TFR5 Room or outdoor temperature sensor. CombiTemp TM

Similar documents
TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM

CombiSeries. Making temperature, pressure and conductivity measurement safe and convenient.

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Inductive sensor NI3-EG08K-Y1-H1341

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Inductive sensor With analog output BI15-M30-LI-EXI

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Inductive sensor BI1.5-EG08K-Y1

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

7 Lighting Technology

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

8 Installation Equipment

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Inductive sensor NI10-M18-Y1X-H1141

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

PROPORTIONAL VALVES Sentronic plus

Single Point Flow Monitor SW118 SW119

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

SITRANS F M. Transmitter MAG 5000/6000 4/33

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Capacitance Level Measurement Electronic insert FEC 12

Rosemount 1151 Smart Pressure Transmitter

Flow Measurement SITRANS F M

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Model KBF 115 Constant climate chambers with large temperature / humidity range

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

ATEX-manual for units

Model JDF Field Indicator

Process Transmitter RMA 422

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Pressure transmitter For applications in hazardous areas Model IS-3

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Process transmitter RMA422

Model KT 115 Cooling incubators with thermoelectric cooling

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

POWER MOLE SERIES DA GAO RGBT RADIX

General Specifications

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

SERIES 400 SERIES 620

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

RMA42. Technical Information

2291 Guided Wave Radar Level Transmitter

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

DMP 331i / DMP 333i LMP 331 i

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Technical Information RIA45

Pulse Counters, electromechanical

LARGE DIGITAL TEMPERATURE LED DISPLAYS

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

OP5. Preprogrammed, configurable controller for simple applications

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Flow Measurement SITRANS F M

ACT20X Series for hazardous area applications Section A

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Eaton Durant. Counters, process instruments and hour meters.

02/11/2015

EXPlora. Introduction

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Dissolved Oxygen Transmitter

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Level Measurement Continuous level measurement - Capacitance transmitters

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Signal conditioning instruments

Model KT 53 Cooling incubators with thermoelectric cooling

Dissolved Oxygen Transmitter

Technical Information Gamma Modulator FHG65 Synchronizer FHG66

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

I Ex-protected connectors exlink I

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.

Mechanical flow switch for On/Off control

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Pendant Light Fitting IEC Series 6470/2

Selection matrix for electronic pressure switches

Transcription:

Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications (pending) Technical specifications Housing material El. connection Material Sensor tube dimensions Material Cable material for cable sensor FlexHousing, Ø80 mm Stainless steel, AISI 304 M16 cable gland M12 5-pin or M12 8-pin Plastic Stainless steel, AISI 303 Sensor element, Pt100 - DIN/EN/IEC 60751 Pt100 1/1 DIN class B Pt100 1/3 DIN class B Pt100 1/6 DIN class B Pt100 1/1 DIN class A Single element Resistance, ceramic terminal Analogue, built in transmitter Single element Connection Environment Media temperature and ambient temperature (air temperature) Protection class Humidity Fixed sensor Ø6 x 100 mm Cable sensor Ø5.8 x 60 mm Stainless steel, AISI 316L (1.4404) High flexible silicone, grey ± (0.3 + 0.005xt) C ± 1/3 x (0.3 + 0.005xt) C ± 1/6 x (0.3 + 0.005xt) C ± (0.15 + 0.002xt) C 1 x Pt100 Pt100 signal, 2, 3 or 4 wire, HART 1 x Pt100 2-wire or 4-wire -40... 85 C -30...80 C with DFON display -10...70 C with BattTemp display IP67 < 98% RH, condensing Display, DFON Type Front glass Display modes Background Graphically LCD Polycarbonate Measuring range -9999... 99999 Digit height 8 modes, programmable, e.g. value, bar graph, analogue, tank illustration, visual data logger White, green, red, programmable Max. 22 mm 0.1% @ ambient -10... 70 C Voltage drop 4V... 6.5V 2 configurables relay output, 60 Vp, 75 ma Programming Touch screen or FlexProgrammer 9701 Further information can be found in separate data sheet for DFON, D21.09 Display, BattTemp Type Front Glass Measuring range Power supply Comply to / s Comply to LCD Polycarbonate ±0.3 C Protection class IP 54 1 AA battery Further information can be found in separate data sheet for BattTemp 2400-1 EMC directive 2004/108/CE in accordance with EN61326-1/2013 Data sheet Page 1 / 5

Technical Data Wall mounting Cable sensor Fixed sensor 59 10 PCD Ø 95 PCD Ø 95 Ø 91 Ø 110 40 mm 100 mm Available with cable between sensor and housing in free selectable length Pipe mounting Cable sensor 70 Ø 91 DN38 DN51 DN64 40 mm Available with cable between sensor and housing in free selectable length Data sheet Page 2 / 5

