RYKO Italia s.r.l. V. Casale Morano Po (Al) t f

Similar documents
AF-300 E11 Adjustable Frequency Drive

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

ADJUSTABLE SPEED DRIVES. nc1 Drive

Understanding VFD. Variable Frequency Drive. nfi. nfi

VAT 20 Adjustable Frequency Drive

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

2. Using LCD Digital Operator

Electronic Lineshaft With Alignment F7 Drive Software Technical Manual

RM5 User Manual Warnings.

Basic Specifications. Driver Model SD12B/15B SD20B SD30B SD30C SD40C SD50C SD75C

DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER. For the DAAB EP104 automatic control system with software version 4.

Inverters Selection Guide

Frequency Converter EFC 3610, EFC 5610

Single Axis Position Controller

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Motion Control G7 Drive Software Technical Manual

Frequency Converter EFC 3610, EFC 5610

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Inverters Selection Guide

ENGINEERING PUBLICATION

SOFT STARTER. We are delivering Real Cost Benefits CD AUTOMATION POWERED BY INNOVATION. Soft Starter Catalog 2018 Release n.

Atlas Drop In Decoder

Low-cost labelling system

Digital Ratio Controller

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

Variable Speed Drives OMRON/YASKAWA F7Z - series

02/11/2015

Software Wizard Makes Configuring the 2301E Easier Configuration Wizard Now Included in 2301E Service Tool

Synchronization Check Relay ARGUS 7

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

RYKO Italia s.r.l. V. Casale Morano Po (Al) t f ITALIA SERVICE BULLETIN - #1-002 Senco 5 Adjustment (revised)

Transmitter Interface Program

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Variwrap Controller Manual

Frequency Converter Fv

Model IQ4-PC User Manual Revision Date:

High performance circuit breakers

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

SIMOREG DC Master. Application SIMOREG 1Q-device, braking to defined speed using reversing. 6RA70 Series

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

LE062XF DCC Decoder for Atlas N Scale Locomotives

PRINCIPLES AND APPLICATIONS

CDHD Servo Drive. Technical Training Manual. Manual Revision: 2.0 Firmware Version: 1.3.x Software Version: 1.3.x.x

1. Type identification Nameplate Nameplate, IO Nameplate, CU Configuration file label...

DLP200M 2 Relay Module for Heating and Cooling Plants

MICROMASTER Encoder Module

GENMARK Engineering & Management # Street Edmonton, AB T5S 1R5 CANADA Phone (780) Fax (780)

DZ143. Z Scale. Mobile Decoder 1.25 Amp/2 Amp Peak 4 FX 3 Functions, 0.5 Amp. Fits Many Z, N and HO Scale Locomotives

Frequency Converter EFC 3610, EFC 5610

Operating instructions Electronic preset counter Type series 717

PIPV200 QUAD System. User Manual

Factory configured macros for the user logic

Automatic Transfer Switch Control PLC Operator s Manual

Rotary Knife Controller

KNX Dimmer RGBW - User Manual

MC700 / MC720 Motion Control Firmware for Rotating Cutters and Printing Rolls. Cutting Pulse Sensor Optional: Print Mark Sensor

Decoder version 3.5. Plug and play decoder for N-Scale Atlas Classic Series GP7, GP9, GP30, GP35

STX Stairs lighting controller.

Noise Detector ND-1 Operating Manual

SPECIFICATION NO NOTE

Panasonic Broadcast. AW-HE100 Menu Information

Basic, cost-effective motor control in one unit: MOVITRAC 07.

