SIMATIC. ET 200S distributed I/O 2AO U HS analog electronic module (6ES7135-4FB52-0AB0) Preface. Properties 1. Parameters 2.

Similar documents
SIMATIC. ET 200S distributed I/O IM151-1 BASIC interface module (6ES7151-1CA00-0AB0) Preface. Properties 1. Parameters 2. Error and system messages 3

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Function Manual SIMATIC HMI TP900. Operator Panel.

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

MICROMASTER Encoder Module

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

Digital output modules

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

SOFTLINK 300. Modules Specifications. Reference Manual

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Gamma instabus. Technical product information

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

USER S MANUAL. FX2N-8AD Analog input block

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

A/D and D/A convertor 0(4) 24 ma DC, 16 bits

Standard signal metering in wall-mounting case

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Electrical connection

Safety Light Curtain C 4000

Dimming actuators GDA-4K KNX GDA-8K KNX

Electrical connection

C200H-AD002/DA002 Analog I/O Units Operation Guide

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

Trusted 40 Channel 120 Vac Digital Input FTA

User Guide. Centrex Recording Interface

SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA

Siemens Industry Online Support

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

(Cat. No IJ, -IK)

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

48x24. Options ORDER NUMBER OF TYPE PFL B

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Trusted 40 Channel 120 Vac Digital Input FTA

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

Model Number Structure

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

K-BUS Dimmer Module User manual-ver. 1

Fibre Optic Modem ODW-611

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

Absolute Encoders Multiturn

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

Operating Instructions

ER-100 Eurorack 8 Channel Stereo, Transformer Balanced Out Summing Mixer User Manual

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

S6-R READER. Installation and Operating Instructions

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Trusted 40 Channel Analogue Input FTA

Electronic converter for level transmitters MT03L Instructions manual

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

CEDES. Functional description CEDES 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN)

K3NX Process Meter OPERATION MANUAL

3 Cleaning. 4 Technical data

Fibre Optic Modem ODW-622

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

AI-1204Z-PCI. Features. 10MSPS, 12-bit Analog Input Board for PCI AI-1204Z-PCI 1. Ver.1.04

ODW-621. RS-232 Point-to-point applications

Tech Support: Customer Service: General Tech Questions: Tech Docs:

FP-QUAD-510. Features. Power Requirement OPERATING INSTRUCTIONS. 4-Axis, Quadrature Input Module

FX2N-2AD SPECIAL FUNCTION BLOCK

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

FX0N-3A SPECIAL FUNCTION BLOCK

32 Channel CPCI Board User Manual

P2-HSI High-Speed Isolated Sinking/Sourcing Input. Connector Specifications

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

HP SMA BFOC. Brief instruction. Version. 4en.

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

GuardPLC Certified Function Blocks -- Basic Suite

2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. KNX LED dimmer Constant voltage 4gang with power adaptor 6155/40-500

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

Single cable multiswich programmer PC102W

Innovation in Magnetic Measuring Instruments. Operation Manual for. Mag648 and Mag649 Low Power Three-Axis Magnetic Field Sensors.

SIMOREG DC Master. Application SIMOREG 1Q-device, braking to defined speed using reversing. 6RA70 Series

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

User Manual CVA3. HDMI Audio Decoder. All Rights Reserved. Version: CVA3_2016V1.0

Siemens Industry Online Support

3G/HD/SD-SDI to HDMI Converter

Transcription:

SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO U HS analog electronic module (6ES7135-4FB52-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation 4 Connecting 5 01/2008 A5E01001757-02

Safety Guidelines Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE Qualified Personnel Prescribed Usage Trademarks indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Note the following Disclaimer of Liability WARNING This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. 이기기는업무용 (A 급 ) 전자파적합기기로서판매자또는사용자는이점을주의하시기바라며가정외의지역에서사용하는것을목적으로합니다. Siemens AG Automation and Drives Postfach 48 48 90327 NÜRNBERG GERMANY A5E01001757-02 P 02/2008 Copyright Siemens AG 2008. Technical data subject to change

