INPUT/OUTPUT SPECIFICATIONS FOR CONTROL DATA TeleProgrammer

Similar documents
The Lincoln TX-2 Input-Output System*

EBU INTERFACES FOR 625 LINE DIGITAL VIDEO SIGNALS AT THE 4:2:2 LEVEL OF CCIR RECOMMENDATION 601 CONTENTS

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

DMX 512 Language Date: Venerdì, febbraio 12:15:08 CET Topic: Educational Lighting Site

KW11-L line time clock manual

LavryBlack Series Model DA10 Digital to Analog Converter

SMPTE STANDARD Gb/s Signal/Data Serial Interface. Proposed SMPTE Standard for Television SMPTE 424M Date: < > TP Rev 0

This Errata Sheet contains corrections or changes made after the publication of this manual.

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

AI-1204Z-PCI. Features. 10MSPS, 12-bit Analog Input Board for PCI AI-1204Z-PCI 1. Ver.1.04

Experiment # 4 Counters and Logic Analyzer

SignalTap Plus System Analyzer

Computer Systems Architecture

SDA 3302 Family. GHz PLL with I 2 C Bus and Four Chip Addresses

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

Chapter 7 Memory and Programmable Logic

THE KENYA POLYTECHNIC

PDW MARTHEL S.C. ul. Sosnowa 24-5, Bielany Wrocławskie Kobierzyce, POLAND tel , 12; fax MART-02:

CM-1UTP CAMERA MASTER UTP ADAPTOR

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

CCD-TR57/TR67/TR87/TR413PK/TR414PK/ TR917/TR940/TR940PK

The outputs are formed by a combinational logic function of the inputs to the circuit or the values stored in the flip-flops (or both).

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

S6B CH SEGMENT DRIVER FOR DOT MATRIX LCD

Specification of interfaces for 625 line digital PAL signals CONTENTS

PRESET TEN ARCHITECTURAL TWO OWNERS MANUAL

HMC958LC5 HIGH SPEED LOGIC - SMT. Typical Applications. Features. Functional Diagram. General Description

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

C200H-AD002/DA002 Analog I/O Units Operation Guide

PRESET 10 ARCHITECTURAL OWNERS MANUAL

AN ABSTRACT OF THE THESIS OF. Title: DESIGN OF HIGH SPEED PAPER TAPE READER INTERFACE

Video Accessory IC Series Sync Separation ICs with Built-in AFC BA7046F, BA7071F Rev.A 1/9

SEQUENTIAL LOGIC. Satish Chandra Assistant Professor Department of Physics P P N College, Kanpur

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Exercise 2-1. External Call Answering and Termination EXERCISE OBJECTIVE

Report on 4-bit Counter design Report- 1, 2. Report on D- Flipflop. Course project for ECE533

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

Performing Signal Integrity Analyses

Chapter 4. Logic Design

PRESET TEN ARCHITECTURAL TWO OWNERS MANUAL

A MISSILE INSTRUMENTATION ENCODER

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

82C55A CHMOS PROGRAMMABLE PERIPHERAL INTERFACE


PRESET 10 PORTABLE OWNERS MANUAL

FLIP-FLOPS AND RELATED DEVICES

KW11-L line time clock manual

Addendum to the AOMI Manual

WINTER 14 EXAMINATION

Build A Video Switcher

WINTER 15 EXAMINATION Model Answer

ECE 372 Microcontroller Design

Stevens SatComm FAQs For use with SatCommSet or Terminal Setup programs

Laboratory 9 Digital Circuits: Flip Flops, One-Shot, Shift Register, Ripple Counter

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Sequential Logic Basics

Chapter 6. sequential logic design. This is the beginning of the second part of this course, sequential logic.