21 Channel Light Show PWM LED Controller with Remote Control

Form C: Type Test Verification Report

Series CT7N Bimetallic Overload Relays

Form C: Type Test Verification Report

Computer Controlled Advanced Industrial Servosystems Trainer (for AC motors) SERIN/CA

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

17.2 Setting the slow speed Important advice on ABC Push-pull (shuttle) train control Push-pull operation without

Product Catalog Frequency Converters

Bulletin 190 IEC Modular Starter System

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

Gamma instabus. Technical product information

Product Discontinuation Notices. Discontinuation Notice of built-in Power Supply Photoelectric sensors E3B2 series

TUSKIN Equipment Corporation

Luminaire installation box Surface-mounted box Ceiling installation box

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER

Close supervision. Simplicity of use. Productivity gains. Control relay. C-Lynx. Instinctive control

Manual. MOVIDRIVE MDX61B DRS11B Synchronous Operation Card. Edition 10/ / EN

RG NDT INTERNATIONAL INC. Drill Pipe and Tubing Inspection System

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

MOVIDRIVE Drive Inverters

Click Here To Start Demo

From the above diagram, the relationship between X1, X2, X a and C a is given by the following equations:

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

INTRODUCTION INTRODUCTION

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Selection guide siemens.com/sirius-modular-system

User interface. Abbreviations / Meanings

CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES

SPECIFICATION NO Model 207 Automatic GTAW Welding System

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ABB CM-UFD.M31 monitoring datasheet

Transcription:

Italia RYKO Italia s.r.l. V. Casale 43-15025 Morano Po (Al) t.0142 494411 f. 85872 June 30, 2003 ITALIA SERVICE BULLETIN - # 4-013 VFD parameter settings for conveyor equipment with Mitsubishi PLC MACHINES AFFECTED: Mini Vista, Vista, Vista Plus, and Super Vista conveyor equipment with a Mitsubishi PLC. PROBLEM: Field does not have the parameter settings required for proper operation of the Mitsubishi Variable Frequency Drives. SOLUTION: Refer to the following pages that contain the parameter settings and the procedure to enter the parameter settings. The VFD parameters that need to be changed are highlighted in the Operational setting column. All other parameters remain at the factory setting. ADDITIONAL INFORMATION: Do not use these parameters settings for conveyor equipment with an Omron PLC. See Italia service bulletin 4-002 for the parameter settings for conveyor equipment with an Omron PLC.

Procedure for changing parameter settings with a Mitsubishi FR-S520. 1. Press the PU/EXT key. Observe the PU light on the display turn ON. 2. Press the MODE key to enter the parameter setting mode. Observe P 0 on the display. 3. Turn the setting dial until the desired parameter number appears on the display. Example: P 7 4. Once the parameter to be changed is on the display, press the SET key. This displays the current value set for that parameter. Example: 5.0 5. Turn the setting dial until the desired value appears on the display. Example: 10.0 6. Press the SET key to set the value. Observe 10.0 and P 7 flicker on the display indicating the parameter write is successful. By turning the setting dial, other parameters may be viewed. To change, proceed from step #5 as listed above. By pressing the SET key twice, it will automatically advance to the next parameter. FR-S520 VFD Operational Panel RUN indicator indicates operation when lit PU/EXT key use to switch between PU and external operation mode. 3 digit monitor LED PU indicator indicates PU operation mode EXT indicator indicates external operation mode _ + RUN PU EXT PU EXT RUN STOP RESET RUN key used to give a manual forward rotation command STOP/ RESET key Used to stop an operation or reset an alarm. MODE SET Setting dial MODE key use to change the setting mode SET key use to define each setting

