E3C-LDA. Phone: Fax: Web: - Operating Procedures: Photoelectric Sensors

Similar documents
Main Display (Red) Displays the incident light level or the function name.

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

E3X-DA-S An Extensive of Standard Functions to Support the World's Highest Level of Stable Detection.

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

E3X-DAC-S Digital Fiber Sensor

802DN Series A DeviceNet Limit Switch Parameter List

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

SU17 Series Fiber Optic Sensors

Color Sensing. Digital Fiber Sensor E3X-DAC-S. Easy and Reliable. The Fiber Sensor That Sees in Color

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Amplifier for fiber optics. Dimensioned drawing

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors

USER MANUAL. VP-422 HDMI to PC Scaler MODEL: P/N: Rev 5

Models available for a wide variety of applications at manufacturing sites. 20mm 10mm

GreenParking. Commissioning guide. GreenParking

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VP-480 CV to 3G HD-SDI Scaler. P/N: Rev 3

Amplifier for fiber optics. Dimensioned drawing

IT-100 INSTRUCTION MANUAL

Electrical connection

Logic Design. Flip Flops, Registers and Counters

FRQM-2 Frequency Counter & RF Multimeter

RG NDT INTERNATIONAL INC

Sample BD Tech Concepts LLC

DF-G2 High Speed Expert Dual Display Small Object Counter. Instruction Manual

USER MANUAL. VP-426 HDMI-PC Scaler MODEL: P/N: Rev 4.

User interface. Abbreviations / Meanings

Short Manual. ZX2 Short Manual.doc Page 1 of 12

Variwrap Controller Manual

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

Long and Fast Up/Down Counters Pushpinder Kaur CHOUHAN 6 th Jan, 2003

American DJ. Show Designer. Software Revision 2.08

MUHAMMAD NAEEM LATIF MCS 3 RD SEMESTER KHANEWAL

Operating Instructions

Training Note TR-06RD. Schedules. Schedule types

Special Applications Modules

Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0)

DMX-LINK QUICK OPERATION

WELDING CONTROL UNIT: TE 450 USER MANUAL

Electrical connection

EN Wireless programmable thermostat

Sample BD Tech Concepts LLC

DF-G3 Long Range Expert Dual Display Fiber Amplifier Instruction Manual

Digital Fiber Sensor FX-300 SERIES. Constant advances achieving significant improvement of sensing performance

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

Digital Fiber Sensor FX-300 SERIES. Constant advances achieving significant improvement of sensing performance

Comfort System T-32-P Universal Thermostat. Operation Manual

EDL8 Race Dash Manual Engine Management Systems

REMOTE DISPLAY WIRELESS DECODER MK II

Micro/Junior/Pro PL7 Micro PLC Functions Upcounting. TLX DS 37 PL7 40E engv4

Electrical connection

CAP240 First semester 1430/1431. Sheet 4

Exercise 4-2. Counting of Actuator Cycles EXERCISE OBJECTIVE & & &

1. General Information:

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

KNX Dimmer RGBW - User Manual

Night Hawk Firing System User s Manual

Spektrum AirWare Change Log 2016-November-15

R20AD 10-bit Universal Decoder R-series Card Module User Manual

Counters

Q3X Laser Contrast Sensor

IO-Link Data Reference Guide: EZ-ARRAY Series

Instruction manual for 5024 Weighing Terminal

Digital Flow Switch for Large Flow

DA-88 QUICK TIPS (VERSION 4 SOFTWARE)

16 Stage Bi-Directional LED Sequencer

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 2 / SEAV LRS 2150 SET

OPERATION MANUAL MODEL DF3000 DIGITAL WEIGHT INDICATOR REVISION A-1

IT T35 Digital system desigm y - ii /s - iii

PROGRAMMING CODE SHEET

Warner Photoscanner MCS-836/836-1/836-2

CS-2T Timer. Safety. Controls and Indicators. Nordson Corporation OPERATOR S CARD P/N A

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

PQ-Box 100 Quick Start Instructions

SCENEMASTER 3F QUICK OPERATION

LA-1440 and LA-4440 Sound Level Meter

C O B A R 18R U s e r G u i d e P a g e 1. User Guide COBRA 18R. Wireless Firing System.