Exercise 1-2. Digital Trunk Interface EXERCISE OBJECTIVE

LAX_x Logic Analyzer

PESIT Bangalore South Campus

MclNTOSH MODEL C-4 and C-4P

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Design Project: Designing a Viterbi Decoder (PART I)

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio

Combinational vs Sequential

64CH SEGMENT DRIVER FOR DOT MATRIX LCD

UNIT V 8051 Microcontroller based Systems Design

Sequencing. Lan-Da Van ( 范倫達 ), Ph. D. Department of Computer Science National Chiao Tung University Taiwan, R.O.C. Fall,

Installation and Operation Manual

Netzer AqBiSS Electric Encoders

16 Stage Bi-Directional LED Sequencer

DEC BUILDING BLOCK LOGIC

DIGITAL ELECTRONICS: LOGIC AND CLOCKS

BNC-2110 DESKTOP AND DIN RAIL-MOUNTABLE BNC ADAPTER

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Chapter 5 Flip-Flops and Related Devices

UNIT III COMBINATIONAL AND SEQUENTIAL CIRCUIT DESIGN

Final Exam review: chapter 4 and 5. Supplement 3 and 4

Model /29S RF Splitter

OWNERS MANUAL LUNATEC V3 MICROPHONE PREAMPLIFIER AND A/D CONVERTER

AI-1616L-LPE. Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE 1. Ver.1.02 Ver.1.01

Connection Guide of the MOTOTRBO radio to the radioserver as a control station

SingMai Electronics SM06. Advanced Composite Video Interface: HD-SDI to acvi converter module. User Manual. Revision 0.

Technical data. General specifications. Indicators/operating means

QRF5000 MDU ENCODER. Data Sheet

AC103/AT103 ANALOG & DIGITAL ELECTRONICS JUN 2015

BUSES IN COMPUTER ARCHITECTURE

3M 8900 Single-mode SC Crimplok Connector

Instrumental technique. BNC connector

2 The Essentials of Binary Arithmetic

ASNT_PRBS20B_1 18Gbps PRBS7/15 Generator Featuring Jitter Insertion, Selectable Sync, and Output Amplitude Control

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

NI-DAQmx Device Considerations

AOM4 Programmable Excitation Module

University of Victoria. Department of Electrical and Computer Engineering. CENG 290 Digital Design I Lab Manual

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

Transcription:

INPUT/OUTPUT SPECIFICATIONS FOR CONTROL DATA 8092 TeleProgrammer

INPUT/OUTPUT SPECIFICATIONS FOR CONTROL DATA 8092 TeleProgrammer lop 105a

REVISION A 3/11/64 Manual printed. REVISION RECORD DESCRIPTION Publication No. 36810500A - 1964 by Control Data Corporation Printed in the United States of America Address comments concerning this manual to: Control Data Corporation Technical Publications 4201 N. Lexington Ave. St. Paul, Minnesota 55112. or use Comment Sheet in the back of this manual..

CONTENTS TELEPROGRAMMER INPUT/OUTPUT SPECIFICATIONS 1 Page Interrupt 2 Select Codes 3 Communication Lines 7 Normal Input/Output 10 Buffered Input/Output 13 TELEPROGRAMMER COMMUNICATION CIRCUITS 19 Input Circuits 19 Output Circuits 20 Cable Connectors 22 FIGURES 1 8092 TeleProgrammer (Photograph) IV 2 Block Diagram 8092 TeleProgrammer System 2 3 Normal Input 8092 12 4 Normal Output 8092 12 Sa Buffered Input 8092 15 5b Buffered Output 8092 15 6 Maximul1) PE?rmissible Transfer Rates Using Buffer Channel 16 7 Input Amplifier Circuit 20 8 Output Amplifier Circuit 22 TABLES 1 Communication Lines, Output Cable 2 Communication Lines, Input Cable 3 Cable Designations 4 Pin Assignments 5 6 7 9 111

-- ~ \.,~_J!... - '"!,\._.L J. 7~- J l - - j!j. - J. "'~::'ij- )!L_.t J. J "".~:....0 Figure 1-8092 TeleProgrammer IV

The input/output (I/O) specific ations for the CO N TRO L DA T A* 8092 TeleProgl'arnmer apply to all device9 which connect with the TelePrograrnmer. This specification is written to allow a minimum data exchange time consistent with accepted engineering practices and moderate hardware requirements. The 8092 has a four-level interrupt and a buffered I/O. The latter permits the TelePrograrnmer to continue high-speed computation while communicating with external equipment. The minimum system may be expanded to include the following external equipment: Additional magnetic tape stations I/O typewriters Punched card readers, punches, arid low speed line printers High speed printers - 1000 lines/minute Plotting and digital display equipment Analog to digital and digital to analog equipment Two or more CONTROL DATA TelePrograrnmers operating in a satellite- system All information is measured as binary "1" and "0" voltage levels, nominal ground level (-0.5v) constituting a "1", and -16v a "0".:>',0:< Voltage is measured at the output terminals of the TelePrograrnmer and the external equipment. * Registered Trademark of Control Data Corporation ** See page 18 for tolel"ances on these voltage levels. 1