Electrical connections M12, 55-wire fils M12, 88-wire fils 1 2 Cable gland Transmitter 1 +24VDC / - 4...20mA 2-24VDC / +4...20mA 1 Red clip (FlexProgrammer) 2 Black clip (FlexProgrammer) RTD Single Double 1+2 Pt100-1 3+4 Pt100-1 1 Pt100 1 2 Pt100 1 3 Pt100 2 4 Pt100 2 5 N.C. N.C. 1 + - supply, 2 Common for for relays 3 - + supply, ma 4 Relay 11 5 Relay 22 1 1 N.C. 2 2 + - supply, 3 3 Relay 1 1 4 4 Relay 1 1 5 5 Relay 2 2 6 6 Relay 2 2 7 7 - supply, + 4...20 ma 8 8 N.C. RTD Single White White Red Red Double White White Red Red Display 1 + 4...20 N.C. ma 2-4...20 N.C. ma 3 Relay 12 4 Relay 12 5 Relay 21 6 Relay 21 Com 1 Red clip (FlexProgrammer) Com 2 Black clip (FlexProgrammer) Temperature transmitters Transmitter, type FlexTop 2202 - Standard Pt100 <0. For further information please see data sheet for FlexTop 2202 Transmitter, type FlexTop 2211 - Performance Pt100 / Pt1000 (universal) <0.1 C For further information please see data sheet for FlexTop 2211 Transmitter, type FlexTop 2221 - performance, HART Pt100 / Pt1000 (universal) / HART <0.1 C By HART terminal/modem For further information please see data sheet for FlexTop 2221 Data sheet Page 3 / 5

Temperature transmitters - ATEX specifications Transmitter, type FlexTop 2202 - ATEX 8...28 VDC 10 µh 10 nf Temperature class T1...T5: -40 <T amb < 85 C U: 28 VDC Transmitter, type FlexTop 2221 - ATEX 8...30 VDC (Ex na : 12...30 VDC) 15 µh 5 nf Temperature class T1...T5: -40 <T amb < 85 C U: 30 VDC Transmitter, type FlexTop 2211 - ATEX Temperature class 6.5...30 VDC 1 5 µh 5 nf T1...T5: -40 <T amb <85 C <50 C U: 30 VDC DFON display - ATEX specfications ATEX Gas ia Gas Zone 0/1 II 1 G, Ex ia IIC T5 Ga Voltage drop U Disp 4.5... 6.5 VDC Temperature class T1...T5 Zone 0-20... 60 C Zone 1/2-30... 65 C <10 µh <15 nf U i <30 VDC I i <0.1 A <0.75 W P i ATEX Gas na Gas Zone 2 II 3 G, Ex na II T5 Voltage drop U Disp 4.5... 6.5 VDC Temperature class T1...T5-30 < T amb < 65 C <10 µh <15 nf Maximum voltage U max <35 VDC Maximum current I max <0.1 A BattTemp display - ATEX specfications ATEX Gas ia Gas Zone 0/1 Battery Ex II 1G, Ex ia IIC T4/T5 Energizer Lithium FR6 L91 AA T1...T4: -10 < T amb < 70 C T5: -10 < T amb Duracell Alcaline MN1500 LR6 AA T1...T4: -10 < T amb < 70 C T5: -10 < T amb < 60 C Data sheet Page 4 / 5

Ordering details Model CombiTemp TM TRF5 temperature room sensor Housing material FlexHousing Ø80 mm, Stainless steel, AISI 304, wall mount, cable sensor A FlexHousing Ø80 mm, Stainless steel, AISI 304, pipe mount DN38, cable sensor B FlexHousing Ø80 mm, stainless steel, AISI 304, pipe mount DN51, cable sensor C FlexHousing Ø80 mm, stainless steel, AISI 304, pipe mount DN65, cable sensor D FlexHousing Ø80 mm, stainless steel, AISI 304, wall mount, fixed sensor E Electrical connection (output) M12, 5 pins 1 M12, 8 pins 3 Cable gland, M16 5 No electrical connection - for BattTemp only 9 Material el. connection None - for BattTemp only 0 Plastic 1 AISI 303 3 Display Without display 1 With display No relays activated 2 With display With activated relays 4 With BattTemp Battery powered 6 Transmitter / socket Flying leads 0 Ceramic socket Pt100 1 Transmitter 2202 4-20 ma ±0.25 C 2 Transmitter 2211 4-20 ma ±0.10 C 3 Transmitter 2221 4-20 ma / HART ±0.10 C 4 Safety Standard 0 Ex ia IIC T4/T5 1G (Gas) (pending) 1 Ex na II T4/T5 3G (Gas) (pending) 3 Ex ia II 1 G Eex ia IIC, Zone 0, Pt100 output only (pending) 9 Configuration No configuration 0 Configuration of 1 Configuration of + Display 2 Sensor element (DIN/EN/IEC 60751) None (open cable gland) 0 1x Pt100 Class 1/1 B 1 1x Pt100 Class 1/3 B 5 1x Pt100 Class 1/6 B 7 1x Pt100 Class 1/1 A A Cable length None 0000 Cable length between housing and sensor in cm (0100 = 1 meter) 0000 Data sheet Page 5 / 5