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

USER MANUAL. VP-424 HDMI to HDMI Scaler MODEL: P/N: Rev 2

USER MANUAL. VP-425 PC / Component to HDMI Scaler MODEL: P/N: Rev 3

Receiver Customization

Warner Photoscanner MCS-836/836-1/836-2

DSIM-GI Installation Guide Revision P

DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Instruction Manual

Basic Information Before Use. Display on LCD Screen. Distinction by. Patterns Recognition. Use of Applied Functions. Changing Set Value

Digital Fundamentals 11/2/2017. Summary. Summary. Floyd. Chapter 7. Latches

Contact-Type Digital Displacement Sensor. HG-S Series. User's Manual WUME-HGS panasonic.net/id/pidsx/global

Application Note 11 - Totalization

Type F70AB F70ABPN. Digital display. Simple operation featured

ENGINEERING PUBLICATION

SC24 Magnetic Field Cancelling System

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

No Need to Select. Intensity Detection (Previous Type)

RWL11X2 GREENHOUSE CONTROLLER. Operation Manual

Advanced Return Path Alignment & Maintenance Using the 9581 SST R4

Transcription:

E3C-LDA Operating Procedures: Photoelectric Sensors 1 Setting the Operation Mode The operation mode is set with the. Operation mode Operation Light ON L-ON Dark ON D-ON L (Factory-set) D *Advanced Twin-output Models: The operation mode is set in mode. Refer to 5. Setting Functions in Mode on page 18. To restore the default power settings: "OFF" will flash twice. OFF 2 *Advanced Twin-output Models (Same for All Adjustments): Set the Channel Selector Switch to the desired channel before making any adjustments or settings. Adjusting the Power ( Mode) The current incident light level can be adjusted to near the power tuning target value (default: 2,000). *Confirm that the Key setting is (power tuning). The default setting is. Refer to 5. Setting Functions in Mode on page 18. Selector Switch to. (default) The Power Tuning indicator will go out when the default setting has been restored. *Setting Errors An error has occurred if one of the following displays appears after the progress bar is displayed. Display Error Action Flashes twice OVER Flashes twice BOTM Over Error The incident light level is too low for the power tuning target value. Bottom Error The incident light level is too high for the power tuning target value. The power will not be tuned. The power can be increased up to approximately 1.5 times the incident light value. The power will be turned to the minimum level. The power can be decreased down to approximately 1/8th the incident light value. light value. (Factory-set to ) 3 Setting s Manually ( Mode) A threshold can be set manually. A threshold can also be finetuned using manual setting after teaching. Release the key after the progress bar is displayed. Display changes after specific time. Progress bar Selector Switch to. (Factory-set to ) (default) The Power Tuning indicator will light when the adjustment Power tuning target value Increases threshold. Decreases threshold. *Even if the display method for display switching is changed, the threshold will appear on the sub-display when the key is pressed.

4 Teaching the ( Mode) *There are three methods that can be used for teaching, as described below. Use the method most suitable for the application. *Teaching (with/without workpiece teaching and automatic teaching) can be performed in mode. For operating procedures, refer to Instruction Sheet provided with the product. *An error has occurred if OVER, LO, or NEAR is displayed on the sub-display. Repeat the operation from the beginning. 4-1. Teaching a Through-beam Fiber Unit without a Workpiece A value about 6% less than the incident light level (minimum difference) can be set as the threshold. This method is ideal when detecting very small differences in light level, such as when detecting very fine workpieces or transparent workpieces with a Through-beam (retroreflective) Unit. Selector Switch to. 4-2. Teaching a Reflective Fiber Unit without a Workpiece A value about 6% greater than the incident light level (minimum difference) can be set as the threshold. This method is ideal when using a Reflective Fiber Unit to detect workpieces so that detection is not influenced to any great degree by dust and other environmental factors. Selector Switch to. Either for RFCH THRU To 4-3. Teaching With and Without a Workpiece Two points, with and without the workpiece, are detected, and the intermediate point is set as the threshold. Selector Switch to. With a workpiece: Workpiece RFCH

5 Setting Functions in Mode *The function transition boxes show the default settings. Twin-output and ATC Models E3C-LDA11/LDA41/LDA6/LDA8 E3C-LDA11AT/LDA41AT/LDA6AT/LDA8AT Enter the functions by pressing the Key. To set the functions, refer to the list of functions and use the and Keys. Selector Switch Refer to 4. Teaching the ( Mode) on page 17. Teaching Operation mode (To set the operation mode) (To change response speed, detection precision, and detection method) (To use the timer setting.) Enables the timer. (ATC models only) ATC (To enable or disable ATC) (To reverse the orientation of the display.) (To change the display method) Key (To change the function of the Key during operation) Twin outputs (To change the output details for channel 29 Refer to 2. Adjusting the Power on page 16. Setting at power-on External Input Models E3C-LDA21/LDA51/LDA7/LDA9 Selector Switch Refer to 4. Teaching the ( Mode) on page 17. Teaching (To change response speed, detection precision, and detection method) (To use the timer setting.) External input (To change function controlled by external input.) Key (To change the function of the Key during operation) Enables the timer. Refer to 2. Adjusting the Power on page 16. External input batch setting (Refer to the Instruction Sheet provided with the product.) er (To set the counter function.) External input memory (Refer to the Instruction Sheet provided with the product.) (To reverse the orientation of the display.) (To change the display method)