INTERRUPT Certain internal and external conditions arise which make it desirable for the main program to be notified of their presence. An interrupt is the program signal which transfers computer control to some fixed location in memory without losing the information needed to return to the main program. Z REGISTER -'"'" NORMAL INPUT S r? BFR BUSY NORMAL OUTPUT. r-i I--3 S )- BFR BUSY BUFFER../ ~. BUFFER.'-.. BUFFER INPUT UNES,. REGISTE"R T OUTPUT S INPUT.BUFFER ACTIVE ~ OUTPUT BUFFER ACTIVE Figure 2 8092 Input/Output System 2

The 8092 has four interrupt lines: two internal, 10 and 20, and two external, 30 and 40. When an external equipment generates an interrupt the TeleProgrammer may enter the interrupt routine if the interrupt lockout is not on. The TeleProgrammer program may send a status request to all equipment which might have generated the interrupt to determine which interrupted. This status request is a signal to the external equipment to turn off the interrupt, or the signal in the external device may be turned off by a function response. SELECT CODES The TeleProgrammer selects the external equipment for I/O operation by the use of select code~. The I/O operation is initiated by a 75 instruction which selects a 12-bit code and places it on the output lines with a function ready signal. The upper 6 master bits (unit designator) select the external equipment, and the lower 6 bits (function designatgr) designate the function. Master bits for select codes must be umque for each 8092 I/O equipment. Master bits given below are in octal and quartic (base 4) notation, and represent devices currently available. It. is recommended that the 8092 Engineering Department of Control Data Corporation be consulted before assigning master bits for select codes on new equipment. This will minimize the chance of select code duplication through future expansion of an existing system. 3

SELECT CODE ASSIGNMENTS Octal Code 07 11 12 13 10 11 12 13 30 35 36 41 42 43 45 53 63 01XX 02XX Equipment 166-2 Printer (with 8294 adaptor) 162 Mag. Tape Systems {6-bit transfer) 8293 Mag. Tape Synchronizer 170 Card Punch Control Unit 8295 Records Transmission Control Panel 8061, 8062, 8064, 8065 OCT Reader and Punch 161 Typewriter or Model 33 Page Printer 167-2 and 177 Card Readers Exchange Unit (with 8294 adaptor) 8294 Peripheral Equipment Adaptor 8155 Multiplexer 4

TABLE 1. COMMUNICATION S Output Cable TELEPROGRAMMER TO EXTERNAL EQUIPMENT External Master Clear Static "1 I' signal appears on the line (Pin U) whenever Load/Clear switch at 8092 console is set to Clear. Signal IS available to clear external equipment attached to the TeleProgrammer. Function Ready (Pin T) Information Ready (Pin R) Static "1" signal is produced on the line when external function code is present on output data lines for examination and translation by external equipment. Signal IS removed by output resume signal from external equipment. Static "1" signal accompanies each word of output inform ation. Signal IS turned off by output resume signal from external equipm ent. EXTERNAL EQUIPMENT TO TELEPROGRAMMER Output Resume Static "1" indicates external equipment (Pin S) has accepted word of information or external function code. Signal turns off information ready or function ready signal at Tel~Programmer. Output resume drops when function ready or information ready drops. Interrupt 30, 40 (Pins, Y, Z) Static "1" signal notifies 8092 that interrupt is generated. 8092 enters interrupt routine and sends status request code which signifies that the interrupt should be turned off. OUTPUT DATA AND EXTERNAL FUNCTION S (Pins A,B,C,D,E,F,H,J,K,L,M, The 8 lines which carry output data and N) information when. accompanied by information ready. signal, output word from 8092. External equipment samples these lines to ready the output word. The 12 lines which carry external function information when accompanied by function ready signal, hold EF code which selects operational mode within external equipment. ' 5

