立肯科技 LeColn Technology

Similar documents
DisplayPort TX & RX Testing Solutions

SDAIII-CompleteLinQ Multi-Lane Serial Data, Noise and Crosstalk Analysis

QPHY-HDMI2 Operator s Manual

DisplayPort Standard. Agilent, Inc. Draft2 January 14, 2013

Draft Baseline Proposal for CDAUI-8 Chipto-Module (C2M) Electrical Interface (NRZ)

Eye Doctor II Advanced Signal Integrity Tools

Tektronix Inc. DisplayPort Standard

QPHY-USB3 USB3.0 Serial Data Operator s Manual

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Keysight Technologies M8048A ISI Channels

Next Generation 인터페이스테크놀로지트렌드

PAM4 signals for 400 Gbps: acquisition for measurement and signal processing

Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR

Agilent E4887A HDMI TMDS Signal Generator Platform

Practical De-embedding for Gigabit fixture. Ben Chia Senior Signal Integrity Consultant 5/17/2011

PCI Express. Francis Liu Project Manager Agilent Technologies. Nov 2012

M809256PA OIF-CEI CEI-56G Pre-Compliance Receiver Test Application

Receiver Testing to Third Generation Standards. Jim Dunford, October 2011

100G EDR and QSFP+ Cable Test Solutions

SV1C Personalized SerDes Tester

Switching Solutions for Multi-Channel High Speed Serial Port Testing

Prepare for Next Generation USB Technology Testing

SPARQ Signal Integrity Network Analyzer. High-bandwidth, Multi-port S-parameters

USB 3.1 ENGINEERING CHANGE NOTICE

The Measurement Tools and What They Do

Datasheet SHF A

DisplayPort 1.4 Link Layer Compliance

ELECTRICAL PERFORMANCE REPORT

12G-SDI Physical Layer Analysis using the Ultra 4K Tool Box

BRR Tektronix BroadR-Reach Compliance Solution for Automotive Ethernet. Anshuman Bhat Product Manager

Emphasis, Equalization & Embedding

Next Generation Ultra-High speed standards measurements of Optical and Electrical signals

Features. For price, delivery, and to place orders, please contact Hittite Microwave Corporation:

Dual Link DVI Receiver Implementation

32 G/64 Gbaud Multi Channel PAM4 BERT

10Gbps SFP+ Optical Transceiver, 10km Reach

WAVEEXPERT SERIES OSCILLOSCOPES WE 9000 NRO 9000 SDA 100G. The World s Fastest Oscilloscope

EVALUATION KIT AVAILABLE Multirate SMPTE SD/HD Cable Driver with Selectable Slew Rate TOP VIEW +3.3V. 10nF IN+ IN- MAX3812 SD/HD GND RSET +3.

How advances in digitizer technologies improve measurement accuracy

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

SV1C Personalized SerDes Tester. Data Sheet

WAVEEXPERT 100H. Wide Bandwidth Oscilloscopes for the Next Generation Serial Data Standards

HMC958LC5 HIGH SPEED LOGIC - SMT. Typical Applications. Features. Functional Diagram. General Description

PicoScope 6407 Digitizer

ASNT_PRBS20B_1 18Gbps PRBS7/15 Generator Featuring Jitter Insertion, Selectable Sync, and Output Amplitude Control

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

Jitter and Eye Fundamental & Application. Jacky Huang AE, Tektronix Taiwan

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams

10Gb/s SFP+ ER 1550nm Cooled EML with TEC, PIN Receiver 40km transmission distance

HMC-C060 HIGH SPEED LOGIC. 43 Gbps, D-TYPE FLIP-FLOP MODULE. Features. Typical Applications. General Description. Functional Diagram

MIPI DigRF 3G and v4 Decode

X-Stream DSO Version 3.6 Release Notes

o-microgigacn Data Sheet Revision Channel Optical Transceiver Module Part Number: Module: FPD-010R008-0E Patch Cord: FOC-CC****

SDLA Visualizer Serial Data Link Analysis Visualizer Software Printable Application Help

De-embedding Gigaprobes Using Time Domain Gating with the LeCroy SPARQ

Systematic Tx Eye Mask Definition. John Petrilla, Avago Technologies March 2009

Using Allegro PCB SI GXL to Make Your Multi-GHz Serial Link Work Right Out of the Box