Preface Purpose of the manual This manual supplements the ET 200S Distributed I/O System Operating Instructions. General functions for the ET 200S are described in the ET 200S Distributed I/O System Operating Instructions. The information in this document along with the operating instructions enables you to commission the ET 200S. Basic knowledge requirements To understand these operating instructions you should have general knowledge of automation engineering. Scope of the manual This manual applies to this ET 200S module. It describes the components that are valid at the time of publication. Recycling and disposal Thanks to the fact that it is low in contaminants, this ET 200S module is recyclable. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste. Additional support If you have any questions relating to the products described in these operating instructions, and do not find the answers in this document, please contact your local Siemens representative. http//www.siemens.com/automation/partner The portal to our technical documentation for the various SIMATIC products and systems is available at http//www.siemens.com/automation/simatic/portal The online catalog and ordering system are available at http//www.siemens.com/automation/mall Manual, 01/2008, A5E01001757-02 3

Preface Training center We offer courses to help you get started with the ET 200S and the SIMATIC S7 automation system. Please contact your regional training center or the central training center in D -90327, Nuremberg, Germany. Phone +49 (911) 895-3200. http//www.siemens.com/sitrain Technical Support You can reach technical support for all A&D projects using the support request web form http//www.siemens.com/automation/support-request Phone + 49 180 5050 222 Fax + 49 180 5050 223 For more information about our technical support, refer to our Web site at http//www.siemens.de/automation/service Service & Support on the Internet In addition to our documentation services, you can also make use of our comprehensive online knowledge base on the Internet. http//www.siemens.com/automation/service&support There you will find Our Newsletter, which constantly provides you with the latest information about your products. The right documentation for you using our Service & Support search engine. The bulletin board, a worldwide knowledge exchange for users and experts. Your local contact for Automation & Drives in our contact database. Information about on-site services, repairs, spare parts. Lots more can be found on our "Services" pages. 4 Manual, 01/2008, A5E01001757-02

Table of contents Preface... 3 1 Properties... 7 1.1...7 2 Parameters... 13 2.1 Parameters...13 3 Diagnostics... 15 3.1 LED displays on analog electronic modules...15 3.2 Channel-related diagnostics - error types...16 4 Analog value representation... 17 4.1 Introduction...17 4.2 Analog value representation for measuring range with SIMATIC S7...17 4.3 Output ranges for 2AO U HS...18 4.4 Effect on analog value representation...19 4.4.1 Influence of the supply voltage and the operating state on analog output values...19 4.4.2 Influence of the value range on the 2AO U HS analog output...20 4.4.3 Effect on the change rate of the output signals...20 5 Connecting... 21 5.1 Connecting analog outputs...21 5.2 Using the shield connection...21 Index... 23 Manual, 01/2008, A5E01001757-02 5

Table of contents 6 Manual, 01/2008, A5E01001757-02

Properties 1 1.1 Properties 2 outputs for voltage output Output range ± 5 V, resolution 15 bit + sign ± 10 V, resolution 15 bits + sign 1 to 5 V, resolution 14 bits Isolated from the load voltage L+ Supports isochrone mode Minimum possible time for the isochronous DP cycle (TDPmin) 250 µs Minimum possible conversion time of the output modules (TWA) 100 µs Firmware update of electronic module is possible. General terminal assignment Note Terminals A4, A8, A3, and A7 are only available at specified terminal modules. Terminal assignment for 2AO U HS (6ES7135-4FB52-0AB0) Terminal Assignment Terminal Assignment Notes 1 QV0 5 QV1 QVn Analog output voltage, Channel n 2 S0+ 6 S1+ Sn+ Sensor cable positive, Channel n 3 Mana 7 Sn- Sensor cable negative, Channel n Mana 4 S0-8 Mana Ground of the module S1- AUX1 Protective-conductor terminal or voltage bus (freely usable A4 AUX1 A8 AUX1 up to 230 VAC) A3 AUX1 A7 AUX1 Manual, 01/2008, A5E01001757-02 7

Properties 1.1 Usable terminal modules Usable terminal modules for 2AO U HS (6ES7135-4FB52-0AB0) TM-E15C26-A1 (6ES7193-4CA50-0AA0) TM-E15S26-A1 (6ES7193-4CA40-0AA0) TM-E15N26-A1 (6ES7193-4CA80-0AA0) TM-E15C24-01 (6ES7193-4CB30-0AA0) TM-E15S24-01 (6ES7193-4CB20-0AA0) TM-E15N24-01 (6ES7193-4CB70-0AA0) Spring terminal Screw-type terminal Fast Connect 8 Manual, 01/2008, A5E01001757-02