TABLE 2. COMMUNICATION S Input Cable TeleProgrammer to External Equipment Input Request (Pin S) External Equipment to TeleProgrammer Input Ready (Pin R) Disconnect (Pin V) Input Data and Status Lines (Pins A,B,C,D,E,F,H, J) Static "1" signal is produced when TeleProgrammer IS ready to receive an input word. Signal drops on receipt of input ready signal. Static "1" signal produced when information, In a state which Teleprogrammer may sample, is present in input register of external equipment. Signal IS dropped when TeleProgrammer drops input request signal. Static "1" signal is produced when input device has transmitted final word of input data and the Tele Programmer transmits an additional Input Request. Upon receipt of signal, TelePrograminer drops Input Request and resumes main program with no further delay. Signal is dropped when TeleProgrammer drops input request signal. ( Generally, input instruction establishes a storage field of greater capacity than the anticipated input data block.) The 8 lines which carry input data and status information perform as follows: 1) Following a normal input mode selection, lines hold content of external equipment input r.egister which TeleProgrammer samples. Data is removed from lines when input request is dropped from TeleProgrammer. 2) Following request for status from TeleProgrammer, lines contain external equipment response. (Input instruction is programmed to ascertain status response. ) 6

TABLE 3. CABLE DESIGNATIONS 8092 INPUT/OUTPUT EQUIPMENT Cable Number" Input Cable Output Cable Buffer Input Cable Buffer Output Cable J01 J03 J02 J04 J05 J07 J06 J08 COMMUNICATION S Of the four communication cables between the TeleProgrammer and all external equipment, two carry normal I/O signals and two carry buffer I/O signals. Each input cable contains 8 data lines plus various control lines, and each has two connectors. Each output cable contains 12 data lines (i.e. 12 for EF and 8 for data) and various control lines and each has two connectors. C abies from external equipment enter the TeleProgrammer through the rectangular opening in the bottom. The front door of the TeleProgrammer permits access to jack locations found on the lower portion of the m"ain chassis. (Jack numbers for I/O lines are given in table 3.) Every external unit must be connected to the output cable because the external function code (carried on data lines of output cable) must be available to both input and output devices. 7

The total number of devices attached to one line is limited by maximum cable length and power capacities of the transistors on the amplifier cards. Five pieces of equipment may be attached to the normal channel. and five to the buffer channel. Equipment attached to the buffer lines may be addressed directly if no buffer operation IS in progress. Consequently anyone of up to ten external pieces of equipment may be addressed by normal I/O if the buffer is not busy. 8

TABLE 4. PIN ASSIGNMENTS, INPUT/OUTPUT CABLES Normal Input and Buffer Input Cable Pin Normal Output and Buffer Output Cable BitO 1 2 3 4 5 6 7 input status and information A B C D E F H J K L M N P Bit o output fup.ction and information 1 2 3 4 ~ Data 5 6 :> External 7... Function 8 9 10 11 Input Ready Input Request Disconnect I/O sequence} Used by Paper Tape Load Mode Reader Only Ground R S T U V W X Y Z a b Information Ready Output Resume Function Ready Master Clear Interrupt 30 Interrupt 40 Ground 9

NORMAL INPUT/OUTPUT Sequence of Events in Normal Input (Refer to figure 3) 1. The TeleProgrammer executes, a 75 instruction and sends out an external function code (EF), together with a function ready signal to select external equipment. The time required for initiating the EF code is 12 usec. 2. The external equipment receives the EF code at its own rate, and sends back an output resume, turning off the function ready signal. (Termination of the function ready signal in the Teleprogrammer must turn off the output resume in the external equipment within 4 usec.) 3. The TeleProgrammer takes 12 usec. to set up the input instruction (72), after which an input request signal is issued. 4. The external equipment accepts the input request signal, places a word on the data lines, and returns an input ready signal which turns off the input request in the TeleProgrammer. The external equipment delivers the word to the TeleProgrammer at its own rate. (Termination of the input request signal must turn off the input ready signal in the external device within 4 usec.) When the TeleProgrammer receives an input ready signal, it initiates a store sequence and issues another input request if more information is desired. Steps 3 and 4 repeat until the last word is received in the TeleProgrammer. Termination 10