PicoScope 6407 Digitizer

Agilent 86100C Infiniium DCA-J

Physical Layer Compliance Testing for HDMI 1.4a Using TDSHT3 HDMI Compliance Test Software

Agilent N6467A BroadR-Reach Compliance Test Application. Methods of Implementation

New Serial Link Simulation Process, 6 Gbps SAS Case Study

SUNSTAR 微波光电 TEL: FAX: v HMC750LP4 / 750LP4E 12.5 Gbps LIMITING AMPLIFIER

C-PHY Essentials Transmitter Test Solution TekExpress C-PHY Essentials Tx

Solutions to Embedded System Design Challenges Part II

SignalTap Plus System Analyzer

CDAUI-8 Chip-to-Module (C2M) System Analysis #3. Ben Smith and Stephane Dallaire, Inphi Corporation IEEE 802.3bs, Bonita Springs, September 2015

Keysight E4887A HDMI TMDS Signal Generator Platform. Data Sheet Version 2.1

QPHY-DDR4. Instruction Manual

Logic Analysis Basics

Logic Analysis Basics

Brian Holden Kandou Bus, S.A. IEEE GE Study Group September 2, 2013 York, United Kingdom

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

RX40_V1_0 Measurement Report F.Faccio

100G QSFP28 SR4 Transceiver

Serial ATA International Organization

10Gbps 10km Range SFP+ Optical Transceiver

Memory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope

A 90 Gb/s 2:1 Multiplexer with 1 Tap FFE in SiGe Technology

InfiniBand Trade Association

HMC-C064 HIGH SPEED LOGIC. 50 Gbps, XOR / XNOR Module. Features. Typical Applications. General Description. Functional Diagram

Ethernet SFP+ QSFP+ Tx Compliance & Debug Solution SFP-TX, SFP-WDP Datasheet

10Gbps 10km Range 1310nm SFP+ Optical Transceiver

The Case of the Closing Eyes: Is PAM the Answer? Is NRZ dead?

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

DisplayPort and HDMI Protocol Analysis and Compliance Testing

Agilent Technologies Pulse Pattern and Data Generators Digital Stimulus Solutions

80SJNB Jitter, Noise, BER, and Serial Data Link Analysis (SDLA) Software Printable Application Help

80SJNB Jitter, Noise, BER, and Serial Data Link Analysis (SDLA) Software Printable Application Help

DATA SHEET. Two (2) fibers Detachable HDMI 2.0 Extender,

The Effect of Inserted ISI on Transition Density Plots and DCD & ISI Histograms of MJS Patterns

EMPOWERFIBER 10Gbps 2km SFP+ Optical Transceiver EPP C

10Gb/s SFP+ Optical Transceiver Module 10GBASE-LR/LW

40G SWDM4 MSA Technical Specifications Optical Specifications

ASNT8140. ASNT8140-KMC DC-23Gbps PRBS Generator with the (x 7 + x + 1) Polynomial. vee. vcc qp. vcc. vcc qn. qxorp. qxorn. vee. vcc rstn_p.

Simplifying HDMI Compliance Testing

The Challenges of Measuring PAM4 Signals

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

Transcription:

DisplayPort PHY Validation 立肯科技 LeColn Technology 1

DisplayPort Basics Maximum bit rate DP1.2b 1.62Gb/s( RBR = reduced bit rate) 2.7Gb/s( HBR = high bit rate) 5.4Gb/s( HBR2 =high bit rate 2) DP1.3/1.4 8.1Gb/s( HBR3 =high bit rate 3) Number of signals to test 4 data lanes 4 data lanes Required scope bandwidth 13GHz 16GHz DRAFT 6/13/2014 2

Test Point Descriptions Five test points have been identified for physical layer measurement: TP2: at the test interface on a test access fixture as close as possible to the DP mated connection to a Source device. TP3: at the test interface on a test access fixture as close as possible to the DP mated connection to a Sink device. TP3_EQ: There are two defined cable models. One cable model is the worst cable model as defined in DP 1.2a, the other cable model is the zero length, zero loss cable. The equalizer is also defined in DP 1.2a. TP2 TP3 TP3_EQ Ref. RX EQ TX Cable RX 07/14/2017 3

