of measurements f averaging measured values. 2. Press the Up Down Key to change the set value. 3. Press the SET Key to select the displayed set value and display again. 4. Press the Up and Down Keys simultaneously to display again without selecting the set value. Note: If the DSP item is set to 0.5 and AVE item is set to 32, the will measure 32 times, the average value of which will be treated as one block. The average block value f 0.5 s will be displayed at 0.5-s intervals. Bar Indicat Range Setting The set value is an indication range per LED between 1 and 20% FS. If the is set to AUT, the ideal display range will be set automatically accding to the the point presently set. Press Up Down Key to change set value. 1. Press the SET Key while is displayed to display the bar display range presently set. 2. Press the Up Down Key to change the set value. 3. Press the SET Key to select the displayed set value and display again. 4. Press the Up and Down Keys simultaneously to display again without selecting the set value. Note: The bar indicat range will be available to OUT1 output and will be enabled in hysteresis only.

Bar Indicat The user can visually sense the measured pressure accding to the and points from the bar indicat. This indicat is available to OUT1 output only. There is a difference in indication between hysteresis and window. Hysteresis Mode The five LEDs indicate the present pressure provided that the point is between the second and third LEDs from the left. 1-MPa Model (with 300 kpa as Point) Condition 1 (350 kpa) 300 ( point) value: kpa The indication range per LED is obtained from the following. 300 kpa 1MPax1/2 300 kpa x 1/3 = 100 kpa The first through third LEDs from the left are all under condition 1. The indication range per LED is the set value of the indication range in special setting. If the set value is, the following ranges are obtainable. When point Rated pressure x 1/2 Indication range per LED = point x 1/3 When point > Rated pressure x 1/2 Indication range per LED = (Rated value -- point) x 1/3 Window Mode The distance between and points are divided into five equal ptions. The present pressure will be indicated by a single LED that will be. The left LED will flash if the present pressure is below the point and the right LED will flash if the present pressure is above the point. 1-Mpa Model (with 300 kpa as point and 600 kpa as point) Condition 2 (450 kpa) Condition 3 (700 kpa) 300 kpa ( point) 600 kpa ( point) value: kpa Only LED (a) will be lit under condition 2. Only LED (b) will be lit under condition 3. The display range per LED will be the following. Difference between and points x 1/5 Note: No bar indicat settings in special setting will be enabled. Returning to Measurement Mode Setting Items Key-protect Hysteresis width Window width Display refresh interval Number of measurement times f averaging Bar indicat range setting Entered Not entered Measurement Entering Set Values: Press the SET Key f approximately 2 s while the value is displayed. Not Entering Set Values: Press the Up and Down Keys simultaneously while the value is displayed.

Energy-saving Mode The has functions to save power by turning the numeric and menu display and leaving the bar indicat turned. Energy-saving Function 1 Nmal Measurement Mode 1. The numeric and menu display is turned by pressing the SET and Down Keys simultaneously in measurement. 2. The display is turned by pressing the SET and Down Keys simultaneously again. Energy-saving Function 2 If the present pressure is not within the set range, the numeric and menu display will flash as a warning. beyond the set range is imposed. Displayed f 1 s value flashes. 1. If the SET and Down Keys are pressed simultaneously f approximately 3 s in measurement, will be displayed f 1 s and then the numeric and menu display will be turned. 2. Provided that the is set to window, the numeric and menu display will flash together with the bar indicat if the present pressure is below point above the point. 3. The numeric and menu display and the bar indicat return to nmal condition by pressing the SET and Down Keys simultaneously. - and Set Value Check Function - and -point Set value Measurement Displayed alternately Displayed alternately Displayed alternately Displayed alternately OUT1 point OUT1 point OUT2 point OUT2 point The and points presently set can be checked. Press the Up Down Key in measurement to display the OUT1 point and alternately. Press the Up Down Key again to display the OUT1 point and alternately. Press the Up Down Key after the above to display the OUT2 items. If no key is input f approximately 2 s during the above operation, the present measurement value will be displayed automatically.