CONVEYOR MINI VISTA, VISTA AND VISTA PLUS Mitsubishi VFD FR-S520S 1.5 kw Parameter Function description Factory setting Operational setting P0 Torque boost 6 % 5 P1 Maximum frequency * 50-60 Hz 70 P2 Minimum frequency 0 Hz 50 P3 Base frequency * 50-60 Hz P4 Speed setting (high) * 50-60 Hz 70 P5 Speed setting (middle) 30 Hz P6 Speed setting (low) 10 Hz 70 P7 Acceleration time 5 sec. 0.5 P8 Deceleration time 5 sec. 0.3 P9 Electronic thermal O/L relay ** Rated current 4.5 P10 DC brake operation frequency 3 Hz P11 DC brake operation time 0.5 sec P12 DC brake voltage 6 % P13 Starting frequency 0.5 Hz P14 Load pattern selection 0 P15 Jog frequency 5 Hz P16 Jog accel/decel time 0.5 sec. P17 RUN rotation selection 0 P18 P19 Base frequency voltage 888 260 P20 Accel/decel reference freq. * 50-60 Hz P21 Stall prevent function select 0 P22 Stall prevent operate level 150 % P23 Double speed stall prevent --- P24 Speed setting (4) --- P25 Speed setting (5) --- P26 Speed setting (6) --- P27 Speed setting (7) --- P28 Stall prevent reduction freq. * 50-60 Hz P29 Accel/decel pattern 0 P30 Ext. function display select 0 P31 Frequency jump 1A --- P32 Frequency jump 1B --- P33 Frequency jump 2A --- P34 Frequency jump 2B --- P35 Frequency jump 3A --- P36 Frequency jump 3B --- P37 Speed display 0 P38 Frequency voltage gain * 50-60 Hz P39 Frequency current gain * 50-60 Hz

P40 Start time ground fault * 1-0 P41 Frequency sensitivity 10 % P42 Output frequency detect 6 Hz P43 Output freq. Reverse --- P44 Second accel/decel time 5 sec. P45 Second deceleration time --- P46 Second torque boost --- P47 Second V/F --- P48 Output current level detect 150 % P49 Output current detect delay time 0 sec. P50 Zero current detect level 5 % P51 Zero current detect time 0.5 sec. P52 Control panel display data 0 P53 Frequency set selection 0 P54 FM terminal function select 0 P55 Frequency monitor reference * 50-60 Hz 60 P56 Current monitor reference ** Rated current P57 Restart coasting time --- P58 Restart cushion time 1 sec. P59 Remote set function select 0 P60 RL terminal function select 0 P61 RM terminal function select 1 P62 RH terminal function select 2 P63 STR terminal function select --- P64 RUN terminal function select 0 P65 A,B,C terminal function select 99 11 P66 Retry selection 0 1 P67 Number of retry at alarm 0 1 P68 Retry wait time 1 sec. 2.5 P69 Retry display erase 0 P70 Soft-PWM setting 1 P71 Applied motor 0 P72 PWM frequency select 1 P73 0-5/0-10V select 0 P74 Input filter time constant 1 P75 Reset select 14 P76 Cooling fan operate select 1 P77 Parameter write disable select 0 P78 Reverse rotate select 0 P79 Operation mode select 0 2 * Factory setting determined by EC or non-ec unit. ** The rated current depends on the VFD capacity, either 1.5 kw or.37 kw.

CONVEYOR SUPERVISTA Mitsubishi VFD FR-S520S 1.5 kw Parameter Function description Factory setting Operational setting P0 Torque boost 6 % 5 P1 Maximum frequency * 50-60 Hz 90 P2 Minimum frequency 0 Hz 50 P3 Base frequency * 50-60 Hz P4 Speed setting (high) * 50 60 Hz 70 P5 Speed setting (middle) 30 Hz 90 P6 Speed setting (low) 10 Hz 70 P7 Acceleration time 5 sec. 1 P8 Deceleration time 5 sec. 0.3 P9 Electronic thermal O/L relay **Rated 5.5 current P10 DC brake operation frequency 3 Hz P11 DC brake operation time 0.5 sec P12 DC brake voltage 6 % P13 Starting frequency 0.5 Hz P14 Load pattern selection 0 P15 Jog frequency 5 Hz P16 Jog accel/decel time 0.5 sec. P17 RUN rotation selection 0 P18 P19 Base frequency voltage 888 260 P20 Accel/decel reference freq. * 50-60 Hz P21 Stall prevent function select 0 P22 Stall prevent operate level 150 % P23 Double speed stall prevent --- P24 Speed setting (4) --- P25 Speed setting (5) --- P26 Speed setting (6) --- P27 Speed setting (7) --- P28 Stall prevent reduction freq. * 50 60 Hz P29 Accel/decel pattern 0 P30 Ext. function display select 0 P31 Frequency jump 1A --- P32 Frequency jump 1B --- P33 Frequency jump 2A --- P34 Frequency jump 2B --- P35 Frequency jump 3A --- P36 Frequency jump 3B --- P37 Speed display 0 P38 Frequency voltage gain * 50 60 Hz P39 Frequency current gain * 50 60 Hz