DP PHY Compliance Test Standard VESA DisplayPort PHY Compliance Test Standard: 3.1 Eye Diagram Testing 3.2 Non Pre-Emphasis Level Verification Testing 3.3 Pre-Emphasis Level Verification and Max Diff Pk-Pk Output Voltage 3.4 Inter-Pair Skew Test 3.5 Intra-Pair Skew Test 3.10 AC Common Mode Noise 3.11 Non ISI Jitter Measurements 3.12 Tj, Rj and Dj Jitter Measurements 3.14 Main Link Frequency 3.15 SSC Modulation Frequency 3.16 SSC Modulation Deviation 3.16 Dual-Mode TMDS Clock Testing 3.16 Dual Mode TMDS Eye Diagram Testing 8.1 AUX Channel Eye Test 07/14/2017 4

EYE Diagram & Jitter EYE Diagram Testing RBR and HBR: TP2 HBR: TP3_EQ (emulated in Analyzer SW from TP2 acquisition) HBR2: TP3_EQ (emulated in Analyzer SW from TP2 acquisition) HBR3: TP3_EQ (emulated in Analyzer SW from TP2 acquisition) The EYE Diagram test shall pass the TP3_EQ test point using both a worst case and a zero length cable model as described below. It is required that the source provides at least one unique setting (Voltage Swing, Pre-Emphasis Level, Post-Cursor2 Level, and Equalization) that will pass each cable model. 07/14/2017 5

EYE Diagram Eye pattern computation D+ Diff = D+ - D- D- Eye 07/14/2017 6

EYE Diagram Eye pattern computation PLL CLK Main Link: Second-order clock recovery function with a closed loop tracking bandwidth of 10MHz with a damping factor of 1.00 for HBR2 10MHz with a damping factor of 1.51 for HBR 5.4MHz with a damping factor of 1.51 for RBR UI=one bit time 07/14/2017 7

EYE Diagram TP2 Connection for Source Compliance Tests TP2 TP2 TP3 Worst Cable D+ TP3 Worst Cable + EQ TX D+ 07/14/2017 8

Transmitter De-emphasis Loss and Channel BW - Worst Cable Model Transmitter Receiver TP2 TP3 TX Cable RX 07/14/2017 9

Transmitter De-emphasis Loss and Channel BW - Worst Cable Model Transmitter Receiver TP2 TP3 TX Cable RX 07/14/2017 10

Transmitter De-emphasis De-emphasis and Worst Cable model 0dB 3.5dB 6dB 9.5dB 07/14/2017 11

Jitter Measurement Total jitter(tj) is a measure of the maximum peak-to-peak jitter at a specified bit error rate (BER), for example Tj=n*Rj + Dj (BER=10-9) Tj 07/14/2017 12

Jitter Measurement Deterministic Jitter Obtain DJ PDF via deconvolution and associated pk-pk (directly from jitter PDF, or derivative of BER CDF) 07/14/2017 13

Jitter Measurement Tj, Rj and Dj & Non ISI Jitter Measurements 07/14/2017 14

Attributes of the Signal that can be Varied Lane, Bitrate, Pre-emphasis, Amplitude, SSC, Test Pattern Bitrate Pre-emph Amplitude SSC Test Pattern 1.62 0 400mV On PLTPAT 2.7 3.5 db 600mV Off D10.2 5.4 8.1 6 db 9.5 db 800mV 1200mV Symbol error rate pattern CP2520 HBR2 Compliance HBR3 Compliance 6/13/2014 15

Automation PHY Validation The QPHY-DisplayPort software provides an automated test environment for running all of the normative real-time oscilloscope tests for sources in accordance with Version 1.2b of the Video Electronics Standards Association (VESA) DisplayPort PHY Compliance Test Specification, as well as tests for HBR3 signals at 8.1 Gbps. Support for RBR, HBR, HBR2, and HBR3 bit rates (1.62 Gb/s, 2.7 Gb/s, 5.4 Gb/s, and 8.1 Gb/s) Support for testing of 1, 2 or 4 lanes 100% automated testing using Unigraf DPR-100 with AUX Control capability 07/14/2017 16

DP Test Fixture Wilder Technologies http://www.wilder-tech.com/dp-kits.htm Key Electrical 1.35Gb/s, 2.7Gb/s, 5.4Gb/s, and 8.1Gb/s data rates supported Insertion loss < -3dB @ 6.5GHz / Return loss < -20dB @ 4.25GHz Differential Impedance 100+/-5 ohms / Single Ended Impedance 50+/-2.5 ohms 07/14/2017 17