Properties 1.1 Block diagram µ Figure 1-1 Block diagram of the 2AO U HS Technical specifications for 2AO U HS (6ES7135-4FB52-0AB0) Dimensions and weight Width (mm) 15 Weight Approx. 40 g Module-specific data Supports isochrone mode Yes Supports I&M functions Yes Number of outputs 2 Cable length Shielded Max. 200 m Max. 20 m for TWA= 100 µs Parameter length 7 bytes Address space 4 bytes Voltages, currents, potentials Rated load voltage L+ (from the power 24 VDC module) Reverse polarity protection Yes Electrical isolation Between the channels and backplane bus Yes Between the channels and load voltage L+ Yes Between the channels No Permissible potential difference Between MANA and the central grounding 75 VDC / 60 VAC point (Uiso) Insulation tested 500 VDC Current consumption From load voltage L+ Max. 130 ma Power loss of the module Typically 2.2 W Status, interrupts, diagnostics Diagnostics function Group error display Red "SF" LED Diagnostic information readable Supported Substitute values can be applied Yes, assignable Manual, 01/2008, A5E01001757-02 9

Properties 1.1 Analog value generation Resolution (including sign) ± 5 V/15 bit + sign ± 10 V/15 bits + sign 1 to 5 V/14 bits Conversion time in µs (per channel) Max. 20 µs Cycle time in ms (per module) 0.25 ms Settling time 1 For resistive load 0.05 ms For capacitive load 0.05 ms For inductive load 0.05 ms Interference suppression, error limits Crosstalk between the outputs > 60 db Operational limit ± 0,2 % (in the entire temperature range, with reference to the output range) Basic error limit (operational limit at 25 C with ± 0,1 % reference to output range) Temperature error (with reference to the ± 0.01 %/K output range) Linearity error (with reference to the output ± 0,03 % range) Repeatability (in steady state at 25 C with ± 0,03 % reference to output range) Output ripple; bandwidth 0 to 50 khz (relative ± 0,02 % to output range) Actuator selection data Output range (rated value) ± 5 V ± 10 V 1 to 5 V Load impedance (in the nominal range of the output) at voltage outputs, capacitive load Min. 1.0 kω/ 1 µf At voltage outputs Max. 0.1 µf for TWA 100 µs Voltage output Short-circuit protection Short-circuit current Yes approx. 25 ma Destruction limit against voltages/currents applied from outside Voltage at the outputs to MANA Max. 15 V/ 5 hours Current Max. DC 30 ma Connection of actuators Voltage output 2-conductor connection 4-conductor connection Possible 1 at a max. load of 1 kω/ 100 nf and a max. cable length of 20 m Possible, without compensation of the cable resistances 10 Manual, 01/2008, A5E01001757-02

Properties 1.1 Firmware update (as of revision level 03) To add functions and for troubleshooting, it is possible to load firmware updates to the operating system memory of the electronic module using STEP 7 HW Config. Note When you launch the firmware update, the old firmware is deleted. If the firmware update is interrupted or canceled, the electronic module will no longer be capable of functioning. Restart the firmware update and wait until it has completed successfully. Note If the ET 200S is operated in conjunction with an S7-300 CPU with PROFIBUS DP interface or an ET 200S Interface Module IM151-3 PN HIGH SPEED, a station failure of the ET 200S can occur during the firmware update. I&M functions and firmware update The interface modules identified in the table below (as of order number) can be used to read and write I&M data from the module and for the firmware update. Interface module IM151-1 HIGH FEATURE IM151-3 PN IM151-3 PN HIGH FEATURE IM151-3 PN FO IM151-7 CPU as of order number 6ES7151-1BA02-0AB0 6ES7151-3AA22-0AB0 6ES7151-3BA22-0AB0 6ES7151-3BB22-0AB0 6ES7151-7AA20-0AB0 Manual, 01/2008, A5E01001757-02 11

Properties 1.1 12 Manual, 01/2008, A5E01001757-02

Parameters 2 2.1 Parameters Parameters for the 2AO U HS analog electronic module Table 2-1 Parameters for the 2AO U HS analog electronic module Parameters Range of values Default setting Applicability Group diagnostics Disable Disable Module (parameter assignment Enable error, internal error) Diagnostics shortcircuit Disable Disable Channel to M 1 Enable Reaction to Output has no Output has no current Module CPU/Master STOP current or voltage Substitute a value Keep last value or voltage Type/range of output Deactivated ± 5 V ± 10 V 1 to 5 V ± 10 V Channel Substitute value To 65535 (value range ± 5 V 0 V Channel must be within the ± 10 V 0 V nominal range) 1 to 5 V 1 V 1 No diagnostic detection between -0.296 V and +0.296 V Note If you deactivate a channel of the electronic module, you do not gain any advantages in terms of speed due to the measuring procedure. Manual, 01/2008, A5E01001757-02 13

