Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Similar documents
Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Anvil Theatre. Technical Information

Technical Specifications and Inventory Spring 2018

Technical Specifications

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Arcadia Performing Arts Center Technical Specifications and Information

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

Sandusky State Theatre Technical Specifications

Marjorie S. Deane Little Theater

Concert Hall Technical Specifications

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Services and Specification

Technical Specifications. Taylor Little Theater

Technical Specifications

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

SHUBERT THEATER 247 College Street, New Haven, CT

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Concert Hall Technical Specifications

Patriots Theater at the War Memorial Technical Data

RPAC REDLANDS PERFORMING ARTS CENTRE

Main House Technical Specification

Technical Specifications

Dr JOHN GALLAGHER CONCERT CHAMBER

Technical Information

Technical Specifications

P.O Box 1171 Box Office & Theatre: (903) Main St Texarkana, TX TRAHC Office: (903) Texarkana, TX Fax: (903)

General & Technical Specifications

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

Dale F. Halton Theater Technical Specifications

Technical Specifications

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

Technical Information

Downtown Arts Center Tech Packet. General Information

Technical Specifications

General & Technical Specifications:

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

TECHNICAL PACKAGE.

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

The ACT Facility Technical Specifications Main Stage Information

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

SAINT ANSELM COLLEGE DANA CENTER

Bloomington Center for the Performing Arts. Technical Specifications

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

The Haymarket Basingstoke Technical Specifications

Theatre Technical Specifications

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

Camden Opera House Theater. Technical Information

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

NORTH CHARLESTON PERFORMING ARTS

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Performing Arts Theatre

Quick-Advance Fact Sheet

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

Theatre Technical Specifications

Technical Data Sheet

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013

Jane Mallet Theatre Technical Specifications

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

Matt Dann Cultural Centre

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

Technical Informa on.zack Theater

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Theatre Technical Specification

Facility Information

NORTH CHARLESTON PERFORMING ARTS

Technical Specification for the Alley Theatre, Strabane

The Breen Center for the Performing Arts Saint Ignatius High School

Main Stage Technical Specs - Hall #2

Technical Specifications

TECHNICAL SPECIFICATIONS

New Theatre Royal Lincoln Technical Information

DEREHAM MEMORIAL HALL

TECHNICAL SPECIFICATIONS AND INVENTORY PANTAGES THEATER

Access to back stage is off Fletcher St on the eastern side of the building

Melrose Veteran s Memorial Middle School Auditorium 250 Lynn Fells Parkway, Melrose, MA, 02176

Dr. Fred Speckeen Theatre. Information and Technical Specifications

THE BELDING THEATER. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Center Theater Technical Information 9/1/12

Smothers Theatre Rental Technical Specifications

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

ISLAND HALL TECHNICAL INFORMATION

TECHNICAL INFORMATION

HORIZON STAGE TECH PACKAGE September 2018

UNIVERSITY CONCERT HALL. Technical Specification

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Transcription:

Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface with hard crossover along upstage wall - Proscenium width: 39'-10" - Proscenium height: 20' - Width of stage: 79'-9" (including wing space) - SR wing width: 15'--- SL wing width: 24'-6" (Wings measured from edge of Prosc. to offstage wall / pin rail) - Usable depth: 30' - Height of Stage: 40" from orchestra pit floor - Orchestra Pit: 14' at widest depth (at Centre) 38' at widest length - Note: No screwing, nailing, painting stage surface. Dressing Rooms - Under the stage, with easy access to outside and to Stage Left. There is NO wheelchair access to the dressing rooms. - Max 84 Person capacity - Two water-closets with toilet and sink - Four 4-person dressing rooms with sink (10sq. meters) - Two water-closets with 2 toilets and sink - Two 8-person dressing rooms with double sinks (33.2 sq. meters) - All dressing rooms are equipped with mirrors and make-up lights - Each room, plus common area have program sound - Limited Wi-Fi connection in dressing rooms Loading Bay - Stage: Truck height loading dock (3'-6") - Truck access: 48' long (with a 16' overhang to street) by 21' wide - Loading dock: 26' wide by 19' deep - Access ramp: 4' wide (runs perpendicular to loading dock) - Exterior Loading door: 6'-11" wide by 14'-10" high - (90 degrees to loading dock). 1 P a g e