P40 Start time ground fault * 1-0 P41 Frequency sensitivity 10 % P42 Output frequency detect 6 Hz P43 Output freq. Reverse --- P44 Second accel/decel time 5 sec. P45 Second deceleration time --- P46 Second torque boost --- P47 Second V/F --- P48 Output current level detect 150 % P49 Output current detect delay time 0 sec. P50 Zero current detect level 5 % P51 Zero current detect time 0.5 sec. P52 Control panel display data 0 P53 Frequency set selection 0 P54 FM terminal function select 0 P55 Frequency monitor reference * 50 60 Hz 60 P56 Current monitor reference ** Rated current P57 Restart coasting time --- P58 Restart cushion time 1 sec. P59 Remote set function select 0 P60 RL terminal function select 0 P61 RM terminal function select 1 P62 RH terminal function select 2 P63 STR terminal function select --- P64 RUN terminal function select 0 P65 A,B,C terminal function select 99 11 P66 Retry selection 0 1 P67 Number of retry at alarm 0 1 P68 Retry wait time 1 sec. 2.5 P69 Retry display erase 0 P70 Soft-PWM setting 1 P71 Applied motor 0 P72 PWM frequency select 1 P73 0-5/0-10V select 0 P74 Input filter time constant 1 P75 Reset select 14 P76 Cooling fan operate select 1 P77 Parameter write disable select 0 P78 Reverse rotate select 0 P79 Operation mode select 0 2 * Factory setting determined by EC or non-ec unit. ** The rated current depends on the VFD capacity, either 1.5 kw or.37 kw.

TOP HYDROBOT LIFT AND DESCEND - MINI VISTA, VISTA PLUS, VISTA AND SUPERVISTA Mitsubishi VFD FR-S520.37 kw Parameter Function de scription Factory setting Operational setting P0 Torque boost 6 % 5 P1 Maximum frequency * 50-60 Hz 60 P2 Minimum frequency 0 Hz 50 P3 Base frequency * 50 60 Hz P4 Speed setting (high) * 50 60 Hz 60 P5 Speed setting (middle) 30 Hz 60 P6 Speed setting (low) 10 Hz 50 P7 Acceleration time 5 sec. 0.8 P8 Deceleration time 5 sec. 0.3 P9 Electronic thermal O/L relay **Rated 1.9 current P10 DC brake operation frequency 3 Hz P11 DC brake operation time 0.5 sec P12 DC brake voltage 6 % P13 Starting frequency 0.5 Hz P14 Load pattern selection 0 P15 Jog frequency 5 Hz P16 Jog accel/decel time 0.5 sec. P17 RUN rotation selection 0 P18 P19 Base frequency voltage 888 260 P20 Accel/decel reference freq. * 50-60 Hz 60 P21 Stall prevent function select 0 P22 Stall prevent operate level 150 % P23 Double speed stall prevent --- P24 Speed setting (4) --- P25 Speed setting (5) --- P26 Speed setting (6) --- P27 Speed setting (7) --- P28 Stall prevent reduction freq. * 50 60 Hz P29 Accel/decel pattern 0 P30 Ext. function display select 0 P31 Frequency jump 1A --- P32 Frequency jump 1B --- P33 Frequency jump 2A --- P34 Frequency jump 2B --- P35 Frequency jump 3A --- P36 Frequency jump 3B --- P37 Speed display 0 P38 Frequency voltage gain * 50-60 Hz P39 Frequency current gain * 50-60 Hz