Parameters 2.1 Parameters 14 Manual, 01/2008, A5E01001757-02

Diagnostics 3 3.1 LED displays on analog electronic modules Analog electronic modules LED displays on analog electronic modules 1 1 Batch error (red) Status and error displays by means of LEDs on analog electronic modules The table below shows the status and error displays on the analog electronic modules. Event (LED) SF values Cause No configuration or incorrect module plugged in. No load voltage.present There is a diagnostic message. Remedy Check the parameter assignment. Check the load voltage. Evaluate the diagnostics. Manual, 01/2008, A5E01001757-02 15

Diagnostics 3.2 Channel-related diagnostics - error types 3.2 Channel-related diagnostics - error types Analog output module error types Table 3-1 Error types 31D 16D Error type Meaning Remedy 11111 Channel temporarily The firmware is being --- unavailable updated. Channel 0 applies to the entire module. The module does not output any values during this time. 10000 Parameter assignment error Module cannot utilize the parameters for the channel Inserted module does not match the configuration. Incorrect parameter assignment. 9D 01001 Error Internal module error has occurred (diagnostic message on channel 0 applies to the whole module). 1D 00001 short-circuit Short circuit of the actuator supply. Correct the configuration (align actual and preset configuration). Correct the parameter assignment (wire break diagnostics assigned only for the allowed measuring ranges). Replace the module. Correct the process wiring. 16 Manual, 01/2008, A5E01001757-02

Analog value representation 4 4.1 Introduction Electronic modules with analog outputs With the electronic modules with analog outputs, digital values set by a controller can be converted to a corresponding analog signal (current) in an analog output module and used to control suitable actuators (setpoint input for speed controllers, temperature controllers and similar). 4.2 Analog value representation for measuring range with SIMATIC S7 Analog value representation With the same nominal range, the digitized analog value is the same for input and output values. Analog values are represented in two's complement. The following table shows the analog value representation for the analog electronic modules. Table 4-1 Analog value representation (SIMATIC S7 format) Resolution Analog value Bit number 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Significance of the bits S 2 14 2 13 2 12 2 11 2 10 2 9 2 8 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0 Sign The sign (S) of the analog value is always in bit number 15 "0" + "1" Manual, 01/2008, A5E01001757-02 17

Analog value representation 4.3 Output ranges for 2AO U HS Analog values The following table shows the representation of the binary analog values and the corresponding decimal and hexadecimal representation of the units of the analog values. The table below shows the 11, 12, 13, 14, and 15 bit resolutions + sign. Each analog value is entered left aligned in the ACCU. The bits marked with "x" are set to "0". Table 4-2 Analog values (SIMATIC S7 format) Resolution in bits Units Analog value Decimal Hexadecimal High byte Low byte 11+S 16 10H S 0 0 0 0 0 0 0 0 0 0 1 x x x x 12+S 8 8H S 0 0 0 0 0 0 0 0 0 0 0 1 x x x 13+S 4 4H S 0 0 0 0 0 0 0 0 0 0 0 0 1 x x 14+S 2 4H S 0 0 0 0 0 0 0 0 0 0 0 0 0 1 x 15 + sign 1 1H S 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 4.3 Output ranges for 2AO U HS Output ranges for voltage and current ± 5 V, ± 10 V Table 4-3 SIMATIC S7 format Output range ± 5 V, ± 10 V Output range ± 5 V Output range ± 10 V Decimal Units Hexadecimal 0 0 > 32511 > 7EFFH Overflow 5.8800 11.7589 32511 5.0002 10.0004 27649 6C01H 5.0000 10.0000 27648 6C00H 3.7500 7.5000 20736 5100H Nominal range - 3.7500-7.5000-20736 AF00H - 5.0000-10.0000-27648 9400H - 5.0002-10.0004-27649 93FFH Underrange - 5.8800-11.7589-32512 8100H 0 0 < -32512 < 8100H Underflow 7EFFH Overrange Range 18 Manual, 01/2008, A5E01001757-02