of data input may originate in the TeleProgrammer through failure to issue an input request or in the external equipment through an input disconnect. Sequence of Events in Normal Output (Refer to figure 4) 1. Same as normal input. 2. Same as normal input. 3. In 16 usec, the TeleProgrammer sets up the output instruction and delivers the first word to the data lines along with an information ready signal to indicate that data is available to the external equipment. 4. The external equipment recognizes the information ready signal after a 2 usec. delay, stores the data at its own rate, and returns an output resume signal to the TeleProgrammer. 5. The TeleProgrammer accepts the output resume signal and turns off the information ready signal. Termination of the information ready signal must turn off the output resume In the external equipment within 4 usec. At that time, the TeleProgrammer reads another word In 8 usec., generates an information ready signal, and repeats step 4 until all words are transferred into the external equipment. Transfer of output data is terminated by failure of the TeleProgrammer to issue an information ready signal. 11

FUNCTION REAOY ' OUTPUT * RESUME INPUT REQUEST INPUT READY INPUT REQUESt (WORD 2) INPUT READY r-- 2 1'0' delay due to H card lag - 12 p.s--i ( :+: ~~c~~~t. f i I ExternaL equipmel)t receives I L... EF code and sends Resume : ~----~~r--~----~rnl-------~r_------~------------- '1 " -- '-17 p.s--i : Set up input, I instruction i JJ This sequence of events repeats until no more input requests are issuen,dbc sequence Equipment recop,nize, input request : and delivers word (accompanied by I Input Ready) at own'rate ~ f----;l'--- ~I--------'------ 8 f's to store first! word S'C' ~equence ':L I, I, ~--~!.'~f------~~-----------------------------~ Figure 3. Nor~al Input B092 releprogrammer INFO READY,, 1 1 Lli p.s set up outpllt, instruction and I I ODCe i deliver word 1 OUTPUT RESUME INFO' READY ~------~Jrt--------------------------------------~-----J 12.8p.S Read word 2 B'C'sequence ~~~~~~~~~~ Word "2 and all after,------------------~----------~ Store tl Figure 4. Normal Output B092 TeleProgrammer * Signals generated by external equipment 12

BUFFERED INPUT/OUTPUT Sequence of Events in Buffered Input {Refer to figure Sa} 1. Same as normal input. 2. Same as normal input. 3. The TeleProgrammer reads the 70 instruction in 4 usee. It then generates an input request, releasing the TeleProgrammer for computation. 4. The external equipment accepts the input request signal, places a word on the data lines, and generates an input ready signal. S. The TeleProgrammer accepts the input ready signal and stores the word. ':' Recognition of the input ready signal terminates the input request which turns off the input ready signal in the external equipment. {Termination of the input request signal must turn off the input ready signal within 4 msec.} 6. The TeleProgrammer Issues another input request and steps 4 and S repeat until all words are buffered into the TeleProgrammer. Sequence of Events in Buffered Output {Refer to figure" Sb} 1. Same as normal input. ':' It may take the TeleProgrammer up to 18 usec. to recognize the input ready and store the word, depending on which cycle the TeleProgrammer is in when the input ready signal occurs. 13

2. Same as normal input. 3. The TeleProgrammer reads the 71 instruction in 4 usec. and initiates a buffer cycle to place the first word on the data lines and issue an information ready signal. The Tele- Programmer is then free for computation. 4. The external equipment accepts the information ready signal and data at its own rate and returns an output resume signal. 5. Recognition of the output resume signal initiates another buffer cycle and terminates the information rea?y signal. * 6. Termination of the information ready signal in the TeleProgrammer turns off the output resume signal in external equipment. (Output resume must turn off within 4 msec.) 7. Steps 3-5 are repeated for each word until all words are buffered out of the TeleProgrammer. * It may take the TeleProgrammer up to 18 usec. to recognize the output resume and put the next word on the output lines, depending on which cycle the TeleProgrammer is in when the output resume occurs. 14