P40 Start time ground fault * 1-0 P41 Frequency sensitivity 10 % P42 Output frequency detect 6 Hz P43 Output freq. Reverse --- P44 Second accel/decel time 5 sec. P45 Second deceleration time --- P46 Second torque boost --- P47 Second V/F --- P48 Output current level detect 150 % P49 Output current detect delay time 0 sec. P50 Zero current detect level 5 % P51 Zero current detect time 0.5 sec. P52 Control panel display data 0 P53 Frequency set selection 0 P54 FM terminal function select 0 P55 Frequency monitor reference * 50 60 Hz 60 P56 Current monitor reference ** Rated current P57 Restart coasting time --- P58 Restart cushion time 1 sec. P59 Remote set function select 0 P60 RL terminal function select 0 P61 RM terminal function select 1 P62 RH terminal function select 2 P63 STR terminal function select --- P64 RUN terminal function select 0 P65 A,B,C terminal function select 99 11 P66 Retry selection 0 1 P67 Number of retry at alarm 0 1 P68 Retry wait time 1 sec. 2.5 P69 Retry display erase 0 P70 Soft-PWM setting 1 P71 Applied motor 0 P72 PWM frequency select 1 P73 0-5/0-10V select 0 P74 Input filter time constant 1 P75 Reset select 14 P76 Cooling fan operate select 1 P77 Parameter write disable select 0 P78 Reverse rotate select 0 P79 Operation mode select 0 2 * Factory setting determined by EC or non-ec unit. ** The rated current depends on the VFD capacity, either 1.5 kw or.37 kw.

TOP HYDROBOT ROTATION MINI VISTA, VISTA PLUS, VISTA AND SUPERVISTA Mitsubishi VFD FR-S520.37 kw Parameter Function description Factory setting Operational setting P0 Torque boost 6 % 5 P1 Maximum frequency * 50-60 Hz 50 P2 Minimum frequency 0 Hz 25 P3 Base frequency * 50 60 Hz P4 Speed setting (high) * 50 60 Hz 50 P5 Speed setting (middle) 30 Hz 50 P6 Speed setting (low) 10 Hz 50 P7 Acceleration time 5 sec. 0.5 P8 Deceleration time 5 sec. 0.5 P9 Electronic thermal O/L relay **Rated 1.9 current P10 DC brake operation frequency 3 Hz P11 DC brake operation time 0.5 sec P12 DC brake voltage 6 % P13 Starting frequency 0.5 Hz P14 Load pattern selection 0 P15 Jog frequency 5 Hz P16 Jog accel/decel time 0.5 sec. P17 RUN rotation selection 0 P18 P19 Base frequency voltage 888 260 P20 Accel/decel reference freq. * 50-60 Hz 60 P21 Stall prevent function select 0 P22 Stall prevent operate level 150 % P23 Double speed stall prevent --- P24 Speed setting (4) --- P25 Speed setting (5) --- P26 Speed setting (6) --- P27 Speed setting (7) --- P28 Stall prevent reduction freq. * 50 60 Hz P29 Accel/decel pattern 0 P30 Ext. function display select 0 P31 Frequency jump 1A --- P32 Frequency jump 1B --- P33 Frequency jump 2A --- P34 Frequency jump 2B --- P35 Frequency jump 3A --- P36 Frequency jump 3B --- P37 Speed display 0 P38 Frequency voltage gain * 50-60 Hz P39 Frequency current gain * 50-60 Hz