Analog value representation 4.4 Effect on analog value representation Output ranges for voltage and current 1 to 5 V Table 4-4 SIMATIC S7 format Output ranges 1 to 5 V Output range Units Range 1 to 5 V Decimal Hexadecimal 0 > 32511 > 7EFFH Overflow 5.7000 32511 7EFFH Overrange 5.0002 27649 6C01H 5.0000 27648 6C00H Nominal range 1.0000 0 0H 0.9998-1 FFFFH Underrange 0-6912 E500H 0 < -6913 < E4FFH Underflow 4.4 Effect on analog value representation 4.4.1 Influence of the supply voltage and the operating state on analog output values The output values of the analog modules are dependent on the supply voltage for electronics/sensors and on the operating state of the PLC (CPU of the DP master). The table below shows this dependency. Table 4-5 Dependence of the analog output values on the operating state of the PLC (CPU of the DP master) and the supply voltage L+ Operating state of the PLC (CPU of the DP master) POWER ON RUN POWER ON POWER OFF - STOP Supply voltage L+ on ET 200S (power module) L+ present Output value of the electronic module with analog outputs PLC values Until first value output After startup, a signal of 0 ma or 0 V is output. Dependent on the "CPU/ Master STOP" parameter. L+ missing - L+ present Dependent on the "CPU/ Master STOP" parameter. L+ missing - L+ present Dependent on the "CPU/ Master STOP" parameter. L+ missing - Manual, 01/2008, A5E01001757-02 19

Analog value representation 4.4 Effect on analog value representation 4.4.2 Influence of the value range on the 2AO U HS analog output The response of the electronic modules with analog outputs depends on the part of the value range in which the input values are located. The table below shows this dependency. Table 4-6 Behavior of the analog modules, depending on the location of the analog input value in the range of values Output value is in... Nominal range Overrange/underrange Overflow Underflow Prior to parameter assignment, or incorrect parameter assignment Input value in SIMATIC S5/S7 format Value from DP master Value from DP master 0-signal 0-signal 0-signal 4.4.3 Effect on the change rate of the output signals Factors The following factors influence the change rate of the output signals Length, impedance, and capacitance of the cable Input impedance and capacitance of the actuators See also (Page 7) 20 Manual, 01/2008, A5E01001757-02

Connecting 5 5.1 Connecting analog outputs Introduction This chapter describes the factors to consider when connecting the analog outputs. Cables for analog signals You should use shielded and twisted-pair cables for the analog signals. This reduces the effect of interference. You should ground the shield of the analog cables at both ends of the cables. If there are differences in potential between the ends of the cable, an equipotential bonding current flows over the shield, which can interfere with the analog signals. In this case, you should only ground the shield at one end of the cable. Analog output modules In the case of the analog output modules there is generally galvanic isolation Between logic and backplane bus. Between the load voltage and MANA. Note Ensure that this potential difference UISO does not exceed the permitted value. If there is a possibility of exceeding the permitted value, make a connection between terminal MANA and the central grounding point. 5.2 Using the shield connection Rules To prevent interference we recommend the following with the analog electronic modules Use shielded wires to the sensors and actuators. Lay out the wire shields on the shield connection. Connect the shield connection with low impedance to the ground bus. Manual, 01/2008, A5E01001757-02 21

Connecting 5.2 Using the shield connection 22 Manual, 01/2008, A5E01001757-02

Index 2 2AO U HF analog electronic module Block diagram, 9 Properties, 7 Technical specifications, 9 Terminal assignment, 7 A Analog electronic modules, 15 Analog output modules, 21 Error types, 16 Analog output modules in SIMATIC S7 format, 18 Analog value processing, 21 Analog value representation, 21 B Basic knowledge requirements, 3 Behavior of the analog modules, 19 During operation, 19 In case of faults, 19 C Cables for analog signals, 21 Connecting, 21 M Measured value resolution, 18 Measuring ranges with SIMATIC S7, 17 Measuring sensors, 21 O Output ranges, 18 R Recycling, 3 S Scope Manual, 3 Service & Support, 4 Shield contact, 21 T Technical Support, 4 Training center, 4 D Disposal, 3 I Internet Service & Support, 4 Manual, 01/2008, A5E01001757-02 23

Index 24 Manual, 01/2008, A5E01001757-02