AUX Controller and switch matrix Automation - Automatic configuration of DUT settings using AUX controller - Unigraf DPR-100 Reference Sink, Commands DUT via AUX lines to go into appropriate modes, No manual user-configurations required! Aux controller https://www.unigraf.fi/products/dp-test-hardware/dpr-100 DPR-100 is operating as a DP AUX Controller to automate the DP PHY testing with a compliant PHY Test Equipment. With the AUX Controller firmware DPR-100 is compatible with TeledyneLeCroy oscilloscopes Switch Matrix https://www.minicircuits.com/webstore/dashboard.html? model=usb-4spdt-a18 Mini-circuits Switch Matrix support for 4-lane testing No connect/disconnect of cabling! 6/13/2014 18

QualiPHY = The TOTAL PC Solution QualiPHY = QPHY = An electrical (PHY) Compliance serial data standard package SOLUTION The QualiPHY software application automates the oscilloscope setup test and report generation. Bit Rate / OutputLevel / Pre-emphasis / Pattern / SSC are configured by Aux controller 07/14/2017 19

Connection Diagram with Switch and AUX Controller QualiPHY displays connection diagrams to ensure tests run properly 6/13/2014 20

Report (The sample of HBR3) 07/14/2017 21

USB Type-C DP ALT Mode Test Fixture Luxshare-ICT http://www.luxshare-ict.com/cpzsnn/info_224.aspx?itemid=1818&lcid=162 Type-C connector DispalyPort ALT mode Type-C to DP dongle 07/14/2017 22

HDMI PHY Validation 立肯科技 LeColn Technology 23

HDMI Basics HDMI 1.4b HDMI 2.0 Maximum bit rate 3.4 Gb/s 6.0 Gb/s Number of signals to test 3 data + 1 clock 3 data + 1 clock Required scope bandwidth 8 GHz 13 GHz Required input adapter TF-HDMI-3.3V TF-HDMI-3.3V DRAFT 6/13/2014 24

Test Point Descriptions The signal test points for a TMDS link are shown in below. TP1 is used for testing of HDMI Sources and Transmitter components. TP2 is used for testing of HDMI Sinks and Receiver components. TP1 and TP2 together are also used for testing of cables. TP1 TP2 TX Cable RX Source Sink 07/14/2017 25

HDMI1.4 TMDS Electrical Compliance 7-2: VL 7-4: TRise, TFall 7-5: Over/Undershoot (Not Mandatory) 7-6: Inter-Pair Skew 7-7: Intra-Pair Skew 7-8: Clock Duty Cycle 7-9: Clock Jitter 7-10: Data Eye Diagram 07/14/2017 26

HDMI2.0 TMDS Electrical Compliance HF1-1: VL and Vswing HF1-2: Trise Tfall HF1-3: Inter-pair Skew HF1-4: Intra-pair Skew HF1-5: Differential Voltage HF1-6: Clock Duty Cycle HF1-7: Clock Jitter HF1-8: Data Eye Diagram 07/14/2017 27

EYE Diagram TP1 Connection for Source Compliance Tests Apply the Worst Cable Emulator to measure TMDS differential signals at TP2 eye TP1 Data TX Source CLK 07/14/2017 28

Test fixture Wilder Technologies http://www.wilder-tech.com/dp-kits.htm Key Electrical: 4.95Gb/s and 10.2Gb/s data rates supported Insertion loss < -3dB @ 9.6GHz / Return loss < -20dB @ 3.3GHz Differential Impedance 100+/-5ohms / Single Ended Impedance 50+/-2.5 ohms 29

EDID controller For compliance testing, the HDMI source must be controlled to output the correct signals for each test For those who cannot, they will need to use an Extended Display Identification Data (EDID) controller, which talks to the source over the HDMI link and tells it what to output Granite River Labs HDMI-CONT for EDID control http://graniteriverlabs.com/hdmi-cont/ HDMI-EDID-EMS (Source (Host) Emulator) http://www.wilder-tech.com/hdmi-a-20-kits.htm 30

Switch matrix Mini-circuits RC-8SPDT-A18 https://www.minicircuits.com/webstore/dashboa rd.html?model=rc-8spdt-a18 Since HDMI testing requires both single-ended and differential measurements on 4 differential signals, we need to measure 8 signals total QPHY-HDMI2 has functionality built in to control a switch matrix for this purpose Using the switch matrix also requires a separate HDMI termination module, the Wilder Technologies HDMI-TPA-T http://www.wilder-tech.com/hdmi-a-20-kits.htm 31