Functions Use the and Keys to change the settings. Function Setting (display) Super-high-speed:, High-speed:, Standard:, High-precision:, Differential operation: (advanced models only) Description Used to increase response speed and detection precision. (differential Single edge:, Double edge: Used to set the edge to be detected. operation selected) Single edge 250 µs:, 500 µs:, 1 ms:, 10 ms:, 100 ms:, Double edge 500 µs:, 1 ms:, 2 ms:, 20 ms:, 200 ms: Used to set the differential response time. disabled:, OFF-delay timer:, ON-delay timer:, One-shot timer: Used to enable or disable timers. (timer enabled) Key (performing power tuning) 1 to 20 ms: 1-ms increments, 20 to 200 ms: 5-ms increments, 200 ms to 1 s: 100-ms increments, 1 to 5 s: 1-s increments Executes power tuning:, Executes a zero reset:, With/without workpiece teaching:, Automatic teaching: Setting range: 100 to 3,900 (increments of 100) Maximum power M: Used to change timer setting when timer is enabled. The timer can be set from 1 to 5000 ms. Used to change the function of the Key during operation. Used to set the target value during power tuning. Used to display the incident light level and the threshold. % light level Used to display the incident light level as a percentage of the threshold and the threshold. PEAK BOTM Used to display the peak and bottom levels of incident light within a set time. (Updated every 2 s.) L-PE D-BT status Used to display the incident light peak level and no incident light bottom level. (Refreshed when output turns ON or OFF.) Analog bar display. The current detection status is displayed as an analog bar. The bar will lengthen from the right as ON status is reached. (ON: Red; OFF: Green) Current light level PEAK Current light level Peak light level Used to display the current incident light level and the peak incident light level. Display changes at a fixed interval. Channel Used to display the incident light level and the channel. Operation mode * (twin-output models only) Twin outputs (twin-output models only) ATC (ATC models only) Setting at Power-ON (ATC ON) External input (external input models only) External input memory er External input batch setting Normal display: (For external input models only), Up/down reversed display: Light ON:, Dark ON:, Output for each channel:, Output if level is between the two thresholds:, Self-diagnosis output: ATC enabled:, ATC disabled: No setting:, ATC start processing:, Power tuning and ATC start processing: Thru-beam, no-workpiece teaching:, Reflective, no-workpiece teaching:, With/Without-workpiece teaching:, Automatic teaching:, Power tuning:, Zero reset:, Light OFF:, er reset: Write results to EEPROM:, Don't write results: er disabled:, incremented when output turns ON:, decremented when output turns ON: Setting range: 1 to 9,999,999 Only sensor that receives external input:, All linked sensors: *The operation mode and timer function can be set for each channel specified using the Channel Selector Switch. The settings for other functions will be the same for channel 1 and channel 2. Used to display the counter value. Used to reverse the orientation of the display. Refer to 1. Setting the Operation Mode on page 16. Used to change the output for channel 2. This setting is disabled if differential operation is set for the detection function. (Alarm outputs are always used for differential operation.) Used to enable or disable ATC. Used to set the processing to be performed when the power is turned ON. Used to change function controlled by external input. (Refer to Instructions provided with the product.) Used to set writing the results. (Refer to Instructions provided with the product.) Used to set the counter function. Used to set the counter value when the counter function is enabled. Used to set linked Amplifiers at the same time using an external input.

6 Convenient Functions 6-1. Zeroing the Digital Display (Zero Reset) The incident light level on the main display can be set to 0. * Change the function to 0RST (zero reset) with the Key. The default setting is. Set the / to. Factory setting To reset to 0 again: To return to original value for incident light level: 6-2. Locking the Keys (Key Lock) All key operations can be Set the / to. Factory setting "ON" will flash twice and key operations will be LOC ON To release the lock: "OFF" will flash twice and key operations will be LOC OFF * If a key is pressed while key operations are locked, "LOC" will flash twice on the display to indicate that key operations have been 6-3. Initializing Settings (Initial Reset) All settings can be returned to their original default settings. Set the / INIT YES? INIT NO? Settings initialized. Operation canceled.