FUNCTION READY OUTPUT.. RESUME INPUT REQUEST INPUT " READV INPUT REClUEST INPUT.. READY 12 P.s 7S instructionl or.-- ~ ;.----1 ~r ---:--'v.,r--- 2J.l.s delay due to M card lap, Dec' sequence 1.IJ I I I L+J--------~------------------------------- I, I l :ea/i r- ~~r-------~r-l 70.JJ : 4 slset Buffer FF and I ~ I for computation release 8082 rw_o_r_d_l!~~ I---/~~ r n r---------~j/~-------------~~i I I I "lord 2 : L-.. I,lSJ.l.S max. 6 J.l.s min. n ~-----~JJ~/----------------------------~--~-------~ ~----- Figure Sa. Buffered Input, 8092 TeleProgrammer INFO READY I.lNE OUTPUT". RESUME WOTd I ~ I.: I INFO I Word 2 REAOY. c 18J4!1!'lax. OUTPUT 6 JLs min. RESUME ( J n n I I,., Figure Sb. Buffered Output, 8092 TeleProgramnier * Signals generated by external equipment 15

o MAl(. BFR SP ED, COMPUTER HI.ftG li' 10.3 WltCYCL[ 28.3 11.33 11,3311.33 11.3<>1' e"" CYCLE 4> I 4 a 0 CAfiODElAV IWI~ I f INITIATE II AnY/MQUEST TO EXTDWAL. EQUlPIIIE!fT 4,0... ~.1.33 T ~A. f RVJIT /II SIJtIE 'ROM EX1DIIW. ~A"'JYES AT TELE'PROGRAMMER l'obk' CD MAX. BFR SPEED, PflOGRAM WITHOUT A a B CYCLES 12.0)JSEC BP1tCYCLE PROOftN' CYCLE PRoeM"" CYCLE 4.0 I 4.0 I 4.0 3.83 11 3 11.3 11.311.3 I 0 a CARD DELAY t ~~ I 5.0 MAX. IWI~ BUfFER WAITS an cycle 4.0 I I 83KC - Sampling of incoming signals occurs at 1.33 Jlsec intervals during all machine cycles. * This resync period may start earlier with a shorter card delay (at previous sample time ';0"). Figure 6 Maximum Permissible Transfer Rates Using:Buffer Channel 16

TELEPROGRAMMER COMMUNICATION CIRCUITS 17

TELEPROGRAMMER COMMUNICATION CIRCUITS In communicating with external devices the TeleProgrammer signals undergo a level change to minimize effects of cable impedance. The TelePrograrnmer signals are refepred to as logic levels, the cable signals as line levels. The binary representation for the two levels are: Logic Line "1" -3.0v (± 0.2Sv) "0" -O.Sv (± 0.2Sv) "1" -O.Sv (+ 0.2Sv»:' "0" -16v (± 2.Sv) Both line and logic levels are encountered in the input and output amplifier cards. 1 All external equipment control signals are resyn- chronized upon entering the TeleProgrammer. INPUT CIRCUITS In the schematic diagram of the input amplifier circuit (figure 7), resistor R01 and the -20v supply hold the input to the circuit (point a) to line 110" when no input signal is supplied, or when no data or control line is tied to the circuit. If a line 11111 is supplied to the input pin, the base of Q01 (point b) rises due to the voltage divider action of R02, R06, and ROB. Subsequently 001 stops conducting, and the output to the computer circuits represents a logic 11111. ):~ Tolerances given are for Control Data equipment. When other equipment is connected to Control Data TeleProgrammers, the following variation may be tolerated on the "1" line level: + O. Sv, -2. Sv. 19

Conversely, if a line "0" is applied to the circuit, 001 conducts and the output to the computer circuits approaches -0.5v (logic "0"). Stated simply, the input amplifier inverts the signal electrically, but not logically. -20V TP ROI 2200 RO. 2200 INPUT RO. (a) 6800 CROI ROC 1000 R03 IzOo CR04 ROe CR02 CR03 TO COMPUTER LOGIC 220 R07 22000 +2OV -= Figurl3 7. Input Amplifier Circuit Maximum steady-state current drawn by an input amplifier circuit does not exceed 10 rna. If the wire to the input pin is disconnected, the effect is as though a line "0" were present continually. The current waveform has a slope which does not exceed 5 rna per usec. OUTPUT CIRCUITS In the output amplifier circuit (figure 8), resistor ROl and the -20v supply hold the input to the circuit (Point a) at a logic "1" when no signal is applied, or when no data or control line is tied to the clrcuit. The collector of transistor 001 IS connected to its base through a 150uuf capacitor (COl) which integrates this output of 001. 20