TF-HDMI-3.3V 50 ohms Pull-up Terminator The TF-HDMI-3.3V adapter provides the necessary 3.3 V pull-up termination for HDMI testing. The TF-HDMI-3.3V provides both a signal path through to the oscilloscope with a 3.3 V pull-up termination as well as an input that is directly terminated to 3.3 V. This is required for terminating the data lines that are not currently under test. The TF-HDMI-3.3V-QUADPAK provides four adapters and 8 SMA-SMA cables to allow for the testing of all HDMI signals (Clock, D0, D1 and D2). 07/14/2017 32

QualiPHY = The TOTAL PC Solution QualiPHY = QPHY = An electrical (PHY) Compliance serial data standard package SOLUTION The QualiPHY software application automates the oscilloscope setup test and report generation. QualiPHY displays connection diagrams to ensure tests run properly 07/14/2017 33

Report (Sample of HDMI2.0) 07/14/2017 34

High Speed Serial Bus Debug Section 1 - Probing LeColn, Service and Support Division 立肯科技 LeColn Technology

WaveLink Hi-BW Differential Probing System(13GHz 25GHz) Example of D2505-A-PS Teledyne LeCroy Confidential 2012 11/16/2012 36

Platform/Cable Assembly + Amplifier Module + Interconnect Lead 1. Connecting the Amplifier Module to the Platform/Cable Assembly 2. Connecting a solder-in interconnect lead to an amplifier module NOTE: The entire SI tip should be positioned with the resistor side upright facing (away from the PCB plane). Keep a 45 degree angle between the SI tip ends and the PCB plane. 25 07/14/2017 37

Caution: This configuration has non-standard leads added to probes which are not matched, and add inductance A probe with flat geometry and rubberized flex circuit lead can be easily secured in place Adhesive base mount Tips soldered to chip pins Probing discrete components 07/14/2017 38

Caution: This configuration has non-standard leads added to probes which are not matched, and add inductance When damping resistors are removed for connection to the interposer, the leads should be replaced with 3mm 34 gauge wire 07/14/2017 39

Caution: Using square pin or other adapters which reduce rated bandwidth can reduce measurement accuracy Square pin connectors are typically rated at 3GHz BW Solder-in tip rated at 13 GHz bandwidth 07/14/2017 40

Ultra-compact Size - positioner tip browser Teledyne LeCroy s Dxx05-PT positioner tip browser can be easily hand-held with the attachable wand or positioned in place with one of many standard or optional accessory mechanical positioners. 07/14/2017 41

High Speed Serial Bus Debug Section 2 - SDA3 (Serial Data Analysis 3) LeColn, Service and Support Division 立肯科技 LeColn Technology

Serial Data Jitter Analysis & Debug Requires Deep, Accurate Insight Into Jitter Breakdown Compliance Testing Tj (Total Jitter) Rj (Random Jitter) Dj (Deterministic Jitter) (Bounded Uncorrelated Jitter) BUj DDj (Data Dependent Jitter) Debug & Analysis Pj OBUj DCD ISI Periodic Jitter Other BUj Duty Cycle Distortion InterSymbol Interference 07/14/2017 43

Continuous Bit Eye Pattern Rendering Real Time Eye (consecutive UI) Block of continuous serial data acquired Bits are separated using software clock recovery Overlapped bits form the eye pattern 07/14/2017 44

Total Jitter Total jitter is a measure of the maximum peakto-peak jitter at a specified bit error rate (BER) The specified BER is another way of expressing a confidence interval or observation time Total jitter is determined by integrating the probability density function (PDF) separately from the left and right sides to determine the cumulative probability density (CDF) The width of this curve at the specified BER (or confidence interval) gives the total jitter Total jitter CDF 07/14/2017 45

Histogram Growth Source: JitterTime Consulting 07/14/2017 46

Jitter Components Separation of random and deterministic jitter Tj = N*Rj + Dj N = sigma value for selected BER Dj = p-p deterministic jitter Approximate heuristic formula Measure Tj at several BER values and solve for Rj and Dj 1 2 3 4 Tj1 Tj2 Tj3 Tj4 07/14/2017 47

Jitter Analysis Component of Dj : ISI(Inter-Symbol Interference) Ideal data data Edge shift made by former data pattern is called as ISI It is typical in cases of insufficient bandwidth.