Dimensions Unit: mm (inch) CTROLLER Display panel 28 (1.10) 27 2 29 (1.14) 17 1.5 8 25.5 9 (0.35) (0.31) -introducing section Two-M3 (Depth: 6) 28 (1.10) 27 20 (0.79) With Mounting Bracket 20.5 (0.81) Vinyl-insulated round cable with five conducts, 4 dia. (0.08 dia. x 30); standard length: 2 m 6 (0.24) 20 (0.79) Mounting Dimensions Two-M3 27 20.5 (0.81) 29 15 (1.14) (0.59) 20 5.4 (0.79) 42 (1.65) 15 (0.59) 28 (1.10) 20 (0.79) ACCESSORIES E89-F3 Mounting Bracket 9 (0.35) 20.5 (0.81) Two-3.5 (0.14) dia. 27 20 (0.79) 14.5 Four-R1 13.5 20 (0.79) * Provided with 26.9 4.5 Two-3.5 dia. R1.6 max. 1.6 Four-R2.5

E89-F4 PANEL-MOUNTING BRACKET (SOLD SEPARATELY) Panel Cutout Dimensions (E89-F4 is available in the following two sizes.) Spacer not mounted 33 +0.5 0 (1.30 +0.02 ) 0 Spacer mounted 36 +0.5 0 (1.42 +0.02 ) 0 Panel 33 +0.5 0 36 +0.5 (1.42 +0.02 0 ) 0 40 (1.57) Panel 40 (1.57) Note: The spacer can be removed from the panelmounting bracket. The panel cutout dimensions can be adjusted as shown above by attaching detaching the spacer. Spacer

Precautions ENVIRMENT Do not use the Sens in locations subject to explosive flammable gases. Do not use the Sens in an environment subject to crosive combustible gases. Make sure that the Sens is free of water. AVOID DAMAGE TO THE Do not impose any voltage exceeding the rated voltage on the. Do not sht-circuit the load connected to the. When supplying power to the, make sure that the polarity of the power is crect. WIRING Do not wire power lines high-tension lines adjacent to the lines of the. If no linear output is used, cut the gray lead wire sht and apply insulating tape to the lead wire so that it will not come into contact with any other terminal. MOUNTING Mount the Sens so that ultrasonic vibrations will not be applied directly to the Sens. Do not insert any wire into the pressure pt. Doing so may damage the pressure elements and cause a malfunction. Do not apply a tensile strength in excess of 50 N to the cds connects. The pressure-introducing section (aluminum die-cast made) is fixed with tapered R(PT)1/8 male screws and M5 female screws. When using tapered screws, use tapered Rc(PT)1/8 female screws. Wrap the tapered R(PT)1/8 male screws with sealing tape to prevent any leakage. Tighten the male screws to a tque of 10 N mmax. Tighten M5 female screws to a tque of 2 N mmax. Tightening each male screw by using a 12-mm wrench to hold its hexagonal head, not the screw itself. USE Filter the gas with an appropriate air filter so that the applied gas will be free of moisture oil. Be sure to use the Sens under the rated pressure. When setting the set pressure of the point of the output transist by pressing the selection key, use a manometer measures pressure if precise pressure settings are required. The Sens has a display err of 3% FS ±1 digit at room temperature. Refer to Specifications. Reset Time: the Sens is ready to operate 0.5 s after the Sens is turned. Hexagonal head When attaching the Mounting Bracket to the Sens, make sure that each M3 screw is tightened to a tque of 0.5 N mmax.

NOTE: DIMENSIS SHOWNARE IN MILLIMETERS. Toconvert millimeters to inches divide by 25.4. Omron Europe B.V. EMA-ISD, tel:+31 23 5681390, fax:+31 23 5681397, http://www.eu.omron.com/ema Cat. No. D086-E3-1 4/99 Specifications subject to change without notice. Printed in U.S.A.