When a logic 111" is applied to either input pin, aol turns on, placing a low impedance between ground and the output line. C apacitor COl tends to oppose the initial conduction of QOl by feeding back a signal less positive than that initially placed on the base. When COl is fully charged, 001 reaches full conduction and the output rises to -0. Sv (line "1 II}. If a logic "0" is applied to this circuit, the voltage divider action of the circuit turns off Q01, and the output stabilizes at -16v (line 110 11 ). Stated simply, the output amplifier inverts the signal electrically, but not logically. The output amplifier need supply no more than IO rna to any input amplifier in another piece of equipment. Transition time of the signal waveform from the output amplifier circuit is 2 usec. minimum, 4 usec. maximum. Total line capacity may vary between 0 and 0.002 ufo Voltage level rise and fall rates are Bv/usec.; d-c resistance of cable ground return must not exceed O. 5 ohm. All data lines are stable before information is sampled. 21

-20V -20V TP "ROM (a) ROI 6800 CROI I COMPUTER LOGIC _2OV f.~~ I I 1 0---... *- CR02 ROll 1000 R04 12000 + 20V - - OUTPUT Figure 8. Output Amplifier Circuit CABLE CONNECTORS All data and signal connections between the 8092 TeleProgrammer and peripheral equipment are made using 24-pin Amphenol twistlock connectors. The Amphenol part numbers are given for the male (p) connectors used on all cable ends and the female (S) connectors used for panel mounting. 67-06P-18-24P (cable) 67-02E-18-24S (panel) 22

CABLE CONNECTORS All data and signal connections between the 8092 TeleProgrammer and peripheral equip~ent are made using 24-pin Amphenol twist-lock connectors. The Amphenol part numbers are given for the male (P) connectors used on all cable ends and the female (S) connectors used for panel mounting. 67-06P-l8-24p 67-02E-l8-24S (cable) (panel) 23

COMMENT SHEET MANUAL TITLE 8_0_9_2_T_e_l_e_P_r_o-,g",-r_a_m_m_e_r_I_n... p,-u_t...;..l_o_u_t... p... u_t_s"'-p_e_c_if_i_c_a_t_io_n_s PUBLICATION NO. 3_6_8_1_0_5_0_0 REVISION A FROM: NAME: BUSINESS ADDRESS: COMMENTS: This form is not intended to be used as an order blank. Your evaluation of this manual will be welcomed by Control Data Corporation. Any errors, suggested additions or deletions, or general comments may be made below. Please include page number references and fill in publication revision level as shown by the last entry on the Record of Revision page at the tront of the manual. Customer engineers are urged to use the TAR. NO POSTAGE STAMP NECESSARY IF MAILED IN U. S. A. FOLD ON DOTTED S AND STAPLE

STAPLE STAPLE FOLD FOLD --------------------------------~ FIRST CLASS PERMIT NO. 8241 MINNEAPOLIS, MINN. BUSINESS REPLY MAIL NO POSTAGE STAMP NECESSARY IF MAILED IN U.S.A. POSTAGE WILL BE PAID BY CONTROL DATA CORPORATION Technical Publications 4201 N. Lexington Ave. St. Paul, Minnesota 55112 AI 'ii 1M 4 w Z :::; C> Z o -' «to :::l U FOLD FOLD

iili::;t. :l.' n.';';;';{'".,.. ;;'; :"t. t.?.. ;';.! "" ~ :!: ~ r::::::::::{%:::::::::::::::::::::,i:::,t:::::::;:::::::::::::{{,:,::f::f:'::f:'f:::':':::ffffffff'ff::t:::f:.t.,:ii.»> CUT OUT FOR USE AS loose -LEAF BINDER TITLE TAB CONTROL DATA CORPORATION 8100 34th AVE. SO., MINNEAPOLIS, MINN. 55440 LITHO IN U.S.A.