Jitter Analysis Component of Dj : DDj(Data Dependent jitter)

SDA3 = Sigtest + Advance Analysis Tools Transition Eye / Non-Transition Eye / Jitter are as same as Sigtest Transition Eye Non-Transition Eye 07/14/2017 50

Apply Equalization and De-embed / Emulate Fixtures & Channels SDAIII-CompleteLinQ seamlessly integrates transmitter emphasis and receiver equalization features Use EyeDoctorII or the new VirtualProbe package Emphasis, De-embed/Emulate, Equalization: EyeDoctorII EyeDoctorII-VP SDAIII-CompleteLinQ 07/14/2017 51

Channel Emulation Measured at end of reference channel and cables at TP1 Before Channel Emulation After Channel Emulation Import S-parameter (S4P) 07/14/2017 52

Apply Equalization with Eye Doctor II SDAIII-CompleteLinQ seamlessly integrates transmitter emphasis and receiver CTLE, FFE and DFE equalizers No Equalization CTLE DFE 07/14/2017 53

Measurement Challenge Transmitter Receiver Eq Backplane Differential Probe Differential Probe 1. For very fast data rates (>5 Gb/s), the transmitter signal typically has very good signal integrity. However, after propagating through the backplane, this signal will become severely degraded. 2. At the far end of the channel, the eye is closed. The signal at the receiver pins (which can be probed) is not the signal of interest. The equalized signal inside of the receiver chip (which cannot be probed) is the signal of interest. 3. The equalized signal within the receiver chip cannot be probed. How can this signal be validated to ensure low jitter, a clean eye pattern, and good signal integrity? 07/14/2017 54

EyeDoctor II and VirtualProbe Signal Integrity Tools 07/14/2017 55

High Speed Serial Bus Debug Section 3 WaveScan (Advanced Search and Analysis) LeColn, Service and Support Division 立肯科技 LeColn Technology

Auto Parameters, but not smart Scope captures lots of cycles, Why Rise Time(20%-80%) is only 29ps? 07/14/2017 57

Smart Parameter Statistic ON = Full Cycles/Screen measurement First screen = 24,832 Statistic num = 24,832 Second screen = 24,801 Statistic num = 24,832+24,801 Third screen = 24,768 Statistic num = 24,832+24,801+24,768 Fourth screen = 24,866 Statistic num = 24,832+24,801+24,768+24,866...You get every Rise Times via Smart Parameter! 07/14/2017 58

Smart Parameter, but hard to debug How can I view and analysis waveforms >40ps Rise Time(20%-80%)? 07/14/2017 59

Wavescan = Smart Waveform scan capability Scans for an event in many acquisitions over a long period of time. It support 6 search modes, apply a search condition and begin scanning is very simple. 07/14/2017 60

Finds Problems That Triggers Won't Find A Teledyne LeCroy X-Stream oscilloscope will quickly scan millions of events, looking for unusual occurrences, and do it much faster and more efficiently than other oscilloscopes can. 1 2 3 4 5 07/14/2017 61

High Speed Serial Bus Debug Section 4 LabNotebook (Flashback tool) LeColn, Service and Support Division 立肯科技 LeColn Technology

A Complete In-scope Solution - Documentation Our users can efficiently create complete and detailed waveform reports directly in the oscilloscope. An allin-one solution for annotating and sharing information, LabNotebook simplifies results recording and report generation by eliminating the multi-step processes that often involve several pieces of equipment. Save Waveforms = Keep Datas Save Table = Keep Parameters values Save Setup = Keep scope setups Print Screen = Keep the pictures Labnotebook = Save waveforms + Table + Setup + Print Screen And + Report Generator 07/14/2017 63

A Complete In-scope Solution - Documentation Flashback is one of the most powerful features in LeCroy s LabNotebook documentation tool. Not only does LabNotebook save a report of a user selected test, it also can store the acquired waveforms and oscilloscope setup. If you find yourself in the position of having not taken a specific measurement during the test, with Flashback you can recall the data and make additional measurements. 07/14/2017 64

Customize Report Generator LabNotebook enables the users to focus on results : Save all display waveforms Save the relevant DSO setup with saved waveforms Add freehand notes with a stylus Convert the complete report to PDF,HTML,RTF Print or e-mail reports 07/14/2017 65

I forgot to measure Fall Time(20%-80%) before Power Off Fortunately, You created a Labnotebook entry before Power Off 07/14/2017 66