- Interior Loading door: 5'2" x 14'10" - House: Ramp along house-right exit (via backstage) - Ramp access through lobby. Rigging - All pipe battens are Hemp/ Multiline II line sets - Grid - 47' high wooden grid (unrated) - 4 electrics (1st dead hung, 2nd, 3rd & 4th on winches) - 17 Multiline II/ hemp line sets (max 250 lbs.) o 10 available not in house hang Drapes - Main Drape - red velour (dead hung - opens at centre stage with a hand pull SR) - 3 Black IFR Velour 25oz travelers (flown with hand winches, operated from SR) - 3 Black IFR Velour 25oz Borders and 1 set of legs (flown line sets) o Borders at 2nd and 3rd Lx and cyclorama - Soft Cyclorama (flown line set) Note: All rigging is subject to the approval of the Technical Director. All flies must be operated by authorized Massey Theatre staff. Audio System FOH Console - Yamaha QL5 Digital Mixing Console o Mix channels: 64 mono, 8 stereo o Busses: 16 mix, 8 matrix (Input to Matrix supported) o Local I/O: 32 in, 16 out o Fader configuration: 32 + 2 (Master) 4 Standard Layers, 4 Custom Layers - Rio 1608-D Stage Box o 16 In, 8 Out - Ro8-D Monitor patch rack o 8 Out Main PA - Meyer M elodie line array system. 8 M elodie powered cabinets per side, flown 5 downstage of the proscenium opening - 2 Meyer sound 700hp powered subwoofers (1 each side) 2 P a g e

- All Meyer Sound components driven by Meyer Galileo 616 system, located in the booth Monitor mix (Mixed from FOH console) - 10 Pre/ Post- fade aux s, Patchable to various locations around stage - 3 QSC MX 1500a amps Booth Equipment - 2 Denon CD/MP3 Decks (DN - 620) - PC Media Server w/ BlueRay playback capabilities - Mic Input Patch Bay - Clear-Com SM Station Mix Location - Booth located at rear of lower seating (under balcony) - 82' to stage front (allow at least 150' cable run to prosc.) - Monitor mix at FOH - Microphone lines - 30 patchable inputs from the stage. 5 locations - 48-8ch Snake from SL to console - Monitor patches 19 patchable outputs from 5 locations Microphones - 8 Shure SM 58 (2 switched) - 6 Shure Beta 58a - 3 Shure Beta 87a - 6 Shure SM 57-4 Shure Beta 57a - 1 Shure Beta 52-3 Shure PG56 (w/ drum mounts) - 2 Audio Technica Pro 37 Condensers - 4 Audio Technica ES935ML6-3 Sennheiser E614 Condensers - 3 AKG C3000 Condenser Mics - 2 Audix ADX-50 Condenser Mics - 2 Audio Technica Microlines - 2 Crown PCC - 6 DOD 625 Passive DI - 3 JDI Duplex DI - 3 JDI Mk III DI - 1 JDI Stereo DI 3 P a g e

Monitor Speakers - 8 db Technologies LVX XM12 Active Monitors - 4 EV SX300 Monitors (flown) - 8 EV SX300 Monitors (wedges) - 2 EV SX80 Monitors (Off Stage Fill) - Assorted microphone (XLR), speaker (1/4"), and sub snake cables Assorted microphone and speaker stands Communications - 3 channel Clear-Com Party Line o Patchable: Backstage/ Fly Rail/ Lighting/ Audio/ Spots/ Booth/ FOH - HME DX-200 Wireless Com o 4 Headsets and Transmitters - Program sound to Booths and Dressing Rooms o Stage management announce to Dressing Rooms from SL, SR - Lobby Feed o music / chimes Lighting Control/ Dimmers Console - ETC Ion w/ ELO Touch Screen and 2 nd monitor o 1024 Outputs/Parameters o 10,000 Channels o 10,000 Cues o 999 Cue Lists o 4 x 1000 Palettes (Intensity, Focus, Color, Beam) o USB ports for flash drives, pointing devices, keyboards - ETC Universal Fader Wing 2x20 Dimmers - 3 Colortran 1 Series 96 racks o 2.4 kw dimmers o Presently 270 dimmers wired circuit per dimmer House Hang Includes - 15 Area front wash (Source Four 750W Ellipsoidal) 4 P a g e

- 2 Color top wash (cool & scrollers)(source Four 575W Pars) - Two color bax-wash (Par 64s 1 KW WFL) - Two color side-wash (Altman 6x12's and 6x16's) - 34 Ellipsoidal specials ( 18 in FOH, 16 on stage) o Various Source Four barrels to select from (19 degree to 50 degree) Follow Spots - 2 Robert Juliat 1159 Victor Follow Spot w/ GT4000 Tripod Stands o 208V 1800W MSR Discharge o Optics: 7 14.5 Degree Any additions or changes to the house hang must be approved by the Technical Director prior to your contract date. Projection Cinema Projector - Christie CP2210 o 2k 3Chip DMD DLP 2048x1080 Pixels o 1.8kW Lamp o 12k Lumens o 2000:1 Contrast Stage Projector - Sony VPL-FX25 LCD Projector Film Screen - 35 W x 15 H Acoustically Perforated Screen - Hung at mid Stage Power - Tie in, tie out and daily amperage use are separate charges. - 400 Amp three phase service available (requires 100' feeder run to stage right) - 100 Amp three phase tie-in (stage right proscenium wall) 20amp break out available - Assorted 15 Amp circuits onstage 5 P a g e

If you have any questions concerning the technical information and inventory list please contact Technical Director, Mike Cooper: cooper@masseytheatre.com or 604 517 5900 ext. 6114 6 P a g e