P40 Start time ground fault * 1-0 P41 Frequency sensitivity 10 % P42 Output frequency detect 6 Hz P43 Output freq. Reverse --- P44 Second accel/decel time 5 sec. P45 Second deceleration time --- P46 Second torque boost --- P47 Second V/F --- P48 Output current level detect 150 % P49 Output current detect delay time 0 sec. P50 Zero current detect level 5 % P51 Zero current detect time 0.5 sec. P52 Control panel display data 0 P53 Frequency set selection 0 P54 FM terminal function select 0 P55 Frequency monitor reference * 50 60 Hz 60 P56 Current monitor reference ** Rated current P57 Restart coasting time --- P58 Restart cushion time 1 sec. P59 Remote set function select 0 P60 RL terminal function select 0 P61 RM terminal function select 1 P62 RH terminal function select 2 P63 STR terminal function select --- P64 RUN terminal function select 0 P65 A,B,C terminal function select 99 11 P66 Retry selection 0 1 P67 Number of retry at alarm 0 1 P68 Retry wait time 1 sec. 2.5 P69 Retry display erase 0 P70 Soft-PWM setting 1 P71 Applied motor 0 P72 PWM frequency select 1 P73 0-5/0-10V select 0 P74 Input filter time constant 1 P75 Reset select 14 P76 Cooling fan operate select 1 P77 Parameter write disable select 0 P78 Reverse rotate select 0 P79 Operation mode select 0 2 * Factory setting determined by EC or non-ec unit. ** The rated current depends on the VFD capacity, either 1.5 kw or.37 kw.

TOP DRYER LIFT AND DESCEND - MINI VISTA, VISTA PLUS, VISTA AND SUPERVISTA Mitsubishi VFD FR-S520.37 kw Parameter Function description Factory setting Operational setting P0 Torque boost 6 % 5 P1 Maximum frequency * 50-60 Hz 60 P2 Minimum frequency 0 Hz 50 P3 Base frequency * 50 60 Hz P4 Speed setting (high) * 50 60 Hz 60 P5 Speed setting (middle) 30 Hz 50 P6 Speed setting (low) 10 Hz 50 P7 Acceleration time 5 sec. 0.8 P8 Deceleration time 5 sec. 0.3 P9 Electronic thermal O/L relay **Rated 1.9 current P10 DC brake operation frequency 3 Hz P11 DC brake operation time 0.5 sec P12 DC brake voltage 6 % P13 Starting frequency 0.5 Hz P14 Load pattern selection 0 P15 Jog frequency 5 Hz P16 Jog accel/decel time 0.5 sec. P17 RUN rotation selection 0 P18 P19 Base frequency voltage 888 260 P20 Accel/decel reference freq. * 50-60 Hz 60 P21 Stall prevent function select 0 P22 Stall prevent operate level 150 % P23 Double speed stall prevent --- P24 Speed setting (4) --- P25 Speed setting (5) --- P26 Speed setting (6) --- P27 Speed setting (7) --- P28 Stall prevent reduction freq. * 50 60 Hz P29 Accel/decel pattern 0 P30 Ext. function display select 0 P31 Frequency jump 1A --- P32 Frequency jump 1B --- P33 Frequency jump 2A --- P34 Frequency jump 2B --- P35 Frequency jump 3A --- P36 Frequency jump 3B --- P37 Speed display 0 P38 Frequency voltage gain * 50-60 Hz P39 Frequency current gain * 50-60 Hz

P40 Start time ground fault * 1-0 P41 Frequency sensitivity 10 % P42 Output frequency detect 6 Hz P43 Output freq. Reverse --- P44 Second accel/decel time 5 sec. P45 Second deceleration time --- P46 Second torque boost --- P47 Second V/F --- P48 Output current level detect 150 % P49 Output current detect delay time 0 sec. P50 Zero current detect level 5 % P51 Zero current detect time 0.5 sec. P52 Control panel display data 0 P53 Frequency set selection 0 P54 FM terminal function select 0 P55 Frequency monitor reference * 50 60 Hz 60 P56 Current monitor reference ** Rated current P57 Restart coasting time --- P58 Restart cushion time 1 sec. P59 Remote set function select 0 P60 RL terminal function select 0 P61 RM terminal function select 1 P62 RH terminal function select 2 P63 STR terminal function select --- P64 RUN terminal function select 0 P65 A,B,C terminal function select 99 11 P66 Retry selection 0 1 P67 Number of retry at alarm 0 1 P68 Retry wait time 1 sec. 2.5 P69 Retry display erase 0 P70 Soft-PWM setting 1 P71 Applied motor 0 P72 PWM frequency select 1 P73 0-5/0-10V select 0 P74 Input filter time constant 1 P75 Reset select 14 P76 Cooling fan operate select 1 P77 Parameter write disable select 0 P78 Reverse rotate select 0 P79 Operation mode select 0 2 * Factory setting determined by EC or non-ec unit. ** The rated current depends on the VFD capacity, either 1.5 kw or.37 kw.

VERTICAL FOLLOWING SIDE BRUSH CART - SUPERVISTA Mitsubishi VFD FR-S520.37 kw Parameter Function description Factory setting Operational setting P0 Torque boost 6 % 5 P1 Maximum frequency * 50-60 Hz 80 P2 Minimum frequency 0 Hz 30 P3 Base frequency * 50 60 Hz P4 Speed setting (high) * 50 60 Hz 50 P5 Speed setting (middle) 30 Hz 45 P6 Speed setting (low) 10 Hz 40 P7 Acceleration time 5 sec. 0.6 P8 Deceleration time 5 sec. 0.3 P9 Electronic thermal O/L relay **Rated 1.9 current P10 DC brake operation frequency 3 Hz P11 DC brake operation time 0.5 sec P12 DC brake voltage 6 % P13 Starting frequency 0.5 Hz P14 Load pattern selection 0 P15 Jog frequency 5 Hz P16 Jog accel/decel time 0.5 sec. P17 RUN rotation selection 0 P18 P19 Base frequency voltage 888 260 P20 Accel/decel reference freq. * 50-60 Hz 60 P21 Stall prevent function select 0 P22 Stall prevent operate level 150 % P23 Double speed stall prevent --- P24 Speed setting (4) --- P25 Speed setting (5) --- P26 Speed setting (6) --- P27 Speed setting (7) --- P28 Stall prevent reduction freq. * 50 60 Hz P29 Accel/decel pattern 0 P30 Ext. function display select 0 P31 Frequency jump 1A --- P32 Frequency jump 1B --- P33 Frequency jump 2A --- P34 Frequency jump 2B --- P35 Frequency jump 3A --- P36 Frequency jump 3B --- P37 Speed display 0 P38 Frequency voltage gain * 50-60 Hz P39 Frequency current gain * 50-60 Hz

P40 Start time ground fault * 1-0 P41 Frequency sensitivity 10 % P42 Output frequency detect 6 Hz P43 Output freq. Reverse --- P44 Second accel/decel time 5 sec. 6 P45 Second deceleration time --- P46 Second torque boost --- P47 Second V/F --- P48 Output current level detect 150 % P49 Output current detect delay time 0 sec. P50 Zero current detect level 5 % P51 Zero current detect time 0.5 sec. P52 Control panel display data 0 P53 Frequency set selection 0 P54 FM terminal function select 0 P55 Frequency monitor reference * 50 60 Hz 60 P56 Current monitor reference ** Rated current P57 Restart coasting time --- P58 Restart cushion time 1 sec. P59 Remote set function select 0 P60 RL terminal function select 0 P61 RM terminal function select 1 P62 RH terminal function select 2 P63 STR terminal function select --- P64 RUN terminal function select 0 P65 A,B,C terminal function select 99 11 P66 Retry selection 0 1 P67 Number of retry at alarm 0 1 P68 Retry wait time 1 sec. 2.5 P69 Retry display erase 0 P70 Soft-PWM setting 1 P71 Applied motor 0 P72 PWM frequency select 1 P73 0-5/0-10V select 0 P74 Input filter time constant 1 P75 Reset select 14 P76 Cooling fan operate select 1 P77 Parameter write disable select 0 P78 Reverse rotate select 0 P79 Operation mode select 0 2 * Factory setting determined by EC or non-ec unit. The EC setting is shown first. ** The rated current depends on the VFD capacity, either 1.5 kw or.37 kw.